Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Horizontal reinforcement: The peripheral moment is small, the reinforcement depends on

nominal reinforcement or compression force. Provide H25-200 having As = 1884 mm2/m =>
OK.
4.3 Base Slab
4.3.1 Analysis and result
Moment M11 Moment M22 Moment M12 Axial force Shear V13 Shear V23

Reinft in X axis Reinft in Y Max = 10 The axial Max = 65 Max = 65


Max = 6 kNm/m axis kNm/m at force: N = kN/m kN/m
Min = -50 Max = 6 corner. 65+59 =
kNm/m kNm/m Min = 1 124kN/m
Min = -50 kNm/m at
kNm/m middle

4.3.2 Reinforcement design


Thickness = 400mm
Reinf in X direction: Required reinforcement is less than nominal bar As_nom = 420 mm2/m.
Provide H25-150 having As = 1884 mm2/m => OK
Shear check: No shear link is required.
Reinf in Y direction: Same as reinforcement in X direction.
4.4 Pipe Design
Use 4 pipe per chamber the loading as followings:
DL = 394 kN
LL = 105 kN
Uplift = 125 kN
Negative skin friction on the surface of the chamber:
Depth of chamber H = 3.7m
Width of chamber B = 4.34m
Length of chamber L = 4.54m
Average effective stress acting on the surface: v = *H/2 = 8*3.7 = 29.6 kPa
Negative skin friction:
NSF = *v*2*(B+L)*H = 0.25*29.6*2*(4.34 + 4.54)*3.7 = 486 kN
No of pile = 4 => NSF = 486/4 = 121.5 kN per pile