Professional Documents
Culture Documents
ABL1, ABL7 and ABL8: Phaseo Power Supplies
ABL1, ABL7 and ABL8: Phaseo Power Supplies
Catalog
2011
Contents
v Redundancy module. . . . . . . . . . . . . . . . . . . . . . . . . 46
2
2. On the Search results page, select
the first listing under Product &
Technical Library entitled Power
Supplies- Schneider Electric
Schneider Electric.
3 O
n the Products page under Phaseo Regulated Switch Mode Power Supplies
select from the following product lines, including: Modular, Optimum, Universal,
Universal Function Modules and Dedicated Line.
4
5
7 A
nd, when you select Phaseo
Universal Function Modules and
click on Overview, you'll find out
about the Uninterruptable Power
Supply (UPS) System and the
Interactive Demo.
Selection guide
Power supplies
Input voltage
100 to 240V a
120 to 250V c
Connection to
United States
world-wide line supplies - 120V (in phase-to-neutral)
- 240V (in phase-to-phase)
Europe
- 230V (in phase-to-neutral)
- 400V (in phase-to-phase)
United States
- 277V (in phase-to-neutral)
- 480V (in phase-to-phase)
IEC/EN61000-3-2 conformity
Yes for ABL7RP, not for ABL8REM and not applicable for ABL8MEM and ABL7RM
Yes
Diagnostic relay
No
5V c
48V c
Output voltage
Output current
12V c
24V c
0.3A
ABL8MEM24003
(Modular)
0.6A
ABL8MEM24006
(Modular)
1.2A
ABL8MEM24012
(Modular)
ABL8MEM12020
(Modular)
2A
2.5A
ABL7RM24025
(Modular)
3A
ABL8REM24030
(Optimum)
4A
ABL7RP4803
(Optimum)
ABL8MEM05040
(Modular)
ABL7RP1205
(Optimum)
5A
ABL8REM24050
(Optimum)
6A
10A
20A
40A
Pages
14
20
Selection guide
24V c
Yes
Yes
No
24V c
5V c
7 to 12V c
ABL8DCC12020 (2)
ABL8RPS24030
ABL8RPS24050
ABL8DCC05060 (2)
ABL8RPS24100
ABL8RPM24200
ABL8WPS24200
ABL8WPS24400
26
36
Selection guide
Power supplies
Input voltage
100 to 240V a
120 to 370V c
Connection to
United States
world-wide line supplies - 120V (in phase-to-neutral)
- 240V (in phase-to-phase)
Europe
- 230V (in phase-to-neutral)
- 400V (in phase-to-phase)
Single-phase (N-L1)
United States
- 277V (in phase-to-neutral)
- 480V (in phase-to-phase)
Single-phase (N-L1)
IEC/EN61000-3-2 conformity
Diagnostic relay
No
Output voltage
12V c
Output current
24V c
ABL1REM24025
2.5A
3A
ABL1RpM24042
4.2 A
4.8 A
5A
ABL1REM12050
ABL1RpM24062
6.2A
8.3A
ABL1RPM12083
ABL1RpM24100
10 A
Pages
50
Selection guide
/
100 to 240Va
Single-phase (N-L1) connection
Single-phase (N-L1) connection
No
Yes
Yes
Yes
No
30Vc
24Vc
ASIABLB3002
ASIABLD3002 (1)
ASIABLM3024 (2)
ASIABLM3024 (2)
ASIABLB3004 (2)
ASIABLD3004 (1)
56
(1) With ground fault detection.
(2) One output 30 c and one output 24 c 5%.
Overview
Overview
The Phaseo electronic switch mode power supply offer is designed to provide the DC
voltage necessary for the PLC and automation system equipment control circuits.
These power supplies include five ranges:
vv Modular, Optimum and Universal ranges for common applications (ABL8 and ABL7)
vv AS-Interface range for the AS-Interface cabling system (AS-Interface)
vv Dedicated range for repetitive equipment (ABL1)
The Phaseo offer meets all the needs encountered in industrial, commercial and
residential applications. With phase-to-neutral (N-L1), phase-to-phase (L1-L2) or
3-phase (L1-L2-L3) connection to the line supply, these electronic switch mode
power supplies provide a quality of output current that is suitable for the loads
supplied and compatible with the line supply available in the equipment. Clear
guidelines are given for selecting protection devices which are often used with them,
and thus a comprehensive solution is provided that can be used in total safety.
Phaseo switch mode power supplies
Phaseo switch mode power supplies are totally electronic and their output voltage is
regulated. Theuse of electronics makes it possible to significantly improve the
performance of these power supplies, which offer:
bb Very compact size
bb Integrated overload, short-circuit, overvoltage and undervoltage protection
bb Very wide input voltage range for the Universal range
bb High degree of output voltage stability
bb Good performance
bb Diagnostics via LED indicators on the front panel
bb Remote diagnostics via a relay contact for the Universal range
Phaseo power supplies deliver a stabilized c output voltage that is precise to 3%,
whatever the load from a a line supply, within the ranges of:
bb For Modular, Optimum, Dedicated and AS-Interface ranges:
vv 100 to 240 V afor phase-to-neutral (N-L1) or phase-to-phase (L1- L2)
connection
bb For the Universal range:
vv 85 to 550V afor phase-to-neutral (N-L1) or phase-to-phase (L1- L2)
connection
vv 360 to 550V afor 3-phase connection (L1-L2-L3)
Conforming to IEC standards and UL, CSA, TV and C-Tick certified, they are
suitable for industrial use.
Phaseo power supplies also incorporate:
bb Output voltage adjustment potentiometer in order to be able to compensate for
any line voltage drops in installations with long cable runs
bb Direct mounting on 35mm DIN rails, optional on Dedicated range (1)
(1) The Optimum and AS-Interface ranges can also take 75 mm DIN rails.
10
Overview (continued)
Overview (continued)
The Phaseo Modular range meets all the needs of simple automation systems with
power ratings from 7 to 60W and an output voltage of5V c,12V c or24V c.
The shape and compact nature of its casing mean that it can be incorporated either
in a modular panel or mounted on a DIN rail in a cabinet. Direct mounting on a panel
(using its two retractable legs) and the choice of wires exiting at the top or bottom
(except for the ABL7RM24025 model) make it an easy product to integrate.
ABL8MEM12020
The Phaseo Optimum range is the low-cost solution for applications supplied in
12Vc, 24V c or48V c and requiring currents between 3and5A.
The Optimum range of Phaseo power supplies delivers a voltage that can guarantee
the PLC logic states. In the event of an overload the power supply protection trips so
that, once the detected fault has been eliminated, the power supply reverts to its
nominal state.
Since the Optimum range of Phaseo power supplies does not have PFC (Power
Factor Correction), they do not meet the requirements of standard
IEC/EN61000-3-2 (except for ABL7RP1205/7RP4803 models).
ABL8REM24030
ABL8RPS24100
ABL8BUF24400
The Universal range of Phaseo power supplies covers power ratings from 72 to 960W
in24V c and adapts to the majority of power distribution systems used throughout the
world. The same power supply can thus be connected phase-to-neutral (N-L1) or
phase-to-phase for line supplies ranging from100V a to500V a nominal. This
product offering also includes three phase units. In addition, this range offers:
bb Diagnostic functions (local or remote)
bb User choice of operating mode in the event of an overload (current limiting or stop)
bb Function modules to help ensure continuity of service:
vv Protection against microbreaks or prolonged outages by means of the Buffer
module and Battery Control modules
vv Paralleling and redundancy functions by means of the Redundancy module
bb Power reserve (boost function) for absorbing the transient current peaks required
by the application
With the Universal range of power supplies, it is possible to satisfy the need for
auxiliary voltage (5V cto 15Vc) using c/c Converter modules.
The incorporation of a PFC (Power Factor Correction) input filter reduces harmonic
pollution to a minimum level across the entire Universal range, ensuring compliance
with the requirements of standard IEC/EN 61000-3-2.
ASIABLp30p4
ASIABLp3002
ABL1RpMpp0pp
ABL1RpM24100
The Dedicated range of Phaseo power supplies from 60 to 240W is designed for
integration in repetitive equipment requiring a voltage of 12V c or24V c.
These electronic switch mode power supplies, with phase-to-neutral (N-L1) connection,
with or without anti-harmonic filter and UL508, CSA and TV certified, meet all the
needs encountered in commercial machines and standard catalog machines.
11
Overview (continued)
12
Overview (continued)
13
Introduction,
description
ABL8MEMppppp
Zelio Logic
The Modular range of Phaseo power supplies can be connected in phase-toneutral (N-L1) or in phase-to-phase (1) (L1-L2). They deliver a voltage that is precise
to 3%, whatever the load and whatever the type of line supply, within a range of 85 to
264Va. Conforming to IEC standards and UL, CSA and TUV certified, they are
suitable for global use. They have overload and short-circuit protection.
Due to their low power, the Modular range of Phaseo power supplies consume very
little harmonic current and thus are not subject to the requirements of standard
IEC/EN61000-3-2 concerning harmonic pollution.
All the Modular range of Phaseo power supplies have protection devices to help
ensure optimum performance of the automation system with an automatic reset
mode on elimination of the detected fault.
All products are equipped with an output voltage adjustment potentiometer in order
to be able to compensate for any line voltage drops in installations with long
cable runs.
