Results Pages From Senior

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Calculations:

Pump Head For Storage


1.85
H=10.68 ( ) ( dL )
Q
C 4.87

1.85
0.035
10.68 ( 120 ) ( 0.15188 ) 4.87

=0.01693 m

Pump Head = Head loss + height of OHT in ft + Water Table +Draw Down in
ft+ Safety factor.

= 6.06 + 20 + 3.048 + 3.048 + 40 + 3.04

= 73

Pump Head For Direct:


1.85
H=10.68 ( ) ( dL )
Q
C 4.87

1.85
0.035 2.25
10.68 ( 120 ) ( 0.34127 )4.87

=24.36

Pump head = head loss + water table + draw down + safety factor

= 24.36+40+3.048+3.048

= 71

Extra head is added in order to maintain the pressure.


Cost Analysis:

Cost Analysis of Over Head Tank (OHT):


1
Capacity of tank or OHR = 4 35lit/sec
=31.5m 3/hr

Capacity of one OHR or tank =378m 3 (for 12 hours)

For diameter
Say depth of OHR =3.02m

3
378 m = A 3.02
2
Area = A = 125.17 m

2
Area = d 4 =125.17 m2

Diameter = d = 12.63m

Cost of over head tank:


Price /m3=42328 Rs

Price of OHT=378*42328

=15.9million
Cost Of Pipes Network:
Indirect Pumping:
Diamet
er Length m cost /m Total cost

50 750 551 413250


75 3825 895 3423375
100 5500 1285 7067500
150 3900 2069 8069100
1897
3225

Direct Pumping:
Diamet
er Length m cost /m Total cost
75 8125 895 7271875
100 4800 1285 6168000
13439875

Cost of Pumps:
Indirect Pump=0.15m Manufacturer (shalamar pump manufacturer Lahore)

Direct Pumping:0.14m Manufacturer(do)

Total cost for pumping with storage project:


0.15 + 18.97 + 15.9

= 35.02 million

Total cost for direct pumping:


13 + 0.14

= 13.14 million

Total cost for the whole project:


35.02 +13.14
= 48.16 million

References:

Water supply and sewerage by E.W. Steel

en.wikipedia.org/wiki/Water_supply_network

www.engineeringtoolbox.com/water-supply-systems

www.level.org.nz/water/water-supply/system-layout-and-pipework

www.wmwd.com/DocumentView.asp

You might also like