COLUMN SCHEDULE
A
BL
QI
1.Notes
ALL DIMENSIONS ARE IN MILLIMETER U.N.O.
2. ALL THE LEVELS ARE IN METER.
3. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE RELATION BETWEEN
THE BUILDING LEVELS AND THE PROJECT DATUM.
4. GENERAL NOTES, STANDARD DETAILS, WATERPROOFING AND MATERIAL
PROPERTIES REFER TO DRAWINGS. " S001 - S005"
5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH THE RELATIVE
ARCHITECTURAL, MEP AND CIVIL DRAWINGS. COORDINATE ALL
PENETRATIONS CONDUTES AND EQUIPMENT REQUIREMENTS.
WATCH TOWER
TYPE 4
500 Dia
10T20
PARKING ROOF
TYPE 9 TYPE 10 TYPE 9
250X600 700X700 250X600
8T20 20T25 8T16
2T10-200 LINKS 3T10-200 LINKS 2T10-200 LINKS
LEVEL 1
TYPE 1 TYPE 2 TYPE 2 TYPE 3 TYPE 8 TYPE 1 TYPE 3 TYPE 7 TYPE 10 TYPE 5 TYPE 9 TYPE 9
250X800 250X800 300X800 250X1000 250X1000 250X800 300X1000 500X500 700X700 400X1000 250X600 250X600
10T20 12T20 12T20 14T25 16T25 10T20 14T20 16T20 20T20 14T25 8T16 8T16
2T10-200 LINKS 3T10-200 LINKS 3T10-200 LINKS 4T10-200 LINKS 4T10-200 LINKS 2T10-200 LINKS 4T10-200 LINKS 2T10-200 LINKS 3T10-200 LINKS 4T10-200 LINKS 2T10-200 LINKS 2T10-200 LINKS
GROUND
COLUMN STARTER BARS TO MATCH BAR SIZE,GRADE& ARRANGEMENT AS PER FIRST LIFT OF WALL U.N.O.
STARTER BARS RBU BM* AH* 08.03.15
A ISSUED FOR TENDER
LEVEL C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 UC1 UC2 UC3 Job Project
MARK No Revision Drawn Manager Director Date
REMARKS
Note: * indicates signatures on original issue of drawing or last revision of drawing
Conditions of Use. This document may only be used by GHD's client (and any other
person who GHD has agreed can use this document) for the purpose for which it was
prepared and must not be used by any other person or for any other purpose.
Lead Consultant
Specialist Consultant
Specialist Consultant
TYPE 7 TYPE 8 TYPE 9 TYPE 10
Third Party
Operational Advisor
Client
ADAC
Project
MIDFIELD TERMINAL FIRE
STATION
Title