These power supplies also have a cable channel on the side of the unit so that the
output wires can be directed to the top or bottom of the product as required.
They are designed for direct mounting on 35 mm DIN rails, or on a panel using their
retractable mounting legs.
There are six references available in the Phaseo Modular range:
bb ABL8MEM24003
bb ABL8MEM24006
bb ABL8MEM24012
bb ABL7RM24025
bb ABL8MEM05040
bb ABL8MEM12020
7W
15W
30W
60W
20W
25W
0.3 A
0.6 A
1.2A
2.5A
4A
2A
24V c
24V c
24V c
24V c
5V c
12V c
Description
ABL8MEMpppp
7 1
ABL7RM24025
2
1
5
4
6
2
1
2
3
4
5
14 AWG (2.5 mm2) screw terminal for connection of the AC input voltage
Output voltage adjustment potentiometer
14 AWG (2.5 mm2) screw terminal for connection of the output voltage
LED indicating presence of the DC output voltage
Channel for through-wiring of the output voltage conductors at the bottom (except
for model ABL7RM24025)
6 Clip-on marker label (except for model ABL7RM24025)
7 Retractable mounting legs for panel mounting
14
Specifications
Technical specifications
Power supply type
Certifications
Conformity to standards
Input circuit
LED indication
Input values
Output circuit
LED indication
Nominal output values
Precision
Holding time
forImax.
Protection
Safety
EMC
Nominal voltage
Limit voltage
Current consumption
Permissible frequencies
Maximum inrush current
Power factor
Efficiency at nominal load
Dissipated power
at nominal load
Hz
A
Voltage (UOut)
Mounting
Operating position
Connections
Environment
> 80%
> 82%
> 84%
3.8
6.6
11.4
V
A
W
V
24 Vdc
0.3
0.6
7
15
Adjustable from 22.8 to 28.8 Vdc
3%
250
u 10
u 150
Permanent
Yes
1.2
30
2.5
60
90 for 1ms
Green LED
Current
Power
Output voltage
Line and load regulation
Residual ripple - noise
UIn = 100Vac
UIn = 230Vac
Against short circuits
Against undervoltages
Thermal
mV
ms
ms
V
Input
AWG
(mm2)
Output
AWG
(mm2)
26 to 14 (2 x 0.14 to 2.5)
screw terminals
On vertical plane
Series
Parallel
Operating temperature
Storage temperature
Relative humidity
Degree of protection
Vibration per to EN 61131-2
Protection class according to VDE 0106 1
Dielectric strength 50 Hz for
Input/output
1min
Input fuse incorporated
Emissions
according to EN 61000-6-3
Radiation
Conducted on the power line
Harmonic currents
Immunity
according to EN61000-6-2
85 to 264 Vac
No
100 to 240 Vac
85 to 264 Vac
120 to 250 Vdc (1)
Electrostatic discharge
F (C)
F (C)
V rms
200
< 19
IEC/EN 61000-4-2
(4 kV contact/8kVair)
15
Specifications (continued)
Technical specifications
Power supply type
Certifications
Conformity to standards
Input circuit
ABL8MEM05040
ABL8MEM12020
cULus 508, cCSAus (CSA22.2 n950-1), TV EN 60950-1, e, CTick, RoHS
IEC/EN 60950-1, SELV
IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61204-3, EN 55022 Class B
Safety
EMC
LED indication
No
100 to 240 Vac
85 to 264 Vac
120 to 250 Vdc (1)
0.55 (100Vac)
0.35 (240Vac)
47 to 63
20
> 0.5
> 75%
> 80%
6.7
6.2
Nominal voltage
Limit voltage
Current consumption
Permissible frequencies
Maximum inrush current
Power factor
Efficiency at nominal load
Dissipated power
at nominal load
Hz
A
Voltage (UOut)
Current
Power
Output voltage
Line and load regulation
Residual ripple - noise
V
A
W
V
mV
Green LED
5 Vdc
4
20
Adjustable from 4.75 to 6.25
3%
250
Holding time
for Imax
UIn min
ms
u 10
Protection
Input values
Output circuit
LED indication
Nominal output values
Precision
Mounting
Operating position
AWG
(mm2)
Output
AWG
(mm2)
Connections
Environment
On vertical plane
Series
Parallel
Operating temperature
Storage temperature
F (C)
F (C)
Degree of protection
Vibration
Protection class according to VDE 0106 1
Dielectric strength
Input/output
50 Hz for 1min
Input fuse incorporated
V rms
12 to 15 Vdc
2.1
25
Adjustable from 11.4 to 15
Permanent
Input
Connections
0.6 (100Vac)
0.35 (240Vac)
16
Specifications (continued)
Output specifications
P/Pn (%)
100 %
30 %
- 13 (- 25)
23 (- 5)
59 (15)
95 (35)
131 (55)
1 With an ABL7RM24025
2 With an ABL8MEMppppp
Temporary overloads
The ABL8MEMpppp Modular range of power supplies have an energy reserve that can be used to supply the
application with 125% to 140% of the nominal output current for a maximum of 1minute, depending on the model.
+
1
ABL7RM
ABL8MEM
ABL7RM
ABL8MEM
ABL7RM
ABL8MEM
ABL7RM
ABL8MEM
Parallel connection
1
24 Vdc/2 x I out
2 x 24 Vdc/I out
1 Two shottky diodes, Imin = power supply In, and Vmin = 50 V
Family
Series
Parallel
ABL7RM / 8MEM
2 products max.
2 products max.
17
Protection,
wiring diagrams
Type of protection
Thermal-magnetic circuit-breaker
ABL8MEM05040
Class CC fuse
GB2 (IEC)
C60N (IEC)
C60N (UL/CSA)
GB2pp07 (1)
24581
24517
2A
GB2pp08 (1)
24582
24518
3A
ABL8MEM12020
ABL8MEM24003
ABL8MEM24006
ABL8MEM24012
ABL7RM24025
1/L1
GB2CSpp
2/T1
1/L1
2/T1
3/L2
3/L2 (13)
4/T2 (14)
4/T2
1/L1
18
GB2DBpp
1/L1
GB2CDpp
2/T1
GB2CBpp
2/T1
Wiring diagrams
References,
dimensions,
wiring diagrams
References
Input voltage Secondary
Output
voltage
Reset
Nominal
power
Nominal
current
Conforming
tostandard
IEC/EN
61000-3-2 (1)
Reference
Weight
lbs
(kg)
5V c
20W
4A
Automatic
Not applicable
ABL8MEM05040
0.51
(0.23)
12V c
25W
2A
Automatic
Not applicable
ABL8MEM12020
0.50
(0.23)
24V c
7W
0.3A
Automatic
Not applicable
ABL8MEM24003
0.28
(0.13)
15W
0.6A
Automatic
Not applicable
ABL8MEM24006
0.29
(0.13)
30W
1.2A
Automatic
Not applicable
ABL8MEM24012
0.51
(0.23)
60W
2.5A
Automatic
Not applicable
ABL7RM24025
0.71
(0.32)
Order in
multiples of
Unit reference
ABL8MEM05040/12020/24012
ABL8MEM24003/24006
Designation
Use
LAD90
Weight
lbs
(kg)
0.07
(0.03)
(1) Due to their power < 75 W, the Modular range of power supplies is not subject to the requirements of
standard IEC/EN 61000-3-2.
Approximate dimensions
a
a1
ABL8MEM05040
2.10 (53)
1.65 (42)
ABL8MEM12020
2.10 (53)
1.65 (42)
ABL8MEM24003
1.40 (36)
0.94 (24)
ABL8MEM24006
1.40 (36)
0.94 (24)
ABL8MEM24012
2.10 (53)
1.65 (42)
ABL7RM24025
2.83 (72)
2.36 (60)
3.543 (90)
3.937 (100)
4.331 (110)
1.732 (44)
2.322 (59)
0.157 (4)
a1
a
in (mm)
Wiring diagrams
+
+
ABL8MEM2400p
19
Introduction,
description
c
ABL8REM24030
Twido
The Optimum range of Phaseo power supplies delivers a voltage that is precise to
3%, whatever the load and whatever the type of line supply, within a range of85 to
264Va. Conforming to IEC standards and UL, CSA and TUV certified, they are
suitable for global use. They have overload and short-circuit protection.
ABL8REM power supplies do not have anti-harmonic filters and do not satisfy the
requirements of standard IEC/EN 61000-3-2 concerning harmonic pollution.
ABL7RP power supplies, however, are equipped with a PFC (Power Factor
Correction) filter, thus ensuring compliance with standard IEC/EN 61000-3-2.
The Optimum range of Phaseo power supplies includes protection devices to help
ensure optimum performance of the automation system with an automatic reset
mode on elimination of the detected fault.
In the event of an overload or short-circuit, the integrated protection interrupts the
current supply before the output voltage drops below19V c. The protection device
resets itself automatically on elimination of the detected fault, which avoids having to
take any action or change a fuse.
All products are equipped with an output voltage adjustment potentiometer in order
to be able to compensate for any line voltage drops in installations with long
cable runs.
These power supplies are designed for direct mounting on 35 and 75mm DIN rails.
