Regenerative Technology
Regenerative Technology
Regenerative Technology
Regenerative Converter
D1000
200 V Class, 5.0 kW to 130 kW
400 V Class, 5.0 kW to 630 kW
NEW
Regenerative Unit
R1000
200 V Class, 3.5 kW to 105 kW
400 V Class, 3.5 kW to 600 kW
Matrix Converter
Varispeed AC
200 V Class, 5.5 kW to 45 kW
400 V Class, 5.5 kW to 160 kW
Save Energy by Reusing Previously Wasted Energy!
Return the energy produced by your equipment (regenerative energy) to the power supply.
Use Energy
Effectively!
AC drive
Lowering (regenerative energy) AC drive Lowering (regenerative energy)
Braking Energy-saving Unit
resistance
Regenerative energy Power supply
di
discarded as heat. energy for other devices Regenerative energy is effectively
returned to the power supply.
Wasteful!
Effectively use regenerative energy that
results from lowering the load without waste!
Applicable items
2
The Elite of Complete Power Savings!
Regenerative Converter
D1000
In Pursuit of Power Quality
Note: Certification pending
Achieve higher power factors and suppress harmonics for power supplies
Compliant by installing an AC drive.
Restriction of Hazardous Substances Directive
Connect
3 Multiple Units
Stable power supply is enabled
by DC links between multiple AC
drives.
D1000
Links enabled between
multiple AC drives and
motors
Application
Save Electricity with Power Regeneration Improved Power Factors and No Power Supply Harmonics
Examples Lift applications with heavy repetitive loads and Variable-speed applications in hospitals, schools,
regenerative power office buildings, etc. with strict requirements for
Equipment with multiple axes harmonic distortion
Automatic Parking
System Escalators Elevators Climbing Cranes Film Slitters Pumps Cooling Towers HVAC Compressors
3
Regenerative Unit
R1000
Compact with More Braking Power
Note: Certification pending
Change from previous braking resistor configuration to the R1000 unit to
Compliant save energy, increase braking power, and downsize equipment.
Restriction of Hazardous Substances Directive
Braking Unit
More Braking Power Previous configuration (Example for LKEB4045) R1000 High
1 Braking torque is increased to increase 125% (10 s) 150% torque (30 s) Torque
the braking power of the equipment
with continuous regenerative operation.
Previous configuration R1000
Machine Downsizing
2 The system configuration is much smaller
Current Suppression
Footprint
reduced
than for a braking resistor system so that Braking Reactor by approx.
R1000
you can save space in control panels. resistor Braking
unit 62%
Power Coordinating Reactor (in-house comparison)
Total Cost Reduction Example for 400 V, 45 kW
3 Power regeneration by the R1000 helps
you hold down running costs. Example for Application to a Lift
Energy Savings Speed
Lifting
0
Previous configuration 110% 90% Lowering
Torque 71%
Power consumption (drive): Reduction of approx. 0
-40% -60%
49.5 kW
8.83 kW (1 cycle) -80%
Approx. $2,100 per year
$1,140 per year 40.5 kW
32 kW
R1000
(Conditions) Power Drive Regeneration An Approx.
Rated load: 10 t 0 54% Savings in
Power consumption (drive): Rated lifting speed: 20 m/min -13 kW
-22 kW Electricity Costs
8.83 kW (1 cycle) Motor used: 45 kW, 4 poles, 1,750 min-1
-30 kW
Regenerated power:
No. of Time for Return
lifting/lowering: 25 times/h; 109,500/yr 2 15 s 2 20 2 15 s 2 20 on Investment:
4.78 kW (1 cycle) (12 h/day for 365 days) s s s s s s
Electricity costs: $10/kWh 78 s Approx. 1.5 yr
Approx. $960 per year
Application
Save Electricity with Power Regeneration Improved Power Factors and No Power Supply Harmonics
Examples Lift applications with heavy repetitive loads and Equipment with large brakes
regenerative power Equipment that requires frequent braking
Decanters,
Automatic Parking Automated Vertical Centrifugal
System Escalators Hoists, Cranes Storage System Separators Conveyors Presses Carriage
4
Matrix Converter
Varispeed AC
The Pursuit of Compact, All-in-one Perfection
With just one Matrix Converter, you can achieve an AC drive to control the motor speed,
power regeneration, improved power factor, and power supply harmonic suppression.
All in one
Capacitor for Matrix Converter
Harmonic Filter
Application
Save Electricity with Power Regeneration High Power Factor and Power Supply Harmonic Suppression
Examples Lift applications with heavy repetitive loads and Variable-speed applications in hospitals, schools,
regenerative power office buildings, etc. with strict requirements for
harmonic distortion
Decanters,
Automatic Parking Centrifugal
System Climbing Cranes Escalators Elevators Separators Pumps Cooling Towers HVAC
5
Yaskawa Regenerative Energy-saving Unit Series
D1000 Dimensions mm
Regenerative Energy-saving Unit
Voltage Class 200 V Class 400 V Class
Model CIMR- *3
0005 0010 0020 0030 0050 0065 0090 0130 0005 0010 0020 0030 0040 0060 0100 0130 0185 0270 0370 0630
DA *1 A
Width (W) 275 325 450 450 500 275 275 325 325 500 500 670 670 1250
Open-Chassis
Height (H) 450 550 705 705 800 450 450 550 550 800 800 1140 1140 1380
(IP00)
Depth (D) 258 283 330 330 350 258 258 283 283 350 350 370 370 370
Width (W) 180 180 220 279 329 456 456 504 180 180 220 279 279 329 329 504 504
Open-Chassis
Height (H) 300 300 365 515 730 960 960 1168 300 300 365 515 515 730 730 1168 1168
(IP20)
Depth (D) 187 187 197 258 283 330 330 350 187 187 197 258 258 283 283 350 350
*12:: This number indicates the voltage class (2: 200 V class, 4: 400 V class).
