LTE Attach Messaging PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

EventHelix.

com
telecommunication design
systems engineering
real-time and embedded systems

LTE Attach and Default Bearer


Setup Messaging
2012 EventHelix.com Inc.
All Rights Reserved
EventHelix.com
LTE Attach Message telecommunication design
systems engineering

Sequence Chart real-time and embedded systems

eNodeB MME SGW HSS

Initial UE Message
Update Location Request

Update Location Answer

Create Session Request

Create Session Response

Initial Context Setup + Attach Accept +


Activate Default Bearer

Initial Context Setup Response

Attach Complete + Activate Default Bearer Accept


Modify Bearer Request

2012 EventHelix.com Inc. 2


EventHelix.com
telecommunication design
systems engineering
S1AP: eNodeB MME real-time and embedded systems
S1AP Initial UE Message Id: eNB UE S1AP ID

Initial UE Message is the first Tracking Area Code


message sent to the MME to Tracking Area Id
establish a connection Cell Id
The eNode uses the eNB-UE-S1AP-
ID to uniquely identify the UE

S1AP Initial UE Message


EPS Attach
EPS attach type may be: EPS attach type
EPS Attach: UE is attaching only Combined EPS/IMSI
to the 4G LTE network Attach
Combined EPS/IMSI Attach:
IMSI
The UE identity is specified is:
IMSI: If the UE has is not Attach Request Identity
registered with the network Old GUTI
Old GUTI: Subsequent attach EPS Encryption
Algorithm Supported
requests identify the UE with the
Old GUTI
EPS Integrity
Algorithm Supported

PDN Type: IPV4


Connection Request
Type: Initial Attach

2012 EventHelix.com Inc. 3


EventHelix.com
S6A: MME HSS telecommunication design
systems engineering
Diameter Update Location real-time and embedded systems
Request
Update Location
MME updates the UE location with Command Code
Request
the HSS
S6a interface
Origin and Destination are Application Id
application
specified as Host and Realm
(domain) Host
The user name in the request is set Origin

Diameter Update Location


to IMSI Realm
The Radio Access Technology is
specified in the RAT Type

Request
Host
It will be set to EUTRAN for LTE
Destination
access
Realm
The Visited PLMN is also included
in the message
User Name IMSI

RAT Type EUTRAN

MCC
Visited PLMN Id
MNC

2012 EventHelix.com Inc. 4


EventHelix.com
S6A: MME HSS telecommunication design
systems engineering
Diameter Update Location Result Code: Success
real-time and embedded systems
Answer Subscriber Status:
Service Granted
The HSS accesses the database and Maximum Requested
Bandwidth Uplink
responds with user information to the

Diameter Update Location


Aggregate Maximum
Bit Rate
MME Maximum Requested
Bandwidth Downlink
The Aggregate Maximum Bit Rate (AMBR) Access Restriction

Answer
Data
occurs twice in the message: Called Station Id
The first occurrence specifies the MSISDN
maximum bit rate for the default PDP
PDN Type IPV4
context
The second occurrence specifies the data
maximum data limit via the APN. These PDN GW Address
limits are specified by the PDN
APN configuration also includes: PDN GW Name
APN Configuration
IP address of the PDN Gateway. This Profile
address is used to determine the default QCI specifies BER,
QoS Class Identifier
Priority, GBR
route for the traffic towards the Internet
IP address assigned to the UE (Served Served Party IP
Party IP Address) Address

3GPP Charging
Characteristics
Maximum Requested
Bandwidth Uplink
Aggregate Maximum
Bit Rate
Maximum Requested
Bandwidth Downlink

2012 EventHelix.com Inc. 5


EventHelix.com
Default Bearer telecommunication design
systems engineering

Establishment real-time and embedded systems

MME SGW:
Create Session
Request

SGW PGW: The SGW asks


the PGW to
Create Session establish the
Request bearer

SGW PGW: The PGW


establishes the
Create Session bearer and
responds back to
Response the SGW

MME SGW: The SGW


responds
Create Session back to the
Response MME

2012 EventHelix.com Inc. 6


IMSI
EventHelix.com
S11: MME SGW telecommunication design
RAT Type EUTRAN systems engineering
GTP Create Session real-time and embedded systems
Request TEID

MME initiates the default route Sender F-TEID for


MME IP Address
Control Plane
establishment by asking the SGW
to create a GTP tunnel EPS Bearer Id
The source is identified by the fully
qualified endpoint identifier with PDN Type IPV4 OR IPV6

GTP Create Session Request


the Tunnel Endpoint Identifier
ARP
(TEID) and the MME IP Address
Bearer Context
The IP Address assigned to the UE QCI
QCI specifies BER,
Priority, GBR
is also included along with the MSISDN
downlink and uplink maximum
data rates allowed at the APN level TAI MCC, MNC, TAC

The TAI and ECGI (E-UTRAN Cell


ECGI Contents MCC, MNC, ECI
Group Identifier) information
identify the current location of the
TEID
user PGW S5/S9
Address for Control
PGW IP Address
PDN IP Address

APN
IP Address
PDN Address Assigned to UE
Allocation Aggregate Max Bit Downlink and
Rate APN Limit Uplink

2012 EventHelix.com Inc. 7


S1AP: eNodeB MME EventHelix.com
S1AP Initial Context Setup Request telecommunication design
NAS Attach Accept systems engineering
Activate Default Bearer Request real-time and embedded systems