There are four references available in the Optimum range of Phaseo power
supplies:
bb ABL8REM24030
bb ABL8REM24050
bb ABL7RP1205
bb ABL7RP4803
1
2
3
4
5
6
7
20
72W
120W
60W
144W
3A
5A
5A
3A
24 V c
24 V c
12 V c
48 V c
Description
1 14 AWG (2.5 mm2) enclosed screw terminals for connection of the input voltage
(single-phase N-L1, phase-to-phase L1-L2 (1))
2 Protective glass flap
3 Input voltage status LED (orange).
4 Output DC voltage status LED (green).
5 Locking catch for the glass flap (sealable)
6 Clip-on marker label.
7 Output voltage adjustment potentiometer
8 14 AWG (2.5 mm2) enclosed screw terminal block for connection of the DC
output voltage
(1) 240 V a nominal
Specifications
Technical specifications
Type of power supply
Certifications
Conformity to
standards
ABL7RP1205
ABL7RP4803
ABL8REM24030
ABL8REM24050
cULus 508, cCSAus (CSA22.2 n950-1), File Class, TV 60950-1, e, CTick, RoHS
IEC/EN 60950, IEC/EN 61496-1-2, SELV
IEC/EN 60950, SELV
EN 50081-1, IEC 61000-6-2 (EN 50082-2)
Safety
EMC
Input circuit
LED indication
Input values
Nominal voltage
Limit voltage
Current
consumption
A
A
Hz
A
Voltage (UOut)
Current
Power
Output voltage
V
A
W
Output circuit
LED indication
Nominal output
values
Precision
V
mV
ms
ms
Input
Output
Mounting
Operating position
Connections
Degree of protection
Environment
On DIN rail
On vertical plane
Series
Parallel
Operating temperature
Storage temperature
Maximum relative humidity
Vibration per to EN 61131-2
Protection class according to VDE 0106 1
Dielectric strength
Input/output
50 and 60 Hz for 1 min Input/ground
Output/ground (and output/output)
Input fuse incorporated
Emissions
according to EN
Conducted/radiated
61000-6-3
Immunity
according to
Electrostatic discharge
EN 61000-6-2
Radiated electromagnetic fields
Induced electromagnetic fields
Rapid transients
Surges
Primary outages
AWG
(mm2)
Orange LED
100 to 240 Vac
compatible with 110 to 220 Vdc (1)
85 to 264 Vac
compatible with 100 to 250 Vdc (1)
0.4
0.6
0.8
1
47 to 63
30
0.98 approx.
> 85%
10.6
25.4
Green LED
12 Vdc
48 Vdc
5
3
60
144
Adjustable from
Adjustable from
12 to 14.4 Vdc
48 to 57.6 Vdc
3%
< 200 (peak-peak)
20
20
Permanent/automatic or manual restart
1.1 In
Tripping if UOut > 1.5 Un
Tripping if UOut < 0.8 Un
0.65 approx.
12.7
21.2
24 Vdc
3
72
5
120
10
10
Permanent/automatic restart
21
Specifications (continued)
Output specifications
Derating
The ambient temperature is a determining factor which limits the power that an
electronic power supply can deliver continuously. Excessively high temperatures
around the electronic components significantly reduce their life.
The nominal ambient temperature for the Optimum range Phaseo power supplies
is 122F (50C). Above this temperature, derating is necessary up to a maximum
temperature of 140F (60C).
The graph below shows the power as a percentage of the nominal power that the
power supply can deliver continuously, depending on the ambient temperature.
140
120
100
80
1
60
50
40
20
0
32 (0)
50 (10)
68 (20)
86 (30)
104 (40)
122 (50)
140 (60)
158 (70)
1.97
(50)
General rules
0.59
(10)
AUTO
MANU
0.59
(10)
1.97
(50)
+ +
in (mm)
22
Intensive operation
Parallel connection to
increase the total power
In all cases, there must be adequate convection around the products to assist
cooling. There must be sufficient clearance around the Optimumrange Phaseo
power supplies:
bb 1.97 inches (50mm) above and below
bb 0.59 inches (15mm) on the sides
Specifications (continued)
Temporary overloads
ABL8REM240pp / ABL7RPpppp
ABL8REM / ABL7RP
U out
I out
T (ms)
20
I out:(0...100 %)
18
24 Vdc
16
19 Vdc
14
12
10
0
I out
In 1.1 x In
1.2
1.3
1.4
1.5
1.6
1.7
1.8
x In
Parallel connection
+
1
ABL7RP
ABL8REM
ABL7RP
ABL8REM
ABL7RP
ABL8REM
ABL7RP
ABL8REM
1
24 Vdc/2 x I out
2 x 24 Vdc/I out
1 Two shottky diodes, Imin = power supply In, and Vmin = 50 V
Family
Series
Parallel
ABL8REM / 7RP
2 products max.
2 products max.
T (ms)
20
I out:(0...100 %)
18
16
14
12
I out
10
0
1.2
1.3
1.4
1.5
1.6
1.7
1.8
x In
23
Protection,
wiring diagrams
100V a
Type of protection
Thermal-magnetic
circuit-breaker
240V a
GB2 (IEC)
C60N (IEC)
C60N (UL)
ABL7RP1205
GB2pp06 (1)
24580
24516
ABL8REM24030
GB2pp07 (1)
ABL8REM24050
ABL7RP4803
Class CC
fuse
Thermal-magnetic
circuit-breaker
Class CC
fuse
GB2 (IEC)
C60N (IEC)
C60N (UL)
2A
GB2pp06 (1)
24580
24516
1A
24581
24517
2A
GB2pp06 (1)
24580
24516
1A
GB2pp07 (1)
24581
24517
2A
GB2pp06 (1)
24580
24516
1A
GB2pp07 (1)
24581
24517
2A
GB2pp06 (1)
24580
24516
1A
24
1/L1
3/L2
2/T1
1/L1
4/T2
1/L1
2/T1
GB2CSpp
2/T1
3/L2 (13)
4/T2 (14)
GB2Dpp
1/L1
GB2CDpp
2/T1
GB2CBpp
References,
dimensions,
wiring diagrams
Secondary
Output
voltage
Reset
Nominal
power
Conforming Reference
to standard
CEI/EN
61000-3-2
Nominal
current
Weight
lbs
(kg)
ABL7RP1205/4803
12V c
60W
5A
Automatic or Yes
manual
ABL7RP1205
2.37
(1.08)
24V c
72W
3A
Automatic
No
ABL8REM24030
1.21
(0.55)
120W
5A
Automatic
No
ABL8REM24050
1.75
(0.79)
144W
2.5A
Automatic or Yes
manual
ABL7RP4803
2.37
(1.08)
48V c
ABL8REM24050
Approximate dimensions
ABL8REM24030
ABL7RP1205/4803
4.92
(125)
ABL7RPpppp
Common side view
Mounted on 35 and 75 mm DIN rails
1.062
(27)
4.724
(120)
ABL8REM24050
4.724
(120)
ABL8REM24030
4.724
(120)
100 to 240V a
-15%, +10%
50/60Hz
2.125
(54)
2.125
(54)
in (mm)
Wiring diagrams
N/
ABL8REM24050
ABL8REM24030
L/+
ABL7RP1205 / 48030
25
Introduction
c
ABL8RPS24050
Modicon M340
automation platform
26
Introduction (continued),
description
ABL8WPS24200
A range of function modules also allows functions to be added to the Universal range
of Phaseo power supplies so as to help ensure continuity of service:
c
Modicon Premium
automation platform
Description
Universal range of power supplies
1
2
3
4
5
6
7
10
11
27
Specifications
Technical specifications
Type of power supply
ABL8RPS24030
Certifications
Conformity to standards
Input circuit
Input values
phase-to-neutral (N-L1)
or phase-to-phase
(L1-L2)
Nominal voltage
100 to 120/
200 to 240Vac
Limit voltage
85 to 132/
170 to 264Vac
Permissible frequencies
Hz
47 to 63
30 for 2 ms max.
