License Cerberus Info

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Data Sheet

Cerberus PRO
L1 License Key: for functionality of the Remote Viewer Tool
Model FCA2012-U1
ARCHITECT AND ENGINEER SPECIFICATIONS
Allows remote access between a Cerberus PRO
252-point / 504-point addressable fire alarm
control panel (FACP) and a personal computer (PC) L1 License Key,
252-point FIRE-only FACP ==> Model FC922 Model
504-point FIRE-only FACP ==> Model FC924 FCA2012-U1
252-point Intelligent Voice Communication
(IVC) addressable panel ==> Model FV922
504-point IVC panel ==> Model FV924
Access to the Remote Viewer requires a four-digit
personal identification number (PIN)
Provides means for making simple or highly
integral FACP functions remotely in real time Remote Addressable FACP for
Viewer mid-scale applications
Fits into a diminutive hasp attached to the back
end of a system operating unit
Standard Operating Unit => Model FCM2018-U3 UL 864 9th and ULC-S527 3rd Edition Listed;
Operating Unit with LED => Model FCM2019-U3 FM, CSFM & NYC Fire Department Approved
Product Overview
Model FCA2012-U1 from Siemens Fire System-status conditions, such as: Power, Alarm,
Safety is a L1 license key used as a means for Trouble, Supervisory and Ground-Fault, are vividly
accessing a real-time view of current system status displayed on the end users PC monitor, via simulated,
between a Cerberus PRO 252 / 504-point in-sync graphics from the front-end liquid-crystal
addressable FACP and the laptop of the end-user. display (LCD) screen of the active FACP.
Additionally, the L1 license key makes it possible The remote display of the panels front-end LCD
for the end-user to virtually perform basic or vital screen populates in real time on the laptop PC from
system functions in the same precise manner as if the Cerberus View tab of the custom-configuration
the end-user was essentially present at the in- software tool or from the Cerberus View
event-mode FACP. standalone tool.
A four-digit personal identification number (PIN) is The dimensions for each Model FCA2012-U1 L1
required in order to prevent unauthorized access to license key are as follows:
the control operations of the aforementioned Approximate size: 0.2 (0.51 cm.) [H];
Cerberus PRO FACP, respectively. 0.63 (1.6 cm.) [W]
Model FCA2012-U1 fits into a diminutive metal The weight of each L1 key is about 5 oz. [142 g].
hasp attached to the back end of a Siemens fire-
system operating unit: Temperature and Humidity Range
Standard Operating Unit => Model FCM2018-U3 Model FCA2012-U1 is UL 864 9th Edition Listed for
Operating Unit with LED => Model FCM2019-U3 indoor dry locations within a temperature range of
The L1 license key (Model FCA2012-U1) is FM 120 +/- 3F (49 +/- 2C) to 32 +/- 3F (0 +/- 2C) and a
(#3010); CSFM (#7165-0067:0264) and FDNY relative humidity of 93 +/- 2% at a temperature of
(#6104) Approved. 90 +/- 3F (32+/- 2C).

Cerberus PRO 9820


Fire Safety Products L1 License Key (for use with Remote Viewer)

Answers for infrastructure


Related Documentation Details for Ordering
Data Sheet Part
Product Model Description
Number Number
Cerberus PRO System Operating Units 9801
Cerberus PRO 252-point (FIRE-only) License Key (L1) for remote
Addressable system access, remote view and
9815 FCA2012-U1 remote operation of Cerberus
Cerberus PRO 504-point (FIRE-only) S54400-P102-A1
PRO 252 / 504-point
Addressable system addressable FACPs
Cerberus PRO 252-point IVC panel 9821

Mounting Diagram
Insert License key

This figure illustrates the placement of the license key in the Siemens
Model FCM20-series operating unit

Hasp for the L1 license key, Model FCA2012-U1

L1 license key, Model FCA2012-U1

Installation position: The inscription is at the bottom on the


printed circuit board;
the wider, flat side is at the top on the
clamp.

Raise the clamp of the retainer , and slide the L1 license key,
Model FCA2012-U1 underneath the clamp.

s Cerberus PRO NOTICE The information contained in this data-sheet document is intended only as a summary, and is
subject to change without notice. The devices described here have specific instruction sheets
that cover various technical, limitation and liability information.
Siemens Industry, Inc. Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations
8 Fernwood Road Florham Park, NJ 07932 document, which also contains important information, are provided with the product and, are
available from the Manufacturer.
Tel: (973) 593-2600 Fax: (908) 547-6877
Data contained in these documents should be consulted before specifying or using the product.
Web: www.USA.Siemens.com/Cerberus-PRO For further information or assistance concerning particular problems contact the Manufacturer.

Building Technologies Division March 2016 Supersedes sheet dated 3/2015