Saudi Diyar Consultants: King Faisal Specialist Hospital AND Research Centre

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1

6
CLIENT

100800

8400

8400

8400

8400

8400

1975

2
500
1250

T16@120 TOP ADD.


L=6000

2000

4185

2500

2700

T25@150 TOP ADD.


L=6000
4000

2350

2500

2350

2500

4000

C1

2350

2350

C1

5.

ALL PIPE SLEEVES & OTHER BUILDER'S WORK


REQUIREMENTS FOR ELECTRO-MECHANICAL WORKS,
SHALL BE COORDINATED WITH THE APPROVED
ELECTRO-MECHANICAL SHOP DRAWINGS BEFORE
CONCRETING.

6.

FOR COLUMNS, FOOTING DETAILS & SCHEDULES


REFER TO DRAWING NO. 1257B03-S701.

7.

ALL PERIMETER COLUMNS SHALL CONTINUE UP TO


PARAPET LEVEL, UNLESS OTHERWISE INDICATED.

8.

FOR SIZES & LOCATIONS OF SLAB OPENINGS,


TRENCHES & PITS REFER TO ELECTRO-MECH.
DRAWINGS.

9.

SOIL BEARING CAPACITY BELOW FOUNDATION SHALL


NOT BE LESS THAN 2.50 Kg/sqcm . CONTRACTOR SHALL
VERIFY THIS ASSUMPTION BEFORE STARTING
CONSTRUCTION . IN CASE OF ANY DISCREPANCY
BETWEEN THE DESIGN SOIL BEARING CAPACITY & SOIL
CONDITION REFER TO CONSULTING ENGINEER.

2500

2500

2T20@150 BOTT. ADD.


L=6000

T20@150 BOTT. ADD.


L=5600
T14@150 TOP ADD.
L=6000

2350

IN CASE OF ANY DISCREPANCY BETWEEN STRUCTURAL


DRAWINGS & SITE CONDITIONS, REFER TO THE
CONSULTING ENGINEER.

11. REINFORCING STEEL BARS SHALL BE DEFORMED HIGH


GRADE STEEL OF YIELD STRENGTH 4200 KG/SQ.CM.
(MIN.)

4000

T20@150 BOTT. ADD.


L=5600
T14@150 TOP ADD.
L=6000

2350

4.

12. UNLESS OTHERWISE SPECIFIED. REINFORCED


CONCRETE SHALL HAVE A MIN. 28 DAYS CYLINDER .
STRENGTH OF 400 KG/SQ.CM.

4000

2350

ALL DIMENSIONS ARE IN MILLIMETERS.

2T20@150 BOTT. ADD.


L=6000

2350
2350
2350

3.

10. PLAIN CONCRETE USED IN BLINDING SHALL HAVE


MINIMUM 28 DAYS CYLINDER STRENGTH OF 200
KG/SQ.CM.

4000

C1/F4

C1/F3

8400

2350

T20@150 BOTT. ADD.


L=5600
T14@150 TOP ADD.
L=6000

T20@150 BOTT. ADD.


L=5600

2500

2350

C1/F3

2350

C1
4000

2500
2500
2350

2T20@150 BOTT. ADD.


L=6000

2350
2350
2350

2350

T20@150 BOTT. ADD.


L=6600

T16@150 BOTT. ADD.


L=7000

4000

2500

2350

5000

C1

4000

4000

T20@150 TOP ADD.


L=6000

4900

8400

1500

C1/F3

4000

2000
2350

C1

C1/F3

T14@150 TOP ADD.


L=6000

2000

2350

C1

2500

4000

4000

ALL DIMENSIONS & LEVELS ARE TO BE COORDINATED


WITH ARCHITECTURAL & CIVIL DRAWINGS.

C1/F4

2350

T20@150 BOTT. ADD.


L=5600

C1/F3

2500

2350

4000

2000

2350

C1
1900

C1

2T16@150 BOTT. ADD.


L=6000

2000

4000

2500

2T20@150 BOTT. ADD.


L=6000

2500

2.

4000

T25@150 TOP ADD.


L=6000

9900

2500

C1/F3

2350

C1/F3

5000

2T16@150 BOTT. ADD.


L=7000

5000

T20@150 BOTT. ADD.


L=6600 C1

4000

2500

FOR GENERAL NOTES, SEE DWG. NO. 1257B01-S001...

3250

8400

2000

4185

2000

2500

T20@150 BOTT. ADD.


L=6600 C1

2T16@150 BOTT. ADD.


L=7000

2000

2500

2500

C1

T25@150 TOP ADD.


L=6000

8400

4500

2350

T25@150 BOTT. ADD.


L=11000

1.