Power factor
>87%
W
Current (green, orange, and red), voltage (green, red, and off)
Relay
24 Vdc
10
20
Power
72
120
240
480
mV
UIn = 100Vac
ms
u 20
UIn = 240Vac
ms
u 40
UIn = 400Vac
ms
u 120
Against overloads
Against overvoltages
30 to 32Vdc
Against undervoltages
Thermal
Yes
LED Descriptions
11
U out
/
/
/
28
14
I out
21.6 V y Uout
Iout y In
In y Iout
Uout < 7 V
Green
Orange
Red
57.6
Current
OFF
31
Protection
>88%
15.5
7.8
Output circuit
Precision
ABL8RPM24200
Safety
Anti-harmonic filtering
ABL8RPS24100
EMC
Diagnostics
ABL8RPS24050
Specifications (continued)
Connections
Mounting
ABL8RPS24030
Output
AWG
(mm2)
Diagnostic relay
AWG
(mm2)
On DIN rail
in/mm
Protection class
Dielectric strength
50Hz for 1min
Immunity
according to
EN61000-6-2 and GL
Series
Possible
Parallel
Possible
IP20 conforming to IEC 60529
Operating temperature
F (C)
Storage temperature
F (C)
According to VDE01061
Class I
Input/output
V rms
4000 Vac
3000 Vac
Input/ground
V rms
3500 Vac
2500 Vac
Output/ground
V rms
500 Vac
ABL8RPM24200
Vertical
Degree of protection
Environment
ABL8RPS24100
Input
Operating position
Connections
ABL8RPS24050
AWG
(mm2)
No
Radiation
Harmonic currents
IEC/EN 61000-3-2
Electrostatic discharge
Rapid transients
Surges
Primary outages
29
Specifications (continued)
Technical specifications
Type of power supply
Certifications
Conformity to standards
Input circuit
ABL8WPS24200
ABL8WPS24400
CB scheme EN60950-1, cULus 508, cCSAus, e, RoHS
EN60950-1, EN61204, SELV
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61204-3
Safety
EMC
LED indication
Input values
3phases (L1-L2-L3)
Nominal values
Permissible values
Permissible frequencies
Maximum inrush current
Power factor
Efficiency at nominal load
Dissipated power at nominal load
V
V
Hz
A
Anti-harmonic filtering
Operating mode in the event of phase failure
Output circuit
mV
ms
u 18
V
A
W
A
V
V
V
Connections
AWG
(mm2)
Output
AWG
(mm2)
On DIN rail
Series
Parallel
Degree of protection
Operating temperature
Storage temperature
Environment
Maximum relative humidity
Vibration per to EN 61131-2
Protection class according to VDE 01061
Input/output
Dielectric strength
Input/ground
50Hz for 1min
Output/ground
Input fuse incorporated
Radiation
Emissions
according to
Conducted on the power line
EN 61000-6-3
Harmonic currents
Electrostatic discharge
Radiated electromagnetic fields
Immunity
Induced electromagnetic fields
according to
Rapid transients
EN61000-6-2 and GL
Surges
Primary outages
30
u 14
Input
Diagnostic relay
Mounting
Operating position
380-500Vac
320-550Vac
47 to 63
25 for 2 ms max.
0.65
0.85
>92%
38.4
76.8
Yes, via integrated PFC passive filter
Operation possible for a few minutes then protection trips
AWG
14 (2 x 2.5) removable screw terminal block
(mm2)
in (mm) 1.38 x 0.30 and 1.38 x 0.59 (35 x 7.5 and 35 x 15)
Vertical
Possible
Possible
IP20 conforming to IEC 60529
F (C) -13 to 140 derating from 122 F (-25 to +60 derating from 50C)
F (C) -40 to 158 F (-40 to +70 C)
90% during operation, 95%in storage
3 to 11.9Hz, amplitude 0.14 in (3.5mm); and 11.9 to150Hz, acceleration 2g
Class I
V rms 4000 Vac
V rms 3500 Vac
V rms 500 Vac
No
EN 55022 Class B and GL levels
EN 55022 Class B and GL levels
IEC/EN 61000-3-2
IEC/EN 61000-4-2 (6 kV contact/8 kV air)
IEC/EN 61000-4-3 level 3 (10 V/m)
IEC/EN 61000-4-6 level 3 (10 V/m)
IEC/EN 61000-4-4 (4 kV)
IEC/EN 61000-4-5 (1 kV)
IEC/EN 61000-4-11 (voltage dips and interruptions)
Specifications (continued)
Output specifications
Derating
The ambient temperature is a determining factor which limits the power that an
electronic power supply can deliver continuously. Excessively high temperatures
around the electronic components significantly reduce their life.
The nominal ambient temperature for the Universal range of Phaseo power
supplies is 122F (50C). Above this temperature, derating is necessary up to a
maximum temperature of 140F (60C).
The graph below shows the power as a percentage of the nominal power that the
power supply can deliver continuously, depending on the ambient temperature.
140
120
100
80
1
60
50
40
20
0
32 (0)
50 (10)
68 (20)
86 (30)
104 (40)
122 (50)
140 (60)
158 (70)
1.97
(50)
General rules
AUTO
MANU
0.39
(10)
+ +
1.97
(50)
0.39
(10)
in (mm)
Intensive operation
Mounting
In all cases, there must be adequate convection around the products to assist
cooling. There must be sufficient clearance around the Universalrange Phaseo
power supplies:
bb 1.97 inches (50mm) above and below
bb 0.39 inches (10mm) on the sides
31
Specifications (continued)
bb Automatic reset protection mode (current limiting): If the output current exceeds
approximately 1.2 In, the output current is limited to this value. The value of the
output voltage can then be less than 21V but the diagnostic relay opens, allowing
the anomaly to be fed back to the automation system. This prevents feedback of
any undefined logic state. On elimination of the overload, the output voltage reverts
to its preset value.
bb Manual reset protection mode (undervoltage detection): If the output current
exceeds approximately 1.2 In, the power supply stops completely before the output
voltage drops below 21V and no longer delivers any current. The detected fault is
stored in memory as long as voltage is present at the power supply primary. After
the primary is de-energized for a few seconds, the power supply will become
operational again if the cause of the detected fault has been removed.
In both these modes, any overload of less than 1.5 In and lasting less than 4 s will be absorbed
by the boost circuit, and the voltage delivered will stay within the specified limits (adjustment
voltage +/- 3%).
Load limit
Manual reset protection mode
ABL8RPM24200 / ABL8RPS24ppp / ABL8WPS24ppp
U out
U out
28.8
28.8
24
Boost 4 s
24
21.6
Boost 4 s
21.6
In
Pout
150 %
100 %
0%
4s
The ABL8RPS / RPM / WPS Universal range of Phaseo power supplies has a
power reserve, allowing them to supply the application with energy up to 1.5times
the nominal current at the intervals illustrated by the graph to the left.
30 s
30 s
When the power supply can no longer cope (repeated overloads, overload duration
>4seconds, power rating >150% of nominal power) the integrated protection trips.
32
Specifications (continued),
protection,
wiring diagrams
Parallel connection
+
1
ABL8RP
ABL8WP
ABL8RP
ABL8WP
ABL8RP
ABL8WP
ABL8RP
ABL8WP
1
24 Vdc/2 x I out
2 x 24 Vdc/I out
Family
Series
Parallel
2 products max.
a 230V
IEC
8RPS24030
GB2/GV2
8WPS24200
IEC
GB2CD08 4 A
4A
GB2CD07 2 A
2A
GV2 RT06 (1) 2 A
2A
(8 x 32)
(10,3 x 38,1) (10,3 x 38,1)
GB2CD12 6 A
6A
GB2CD08 4 A
4A
GV2 RT07 (1) 4 A
4A
(8 x 32)
(10,3 x 38,1) (10,3 x 38,1)
GB2CD16 10 A
10 A
GB2CD12 6 A
6A
(8 x 32)
C60N
GB2/GV2
2A
2A
(10,3 x 38,1) (10,3 x 38,1)
GB2/GV2
GB2/GV2
GB2/GV2
C60N
8WPS24400
UL / CSA (2)
2A
GV2 RT06 (1) 2 A
2A
(8 x 32)
(10,3 x 38,1) (10,3 x 38,1)
C60N
8RPM24200
UL / CSA (2)
2A
GB2CD07 2 A
C60N
8RPS24100
a 400V
IEC
GB2CD07 2 A
C60N
8RPS24050
UL / CSA (2)
GV2 ME06
GB2/GV2
C60N
GV2 ME07
4A
4A
(10,3 x 38,1) (10,3 x 38,1)
(1)
ABL8RP
ABL8WP
Wiring diagrams
1/L1
3/L2
5/L3
1/L1
3/L2
5/L3
6/T3
2/T1
4/T2
6/T3
GV2MEpp
4/T2
1/L1
2/T1
GV2RTpp
2/T1
3/L2 (13)
4/T2 (14)
GB2CDpp
33
References
Secondary
Output
voltage
Reset
Nominal
power
Nominal
current
Conforming Reference
tostandard
IEC/EN
61000-3-2
Weight
lbs (kg)
24 to 28.8V 72W
c
120W
3A
Auto/man
Yes
ABL8RPS24030
1.58 (0.72)
5A
Auto/man
Yes
ABL8RPS24050
1.88 (0.85)
240W
10A
Auto/man
Yes
ABL8RPS24100
3.50 (1.59)
20A
Auto/man
Yes
ABL8RPM24200
6.20 (2.81)
20A
Auto/man
Yes
ABL8WPS24200
4. 67 (2.12)
40A
Auto/man
Yes
ABL8WPS24400
7.00 (3.18)
