Professional Documents
Culture Documents
Connector Panels and External Cables in
Connector Panels and External Cables in
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2010. All rights reserved
2 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
Table of Contents
This document has 111 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces
(CPRJ45-A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1 LAN interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1.1 1 Gbit/s optical uplink LAN cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
6.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables . . . . . . . . . . . . . . . . 92
6.2 External alarm cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
6.3 VDU/LPT peripheral cabling (LPT/VDU interfaces) . . . . . . . . . . . . . . . 101
6.4 External synchronisation cabling (EXT SYNC interfaces) . . . . . . . . . . 103
DN70617303 Id:0900d805804bce7d 3
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
4 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
List of Figures
Figure 1 Connector panel CPETS-G and CPSM cable (front view). . . . . . . . . . . 15
Figure 2 Connector panel CPETS-H (front view) . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 3 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 17
Figure 4 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 19
Figure 5 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 35
Figure 6 Connector panel CPETS-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 7 Connector panel CPETS-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 43
Figure 9 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 43
Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 45
Figure 11 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 46
Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 61
Figure 13 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 61
Figure 14 CPETC-E panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 15 CPETC-F panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 16 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 68
Figure 17 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 70
Figure 18 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 85
Figure 19 D-connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation interfac-
es - seen from the front of the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 21 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the
buzzer jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Figure 23 Peripheral cables; CNM for VDU and CNP for LPT. . . . . . . . . . . . . . . 102
Figure 24 CPGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Figure 25 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DN70617303 Id:0900d805804bce7d 5
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
List of Tables
Table 1 BSC network elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2 TCSM3i product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 3 Connector panels and the CPGO used in the Flexi BSC . . . . . . . . . . . . 12
Table 4 E1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . . . . . . . 17
Table 5 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 17
Table 6 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 18
Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 18
Table 8 Balanced connector panels for the BSC3i . . . . . . . . . . . . . . . . . . . . . . . 19
Table 9 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 19
Table 10 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 11 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 35
Table 13 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 35
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface . .
36
Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface
38
Table 16 E1 and T1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . 42
Table 17 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 42
Table 18 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 43
Table 19 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 44
Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 44
Table 21 Balanced connector panels in the cabling cabinet . . . . . . . . . . . . . . . . . 45
Table 22 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 45
Table 23 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 46
Table 24 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 25 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 26 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 60
Table 27 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 60
Table 28 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 61
Table 29 Balanced panels in the cabling cabinet - A-interface . . . . . . . . . . . . . . . 62
Table 30 Balanced panels in the cabling cabinet - Ater-interface . . . . . . . . . . . . . 65
Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries . . . . . . . . 68
Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries . . . . 69
Table 33 Unbalanced connector panels for the Flexi BSC . . . . . . . . . . . . . . . . . . 69
Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 70
Table 35 Unbalanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 36 Unbalanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . 76
Table 37 Unbalanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . 85
Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 85
Table 39 Unbalanced panels in cabling cabinet - A-interface . . . . . . . . . . . . . . . . 87
Table 40 Unbalanced panels in cabling cabinet - Ater-interface . . . . . . . . . . . . . . 90
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected
cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
6 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected
cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 45 Recommended cable types for LAN cables (CNI and CNIX) . . . . . . . . 94
Table 46 External alarm cabling connectors in the CPRJ45-A panel . . . . . . . . . 95
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,
AEIx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 49 Signals on panel connector 23 (current-controlled ALS inputs) . . . . . . 98
Table 50 General requirements for external alarm cable CNDE . . . . . . . . . . . . . 99
Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration 101
Table 52 Recommended cable types for V.24/V.11 cables (CNI) . . . . . . . . . . . 102
Table 53 The pin configuration for connectors 18 and 19 . . . . . . . . . . . . . . . . . 103
Table 54 Recommended cable types for synchronisation cables (CNI) . . . . . . 103
Table 55 Pin configuration for connectors 20 and 28 . . . . . . . . . . . . . . . . . . . . 104
Table 56 Main characteristics of optical singlemode cables and connectors . . 105
Table 57 Main characteristics of optical multimode cables and connectors . . . 105
DN70617303 Id:0900d805804bce7d 7
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i
8 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Summary of changes
and TCSM3i
Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Issue 1-0
The first issue of Connector Panels and External Cables in Flexi BSC and TCSM3i,
based on Connector Panels and External Cables in BSC3i and TCSM3i. It is included in
Flexi BSC first delivery and upgrade delivery documentation and in TCSM3i delivery
documentation.
DN70617303 Id:0900d805804dcc03 9
Issue 1-0
Overview Connector Panels and External Cables in Flexi BSC
and TCSM3i
1 Overview
This is a description of the connector panels and the related external cables used in the
first-delivery Flexi BSC and in the upgrade-delivery Flexi BSC and in the TCSM3i.
