PROJECT

Calc No.

AREA

SC

BY

Typical Connection details.

TITLE

SHEET

DATE

08/08/2015

Analysis of Typical Connection Details:

Minimum Capacities of Detail 2A and 1A


Bolt Size
No. of bolts

=
=

16

mm

nos

Shear Capacity
Axial Capacity

150.6

kN

180.6

kN

This document is the exclusive property of ANE Consultants Ltd, and must be returned on demand. The document must only be used for the purpose for which it is issued.
The contents of this document are strictly confidential and must not in any circimstances be copied, shown, published or otherwise transmitted to any third party without
the authorisation of ANE consultants Ltd

2
DT

CHK

08/08/2015

DATE

of

PROJECT

Calc No.

AREA

BY

Typical Connection details.

TITLE

SHEET

DATE

SC

of

DT

CHK

08/08/2015

DATE

08/08/2015

Maximum Load from the structure

FtEd

92

kN

Axial Capacity FtRd

180.6

kN

FvEd

65

kN

Shear Capacity FvRd

150.6

kN

Maximum

Maximum

Combined Capacity

FvEd
FvRd

65
150.6

FtEd
FtRd

92
180.6

<

1.4

0.94

<

UR

0.5094 OK

UR

0.4316 OK

1.4

By inspection the connection is OK.


Provide 12 mm thick plate and 6mm fillet weld all around.