24 to 28.8V 480W
c
960W
Function
Use
ABL8WPS24200
Continuity after Paralleling and redundancy of the
a malfunction
power supply to help ensure
(6)
uninterrupted operation of the
application excluding AC line failures
and application overloads
Designation
Reference
Weight
lbs (kg)
Buffer module
ABL8BUF24400
3.00 (1.36)
ABL8BBU24200
2.37 (1.08)
ABL8BBU24400
2.63 (1.19)
ABL8BPK24A03
10.69 (4.85)
ABL8BPK24A03
16.98 (7.70)
ABL8BPK24A12
25.35 (11.50)
Redundancy module
ABL8RED24400
1.27 (0.58)
Secondary
Reference
Output
voltage
2.2A
5 to 6.5Vc 6 A
ABL8DCC05060
1.25 (0.57)
1.7A
7 to 15V c 2A
ABL8DCC12020
1.22 (0.55)
Composition
Reference
ABL8FUS02
Clip-on marker
labels
LAD90
ASI20MACC5
DIN rail
mounting kit
ABL1A02
Cables
SR2CBL01
0.330 (0.150)
SR2USB01
0.330 (0.150)
SR2MEM02
0.022 (0.010)
24Vc
-9%, +24%
Nominal
current
Weight
lbs (kg)
ABL8BBU24200
EEPROM
memory
ABL8RED24400
34
Use
Weight
lbs (kg)
0.066 (0.030)
6/T3
4/T2
2/T1
Dimensions,
wiring diagrams
E1
Approximate dimensions
0.472
(12)
Reference
ABL8RPS24030
ABL8RPS24050
ABL8RPS24100
ABL8RPM24200
ABL8WPS24200
ABL8WPS24400
4.921
(125)
5.629
(143)
L1 N/L2 L3
11
14
0.236
(6)
+IN +OUT
0.236
(6)
a
4.48 (114)
4.48 (114)
5.27 (134)
5.86 (149)
5.86 (149)
5.86 (149)
in (mm)
b
1.73 (44)
2.20 (56)
3.35 (85)
5.71 (145)
3.74 (95)
6.50 (165)
Wiring diagrams
HV
11
14
11
14
+
+
L1
14
11
PFC
+
+
14
11
+
+
PFC
L3
LV
14
11
L3
ABL8WPS24400
+
+
PFC
L2
L1
ABL8WPS24200
HV
ABL8RPM24200
LV
PFC
+
+
+
+
PFC
L2
PFC
ABL8RPS24100
HV
LV
ABL8RPS24050
HV
LV
ABL8RPS24030
L
N
100
120
100
120
200
500
L1
L2
L3
Ph 1
Ph 2
LV
LV C HV
C HV
200
500
L1 L2 L3
3x380 - 500 VAC
200
500
35
Introduction,
description
Description
1
2
3
4
5
6
7
8
36
Specifications
Technical specifications
Converter
Type of module
ABL8DCC05060
Certifications
Conformity to
standards
Input circuit
Input values
Safety
EN60950-1, EN61204
EMC
Nominal voltage
24 to 28.8 Vdc
Limit voltage
22 to 30 Vdc
Yes
Output circuit
Diagnostics
Nominal output
values
Precision
Current
Power
30
24
1 to 3%
mV
Against overvoltages
AWG
(mm2)
24 to 12 (2 x 0.5 to 4)
Output
AWG
(mm2)
24 to 12 (2 x 0.5 to 4)
in (mm) 1.38 x0.30 and 1.38 x 0.59 (35 x 7.5 and 35 x 15)
On DIN rail
Mounted vertically
Mounted horizontally with derating of power
Vertical or horizontal position
from 122 to 140 F (50 to 60C)
40%maximum to 140 F (60C)
Operating position
Degree of protection
Operation
F (C)
Storage
F (C)
Operation
90%
Storage
95%
3 to 11.9 Hz, amplitude 0.14 in (3.5 mm); 11.9 to 150 Hz, acceleration 2g
Protection class
Class III
Input/output
Dielectric strength
Input/ground
50Hz for 1min
Output/ground
Immunity
according to
EN61000-6-2
Input
Connections
Emissions
according to EN
61000-6-3
<100
Permanent, automatic restart
Against overloads
Environment
> 82%
4
Thermal
Mounting
> 80%
7
ABL8DCC12020
V rms
500 Vac
V rms
500 Vac
V rms
500 Vac
Conducted/radiated
EN 55022 - Class B
Electrostatic discharge
Rapid transients
Surges
37
References,
dimensions,
wiring diagrams
DC/DC converters (for use with Universal range of Phaseo power supplies)
Primary (1)
Secondary
Reference
Nominal
current
Weight
lbs
(kg)
2.2A
5 to 6.5 V c 6 A
ABL8DCC05060
0.661
(0.300)
1.7A
7 to 15V c 2A
ABL8DCC12020
0.661
(0.300)
Composition
Unit reference
Replacement part
Designation
ABL8DCC050060/12020
Weight
lbs
(kg)
0.661
(0.300)
ABL8RPp24pp0
In
24 Vdc
Out
Vdc
+
+
Vdc
ABL8DCCppppp
ABL8DCC05060 5 Vdc
ABL8DCC12020 12 Vdc
Approximate dimensions
0.472
(12)
5.63
(143)
4.921
(125)
4.72
(120)
0.236
(6)
+IN +OUT
0.236
(6)
in (mm)
Wiring diagram
ABL8DCC05060 and ABL8DCC12020 Converter modules
38
IN
+
IN
-
OUT
+
OUT
-
Introduction
t
t1
Output voltage
Power supply
ABL8RPS24030
ABL8RPS24050
ABL8RPS24100
ABL8RPM24200
ABL8WPS24200
ABL8WPS24400
39
Introduction (continued)
Output voltage
t2
2
1
Minutes
Hours
5
10 30 1
2
3
4
5
6
7
8
9
10 15 20 30 40 50 1
2
3
5
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5
2A
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+6 2+6
3A
4A
5A
2+4
6A
2+4
7A
2+4
8A
2+4
10A
2+4 2+4
15A
2+4 2+4
20A
2+5 2+5
25A
30A
35A
40A
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+6 2+6 2+6
+6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+5 2+6 2+6 2+6
+6 +6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+6 2+6 2+6 2+6
+6 +6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6
+6 +6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6
+6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+5 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6
+6 +6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+5 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6
+6 +6 +6
2+4 2+4 2+4 2+4 2+4 2+4 2+4 2+5 2+5 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6 2+6 2+6
+6 +6 +6
2+5 2+5 2+5 2+5 2+5 2+5 2+5 2+5 2+6 2+6 2+6 2+6 2+6 2+6 2+6 2+6 2+6
+6 +6 +6
3+5 3+5 3+5 3+5 3+5 3+5 3+5 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6
+6 +6 +6 +6
3+5 3+5 3+5 3+5 3+5 3+5 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6
+6 +6 +6 +6 +6 +6 +6
3+5 3+5 3+5 3+5 3+5 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6
+6 +6 +6 +6 +6 +6 +6
3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6 3+6
+6 +6 +6 +6 +6 +6 +6
Function modules
40 A Buffer module
20 A Battery Control module
40 A Battery Control module
3.2 Ah Battery module
7 Ah Battery module
12 Ah Battery module
Reference
ABL8BUF24400
ABL8BBU24200
ABL8BBU24400
ABL8BPK24A03
ABL8BPK24A07
ABL8BPK24A12
Code
1
2
3
4
5
6
Note: Several Buffer modules (up to a maximum of three) can be connected in parallel to
increase the immunity time. The times given in the table above (boxes marked 1) should be
multiplied by the number of modules used (2 or 3).
40
Description,
functions
2
3
4
5
6
1
2
3
4
5
6 Removable screw connector for connection of the diagnostic contacts: power supply presence, battery
alarm and presence (terminal block supplied)
7 8 AWG (10mm2) enclosed screw terminals for connection of the24V c output voltage
8 8 AWG (10mm2) enclosed screw terminals for connection of the power supply24V c input voltage
9 8 AWG (10mm2) enclosed screw terminals for connection of the battery voltage24V c input voltage
6
7
8
9
Functions
The Battery Control modules offer a three-color LCD screen and a navigation button that can be used to:
bb Display the status and diagnostic data
bb Access the service and maintenance functions
bb Set the module parameters
These modules also have a diagnostic relay (C/O contacts) relating to:
bb Power supply status
bb Battery module status
bb Alarm
Orange: Warning
Specifications
Technical specifications
Buffer module
Battery Control module
ABL8BBU24400
ABL8BUF24400
ABL8BBU24200
CB scheme EN60950-1, cULus 508, cCSAus, e, RoHS
EN60950-1, EN61204
IEC/EN61000-6-2, IEC/EN61000-6-3
Input circuit
Input values
Output circuit
Nominal output
values
Precision
Holding time
Safety
EMC
Voltage (UOut)
V
A
mV
Max. current
Residual ripple - noise
I = 0.5A
I = 40A
Against short circuits
Protection
V
V
A
V
Nominal voltage
Limit voltage
No-load/On-load/Max. consumption
Activation threshold
Protection against reverse polarity
Dissipated power at nominal load
Power-supplied mode
Battery-backed mode
Against overloads
Against overvoltages
Against undervoltages
Thermal
V
V
Input
Output
Diagnostic relay
On DIN rail
AWG (mm2)
AWG (mm2)
mm2
in (mm)
Operating position
Connections
Series
Parallel
Degree of protection
Operation
Storage
Operation
Environment
Relative humidity
Storage
Vibration according to EN 61131-2
Protection class according to VDE 01061
Charging time
Temperature
F (C)
F (C)
24 to 28.8 Vdc
22 to 30 Vdc
0.1/0.6/40.6
UIn -1 and 22 Vdcmin.