The cabling connecting the equipment to the environment is treated from the point of
view of the Flexi BSC and TCSM3i, indicating how and where the external wiring is con-
nected to.
BSC = Base Station Controller, a general term for all BSC network elements
General name Product name Explanation
BSCi/BSC2i BSCi High capacity (upgraded) version of the
first generation DX 200 BSC (BSCE)
BSC2i High capacity version of the second gener-
ation DX 200 BSC2
Flexi BSC product BSC3i 660 660 TRX one cabinet configuration,
family upgradable to Flexi BSC
BSC3i 1000/2000 1000 TRX one-cabinet or 2000 TRX two-
cabinet configuration, upgradable to Flexi
BSC
Flexi BSC 3000 TRX one-cabinet configuration (S14)
10 Id:0900d805804d3524 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Overview
and TCSM3i
1.4 Feedback
We are always interested to know whether our manuals provide the information you
need. If you have any comments about this document or any other manual, please pass
them on to your local sales representative.
DN70617303 Id:0900d805804d3524 11
Issue 1-0
Connector panel types in the Flexi BSC Connector Panels and External Cables in Flexi BSC
and TCSM3i
Table 3 Connector panels and the CPGO used in the Flexi BSC
12 Id:0900d805804d0c7c DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Connector panel types in the Flexi BSC
and TCSM3i
Table 3 Connector panels and the CPGO used in the Flexi BSC (Cont.)
The external cables are connected to the connector panels; therefore, extra grounding
devices are not needed.
DN70617303 Id:0900d805804d0c7c 13
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
14 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ET16 CPETS-G
00 02 04 06
01 03 05 07
08 10 12 14
09 11 13 15
16 18 20 22
17 19 21 23
24 26 28 30
25 27 29 31
32 34 36 38
33 35 37 39
40 42 44 46
41 43 45 47
Front view
01 00
0
1 03 02
2
3
05 04
4
5
6 07 06
7 LINE
8 ALARMS 09 08
9
10
11 10
11
12
13 Rear view
14
15
CPSM
DN70457779
DN70617303 Id:0900d805804d10f1 15
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
00 02 04 06 CPETS-H
01 03 05 07
08 10 12 14
09 11 13 15
16 18 20 22
17 19 21 23
24 26 28 30
25 27 29 31
32 34 36 38
33 35 37 39
40 42 44 46
41 43 45 47
48 50 52 54
49 51 53 55
56 58 60 62
57 59 61 63
64 66 68 70
65 67 69 71
72 74 76 78
73 75 77 79
80 82 84 86
81 83 85 87
88 90 92 94
89 91 93 95
96 98 100 102
97 99 101 103
104 106 108 110
105 107 109 111
112 114 116 118
113 115 117 119
120 122 124 126
121 123 125 127
128 130 132 134
129 131 133 135
136 138 140 142
137 139 141 143
144 146 148 150
145 147 149 151
152 154 156 158
153 155 157 159
160 162 164 166
161 163 165 167
168 170 172 174
169 171 173 175
176 178 180 182
177 179 181 183
184 186 188 190
185 187 189 191
192 194 196 198
193 195 197 199
200 202 204 206
201 203 205 207
208 210 212 214
209 211 213 215
216 218 220 222
217 219 221 223
224 226 228 230
225 227 229 231
232 234 236 238
233 235 237 239
240 242 244 246
241 243 245 247
248 250 252 254
249 251 253 255
DN70458754
16 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
The E1 trunk cable connector and configuration is presented in the following table.
Recommended cable type for E1 trunk cables (CNIB) for the CPETS-G and CPETS-H
is presented in the following table and figure.
DN00206525
CONNECTOR 1 2 3 4
Figure 3 RJ45 connector cable (CNIB cable type) with four connectors
The external trunk cable (from the ET panel) and the connector should meet the require-
ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The
connector should also meet the requirements of the FCC Part 68.
The following table shows the equipping order of the CPETS-G panel at the cabinet top
in first deliveries.
DN70617303 Id:0900d805804d10f1 17
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ETC car- From SGC1C- To CPETS-G Front ports in Corresponding external ET numbers
tridge A connector connector CPETS-G panel
position position thorough this
cable
ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271
ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287
The following table shows the equipping order of the CPETS-G panel at the cabinet top
in upgrade deliveries.
ETC car- From GT6C-A To CPETS-G Front ports in Corresponding external ET numbers
tridge connector connector CPETS-G panel
position position through this cable
ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559
18 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table
and figure.
DN00206525
CONNECTOR 1 2 3 4
Figure 4 RJ45 connector cable (CNIB cable type) with four connectors
Equipping order
The equipping order of the connector panels in the cabling cabinet in first deliveries is
presented in the following table.
