Professional Documents
Culture Documents
Specification For Fabricated PVC Fittings For Potable Water Supplies
Specification For Fabricated PVC Fittings For Potable Water Supplies
Specification For Fabricated PVC Fittings For Potable Water Supplies
( Reaffirmed 1998 )
Indian Standard
SPECIFICATION FOR
FABRICATED PVC FITTINGS FOR
POTABLE WATER SUPPLIES
PART 10 SPECIFIC REQUIREMENTS
FOR 45 BENDS
( First Revision )
First Reprint FEBRUARY 1993
UDC
BUREAU
MANAK
621.643.4.062.3[678.743.223:696.117
OF
BHAVAN.
INDIAN
STANDARDS
9 BAHADUR
SHAH
NEW DELHI
110002
ZAFAR
MARG
December 1988
hdian Standard
SPECIFICATION FOR
FABRICATED PVC FITTINGS FOR
POTABLE WATER SUPPLIES
PART
l-0 SPECIFIC
(
REQUIREMENTS
FOR 45 BENDS
First Revision )
0. FOREWORD
D .l This Indian Standard ( Part 10 ) ( First Revision ) was adopted by the Bureau of Indian
Standards on 20 June 1988, after the draft tinalized by the Sanitary Appliances and Water
Fittings Sectional Committee had been approved
by the Civil Engineering Division Council.
Part
Part
Part
Part
Part
9 Specific
10 Specific
11 Specific
12 Specific
13 Specific
requirements for
requirements for
requirements for
requirements for
requirements for
60 bends
45 bends
30 bends
22p bends
11% bends
0.4 For the purpose of deciding whether a particular requirement ~of this standard is complied
with, the final value, observed or calculated,
expressing the result of a test or analysis, shall be
rounded
off in accordance with IS : 2-1960t.
The number of significant places retained in the
rounded off value should be the same as that of
the specified value in this standard.
1. SCOPE
criteria
for conformity
IS : 10124 ( Part 1 )-1988*.
shall
conform
to
2.2 Manufacture
2.2.1 A typical
shown in Fig. 1.
illustration
of 45 bend
is
2. REQUIREMENTS
2.1 General
material,
for
and
revision );
3. MARKING
3.1 Each 45 bend fitting shall be marked with
the following information:
a) Manufacturers name or identification mark,
for potable
FIG. 1 45 BEND
*Specification
for unplasticized PVC pipes for potable
..
water suppnes ( second revision ).
TABLE 1 DIMENSIONS
OF 45 BENDS
iin
SIZS
in millimetres.
MINIMUM WALL
W
Min
( Only for
plain ends )
-------0.4 MPa
( Class 2 )
(2)
(1)
75
149
177
(3)
63
75
90
110
212
259
125
140
160
180
290
225
250
280
315
63
355
400
450
500
560
630
(4)
TEICKNIWS
PRESSURE
( f )
0.6 h---,---MPa
( Class 3 )
(6)
(5)
BOR WORKING
1.0 Mz
( Class 4 )
(7)
189
225
14
17
20
24
3.2
3.8
90
110
270
330
19
23
28
34
4.5
5.5
295
330
125
140
377
424
471
530
589
160
180
200
225
250
375
420
480
2.7
29
34
3.9
4.4
49
6.3
70
8.0
540
600
675
3.8
4.2
4.7
5.5
6.2
69
9.0
IO.0
112
660
742
837
842
1060
1 178
280
315
355
400
450
500
560
630
750
840
945
1065
5.2
5.8
6.5
7.3
7.7
8.6
9.7
108
125
139
15.6
171
1200
1350
8.2
93
12.2
137
198
224
248
103
15.3
1500
11%
17.2
1 680
130
1 890
192
NOTE- Minimum wall thickness if calculated on the basis of 90 percent of the minimum
correspondmg
size and pressure class of pipe rounded off to the next higher 0.1 mm.
1 319
1484
45
from x 2n R.
360
-tR, radius of the bend, is equal to 3 times the nominal
+Y is calculated
outside diameter
( D ).
278
31.3
wall thickness of the
IS:10124(Part lo)-1988
NOTE - The use of the Standard Mark is governed
by the provisions
of the Bureau of Indian Standards
Act 1986, and the Rules and Regulations made thereunder. The standard mark on products covered by an
Indian Standard conveys the assurance that they have
been produced to comply with the requirements of that
standard under a well defined system of inspection,
testing aod quality control which is devised and aupervised by BIS and operated by the producer.
Standard
marked products are also continuously checked by BIS
for conformity to that standard as a further safeguard.
Details of conditions under which a licence for the use
of the Standard Mark may be granted to manufacturers
Ior producers
may be obtained from theBureau
of
ndian Standards.
be marked in colour as
below
for different classes of
Class of Fitting
Colour
Class 2 (0'4MPa )
Class 3 ( 06 MPa )
Blue
Class 4 ( 10 MPa )
Green
Yellow
of Indian Standards
Date of Issue
Text Affected
Regional O&es
: Manaksanstha
to all Offices )
Telephone
t 331 01 31
331 13 75
35-C CHANDIGARH
Southern
Western
: Manakalaya,
160036
600113
I 37 84 99,
37 86 26,
37 85 61,
37 86 62
53 38 43,
53 23 84
53 16 40,
235 02 16,
c 235 15 19,
235 04 42,
235 23 15
632 92-95,
63278
91,
I
632 78 58,
632 78 92
Branches : AHMADABAD,
BANGALORE.
BHOPAL, BHUBANESHWAR,
COIMBATORE,
PARIDABAD,
GHAZIABAD,
GUWAHATI,
HYDERABAD, JAIPUR, KANPUR,
LUCKNOW, PATNA, THIRUVANANTHAPURAM
.
Reprography Unit, BIS, New Delhi, India