Yes
<15
Nominal mode: UIn -0.25
Buffer mode: UIn -1
40
< 200
6s
0.1 s
Permanent,
automatic restart
> 45 A
Tripping if UOut<19
0.1/1.7/21.7
Adjustable22 to 26 Vdc
0.1/1.7/41.7
<7
<12
40
Yes
Control input
Via LED
LCD screen
Via relay
Diagnostics
Relay characteristic
Dielectric strength
50Hz for 1min
Input/ground
Output/ground
Emissions according Conducted/radiated
to EN61000-6-3
Immunity
according to
EN61000-6-2
42
Electrostatic discharge
Radiated electromagnetic fields
Induced electromagnetic fields
Rapid transients
Surges
V rms
V rms
Specifications (continued)
Technical specifications
Type of Function module
Battery
ABL8BPK24A03
Battery type
Lead-sealed battery
Certifications
Input circuit
Safety
Nominal output
values
Holding time
at20C
0.7
1.2
Conformity pending
Nominal voltage
24 to 28.8 Vdc
Limit voltage
22 to 29 Vdc
Load current
Output circuit
ABL8BPK24A12
Certification pending
Conformity to standards
Input values
ABL8BPK24A07
0.3
Yes
72 max.
Voltage (Un)
24 Vdc
Max. current
32
40
75
Ah
3.2
12
Charging time
Capacity
Maximum
Minimum
min
20 at 0.16A
20 at 0.35A
20 at 0.6A
5 at 8.4A
5 at 18.2A
5 at 31.3A
1 x 20 A
1 x 30 A
2 x 30 A
1 month
3%
3 months
9%
6 months
15%
20 to 8
(4 x 0.5 to 10)
Output
20 to 8
(4 x 0.5 to 10)
Connections
in (mm)
On DIN rail
Mounting
On vertical panel
With 2 screws 5 mm
Operating position
Vertical or horizontal
Series
Parallel
Yes
Degree of protection
Environment
Operation
F (C)
32 to 104 F (0 to +40 C)
Storage
F (C)
Service life
(approximate)
With 4 screws 5 mm
On horizontal panel
Connections
Class III
68 F (20 C)
44,000
77 F (25 C)
31,000
86 F (30 C)
22,000
95 F (35 C)
15,000
104 F (40 C)
11,000
113 F (45 C)
7,300
122 F (50 C)
5,000
43
References,
wiring diagrams
Function modules
Function
Use
Designation
Reference
ABL8BUF24400
Weight
lbs (kg)
ABL8BUF24400
2.645
(1.200)
Battery Control
module
20A output current
ABL8BBU24200
1.102
(0.500)
Battery Control
module, 40A output
current
ABL8BBU24400
1.543
(0.700)
7.716
(3.500)
ABL8BPK24A07
14.330
(6.500)
7 Ah battery module
(2)
ABL8BBU24200
ABL8BBU24200
Description
Composition
Unit reference
ABL8FUS02
Clip-on marker
labels
Order in multiples of
100
LAD90
For ABL8BPK2403
Battery module
ABL1A02
Cables
Connection cable
RS232 3 m
between ABL8BBU and
PC for updating the
USB 3 m
software
Weight
lbs (kg)
0.066
(0.030)
SR2CBL01
0.330
(0.150)
SR2USB01
0.330
(0.150)
SR2MEM02
0.022
(0.010)
ABL8BUF24400
In
Out
24 Vdc
Out
Load saved
24 Vdc
ABL8BBU
UL Listed File E164867 CCN
NMTR
ABL8BPK24App
ABL8BBU24p00
IN
OUT
ABL8RPp24pp0
ABL8WPS24p00
ABL8BUF2440
cULus File E164867 CCN
NMTR and NMTR7
In
Vdc
+
+
Vdc
ABL8BUF24400
ABL8RP p24pp0
ABL8WPS24 p00
24 Vdc
44
24 Vdc
Load saved
Dimensions,
wiring diagrams
Approximate dimensions
ABL8BBU24200 Battery Control module
5.748
(146)
4.921
(125)
5.511
(140)
.236
(6)
.354
(9)
11
6.023 (153)
6.259 (159)
14
3.346
(85)
5.629
(143)
2.204
(56)
.236
(6)
5.551
(141)
.472
(12)
5.944 (151)
6.260 (159)
3.385
(86)
Reference
ABL8BPK24A03
ABL8BPK24A07
ABL8BPK24A12
in (mm)
a
3.83 (97)
5.16 (131)
5.16 (131)
in (mm)
b
7.24 (184)
6.69 (170)
9.29 (236)
c
5.45 (138)
5.98 (152)
6.12 (155)
Wiring diagrams
AB8BUF24400 Buffer module
IN
-
5.551
(141)
5.748
(146)
IN
+
6.023 (153)
6.259 (158)
OUT
+
OUT
-
11
14
IN
+
IN
-
1
OFF
2
1
2 PSU
3
4
5 ALARM
6
7
8
9
2.204
(56)
OUT
+
OUT
-
Terre fonctionnelle
45
Introduction,
description
Description
3
4
5
6
7
8
46
Specifications
Technical specifications
Type of Function module
Redundancy
ABL8RED24400
Certifications
Conformity to
standards
Safety
EN60950-1, EN61204
EMC
EN61000-6-2, EN61000-6-3
Input circuit
Input values
Output circuit
Nominal output
values
2428.8 Vdc
Limit voltage
2230 Vdc
20 per input
Yes
UIn - 0.2
40
Number of channels
Protection
1
Against short circuits
Against overloads
Input
AWG
(mm2)
Output
AWG
(mm2)
(mm2)
2.5
Diagnostic relay
Mounting
in (mm) 1.38 x 0.30 and 1.38 x 0.59 (35 x 7.5 and 35 x 15)
On DIN rail
Operating position
Connections
Parallel
Degree of protection
Environment
Relative humidity
Operation
F (C)
Storage
F (C)
Operation
90%
Storage
95%
Class II
1 LED per input
Green: power supply operational
Via LED
Via relay
Dielectric strength
50Hz for 1min
V rms
No isolation
Input/ground
V rms
500 Vac
Output/ground
V rms
500 Vac
Emissions according
Conducted/radiated
to EN61000-6-3
Immunity
according to
EN61000-6-2
Input/output
EN 55022 - Class B
Electrostatic discharge
Rapid transients
Surges
47
References,
wiring diagrams
Use
Designation
Reference
Weight
lbs (kg)
Paralleling and
redundancy of the
power supply to help
ensure uninterrupted
operation of the
application excluding
AC line failures and
application overloads
Redundancy
module
ABL8RED24400
Composition
Unit reference
Order in multiples
of100
LAD90
1.54
(0.700)
Replacement part
Designation
ABL8RED24400
0.07
(0.030)
ABL 8RPp24pp0
ABL 8WPS24200
ABL8
ABL8
IN2
ABL 8RPp24pp0
ABL8RED24400
ABL 8WPS24200
IN1
IN2
ABL8RED24400
IN1
48
ABL 8RPp24pp0
ABL 8WPS24200
In = 40 A
IN1
IN2
ABL8RED24400
OUT
24 Vdc
24 Vdc
IN2
OUT
OUT
ABL8RED24400
ABL8RED24400
IN1
IN2
In = 40 A
IN1
ABL8
ABL8
In y 20 A
ABL 8RPp24pp0
ABL 8WPS24200
Weight
lbs (kg)
Dimensions,
wiring diagrams
4.921
(125)
5.511
(140)
5.748
(146)
.472
(12)
+
IN 1
.236
(6)
.354
(9)
.236
(6)
In/(mm)
Wiring diagram
ABL8RED24400 Redundancy module
IN1 IN2
+
OUT
+
IN1 IN2
-
OUT
-
11 14
146
(125)
(12)
44
(6)
IN 1
49
Introduction,
description
Introduction
ABL1REM/RPM Phaseo Dedicated range regulated switch mode power supplies
are specially designed to provide the DC voltage necessary for electrical equipment
operating on a safety extra low voltage (SELV). Split into two ranges, they are able
to meet all the needs encountered in standard commercial machines.
These single-phase power supplies, with or without anti-harmonic distortion filter,
conform to world-wide standards. Switch mode technology provides the quality of
the output current with regulation below 3%.
As machine components, ABL1REM/RPM Phaseo Dedicated range power supplies
are easy to install; only the set-up may vary from one application to another. The
ABL1 range has been specially designed for machine manufacturers.
ABL1REM/RPM regulated switch mode power supplies are totally electronic and
regulated. They provide the following benefits:
bb Wide input voltage range from 85 to 264 Va and 120 to 370 Vc (not indicated on
the product).
bb Several products with anti-harmonic distortion input filter.
bb High degree of output voltage stability, adjustable by potentiometer.
bb Built-in thermal overload protection.
bb Conformity to world-wide standards.
bb Conformity to standard EN 55022 class B.
bb UL 508, CSA and TV certifications.
bb Overload and short-circuit protection.
bb Considerably reduced weight.
bb Identical mounting accessories for all models.
ABL1 power supplies for electrical equipment are divided into two ranges:
bb ABL1REM, single-phase:
vv 60 W for the 12 Vc version,
vv 60 W, 100W, 150 W and 240 W for the 24 Vc versions.
bb ABL1RPM, single-phase with anti-harmonic distortion filter:
vv 100 W for the 12 Vc version,
vv 100W, 150 W and 240 W for the 24 Vc versions.
Electromagnetic compatibility
Levels of conducted and radiated emissions are defined in standards EN 55011 and
EN 55022.
The products in the ABL1 range are class B, the strictest level, and can be used
without any restrictions due to their low emissions.
Behavior in the event of short-circuits
ABL1 power supplies are equipped with electronic and thermal overload protection.
This protection resets itself automatically on elimination of the detected fault, which
avoids having to take any action or change a fuse.