DN70617303 Id:0900d805804d10f1 19
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
20 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ET1392,ET1393,ET1394,ET139
GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227 5
ET1396,ET1397,ET1398,ET139
GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231 9
ET1400,ET1401,ET1402,ET140
GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235 3
ET1404,ET1405,ET1406,ET140
GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239 7
ET1280,ET1281,ET1282,ET128
GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243 3
ET1284,ET1285,ET1286,ET128
GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247 7
DN70617303 Id:0900d805804d10f1 21
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ET1920,ET1921,ET1922,ET192
GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03 3
ET1924,ET1925,ET1926,ET192
GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07 7
ET1928,ET1929,ET1930,ET193
GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11 1
ET1932,ET1933,ET1934,ET193
GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15 5
ET1936,ET1937,ET1938,ET193
GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19 9
ET1940,ET1941,ET1942,ET194
GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23 3
ET1944,ET1945,ET1946,ET194
GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27 7
ET1948,ET1949,ET1950,ET195
GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31 1
ET1952,ET1953,ET1954,ET195
GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35 5
ET1956,ET1957,ET1958,ET195
GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39 9
ET1960,ET1961,ET1962,ET196
GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43 3
ET1964,ET1965,ET1966,ET196
GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47 7
ET1968,ET1969,ET1970,ET197
GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03 1
ET1972,ET1973,ET1974,ET197
GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07 5
ET1976,ET1977,ET1978,ET197
GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11 9
ET1980,ET1981,ET1982,ET198
GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15 3
ET1984,ET1985,ET1986,ET198
GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19 7
ET1988,ET1989,ET1990,ET199
GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23 1
22 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ET2016,ET2017,ET2018,ET201
GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03 9
ET2020,ET2021,ET2022,ET202
GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07 3
ET2024,ET2025,ET2026,ET202
GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11 7
ET2028,ET2029,ET2030,ET203
GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15 1
ET2032,ET2033,ET2034,ET203
GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19 5
ET2036,ET2037,ET2038,ET203
GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23 9
ET2040,ET2041,ET2042,ET204
GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27 3
ET2044,ET2045,ET2046,ET204
GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31 7
ET1136,ET1137,ET1138,ET113
ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35 9
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39 3
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43 3
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47 3
ET1024,ET1025,ET1026,ET102
ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03 7
DN70617303 Id:0900d805804d10f1 23
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
24 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
DN70617303 Id:0900d805804d10f1 25
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ET1296,ET1297,ET1298,ET129
GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03 9
ET1300,ET1301,ET1302,ET130
GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07 3
ET1304,ET1305,ET1306,ET130
GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11 7
ET1308,ET1309,ET1310,ET131
GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15 1
ET1312,ET1313,ET1314,ET131
GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19 5
ET1316,ET1317,ET1318,ET131
GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23 9
ET1320,ET1321,ET1322,ET132
GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27 3
ET1324,ET1325,ET1326,ET132
GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31 7
ET1328,ET1329,ET1330,ET133
GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35 1
ET1332,ET1333,ET1334,ET133
GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39 5
ET1336,ET1337,ET1338,ET133
GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43 9
ET1340,ET1341,ET1342,ET134
GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47 3
The equipping order of the connector panels in the cabling cabinet in upgrade deliveries
is presented in the following table.
26 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
DN70617303 Id:0900d805804d10f1 27
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
28 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ET1456,ET1457,ET1458,ET1
GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39 459
ET1460,ET1461,ET1462,ET1
GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43 463
ET1464,ET1465,ET1466,ET1
GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47 467
ET1468,ET1469,ET1470,ET1
GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27 471
ET1472,ET1473,ET1474,ET1
GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31 475
DN70617303 Id:0900d805804d10f1 29
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ET1504,ET1505,ET1506,ET1
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39 507
ET1508,ET1509,ET1510,ET1
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43 511
ET1512,ET1513,ET1514,ET1
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47 515
ET1516,ET1517,ET1518,ET1
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27 519
ET1520,ET1521,ET1522,ET1
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31 523
ET1524,ET1525,ET1526,ET1
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35 527
ET1528,ET1529,ET1530,ET1
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15 531
ET1532,ET1533,ET1534,ET1
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19 535
ET1344,ET1345,ET1346,ET1
ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23 347
ET1348,ET1349,ET1350,ET1
ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03 351
ET1352,ET1353,ET1354,ET1
ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07 355
ET1356,ET1357,ET1358,ET1
ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11 359
ET1360,ET1361,ET1362,ET1
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39 363
30 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ET1600,ET1601,ET1602,ET1
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247 603
ET1604,ET1605,ET1606,ET1
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251 607
ET1608,ET1609,ET1610,ET1
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255 611
ET1612,ET1613,ET1614,ET1
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235 615
ET1616,ET1617,ET1618,ET1
ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239 619
ET1620,ET1621,ET1622,ET1
ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243 623
ET1624,ET1625,ET1626,ET1
ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223 627
ET1628,ET1629,ET1630,ET1
ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227 631
ET1632,ET1633,ET1634,ET1
ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231 635
DN70617303 Id:0900d805804d10f1 31
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
32 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
DN70617303 Id:0900d805804d10f1 33
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
3.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.
