TECHNICAL SPECIFICATIONS Comparition

RX-50V (MICROLAB)

RX-50 (MICROLAB)

Compliance on each parameter with detailed


Sr.
substantiation how the offered product meets
No.
the requirement.
1

RX-50 V have 235 programmable tests 35


displaying on board & 200 in memory locations

RX-50 V have end point with sample blank with or


without reagent blank,kinetic ,two point with or
without reagent blank and end point, kinetic and
two point kinetic with multiple standard mode
and differntial mode also.

3
4
5
6
7
8
9
10
11
12
13

RX-50V have 8 Filters Editable


RX-50 V have 0.0 to 3.0 ABS
RX-50 V have 1000 results memory
RX-50 V have minimum consumption of 250 ul
reagents with aspiration volume from 100ul to
1000ul.
RX-50 V have 30 records for each control
RX-50 V have 3 level of control per test.
RX-50 V have user friendly Software.
RX-50 V have provision to run 3 replicates each
of standard and sample.
RX-50 V have test result and graph with OD for
KIN tests available on screen.
RX-50 V have optional USB Keyboard apart from
inbuilt keyboard
RX-50 V have 240 x 128 graphical LCD display.

RX-50 V have multilevel operation password for


14 programming a method and instrument
functions, service & calibration.
15 RX-50 V have real time graph for kinetic tests.
Bi-Directinal Pump (Aspiration & Dispens which
16
help you to clean the Flowcell)
17 Inbuilt Calculator Lipid Profile/Bilirubin / TIBC
18 Kinetic Graph Storage upto 10sample
19 Editable printing Option

Same as RX-50V

YES

YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
Yes
Only Lipid Profile
NO
YES

20 Triplicate sample and Triplicate Calibration option

NO

Inbuilt Incubator with Three independent


editable timers

NO

22 Estimated reading in all Kinetics at 1st delta

YES

21

23 information about Dilution ratio on display


24 Inbuilt HbA1C programme
Variable Temperature Range from 20 C to 40 C in
25
steps of 1 C
Daily and Monthly monitoring of 3 levels of QC
26
with
27 Levy-Jennings Plot
6 mm Round Glass Tube for Coagulation to
28
perform PT & APPT in Half test
29 Adjustable display
30 High speed peinter with easy loading paper
31 RS232 interfacing with PC
32 Divided with 4 PCB Board inside the instruments
33 Helogen Lamp (12v20w with 2000hrs Life)

NO
NO
Fix temprature
RT,25,30 & 37C

34 Lamp Saver Mode with instrument standy mode

YES

35 Reagent Stock Inventry with reminder


36 Calibration reminder Option

YES
YES

YES
YES
Yes
YES
YES
YES
YES
YES

ARX-199I(MICROLAB)

ARX-199(MICROLAB)

200 Prog

200 Prog

NO

No

YES
YES
YES

YES
YES
YES

YES

YES

NO
NO
Partialy

NO
NO
Partialy

NO

NO

YES

YES

NO

NO

240x64

240x64

YES

YES

YES

YES

Yes

Yes

NO

NO

NO
NO

NO
NO

NO

NO

Incubator without Timer

NO

NO

NO

NO
NO
Fix temprature RT,25,30 &
37C

NO
NO
Fix temprature RT,25,30 &
37C

NO

NO

NO

NO

Yes

Yes

NO
YES
YES
YES
YES

NO
YES
YES
YES
YES

YES

YES

YES
NO

YES
NO