Description
50
Specifications
Technical specifications
ABL1REM
ABL1RPM
12050 24025 24042 24062
24100
12083 24042 24062
24100
cULus508, cCSAus, CSA 22.2 n 60950-1, UL 60950-1, TV, CTick, RoHS, e
IEC/EN 60950-1, SELV
EN50081-1, IEC61000-6-2 (EN50082-2), IEC/EN 61000-6-3
IEC/EN 61000-3-2
Input circuit
LED indication
Nominal voltage
Vac
Vdc compatible
UIn = 240 V
Current
consumption
UIn = 100 V
Permissable frequencies
Maximum inrush current
Power factor
Efficiency at nominal load
Dissipated power at nominal load
V
V
A
A
Hz
A
Voltage (UOut)
Current
Power
V
A
W
Limit voltage
Input voltages
Output circuit
LED indication
Nominal output
values
Precision
Holding time
forImax.
Protection
mV
ms
ms
Thermal
Input
Output
AWG
(mm2)
AWG
(mm2)
Series
Parallel
Degree of protection
Overvoltage category
Operating
Storage
Max. relative humidity
Vibrations, perEN61131-2
AccordingtoVDE01061
Temperature
Environment
Protection class
Degree of pollution
Input/output
Input/ground
Output/ground
Input fuse incorporated
Emissions
according to
Conducted/radiated
EN61000-6-3
Dielectric strength
50 and 60 Hz
for1min
Immunity
according to
EN61000-6-2
Electrostatic discharge
Radiated electromagnetic fields
Induced electromagnetic fields
Rapid transients
Surges
Conducted interference
Primary outage
F (C)
F (C)
Vrms
Vrms
Vrms
60
25
37.5
60
Green LED
2 Vdc 24 Vdc
12 Vdc 24 Vdc
5
2.5
4.2
6.2
10
8.3
4.2
6.2
10
60
100
150
240
100
150
240
10.8
10.8
21.626.4
21.626.4
13.2
13.2
3%
< 200 (peak-peak)
u40
u10
Permanent, automatic restart
1.1 to 1.5 In
U > 1.25 UOut
Yes (limiting operation above a temperature between 50 and 60 C, depending on the
load rating)
12 (2 + ground) x 4
12 (2 x 4)
12 (4 x 4)
51
Specifications (continued)
Output specifications
Derating
The ambient temperature is a determining factor which limits the power that an
electronic power supply can deliver continuously. Excessively high temperatures
around the electronic components significantly reduce their life.
ABL1RpM24100 power supplies (240W) are mechanically ventilated from an
ambient temperature > 104F (40C) approx., or for a load rating >90% approx.
The rated ambient temperature for ABL1REM/1RPM power supplies is
122F (+50C). Above this, derating is necessary up to a maximum temperature
of 140F (+60C).
The curves below show the power (in relation to the nominal power) which the
power supply can deliver continuously, according to the ambient temperature.
P/P N
100 %
60 %
Tp (C/F)
32 F
0 C
122 F 140 F
50 C 60 C
P/P N
100 %
60 %
Tp (C/F)
32 F
0 C
113 F 131 F
45 C 55 C
Rise in
output voltage
The total power is equal to the sum of the power supplies used, but the
Parallel connection
maximum ambient temperature for operation is 122 F (50 C).
to increase
To improve heat dissipation, the power supplies must not be in contact
the power
with each other.
Note: See page53 for a schematic drawing of the ABL1 Dedicated Range power supplies.
52
Specifications (continued)
protection
1.97
(50)
1.97
(50)
0.79
(20)
0.79
(20)
in (mm)
1.97
(50)
1.97
(50)
0.59
(1)
In all cases, there must be adequate convection around the products to help ensure
sufficient cooling. There must be a clear space of 1.97in (50mm) above and below
the power supplies, and of 0.79in (20mm) at the sides.
Load limits
U out
24 V
15 V
I out
ABL1
ABL1
x
1.1 In x 1.5 In
Parallel connection
ABL1
ABL1
In
1
24 Vdc / I out
2 X 24 Vdc / I out
1 8
A / 100 V Shottky diode for ABL1REM12050 / 1REM24025 / 1RpM24042
15 A /1 00 V Shottky diode for ABL1RPM12083 / 1RpM24062 / 1RpM24100
a 115 V single-phase
Thermal-magnetic
circuit-breaker
GB2 (IEC)
a 230 V single-phase
Class CC
fuse
C60N (IEC)
C60N (UL)
Thermal-magnetic
circuit-breaker
GB2 (IEC)
Class CC
fuse
C60N (IEC)
C60N (UL)
ABL1REM12050
GB2DB07
24517
2A
GB2DB07
24517
2A
ABL1REM24025
GB2DB07
24517
2A
GB2DB07
24517
2A
U out
ABL1RPM12083
24 V
ABL1REM24042
GB2DB07
24517
2A
GB2DB07
24517
2A
GB2DB07
24517
2A
GB2DB07
24517
2A
15 V
ABL1RPM24042
GB2DB07
24517
2A
GB2DB07
24517
2A
ABL1REM24062
GB2DB07
24517
2A
GB2DB08
24518
4A
ABL1RPM24062
ABL1REM24100
ABL1RPM24100
I out
0
In
GB2DB07
24517
2A
GB2DB08
24518
4A
GB2DB08
24518
4A
GB2DB10
17454
6A
24518
4A
GB2DB10
17454
6A
x
GB2DB08
1.1 In x 1.5 In
53
References,
wiring diagrams
References
ABL1REM24025
ABL1RpM24042
Output Nominal
voltage power
Nominal
current
Auto-protect
reset
12Vc 60W
5A
Automatic
Conforming
Reference
tostandard
IEC/EN61000-3-2
No
ABL1REM12050
24Vc 60W
2.5A
Automatic
No
ABL1REM24025
1.19
(0.54)
100W
4.2A
Automatic
No
ABL1REM24042
1.62
(0.73)
6.2A
Automatic
No
ABL1REM24062
2.49
(1.13)
10A
Automatic
No
ABL1REM24100
2.35
(1.07)
Weight
lbs (kg)
1.25
(0.57)
Output Nominal
voltage power
Nominal
current
Auto-protect
reset
12Vc 100W
8.3A
Automatic
Conforming
Reference
tostandard
IEC/EN61000-3-2
Yes
ABL1RPM12083
24Vc 100W
4.2A
Automatic
Yes
ABL1RPM24042
6.2A
Automatic
Yes
ABL1RPM24062
10A
Automatic
Yes
ABL1RPM24100
Sold in
lots of
5
Unit
reference
ABL1A01
Weight
lbs (kg)
1.62
(0.73)
1.62
(0.73)
2.49
(1.13)
3.05
(1.38)
ABL1RpM24100
Mouting accessories
Description
Wiring diagrams
ABL1REM12050, ABL1REM24025
ABL1A02
54
ABL1REM24042, ABL1REM24062,
ABL1REM24100
ABL1A02
ABL1RPMppppp
Filter
ABL1A01
Weight
lbs (kg)
0.187
(0.085)
0.077
(0.035)
Dimensions,
mounting
Approximate dimensions
ABL1RpMppppp
L
0.10
2.5
0.31
8
3.23
82
3.86
98
0.31
8
0.33
8.5
ABL
ABL1REM12050
ABL1REM24025
ABL1REM24042
ABL1REM24062
ABL1REM24100
ABL1RPM12083
ABL1RPM24042
ABL1RPM24062
ABL1RPM24100
L
5.91 (150)
5.91 (150)
7.87 (200)
7.87 (200)
7.87 (200)
7.87 (200)
7.87 (200)
7.87 (200)
7.87 (200)
P
1.50 (38)
1.50 (38)
1.50 (38)
1.97 (50)
2.56 (65)
1.50 (38)
1.50 (38)
1.97 (50)
2.56 (65)
a
5.67 (144)
5.67 (144)
7.64 (194)
7.64 (194)
7.64 (194)
7.64 (194)
7.64 (194)
7.64 (194)
7.64 (194)
in (mm)
ABL1A02
0.79
20
0.39
10
2.56
65
32.6 0.15
2.13
54
0.71
18
1.42
36
2.17
55
1.42
36
0.87
22
4.57
116
36.2 0.15
ABL1A01
40
Mounting
ABL1RpMppppp
Direct mounting by 2 M4 x 20 screws
a
0.33
8.5
M4 x 20/# 8 x 32 (B)
0.71
18
3.23
82
M4 x 20/# 8 x 32 (A)
0.31
8
0.31
8
ABL1REM12050
ABL1REM24025
2.95
75
2.95
75
0.88
22.25
0.10
2.5
M4x8
M4x8
M4x8
1.42
36
2.17
0.45 55
11.5
3x4
0.39
10
1.49
2.28 38
58
ABL1RPM12083
ABL1RpM24042 / 062 / 100
1.18
30
0.79
20
M4x8
M4x8
2.32
59
M4x8
1.54
39
M4x8
c b
"
"
55
Introduction
ASIABLB300p
Operating on a 100 to 240 V a supply, this power supply delivers a voltage of
30Vc. Available in 2.4 and 4.8 A ratings, the outgoing terminal block allows the
cable to be connected separately to the ASInterface interface modules and to the
ASInterface master. Input and output LEDs allow fast and continuous diagnostics.