34 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
The cables and connectors should meet the requirements of the UL 1459 standard or
the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table
and figure.
DN00206525
CONNECTOR 1 2 3 4
Figure 5 RJ45 connector cable (CNIB cable type) with four connectors
Equipping order
Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-
sented in the following table.
DN70617303 Id:0900d805804d10f1 35
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02
36 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 202, 203 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 210, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228, 229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16
ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)
DN70617303 Id:0900d805804d10f1 37
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)
From car- TR3 unit slot From ET16 slot and ET panel / front ports
tridge connector position through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131
38 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)
From car- TR3 unit slot From ET16 slot and ET panel / front ports
tridge connector position through this cable
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C car-
tridge is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used
for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC
and the other half for the other BSC).
DN70617303 Id:0900d805804d10f1 39
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
CPETS-E
00 01 02 03 04 05 06 07 08 09 10 11
12 13 14 15 16 17 18 19 20 21 22 23
24 24 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47
DN0626746
Figure 6 Connector panel CPETS-E
Cabling of the CPETS-F panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETS-F is installed in the optional cabling cabinet.
For details of the panel, see figure Connector panel CPETS-F.
40 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
00 01 02 03 04 05 06 07 08 09 10 11
CPETS-F
12 13 14 15 16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47
48 49 50 51 52 53 54 55 56 57 58 59
60 61 62 63 64 65 66 67
68 69 70 71 72 73 74 75 76 77 78 79
80 81 82 83 84 85 86 87 88 89 90 91
104 105 106 107 108 109 110 111 112 113 114 115
116 117 118 119 120 121 122 123 124 125 126 127
128 129 130 131 132 133 134 135 136 137 138 139
140 141 142 143 144 145 146 147 148 149 150 151
152 153 154 155 156 157 158 159 160 161 162 163
164 165 166 167 168 169 170 171 172 173 174 175
176 177 178 179 180 181 182 183 184 185 186 187
196 197 198 199 200 201 202 203 204 205 206 207
208 209 210 211 212 213 214 215 216 217 218 219
220 221 222 223 224 225 226 227 228 229 230 231
232 233 234 235 236 237 238 239 240 241 242 243
244 245 246 247 248 249 250 251 252 253 254 255
DN0626407
DN70617303 Id:0900d805804ebded 41
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
The external trunk cable (from the ET panel) and the connector should meet the require-
ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The
connector should also meet the requirements of the FCC Part 68
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
and figure.
42 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
IDENTIFICATION
STICKER
CABLE
SLEEVE
MODULAR CONNECTOR
8 1 DN9833994
Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.
DN00206525
CONNECTOR 1 2 3 4
Figure 9 RJ45 connector cable (CNIA cable type) with four connectors
The equipping order of the CPETS-E panel at the cabinet in the first deliveries top is pre-
sented in the following table.
DN70617303 Id:0900d805804ebded 43
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
The equipping order of the CPETS-E panel at the cabinet in the upgrade deliveries top
is presented in the following table.
44 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
and figure.
IDENTIFICATION
STICKER
CABLE
SLEEVE
MODULAR CONNECTOR
8 1 DN9833994
Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.
DN70617303 Id:0900d805804ebded 45
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
DN00206525
CONNECTOR 1 2 3 4
Figure 11 RJ45 connector cable (CNIA cable type) with four connectors
Equipping order
The equipping order in the cabling cabinet in the first deliveries presented in the follow-
ing table.
46 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
DN70617303 Id:0900d805804ebded 47
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
48 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
DN70617303 Id:0900d805804ebded 49
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
50 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
DN70617303 Id:0900d805804ebded 51
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
The equipping order of the connector panels in the cabling cabinet in upgrade deliveries
is presented in the following table.