C1/F4

2500

4185

1900

2350

5000

C1/F4

4000

2350

2100

425

2850

2500

C1

T16@150 BOTT. ADD.


L=7000

2100

2350

T20@150 BOTT. ADD.


L=6600

F6

T32@150 BOTT. ADD.


L=6500

2700

1577
2850

2500

T25@150 BOTT. ADD.


L=11000

2700

8400

8400

C1/F4

2350

1000 1000

500
T25@120 BOTT. ADD.
L=12000
CORE No. 10
& STAIR No. 07

NOTES:

C1/F3

2350

SUB CONSULTANT:

5945

2100

T16@120 BOTT. ADD.


L=5000

T16@120 BOTT. ADD.


L=5000

T16@120 BOTT. ADD.


L=5000

1455

5300

T16@120 TOP ADD.


L=6000

C2

5900

2350

3250

Saudi Diyar Consultants

5900

T25@120 BOTT. ADD.


L=12000

C1

T32@120 TOP ADD.


L=12000

5300

5300

T32@120 TOP ADD.


L=12000

3200

2350

C1

T32@150 BOTT. ADD.


L=6500

2350

500 500

1800

3773

C1

5300

5300

2100

2100

2875

725
2350

5500

F7

250

250

CORE No. 07
& STAIR No. 06

CONSULTANT:

750 500

900

C1/F3

2350

4225

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE

7400

2100

8400

550 425

900

1300

500

350 900

8400

MATCH LINE SEE DWG NO. 1257B03-S102c

8400

4000

4000
2

REVISED AS CLOUDED

02/03/2015

REVISED AS CLOUDED

06/19/2014

REV.NO.

DESCRIPTION

DATE

KEY PLAN
N

2500
2350

2500

2500

C1/F4

2350

2500

C1/F3

2350

C1/F3

2350

C1/F3

4000

C1

2500

2500

C1/F4
2500

C1/F3

2350

C1/F3

2350

C1/F3

2350

T20@150 BOTT. ADD.


L=12000

T20@150 TOP ADD.


L=12000

CORE No. 02
& STAIR No. 01

2350

2350

2350

2500
2350

2350

2500

2500

8400

2350

2350

T25@150 BOTT. ADD.


L=12000

2350

2350

2700

G
E

1257B03-S102b

4000

C1

YS

T20@150 BOTT. ADD.


L=5600

C1

MECHANICAL
MA

ICT
ZM

CIVIL/LS

DRAWN BY

CHECKED BY

AE/HF

HM

AR

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE
Jeddah - Saudi Arabia

B03 KITCHEN & LAUNDRY


DRAWING TITLE:

4000

PARTIAL
FOUNDATION PLAN
PART a

4000

IC
T
A

10

SCALE 1:100

FA

T20@150 BOTT. ADD.


L=5600

STRUCTURAL

PROJECT TITLE:

4000

4000

T20@150 BOTT. ADD.


L=5600

ARCHITECT
SL

ELECTRICAL

1257B03-S102b

FOUNDATION PLAN - PART a


1a PARTIAL
SCALE
1:100 M.
1

C1

T14@150 TOP ADD.


L=6000

2350

T14@150 TOP ADD.


L=6000

2350

T14@150 TOP ADD.


L=6000

2350

2500

2350
2350

4000

4000

4000

2350

ELEVATOR PIT WITH DIMENTION


600x600x600 MM.

21000

8400

8400

2350

AM

T20@150 BOTT. ADD.


L=5600

MATCH LINE SEE DWG NO. 1257B03-S102c

90000

14000

2350

2350

4000

PROJECT MANAGER

56800

56800

8400

CORE No. 03

2T20@150 BOTT. ADD.


L=6000

2350

2T20@150 BOTT. ADD.


L=6000

2350

T14@150 TOP ADD.


L=6000

2350

4000

4000

2350

8400

2350

4000

4000

ELEVATOR PIT WITH DIMENTION


600x600x600 MM.

T14@150 TOP ADD.


L=6000

12

T20@150 BOTT. ADD.


L=5600
T14@150 TOP ADD.
L=6000

T20@150 BOTT. ADD.


L=5600

2T20@150 BOTT. ADD.


L=6000

2350

2350

2350

4000

C1

2T20@150 BOTT. ADD.


L=6000

C1

4000

4000

C1

2T20@150 BOTT. ADD.


L=6000

4000

2T20@150 BOTT. ADD.


L=6000

C1

C1/F4

C1/F3
2500

C1/F3
2350

C1/F3

2350

3250

2350

1500

10750

METERS

EM

SC

SCALE

DATE

CAD FILE

1:100

APRIL 2014

1257B03-S102

DRAWING NUMBER

1257B03-S102a

REVISION

2
Saudi Diyar Consultants

You might also like