ASIABLB3002
ASIABLD300p
Operating on a 100 to 240 V a supply, this power supply delivers a voltage of
30Vc. Available in 2.4 and 4.8 A ratings, it allows diagnosis and management of
ground detected faults on AS-Interface interface modules. In the event of a ground
detected fault, the Phaseo power supply stops dialog on the AS-Interface cabling
system and puts the installation in a fallback condition. Restarting is only possible
after deliberate acknowledgement of the detected fault. Two inputs/outputs enable
dialog with a processing unit. The outgoing terminal block is used to connect the
AS-Interface cable separately to the interface modules and master modules. Input,
output and ground detected fault LEDs allow fast and continuous diagnostics.
ASIABLD3004
ASIABLM3024
Operating on a 100 to 240 V a supply, this product provides two separate power
supplies, which are totally independent in the way they operate.
Two output voltages 30 V/2.4 A (AS-Interface line supply) and 24 V/3 A are
available, making it possible to supply the control equipment without an additional
power supply. Input and output LEDs allow fast and continuous diagnostics.
ASIABLM3024
56
Specifications
Technical specifications
Type of power supply
Functions
Product certifications
Conforming to standards
ASIABLD3004
ASIABLM3024
30 V c 24 V c
supply supply
Safety
EMC
Low frequency
harmonic currents
Input circuit
LED indication
Input voltage
Rated values
Permissible values
Current consumption
Permissible frequencies
Current at switch-on
Power factor
Efficiency at nominal load
Dissipated power at nominal
load
V
V
A
Hz
A
%
W
Orange LED
a 100 to 240
a 85 to 264
0.5
47 to 63
< 30
0.65
> 83
14.7
Voltage (UOut)
Current
Power
Adjustable output voltage
V
A
W
V
Green LED
30 (AS-Interface)
2.4
4.8
72
144
mV
ms
3%
300 - 50
u10
0.5
29.5
14.7
29.5
2.4
72
4.8
144
> 83
14.7
> 80
36
c 30
2.4
72
c 24
3
72
100 to
120 %
U>
1.2 Un
U<
0.95 Un
U>
1.5 Un
U<
0.8 Un
Output circuit
LED indication
Nominal output values
Precision
Holding time
for I max
Protection
Against short-circuit
Against overload
Against overvoltage
Against undervoltage
Operating specifications
Connections
Environment
Operating position
MTBF
Dielectric strength 50Hz
during 1 min
Input fuse incorporated
Input
Output
Operating temperature
Storage temperature
Maximum relative humidity
Degree of protection
Vibrations
mm2
mm2
C
C
Emission
Conducted/radiated
according to EN61000-6-3
Immunity
Electrostatic discharge
according to IEC/EN61000-6-2 Radiated lectromagnetic field
Induced electromagnetic field
Rapid transients
Primary outages
57
Specifications (continued),
functions
Output specifications
Derating
The ambient temperature is a determining factor which limits the power that an
electronic power supply can deliver continuously. If the temperature around the
electronic components is too high, their life will be significantly reduced.
The graph below shows the power (in relation to the nominal power) which the power
supply can deliver continuously, according to the ambient temperature.
P/Pn (%)
140
120
100
80
60
40
20
0
32 (0)
50 (10)
68 (20)
86 (30)
Function diagram
10
N
6
7
5
1
1
2
8
9
24 V
AS-i : 2,4 A
4
3
or
10
GND
Supply
AS-i + AS-i , and GND (4)
AS-i +
AS-i
AS-i + AS-i
ON/OFF DDT
6
7
8
9
(1)
Reset
(1)
Reset
(1)
Test
(3)
(2)
(3)
(2)
(3)
(2)
(3)
(2)
Detected Fault
AS-i
Detected Fault +
Detected Fault
OFF
ON
Input at state 0 or contact open
Input at state 1 or contact closed
LED off
LED on
___________________________________________________________________________
(1) 30 ms min.
(2) 15 ms.
(3) 20 ms.
(4) Warning: the ground fault detector will only operate if the ground (GND) terminal is
connected.
d Warning
bb The ground (GND) (4) connection must be made. In the event of disconnection, the built-in
detector becomes inoperative. To obtain ground connection diagnostics, it is recommended that
an ASIABLD300p power supply be used with built-in insulation control.
bb An appearence of accidental ground detected fault triggers, in the following cases, the
activationg of built-in protection:
vv case 1: detected fault between AS-i + and ground,
vv case 2: detected fault between AS-i - and ground,
vv case 3: detected fault between sensors/actuators (supplied by ASIABLD300p) and ground.
In cases 1 and 2 with switch 1 ON -> OFF: maintain of detected fault, any exchange between
master and slaves.
In case 3 with switch 1 ON -> OFF: restart of exchanges between master and slaves but the
states of inputs/outputs of affected module are not guaranted.
58
Protection,
references,
dimensions,
wiring diagrams
a 115 V single-phase
a 230 V single-phase
Power supply
Thermal-magnetic
supplementary breaker (1)
Single-pole
GB2CBpp
2-pole
GB2DBpp
C60N
ASIABLB3002
GB2 pB07
MG24517 (2)
ASIABLB3004
GB2 pB08
MG24518 (2)
ASIABLD3002
GB2 pB07
MG24517 (2)
ASIABLD3004
GB2 pB08
MG24518 (2)
ASIABLM3024
GB2 pB07
MG24517 (2)
(1) Single-phase protection, replace p by C; 2-pole protection, replace p by D.
(2) UL certified circuit breaker.
Class CC Thermal-magnetic
fuse supplementary breaker (2-pole)
2A
4A
2A
4A
2A
GB2DBpp
GB2 DB06
GB2 DB07
GB2 DB06
GB2 DB07
GB2 DB06
Class CC
fuse
C60N
MG24516 (2)
MG17453 (2)
MG24516 (2)
MG17453 (2)
MG17453 (2)
2A
2A
2A
2A
2A
References
Input voltage
Secondary
Output
Nominal
voltage
power
Single phase (N-L1) or 2-phase (L1-L2)
a100 to 240V c30V
72W
-15%, +10%
50/60Hz
144W
c30V
c24V
Auto-protect
Nominal reset
current
Weight
2,4A
Auto
No
ASIABLB3002
4,8A
Auto
No
ASIABLB3004
72W
2,4A
Auto
Yes
ASIABLD3002
144W
4,8A
Auto
Yes
ASIABLD3004
72W
72 W
2,4A
3A
Auto
No
ASIABLM3024
lbs (kg)
1.76
(0.800)
2.87
(1.300)
1.76
(0.800)
2.87
(1.300)
2.87
(1.300)
ASIABLp3002
Dimensions
ASIABLB3002
ASIABLD3002
ASIABLB3004/ABLD3004
ASIABLM3024
120
120
54
120
81
Wiring diagrams
ASIABLM3024
ASIABLD300p
ASIABLB300p
Set
Fault
detector
AS-i
GND
AS-i +
GND
AS-i
AS-i +
GND
Filter
AS-i
AS-i +
ON/
OFF
GND
AS-i
AS-i +
AS-i
GND
AS-i +
GND
Filter
AS-i
AS-i +
Filter
24 V
59
Index
ABL1A01
54
ABL1A02
ABL1REM12050
34
44
54
54
ABL1REM24025
54
ABL1REM24042
54
ABL1REM24062
54
ABL1REM24100
54
ABL1RPM12083
54
ABL1RPM24042
54
ABL1RPM24062
54
ABL1RPM24100
54
ABL7RM24025
19
ABL7RP1205
25
ABL7RP4803
25
ABL8BBU24200
34
44
34
44
34
44
44
ABL8BBU24400
ABL8BPK24A03
ABL8BPK24A07
ABL8BPK24A12
ABL8BUF24400
ABL8DCC05060
ABL8DCC12020
ABL8FUS01
ABL8FUS02
ABL8MEM05040
34
44
19
ABL8MEM12020
19
ABL8MEM24003
19
ABL8MEM24006
19
ABL8MEM24012
19
ABL8RED24400
ABL8REM24030
34
48
25
ABL8REM24050
25
ABL8RPM24200
34
ABL8RPS24030
34
ABL8RPS24050
34
ABL8RPS24100
34
ABL8WPS24200
34
ABL8WPS24400
34
ASI20MACC5
34
ASIABLB3002
59
ASIABLB3004
59
ASIABLD3002
59
ASIABLD3004
59
ASIABLM3024
59
LAD90
19
34
38
44
48
34
44
34
44
34
44
SR2CBL01
SR2MEM02
SR2USB01
60
34
44
34
44
34
38
34
38
34
http://www.schneider-electric.com/
Schneider Electric USA, Inc.
8001 Knightdale Blvd.
Knightdale, NC 27545
The information and dimensions in this catalog are provided for the convenience of our customers.
While this information is believed to be accurate, Schneider Electric reserves the right to make
updates and changes without prior notification and assumes no liability for any errors or omissions.
AS-Interface, Modicon, Phaseo, Twido, Zelio, Schneider Electric and logo, and "Make the most
of your energy" are trademarks or registered trademarks of Schneider Electric or its affiliates in
the United States and other countries. Other trademarks used herein are the property of their
respective owners.
Design: Schneider Electric
Photos: Schneider Electric
2011 Schneider Electric. All rights reserved.
DIA3ED207041EN-US
10/2011