52 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
DN70617303 Id:0900d805804ebded 53
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
54 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
ET1504,ET1505,ET1506,ET15
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39 07
ET1508,ET1509,ET1510,ET15
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43 11
ET1512,ET1513,ET1514,ET15
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47 15
ET1516,ET1517,ET1518,ET15
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27 19
ET1520,ET1521,ET1522,ET15
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31 23
ET1524,ET1525,ET1526,ET15
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35 27
ET1528,ET1529,ET1530,ET15
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15 31
ET1532,ET1533,ET1534,ET15
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19 35
DN70617303 Id:0900d805804ebded 55
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
ET1360,ET1361,ET1362,ET13
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39 63
ET1364,ET1365,ET1366,ET13
ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43 67
ET1368,ET1369,ET1370,ET13
ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47 71
ET1372,ET1373,ET1374,ET13
ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27 75
ET1376,ET1377,ET1378,ET13
ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31 79
ET1380,ET1381,ET1382,ET13
ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35 83
ET1384,ET1385,ET1386,ET13
ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15 87
ET1388,ET1389,ET1390,ET13
ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19 91
ET1392,ET1393,ET1394,ET13
ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23 95
ET1396,ET1397,ET1398,ET13
ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03 99
ET1400,ET1401,ET1402,ET14
ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07 03
ET1404,ET1405,ET1406,ET14
ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11 07
ET1600,ET1601,ET1602,ET16
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247 03
ET1604,ET1605,ET1606,ET16
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251 07
ET1608,ET1609,ET1610,ET16
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255 11
ET1612,ET1613,ET1614,ET16
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235 15
56 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
DN70617303 Id:0900d805804ebded 57
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
58 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
4.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
DN70617303 Id:0900d805804ebded 59
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.
The cables and connectors should meet the requirements of the UL 1459 standard or
the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
figure.
60 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
IDENTIFICATION
STICKER
CABLE
SLEEVE
MODULAR CONNECTOR
8 1 DN9833994
Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.
DN00206525
CONNECTOR 1 2 3 4
Figure 13 RJ45 connector cable (CNIA cable type) with four connectors
Equipping order
The cabling cabinet is always used with the TCSM3i for stand-alone installation option.
The cabling cabinet and the balanced ET panels are delivered in an optional cabling
cabinet set, because TCSA cabinet is a base for both TCSM3i for stand-alone installa-
tion option and for TCSM3i for combined BSC/TCSM installation option.
DN70617303 Id:0900d805804ebded 61
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-
sented in the following table.
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16
62 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 120, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228,229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16
ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01
DN70617303 Id:0900d805804ebded 63
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i
ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122,123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16
64 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)
From car- TR3 unit slot From ET16 slot and ET panel / front ports through
tridge connector position this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge
is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for
transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the
other half for the other BSC).
DN70617303 Id:0900d805804ebded 65
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
00 01
02 03
04 05
06 07
08 09
10 11
DN05160363 CPETC-E
00 01 02 03
8 7 6 5 4 3 2 1
Tx Rx Tx Rx Tx Rx Tx Rx
Figure 14 CPETC-E panel
Cabling of the CPETC-F panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETC-F is installed in the optional cabling cabinet (two panels).
For more information on the panel, see the following figure.
66 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
CPETC-F
00 01 02 03 04 05 06 07
08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31
32 33 34 35 36 37 38 39
40 41 42 43 44 45 46 47
48 49 50 51 52 53 54 55
56 57 58 59 60 61 62 63
DN0626419
DN70617303 Id:0900d8058049ecb0 67
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
DN99257685
A1 A8
Figure 16 CPRD cable assembly (panel end connector mounted)
The equipping order of the CPETC-E panel in first deliveries is presented in the following
table.
68 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries (Cont.)
The equipping order of the CPETC-E panel in upgrade deliveries is presented in the fol-
lowing table.
DN70617303 Id:0900d8058049ecb0 69
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial
cable connectors from the CPETC-E or CPETC-F panels. The recommended cable type
for E1 coaxial trunk cables is CPRD. See the following table and figure.
DN99257685
A1 A8
Figure 17 CPRD cable assembly (panel end connector mounted)
Equipping order
The equipping order in the cabling cabinet in first deliveries is presented in the following
table.
70 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
DN70617303 Id:0900d8058049ecb0 71
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
72 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
DN70617303 Id:0900d8058049ecb0 73
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
74 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
DN70617303 Id:0900d8058049ecb0 75
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
The equipping order in the cabling cabinet in upgrade deliveries is presented in the fol-
lowing table.
