Professional Documents
Culture Documents
Medición de Nivel Tipo Radar
Medición de Nivel Tipo Radar
Medición de Nivel Tipo Radar
turing process.
Reduced Maintenance
Application Flexibility
maintenance
Head can be removed while tank is in service
for easier repair or upgrades
No re-calibration required
Easy Installation
Superior Reliability
Top-down measurement
Loop powered
Coaxial
The optimal solution for level and interface measurement in all clean liquids
such as solvents, alcohols, water-based
liquids, LPG, and liquid ammonia.
Recommended for liquids with low dielectric constants and applications with
turbulence, high ow, foam, liquid, or
vapor spray near the probe (the coax
acts as a stilling well). The coaxial probe
is available in Std, HP, and HTHP versions
and in SST, Hastelloys or Monel material.
Twin lead
For liquid applications such as oil
products, solvents, water-based liquids,
etc. Also suitable for interface measurements. Handles media that is more
viscous than the coaxial probe. Avoid
sticky media where there is risk of product bridging between probes. The twin
leads are available in Std version and in
SST material.
Single lead
The single lead probes are the most
tolerant against coating and deposits.
The rigid single lead is recommended
for smaller tanks with viscous liquids,
slurries, beers/spirits, water based liquids, and hygienic applications in the
food & beverage or pharmaceutical
industries. Available in Std, HP, and
HTHP versions and in SST, Hastelloy,
Monel, or PTFE covered SST material.
The exible single lead is especially
suitable for measuring solids, granulates, and powders like grain, sand,
carbon black, etc. It also measures
viscous products like syrup and honey
as well as water-based liquids. Available
in Std version and in SST or PTFE covered
SST material.
Inputs/outputs
User-friendly conguration
The Radar Conguration Tools is a user-friendly,
333 Tri-Loop
4-20 mA
4-20 mA
751 Remote
Display
4-20 mA
HART / 4-20 mA
DCS
3300 Series
Transmitter
HART modem
Fn
1
2 3
4 5
6
7 8
9
. 0
-
375 Field
Communicator
Radar
Configuration
Tools
Summary specication
Product
Process connection
Threaded or anged
Probe materials
Process temperature
Std version up to 300 F (150 C), HTHP/HP version up to 752 F (400 C). See PDS for complete data
Process pressure
Std version up to 580 psig (40 bar), HTHP/HP version up to 5000 psig (345 bar). See PDS for complete data
Power supply
Loop-powered (2-wire), 1142 VDC (11-30 VDC in I.S. applications, 1642 VDC in
Explosion Proof /Flame Proof applications.)
Output
Reference accuracy
Complete specications are provided in the Product Data Sheet, ref no. 00813-0100-4811. Specications are subject to change without prior notice.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks
of Rosemount Inc. PlantWeb is a registered trademark of the Emerson Process Management group of companies. All other marks are the property of
their respective owners. 2005 Rosemount Inc. All rights reserved.
Emerson Process Management
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906 8888
F (952) 949 7001
www.rosemount.com