Structural Details of Pile & Pilecap: Notes

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

STRUCTURAL DETAILS OF PILE & PILECAP

850

NOTES:

100

1. DRAWING PARAMETERS
* ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE MENTIONED ON DRG.
* FIGURED DIMENSIONS SHALL BE FOLLOWED.
:
CLEAR CONCRETE COVER FOR
REINFORCEMENT:
* THE MINIMUM CLEAR COVER TO THE MAIN REINFORCEMENT FOR DIFFERENT R.C.C
WORKS SHALL BE AS MENTIONED BELOW UNLESS STATED OTHERWISE.

20# @ 190 C/C (TOP & BOT)


(BOTH WAYS)

CONSTRUCTION PARAMETERS:
COVER DETAILS:

300

* FOUNDATION (Pile ) - 75mm


* FOUNDATION (Pile cap ) - 50mm

P.C.C (100 mm THK)

12000

10#@250 C/C (Helical Reinforcement)


20-18#(THO)
12#@1200 C/C
(Spacer bar)

LEGENDS
* L.S = LONGITUDINAL SECTION, * G.A.D = GENERAL ARRANGEMENT DRAWING
* C.S = CROSS SECTION
* Tho. = THROUGH
* Typ. = TYPICAL
DESIGN PARAMETERS
* GRADE OF CONCRETE - fck - 30 For Pile & Pile cap (Raft Slab).
* GRADE OF STEEL
- fy - 415 For Pile & Pile cap (Raft Slab).
LAP LENGTH
MINIMUM LENGTH - 41xd (d: least diamater of two bars)
DEVELOPMENT LENGTH : (from inner face of the support)
MINIMUM LENGTH - 50xd (d: diamater of bar)

12#@1200 C/C
(Spacer bar)

20-18#(THO)

750

SECTION B-B

NOTE:
AT THE PLE CAP REINFORCEMENT PROVIDE TO ALTERNATELY ( TOP & BOT) .
SHOWN IN PLAN OF PILE & PILE CAP.

(SCALE 1: 12.5)
* FOUNDING LEVEL SHELL BE 1.2 INTO MODERATE WEATHERED ROCK WHERE
THE PENETRATION RATE IS LESS THAN 20 CM / HR USING 3 TONS CHISEL
10#@250 C/C (Helical Reinforcement)

* FOUNDING LEVEL VARIES


750

DETAIL-1
(SCALE 1: 12.5)

WITH HEIGHT OF FALL 60 CM

You might also like