The next message from the MME is


really a three-in-one. The message

Accept/ Default Bearer Request


Initial Context Request / Attach
contains:
SIAP Initial Context Setup Request
A request to establish a context S1AP Initial Context
S1AP PDU
between the MME and eNodeB Setup Request
The message contains SGW
tunneling information EPS mobility
NAS Attach Accept NAS Attach Accept
management messages
This message acknowledges the
successful Attach to the UE.
The eNodeB will pass this
EPS session Activate Default Bearer
message to the UE management messages Request
Activate Default Bearer Request
The message initiates the default
bearer setup on the UE
The eNodeB will pass this
message to the UE

2012 EventHelix.com Inc. 8


EventHelix.com
S1AP: eNodeB MME telecommunication design
MME UE S1AP ID systems engineering
S1AP Initial Context Setup real-time and embedded systems
Request ENB UE S1AP ID
The MME responds with MME UE Downlink
S1AP ID that was received from Aggregate Max
the eNodeB in the initial UE Bitrate (AMBR)
Uplink
message

SIAP Initial Context Setup


The message also contains the
MME UE S1AP ID QCI
The message contains the

Request
maximum aggregate bit rate eRAB Max Bit Rate
information. Downlink
The message also contains the eRAB Max Bit Rate
information about the default Uplink
eRAB.
QCI to assign session priority RAB Guaranteed Bit
eRABs to Setup eRAB ID
Rate Downlink
The maximum bit rate for the
eRAB
Encryption RAB Guaranteed Bit
Guaranteed bit rate for the eRAB Algorithm Rate Uplink
Transport Layer Address assigns UE Security
the IP Address for the user plane Capability
Integrity Protection Transport Layer
entity on the S-GW Algorithm Address
GTP TE ID identifies the S-GW Security Key
end of the user plane tunnel GTP TE ID
The security capabilities specify
the encryption and integrity
protection algorithm to be used
for the UE session
2012 EventHelix.com Inc. 9
EventHelix.com
eNodeB MME telecommunication design
systems engineering
UE eNodeB real-time and embedded systems
NAS Attach Accept
The Attach Accept is carried as
NAS payload in the Initial Context EPS Attach Result EPS Only
Setup Request
The message specifies that the T3412
attach has been successful. The Type One PLMN

NAS Attach Accept


terminal is attached to the EPS
only (i.e. LTE only, no SGSN TAI List
PLMN
registration)
Partial TAI List
The T3412 timer specifies the
maximum time between tracking TAC List
area updates from the terminal MCC
The TAI list in the message
specifies the PLMN and the MNC
Tracking Area Codes for all the
registered tracking areas
The message contains GUTI. GUTI GUTI MME Group Id
uniquely identifies the UE with
PLMN, MME Group, MMC code GPRS Ready Timer MME Code
and the M-TMSI
Finally, the GPRS Ready timer is
included in the message. M-TMSI
The UE will be transitioned to
IDLE if no activity is detected for
this period

2012 EventHelix.com Inc. 10


eNodeB MME EventHelix.com
UE eNodeB telecommunication design
systems engineering
Activate Default Bearer real-time and embedded systems
Request
The Attach Accept is carried as
NAS payload in the Initial Context
Setup Request QCI
The EPS Bearer id identifies the
bearer that needs to be activated
eRAB Max Bit Rate
The EPS QoS carries quality of EPS Bearer Id

Activate Default Bearer


service information: Downlink
QCI to assign session priority

eRAB Max Bit Rate
The maximum bit rate for the EPS QoS

Request
bearer Uplink
Guaranteed bit rate for the
bearer RAB Guaranteed
The Access Point Name (APN) is Access Point Name
Bit Rate Downlink
included in the message
The PDN IP address assigned by RAB Guaranteed
the HSS is passed to the UE PDN Address
Bit Rate Uplink

2012 EventHelix.com Inc. 11


EventHelix.com
eNodeB MME telecommunication design
Initial Context Setup systems engineering
Response real-time and embedded systems

The eNodeB sends the Initial


Context Setup Response message
to the MME.
The message confirms the

S1AP Initial Context Setup


establishment of the GTP tunnel
on the S1-U interface MME UE S1AP ID

Response
The message contains information
about the RABs that are being eNB UE S1AP ID E-RAB ID
established at startup.
Transport Layer
The following information is E-RAB Setup List E-RAB Setup Item
Address
present for each RAB
The E-RAB ID GTP TEID
The transport layer IP address on
the eNodeB.
The eNodeB GTP Tunneling ID
(TEID) for the eNodeB side.

2012 EventHelix.com Inc. 12


EventHelix.com
Completing the Attach and telecommunication design
systems engineering

Default Bearer Activation real-time and embedded systems

eNodeB MME: eNodeB transports


Attach Complete and
Attach Complete Activate Default
Bearer Accept
+ Activate Default The message was
Bearer Accept received from the UE

Inform SGW
MME SGW: about the
Modify Bearer eNodeBs user
plane IP address
Request and GTP TEID

2012 EventHelix.com Inc. 13


EventHelix.com
telecommunication design
Thank You systems engineering
real-time and embedded systems

Thank you for visiting EventHelix.com. The following links provide more information
about telecom design tools and techniques:

Links Description
EventStudio System Designer Sequence diagram based systems engineering
tool.
VisualEther Protocol Analyzer Wireshark based visual protocol analysis and
system design reverse engineering tool.
Telecom Call Flows GSM, SIP, H.323, ISUP, LTE and IMS call flows.
TCP/IP Sequence Diagrams TCP/IP explained with sequence diagrams.
Telecom Networking Software Real-time and embedded systems, call flows and
object oriented design articles.

2012 EventHelix.com Inc. 14

You might also like