76 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
DN70617303 Id:0900d8058049ecb0 77
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
78 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
ET1456,ET1457,ET1458,ET145
GTIC 1 B 04.1A Panel 03 / B 10 10 (4*ET) 9
ET1460,ET1461,ET1462,ET146
GTIC 1 B 04.1J Panel 03 / B 11 11 (4*ET) 3
ET1464,ET1465,ET1466,ET146
GTIC 1 B 04.1R Panel 03 / B 08 08 (4*ET) 7
ET1468,ET1469,ET1470,ET147
GTIC 1 B 04.1Z Panel 03 / B 09 09 (4*ET) 1
ET1472,ET1473,ET1474,ET147
GTIC 1 B 05.1A Panel 03 / B 06 06 (4*ET) 5
ET1476,ET1477,ET1478,ET147
GTIC 1 B 05.1J Panel 03 / B 07 07 (4*ET) 9
ET1480,ET1481,ET1482,ET148
GTIC 1 B 05.1R Panel 03 / B 04 04 (4*ET) 3
ET1484,ET1485,ET1486,ET148
GTIC 1 B 05.1Z Panel 03 / B 05 05 (4*ET) 7
ET1488,ET1489,ET1490,ET149
GTIC 1 B 06.1A Panel 03 / B 02 02 (4*ET) 1
ET1492,ET1493,ET1494,ET149
GTIC 1 B 06.1J Panel 03 / B 03 03 (4*ET) 5
DN70617303 Id:0900d8058049ecb0 79
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
ET1504,ET1505,ET1506,ET150
GTIC 1 B 07.1A Panel 02 / B 10 10 (4*ET) 7
ET1508,ET1509,ET1510,ET151
GTIC 1 B 07.1J Panel 02 / B 11 11 (4*ET) 1
ET1512,ET1513,ET1514,ET151
GTIC 1 B 07.1R Panel 02 / B 08 08 (4*ET) 5
ET1516,ET1517,ET1518,ET151
GTIC 1 B 07.1Z Panel 02 / B 09 09 (4*ET) 9
ET1520,ET1521,ET1522,ET152
GTIC 1 B 08.1A Panel 02 / B 06 06 (4*ET) 3
ET1524,ET1525,ET1526,ET152
GTIC 1 B 08.1J Panel 02 / B 07 07 (4*ET) 7
ET1528,ET1529,ET1530,ET153
GTIC 1 B 08.1R Panel 02 / B 04 04 (4*ET) 1
ET1532,ET1533,ET1534,ET153
GTIC 1 B 08.1Z Panel 02 / B 05 05 (4*ET) 5
ET1344,ET1345,ET1346,ET134
ETC 2 B 01.1A Panel 02 / B 02 02 (4*ET) 7
ET1348,ET1349,ET1350,ET135
ETC 2 B 01.1J Panel 02 / B 03 03 (4*ET) 1
ET1352,ET1353,ET1354,ET135
ETC 2 B 01.1R Panel 02 / B 00 00 (4*ET) 5
ET1356,ET1357,ET1358,ET135
ETC 2 B 01.1Z Panel 02 / B 01 01 (4*ET) 9
ET1360,ET1361,ET1362,ET136
ETC 2 B 02.1A Panel 01 / B 10 10 (4*ET) 3
ET1364,ET1365,ET1366,ET136
ETC 2 B 02.1J Panel 01 / B 11 11 (4*ET) 7
ET1368,ET1369,ET1370,ET137
ETC 2 B 02.1R Panel 01 / B 08 08 (4*ET) 1
ET1372,ET1373,ET1374,ET137
ETC 2 B 02.1Z Panel 01 / B 09 09 (4*ET) 5
ET1376,ET1377,ET1378,ET137
ETC 2 B 03.1A Panel 01 / B 06 06 (4*ET) 9
80 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
ET1600,ET1601,ET1602,ET160
ETC 2 B 05.1A Panel 00 / B 56 56 (4*ET) 3
ET1604,ET1605,ET1606,ET160
ETC 2 B 05.1J Panel 00 / B 57 57 (4*ET) 7
ET1608,ET1609,ET1610,ET161
ETC 2 B 05.1R Panel 00 / B 58 58 (4*ET) 1
ET1612,ET1613,ET1614,ET161
ETC 2 B 05.1Z Panel 00 / B 59 59 (4*ET) 5
ET1616,ET1617,ET1618,ET161
ETC 2 B 06.1A Panel 00 / B 60 60 (4*ET) 9
ET1620,ET1621,ET1622,ET162
ETC 2 B 06.1J Panel 00 / B 61 61 (4*ET) 3
ET1624,ET1625,ET1626,ET162
ETC 2 B 06.1R Panel 00 / B 62 62 (4*ET) 7
ET1628,ET1629,ET1630,ET163
ETC 2 B 06.1Z Panel 00 / B 63 63 (4*ET) 1
ET1632,ET1633,ET1634,ET163
ETC 2 B 07.1A Panel 00 / B 48 48 (4*ET) 5
ET1636,ET1637,ET1638,ET163
ETC 2 B 07.1J Panel 00 / B 49 49 (4*ET) 9
ET1640,ET1641,ET1642,ET164
ETC 2 B 07.1R Panel 00 / B 50 50 (4*ET) 3
ET1644,ET1645,ET1646,ET164
ETC 2 B 07.1Z Panel 00 / B 51 51 (4*ET) 7
ET1648,ET1649,ET1650,ET165
ETC 2 B 08.1A Panel 00 / B 52 52 (4*ET) 1
DN70617303 Id:0900d8058049ecb0 81
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
82 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
DN70617303 Id:0900d8058049ecb0 83
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
5.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.
