Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

Desain ESP

(Electric Submersible Pump)


By :
Adrian Indarti, SST
Perhitungan Perencanaan Desain Pompa
(Studi kasus sumur X )
Data :
Pr = 1175 psi
Pb = 3300 psi
QL = 2721 blpd (75% x QL max)
WC = 98 %
GOR = 792 SCF/STB
SG water = 1.01
SG Oil = 0.84
SG Gas = 0.76
TVD = 8927 ft
PSD = 8230 ft
THP = 135 psi
BHT = 280 :F
Tubing string = 2 7/8 OD, 2.441 ID 6.5 PPF, L-80, EUE
Production Casing = 7 OD, 29 PPF, L-80, R-3 BTC@ 9017
Langkah Langkah Perencanaan :
2. Menentukan Total Dynamic Head (TDH)

1. Menentukan SG rata-rata dan gradient Head Gain =

tekanan fluida 2290
=
0.435
SG rata-rata = (WC x SGw) + {(1 WC) x SGo}
= 5264 ft
= (0.98 x 1.01) + {(1-0.98) x 0.84}
= 1.0066
Tubing friction loss =
1000
Gradien Fluida = 0.433 x SG rata-rata 40 8230
=
1000
= 0.433 x 1.0066
= 329.2 ft
= 0.435 psi/ft 2.31 /
=

135 2.31 /
=
1.0066
= 309.8
Total Dynamic Head
(TDH)

TDH = Head gain (ft) + tubing friction loss (ft) + THP (ft)
= 5264 ft + 329.2 ft + 309.8 ft
= 5903 ft
3. Pemilihan Pompa
Untuk kapasitas fluida 2721 BLPD, casing 7 OD, Total Dynamic Head (TDH) = 5903 ft
dipilih pompa (Lampiran 9 dan 11) TRW Reda Pump type G-62 series 540 / 60 Hz /
3500 rpm dengan recommended capacity range 2000 3100 BPD.
Dari Pump Performance Curve untuk G-62, 60 Hz (Lampiran 11) didapat :
3800
Head / stage = = 38 ft/stage
100 sta
125
Horse Power Motor Load/stage = = 1.25 HP/stage
100
Pump Efficiency = 62 %
() 5903
Jumlah total stages = = = 155 stages
/ 38
4. Gas Separator
Dari (Lampiran 15) , dengan pertimbangan laju alir 2721 BPD, dan ID casing 6.184 maka
gas separator yang dipilih adalah Dynamic Rotary Gas Separator / GN 20-40/5.13 OD
dengan efisiensi pemisahan (separation efficiency) gas 80-95 % dan Gas Ingestion
Percentage (GIP) 5-20%.

5. Seal Protector/Seal Selection


Dari (Lampiran 14), protector yang dipilih adalah modular protector LSLSL (BHT > 250 :F).
6. Pemilihan Motor
Perhitungan HP motor
HP/stage = 1.25
Total HP = HP/stage x jumlah stage x SG fluid
= 1.25 x 155 x 1.0066
= 195 HP
Hal-hal yang menjadi pertimbangan dalam pemilihan motor
adalah kebutuhan HP (horse power) pompa (HP = 195 ) untuk
mengangkat rate produksi yang diharapkan dan ukuran ID
production casing (ID 6.184 ). Dalam kasus ini , berdasar pada
tabel pemilihan motor (lampiran 10) dipilih motor 540 series/
200 HP/ 1160 volts/ 105 amps
7. Pemilihan Kabel
a. Diameter round cable #2 AWG series 1.5 KV standard armored 1.26 inch
Clearance = (ID casing OD coupling tubing diameter round cable)/2
= (6.184 3.46 1.26)/2
= 0.732 inch
Karena clearance > 0.25 inch maka round cable tipe tersebut memenuhi
syarat.
b. Diameter flat standard 1.5 KV reda armored cable 0.420 x 1.060 inch
Clearance = (ID casing OD pompa diameter flat cable)/2
= (6.184 5.13 0.42)/2
= 0.317 inch
Karena clearance > 0.126 inch, maka flat cable tipe tersebut memenuhi
syarat.
8. Memilih switchboard
Voltage drop = 35 volts/ 1000 ft (Lampiran 12)
:200
Cable voltage drop =
1000
8230:200 35 1.0
=
1000
= 295.05 volt
K = faktor koreksi temperatur (BHT)
SVR = Surface Voltage Required ( voltage travo yang dibutuhkan)
SVR = motor name plate voltage + cable voltage drop
= 1160 + 295.05
= 1455.05 Volt
Dengan kebutuhan SVR 1455.05 volts, arus 105 ampere, dan 200 HP maka dari (Lampiran 13)
switchboard yang sesuai adalah kelas 150 MDFH, jenis 76 A, ukuran 4, tegangan maksimum
1500 volts, beban arus maksimum 150 ampere dan horse power sebesar 250 HP.
9. Memimilh Transformer / Trafo
Rating travo dinyatakan dalam KVA ( Kilo Volt Amps)
1.73
= + 2.5%
1000
1455.05 105 (1.73)
= + 2.5%
1000
KVA = 270. 92 KVA

Dengan KVA = 270.92 KVA, dapat diplih trafo dengan rating 279 KVA (sesuai
yang ada di pasaran).
Hasil Perencanaan Pompa ESP adalah sebagai berikut :

ESP type : TRW REDA G-62/155 stages/ 60 Hz dengan recommended capacity range 2000-3100 BPD.

Motor : 540 series motors/ 200 HP/ 1160 volts/ 105 amps

Protector : 400 series modular protector LSLSL

Gas Separator : 400 series VGSA GN 20 40

Cable : round cable #2 AWG series 1.5 KV standard armored dan flat standard 1.5 KV Reda Armored

Switchboard type : 150 MDFH, jenis 76 A, ukuran 4, tegangan maksimum 1500 volts, 150 ampere dan 250 HP.

Trafo : Trafo dengan rating 279 KVA


Lampiran 8
Grafik Friction Loss
Lampiran 9
Tabel Pemilihan Ukuran Pompa (60 Hz / 3500 rpm)
Lampiran 10
Tabel Pemilihan Motor
Lampiran 11
Pump Performance Curve TRW REDA G-62
Lampiran 12
Grafik Voltage Drop
Lampiran 13
Tabel Pemilihan Switch Board
Lampiran 14
Tabel Pemilihan Protector
Lampiran 15
Tabel Pemilihan Gas Separator
Lampiran 16
Tabel Pemilihan Kabel
Lampiran 17
Grafik Pressure Traverse
2.991 ID
Lampiran 18
Grafik after Standing and Katz
untuk menentukan harga factor Z