Seko Tekna EVO Training Presentation PDF
Seko Tekna EVO Training Presentation PDF
800
803
16 LMI 1.6 76 11 4
800
14 Prominent 0.8 75 11 3
12 Pulsafeeder 4.7 38 19 4
603
10 Alldos 0.3 18 10 1
8 Grundfos 1.8 48 5 2
pressure [bar]
6 Seko 2 70 7 2
4 803 Aqua 2 50 9 1
2 Etatron 1 60 14 4
0 Emec 0.5 60 14 3
0 10 20 30 40 50 60
=
2x 603 6 lt /h @ 8 bar
lt/h 36 W
6 Your dosing partner
Innovative Features
603
100 W + 100 W
= +
for 1 year
house hold use
TEKNA 602
Body Seat
Type Connections Balls Diaphragm
pump valve
FPM
H PVDF PVDF Ceramic Or PTFE
EPDM
Available Range
Pressure Flow Rate
Model cc/stroke
[bar] [lt/h]
20 2.5 0.35
600 18 3.0 0.42
12 4 0.42
10 5 0.52
603 8 6 0.63
2 8 0.83
12 7 0.36
10 10 0.52
800 5 15 0.78
1 18 0.94
5 20 1.11
4 25 1.39
803 2 40 2.22
1 54 3.00
IP 65 Plastic Enclosure
Easy Installation
Easy Installation
Easy Installation
Installations possibilities:
Installation on a tank Under chemical Water meter
Wall mounting
with bracket liquid level mounting
Hydraulic Characteristics
Complete Pump Head
Complete Solenoid
Complete Valve
Mounting bracket
Pulse divide ( /5 ).
ATL
Proportional dosing to a digital (flowmeter) or analog (4-20 mA) signal.
Adjustable knob (% freq. and n in multiply).
Selectors at 6 positions: 3 in divide mode (n=1, 4, 10), 1 in multiply mode (n=1), 1 in
proportional mode to a 4-20 mA signal, 1 in costant mode.
APG
22 Your dosing partner
AKL (AKS) functions
Press the SEL button until the corresponding Maximum Speed LED comes on.
The flow rate can be regulated by acting on the speed regulation knob on the front of th e pump.
Time On Mode
Press the SEL button until the corresponding LED comes on.
When switched on, the pump doses for the time set on the corresponding potentiometer (blue scale), at the
frequency set with the flow rate regulation potentiometer.
By positioning dip-switch No. 4 in the ON position, the pump waits for the period of time set by the Time-Off
potentiometer (red scale) before dosing. It is also possible to control this dosage with a remote control, or with an
water-meter pulse-sender: at every signal, the pump will make a dosage based on the set time and speed and, if
necessary, with an activation delay, if dip-switch No. 4 is set.
Press the SEL button until the corresponding LED comes on.
When switched on, the pump doses at the speed set on the flow rate regulation potentiometer, repeating on/off
cycles as set in the relative Time On and Time Off potenti ometers. By positioning the dip-switch No. 4 i n ON position,
the pump inverts the two times, meaning that the Time Off (pause) starts upon activation and it then passes to the
Time On (dosage time).
Press the SEL button until the corresponding LED comes on.
The pum p doses manually at the percentage selected with the potentiometer.
Liquid end
Connection box
Mounting bracket
TCK
27 Your dosing partner
TPG functions PROG
Configuration
enter
Statistics Alarms
Hours = ####.## Level Stop
Password Alarms
**** Flow Off
Configuration
Pump Funtions enter
Alarm Relay
Open
Manual <-
Pump Functions
Divide (n:1)
Configuration
Pump Funtions enter
Alarm Relay
Open
Manual <-
Statistics Alarms
Hours = ####.## Level Stop
Password Alarms
**** Flow Off
Configuration
Pump Funtions enter
Alarm Relay
Open
Manual <-
TEKNA vs comparison
Flow Rate Functions
OLD TEKNA OLD TEKNA
TEKNA EVO Pressure Flow Rate
TEKNA EVO
Model Model bar L/h
20 2,5 ACS
600 600 AKS
18 3 AXS
12 4 ACL
AKL
601 10 5 AXL
603
602 8 6
DCL Not Available
2 8
12 7
DPZ TPG or APG
901 10 10
800
902 5 15
DPG TPG
1 18
5 20
DPR TPR
903 4 25
803
904 2 40
DCK TCK
1 54