*3: For the 200 V class, rated output capacity is calculated with a rated output voltage of 220 V. For the 400 V class, values are given for an input voltage of 440 V.
* Available soon.
Regenerative Energy-saving Unit Harmonic Filter Module Reactor
W
A
C
H C
B
A B
D
R1000 Dimensions mm
Regenerative Energy-saving Unit
Voltage Class 200 V Class 400 V Class
Model CIMR- *2 *2 *2 *2
03P5 0005 0007 0010 0014 0017 0020 0028 0035 0053 0073 0105 03P5 0005 0007 0010 0014 0017 0020 0028 0035 0043 0053 0073 0105 0150 0210 0300 0600
RA *1 A
Width (W) 140 140 140 180 180 220 220 220 275 325 450 500 140 140 140 180 180 220 220 220 275 275 325 325 450 450 500 500
Open-Chassis
Height (H) 260 260 260 300 300 365 365 385 450 550 705 800 260 260 260 300 300 365 365 365 450 450 550 550 705 705 800 800
(IP00)
Depth (D) 167 167 167 187 187 197 197 197 258 283 330 350 167 167 167 187 187 197 197 197 258 258 283 283 330 330 350 350
Enclosed Width (W) 140 140 140 180 180 220 220 220 275 329 450 140 140 140 180 180 220 220 220 275 275 329 329 450 450 *2
Wall-Mounted Height (H) 260 260 260 300 300 365 365 385 450 730 705 260 260 260 300 300 365 365 365 450 450 730 730 705 705
(NEMA Type1) Depth (D) 167 167 167 187 187 197 197 197 258 283 330 167 167 167 187 187 197 197 197 258 258 283 283 330 330
*12:: This number indicates the voltage class (2: 200 V class, 4: 400 V class).
* Available soon.
Note: A Power Coordinating Reactor, a Current Suppression Reactor, and a fuse must be installed for the R1000 unit.
C C
H C
A B
A B
B
D
High performance Compact vector Compact V/f Elevator Advanced vector AC Servo Drives
vector control Drive control Drive control Drive applications control Large-Capacity
A1000 V1000 J1000 L1000A Varispeed G7 Series
7
Varispeed AC Standard Specifications
Voltage Class 200 V Class 400 V Class
Model CIMR-
25P5 2011 2022 2045 45P5 4011 4022 4045 4075 4110 4160
ACA
Max. Applicable Motor Output kW 5.5 11 22 45 5.5 11 22 45 75 110 160
Rated Input Current* A 26 47 91 174 14 26 49 92 157 228 287
Rated Output Capacity kVA 9 17 33 63 10 19 36 67 114 166 209
Output Rated Output Current A 27 49 96 183 15 27 52 97 165 240 302
Characteristics Max. Output Voltage 95% of input voltage
Max. Output Frequency Frequencies supported up to 120 Hz using parameter setting
Rated Voltage and
3-phase, 3-phase, 200/208/220 V, 50/60 Hz 3-phase, 380/400/415/440/460/480 V, 50/60 Hz
Frequency
Allowable Voltage
15 to +10%
Power Supply Fluctuation
Characteristics Allowable Frequency
3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Fluctuation
Allowable Power Voltage
Within 2%
Imbalance between Phases
Input Power Factor Sine-wave PWM [Flux vector control, open-loop vector control, V/f control (switched by parameter setting)]
Control
Control Method 0.95 or more (When the rated load is applied.)
Characteristics
Overload Capacity 150% of rated output current per minute (carrier frequency of 4 kHz)
1 C-relay output at failures, 1 a contact output (multi-function) during operation, 4 multi-function PHC outputs selectable at
Status Output
alarms, Analog input (voltage, current) for analog inputs, 2 multi-function analog outputs selectable for analog outputs
Varispeed AC Dimensions mm
Voltage Class 200 V Class 400 V Class
Model CIMR-
25P5 2011 2022 2045 45P5 4011 4022 4045 4075 4110 4160
ACA
Width (W) 300 300 360 480 300 300 360 480 480 695 695
Open-Chassis
Height (H) 530 530 560 865 530 530 560 865 865 1200 1200
(IP00)
Depth (D) 290 290 300 403 290 290 300 403 403 370 370
Enclosed Width (W) 300 300 360 480 300 300 360 480 480
Wall-Mounted Height (H) 564 564 725 1272 564 564 725 1272 1272
(NEMA Type1) Depth (D) 290 290 300 403 290 290 300 403 403
*: The
The motor capacity (kW) refers to a Yaskawa 4-pole standard motor.
rated current of the MxC output amps should be equal to or greater than the motor rated current.
Varispeed AC