Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DESIGN OF CT-PROP LOCK PIN

LARSEN & TOUBRO LIMITED


BUILDING & FACTORIES I.C.- KOLKATA CLUSTER
BUILDING STRUCTURE COMPETENCY CENTRE
DESIGN BY
MEMBER
SHEATHING MEMBER
SECONDARY MEMBER
PRIMARY MEMBER
PROP
CANTILEVER LENGTH OF SECONDARY
CANTILEVER LENGTH OF PRIMARY

INPUT CELL COLOUR

UDIT NAG
MATERIAL
SPACING UNIT
12mm PLY
H-16 TIMBER BEAM
400
mm
H-16 TIMBER BEAM 1300
mm
CT 410
1400
mm
500
mm
500
mm

CHECK FOR SEATHING


THICKNESS OF SLAB =

150 MM

FLOOR TO FLOOR HEIGHT =

3.05 m

OR

DEAD WT OF SLAB =

3.9 KN/M^2

LIVE LOAD =

1.5 KN/M^2

DEAD WT OF FORMWORK =

1 KN/M^2

TOTAL LOAD =
MATERIAL

6.4 KN/M^2
12mm PLY

PLY THICKNESS =
SECONDARY MEMBER IS

0.15 M

12 mm
H-16 TIMBER BEAM

DEPTH OF SECONDARY MEMBER =

EI =

0.94 KN-m2

FLANGE WIDTH =

65 mm

160 mm

ASSUMING SPACING OF SECONDARY MEMBER =

400 mm

L (EFFECTIVE) =

347 mm

UDL =

OR

OR

0.4 m

0.347 m

6.4 KN/m
PERMISSIBLE VALUES

BENDING MOMENT =

0.078 KN-m

SAFE

0.2

SHEAR FORCE =

1.333 KN

SAFE

6.16

DEFLECTION =

0.00069 m

OR

PROVIDE SPACING OF SECONDARY MEMBER =

0.69 mm

SAFE

1.5

400 mm

CHECK FOR SECONDARY MEMBER


MATERIAL

H-16 TIMBER BEAM

UDL =

2.56 KN/m

EI =

ASSUMING SPACING OF PRIMARY MEMBER =

145 KN-m2
1300 mm

OR

1.3 m

L =

1300 mm

OR

BENDING MOMENT =

0.55 KN-m

SAFE

PERMISSIBLE VALUES
3

SHEAR FORCE =

1.67 KN

SAFE

DEFLECTION =
PROVIDE SPACING OF PRIMARY MEMBER =

0.00066 m

1.3 m

OR

0.66 mm
1300 mm

SAFE

CHECK FOR CANTILEVER LENGTH OF SECONDARY MEMBER


CANTILEVER LENGTH

LT =

500 mm

BENDING MOMENT =

WLT2/2 =

0.32 SAFE

PERMISSIBLE VALUES
3

SHEAR FORCE =

WLT =

1.28 SAFE

DEFLECTION =

WLT4/8EI =

0.00014 m

OR

0.5 m

OR

0.14 mm

EI =

145 KN-m2

SAFE

CHECK FOR PRIMARY MEMBER


MATERIAL

H-16 TIMBER BEAM

DEPTH OF SECTION =

160 mm

UDL =

8.32 KN/m

ASSUMING SPACING OF CT PROP =

1400 mm

OR

1.4 m

L =

1400 mm

OR

BENDING MOMENT =

2.039 KN-m

SAFE

PERMISSIBLE VALUES
3

SHEAR FORCE =

5.824 KN

SAFE

DEFLECTION =

0.00288 m

PROVIDE SPACING OF CT PROP =

1.4 m

OR
1400 mm

2.88 mm
OR

SAFE

1.4 m

CHECK FOR CANTILEVER LENGTH OF PRIMARY MEMBER


CANTILEVER LENGTH

LT =

500 mm

BENDING MOMENT =

WLT2/2 =

1.04 SAFE

PERMISSIBLE VALUES
3

SHEAR FORCE =

WLT =

4.16 SAFE

DEFLECTION =

WLT4/8EI =

0.00045 m

OR

0.5 m

OR

0.45 mm

SAFE

CHECK FOR CT PROP


FLOOR TO FLOOR HEIGHT =

3.05 m

CLEAR HEIGHT =
PROVIDE CT PROP

2568 mm

OR

OR

3050 mm
2.6 m

CT 410

ALLOWABLE LOAD ON PROP =

31.5 KN

LOAD ON EACH PROP =

11.648 KN

SAFE

CHECK FOR CT PROP LOCK PIN (CUSTOM)


LET US CONSIDER FACTORED LOAD COMING ON EACH PROP =
LET US TAKE LOAD COMING ON EACH PROP (W) =

(11.648 x 1.5) =
18 KN

CT-PROP OUTER PIPE DIA =

55 MM

CT-PROP INNER PIPE DIA =

43 MM

PLEASE REFER BELOW FIGURE FOR BETTER UNDERSTANDING


FOR ANALYSIS PURPOSE PLEASE REFER "SIMPLIFIED LOAD DIAGRAM OF CT PROP LOCK PIN"

17.472 KN

ANALYSIS OF LOCK PIN


(W/2) =

9 KN

(W/2) =

9 KN

CT-PROP LOCK PIN

43 MM
6 MM

6 MM

(INNER PIPE DIA)

55 MM

RA

(OUTER PIPE DIA)

RB

MMAX
BENDING MOMENT DIAGRAM

RA
SHEAR FORCE DIAGRAM

RB

BENDING MOMENT (MMAX) =

(9 X 1000 X 6) N-MM =

SHEAR FORCE (V) = RA = RB =

54000 N-MM

9 KN

GRADE OF STEEL USED

OR

9000 N

Fe 500D

DIA OF THE BAR = D =

12 MM
113.04 mm2

CROSS SECTIONAL AREA OF THE BAR (A) =

500 N/mm2

THEREFORE YIELD STRESS = (fy) =


ALLOWABLE BENDING STRESS SHOULD BE

() = (0.66 X fy) =

330 N/mm2

ALLOWABLE SHEAR STRESS SHOULD BE

() = (0.4 X fy) =

200 N/mm2

ACTUAL BENDING STRESS

() = M/Z

HERE SECTION MODULUS

(Z) = ( X D3)/32 =

() = M/Z =
ACTUAL SHEAR STRESS

169.56 mm3
318.47 N/mm2

() = V/A =

HENCE WE CAN USE Fe 500 D BAR AS CT-PROP LOCK PIN

< ALLOWABLE VALUE

79.62 N/mm2 < ALLOWABLE VALUE

SAFE
SAFE

You might also like