84 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
Recommended cable type for E1 coaxial trunk cables is CPRD. See the following table
and figure.
DN99257685
A1 A8
Figure 18 CPRD cable assembly (panel end connector mounted)
Equipping order
The cabling cabinet is used with the TCSM3i for stand-alone installation option.
The D-connector in the unbalanced panels is shown in the following figure and the
equipping order in the cabling cabinet is presented in the following table.
DN70617303 Id:0900d8058049ecb0 85
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
86 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
Figure 19 D-connector
ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable
ETC 0 B 01.1A Panel 0 / B 00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 13 (4*ET) A-interf. PCM1-4/ TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 15
DN70617303 Id:0900d8058049ecb0 87
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable
ETC 1 B 04.1Z Panel 0 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 32 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 33 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 34 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 35 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 36 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 37 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 38 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 39 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 40 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 41 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 42 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 43 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 44 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 45 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 46 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 47 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 48 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 49 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 50 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 51 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 52 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 53 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 54 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 55 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 56 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 57 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 58 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 59 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 60 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 61 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 62 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 63 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 16
88 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)
ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable
ETC 0 B 05.1A Panel 4 / B00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 13 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 16
DN70617303 Id:0900d8058049ecb0 89
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i
From car- TR3 unit slot From ET16 slot and con- ET panel / front ports
tridge nector position through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 32 (4*ET)
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 33 (4*ET)
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 34 (4*ET)
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 35 (4*ET)
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 36 (4*ET)
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 37 (4*ET)
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 38 (4*ET)
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 39 (4*ET)
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 40 (4*ET)
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 41 (4*ET)
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 42 (4*ET)
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 43 (4*ET)
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 44 (4*ET)
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 45 (4*ET)
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 46 (4*ET)
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 47 (4*ET)
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 48 (4*ET)
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 49 (4*ET)
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 50 (4*ET)
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 51 (4*ET)
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 52 (4*ET)
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 53 (4*ET)
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 54 (4*ET)
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 55 (4*ET)
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used
for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder
connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other
BSC).
90 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)
LAN INTERFACES
10/100/1000Base-T/Tx uplinks 1000Base-Sx uplinks
00 01 02 03 04 05 06 07
IEC/EN 60825 - 1
08 09 10 11 12 13 14 15
Tx Rx Tx Rx Tx Rx Tx Rx
SYMM 0 SYMM 1
20 ASYMM 0 21 22 23
LPT 0 VDU 0 CLS 0, 1 CLS 0, 1 CLS 0,1
16 17 18 19
(V.24) (V.24)
28 ASYMM 1
VDU 1 VDU 2 VDU 2 LPT 2 CLS 0,1
24 24 26 27
(V.24) (V.24) (V.11) (V.11)
CURRENT-
CONTROLLED
EXT SYNC IN EXT AL INPUT EXT AL OUTPUT AL INPUTS
LPT/VDU INTERFACES INTERFACES EXT AL INTERFACES
B A
DN0626528
Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation inter-
faces - seen from the front of the cabinet
The various interfaces are presented in the following sections:
LAN interfaces
External alarm cabling
LPT/VDU interfaces
External synchronisation cabling
DN70617303 Id:0900d805804ab823 91
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i
Dust 30 5
caps to LC DN70631285
connectors
Figure 21 Optical LC connectors, straight type
The following table presents the main characteristics of the optical cables and connec-
tors.
The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70 and the requirements of the FCC Part
68.
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable)
92 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable) (Cont.)
The pin configuration in 1 Gbit/s use of the CNIX cable connector is presented in the fol-
lowing table.
The pin configuration in 10/100 Mbit/s use of the CNI cable connector is presented in
the following table.
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable)
DN70617303 Id:0900d805804ab823 93
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i
Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable) (Cont.)
The pin configuration in 1 Gbit/s use of the CNI cable connector is presented in the fol-
lowing table.
The main characteristics of 10/100 Mbit/s /1 Gbit/s copper LAN cables are presented in
the following table.
Table 45 Recommended cable types for LAN cables (CNI and CNIX)
The LAN interfaces complying with the IEEE 802.3 standard for Ethernet serial inter-
faces are of 10 Base-T and 100 Base-TX.
For more information, see Requirement specifications for external cables of M98
mechanics BSC3i and TCSM3i equipment.
94 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors
DN70617303 Id:0900d805804ab823 95
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors (Cont.)
Alarms AEO0-AEO11 are connected directly to the EXAU-A with cable CNDE. All
alarms AEO0-AEO15 can be connected to the cross connection (DDF) with cable CNDE
(the other cable end, connector 2, cut off).
