This document provides information on calculating the full flow capacity of a circular pipe using the Manning formula. It includes input data for a pipe with a roughness coefficient of 0.015, slope of 0.003 m/m, normal depth of 12 inches, and diameter of 12 inches. The discharge was calculated to be 47.88792 L/s. A rating curve plot was generated from the input data and Manning formula calculations.
This document provides information on calculating the full flow capacity of a circular pipe using the Manning formula. It includes input data for a pipe with a roughness coefficient of 0.015, slope of 0.003 m/m, normal depth of 12 inches, and diameter of 12 inches. The discharge was calculated to be 47.88792 L/s. A rating curve plot was generated from the input data and Manning formula calculations.
This document provides information on calculating the full flow capacity of a circular pipe using the Manning formula. It includes input data for a pipe with a roughness coefficient of 0.015, slope of 0.003 m/m, normal depth of 12 inches, and diameter of 12 inches. The discharge was calculated to be 47.88792 L/s. A rating curve plot was generated from the input data and Manning formula calculations.
Project Description Friction Method Manning Formula Solve For Full Flow Capacity
Input Data
Roughness Coefficient 0,015
Channel Slope 0,00300 m/m Normal Depth 12,00 in Diameter 12,00 in Discharge 47,88792 L/s
Rating Curve Plot
Bentley Systems, Inc. Haestad Methods Solution
Bentley FlowMaster Center V8i (SELECTseries 1) [08.11.01.03] 31/01/2017 9:02:13 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1