Four lengths of CNDE cable are available (ID codes presented):
5 m: C106809
10 m: C106819
20 m: C108435
96 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)
50 m: C107185
DN70617303 Id:0900d805804ab823 97
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i
Voltage controlled external alarm input signals are connected from MDF to CPRJ45-A
panel using CYR cable. Three lengths are available (CS codes presented):
35 m: CS73131.35
50 m: CS73131.50
70 m: CS73131.70
24 external voltage controlled alarm inputs can be connected to Flexi BSC using the
CYR cable.
98 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)
Current-controlled external alarm input signals are connected from MDF to CPRJ45-A
panel by using the CYV cable.
One length of the cable is available (ID code presented): 20 m (C72239).
Six external current-controlled alarm inputs can be connected to the Flexi BSC by using
the CYV cable.
Cable type: 12 pairs, twisted, shielded, cross section 0.4 mm2, Milliflex3
SH AWG26/8 pairs
Cable connector: 25-pin D connector (male/female)
DN70617303 Id:0900d805804ab823 99
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i
The EXAU-A has also a second D25 connector which makes is possible to chain several
alarm units so that the alarms can be displayed on more than one unit. See figure Instal-
lation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers.
SW1 BUZZER SELECT
ON LS1
CAUTION 48V AL00 - 1
2 AL01 - 2 J1
F1
GND AL02 - 3 2
J1 AL03 - 4
AL04 - 5 3
AL05 - 6
7 SW2 SW1
134
3 8
140
PCB
Base
4
Cover
Alarm 1
AL00
Alarm 2 PCB
AL01
Alarm 3
1 AL02
Alarm 4
AL03
Alarm 5 Buzzer Reset
AL04
Alarm 6
AL05 Test
Silent Mode
5
DN068749
Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the
buzzer jumpers
The colours of the alarm signals are shown in the following table.
The VDU can be connected to the CPRJ45-A panel by using the CNM cable, which is a
CNI-type cable provided with an RJ45 connector and a D9 connector. The LPT printer
can be connected to the CPRJ45-A panel using the CNP cable, which is a CNI-type
cable provided with an RJ45 connector and a D25 connector. See the following figure.
DE9F
CMN-cable L 1 (female)
RJ45F
(female)
B
A
B
VIEW B-B
1
2
VIEW A-A
RJ45F
CNP-cable L 3
2
(female)
C DB25M
(male)
C
1 1 POSITION NUMBER 1
VIEW C-C
2 UNC-40 male locking screws
USE CABLE OUTLET
3
OPTIMISING BUSHING
D D
CONNECTION CNM-cable CONNECTION CNP-cable
Conn. hood shield Conn. hood Conn. hood shield Conn. hood
DN02237579
Figure 23 Peripheral cables; CNM for VDU and CNP for LPT
Recommended cable types for V.24/V.11 cables (CNI) are shown in the following table.
The cable and the connector meet the requirements of the UL 1459 standard or the
National Electrical Code ANSI/NFPA No.70. The connector also meets the require-
ments of the FCC Part 68.
Balanced (symmetric)
The pin configuration for connectors 18 (SYMM0 CLS 0,1) and 19 (SYMM1 CLS 0,1),
and colours for CNI cable connector are presented in the following table.
Recommended cable types for balanced synchronisation cable (CNI) are shown in the
following table.
Unbalanced (asymmetric)
The pin configuration for connectors 20 and 28 is shown in the following table.
CPGO
DN0626582
Figure 24 CPGO
The cables and the connectors meet the requirements of the UL 1459 standard or the
National Electrical Code ANSI/NFPA No.70 as well as the requirements of the FCC Part
68.
B
Dust 30 5
caps to LC DN70631285
connectors
Figure 25 Optical LC connectors, straight type
Main characteristics of optical cables and connectors are shown in the following tables.
For more information on the optical cables, see Requirement specifications for external
cables of M98 mechanics Flexi BSC product family and TCSM3i.
Cable material:
Shielded construction, screening effectiveness > 60 dB at 1GHz
AWG 26 conductors
Continuous pair twisting on the twisted pair cables
Operating temperature 0 to 80C
VW-1 materials
Optional:
Halogen free materials (IEC 332-1 or IEC 332-3)
Grey colour (RAL 7036, if available)
Connectors:
Coaxial connectors: SMB/50 /straight type
Connectors:
BNC type
Connectors:
RJ45
Connectors:
Shielded 8-pole plug RJ45
Connectors:
Shielded 8-pole plug RJ45
Connectors:
Shielded 8-pole plug RJ45
Connectors:
25-pin D-subminiature connector at both ends of the cable
Connectors:
25-pole male D-connectors
Connectors:
male 9-pin D-connector at one end of the cable
Connectors:
25-pin D-subminiature connector at one end of the cable