Regenerative Technology

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

NEW

Regenerative Converter

D1000
200 V Class, 5.0 kW to 130 kW
400 V Class, 5.0 kW to 630 kW

NEW
Regenerative Unit

R1000
200 V Class, 3.5 kW to 105 kW
400 V Class, 3.5 kW to 600 kW

Matrix Converter

Varispeed AC
200 V Class, 5.5 kW to 45 kW
400 V Class, 5.5 kW to 160 kW
Save Energy by Reusing Previously Wasted Energy!
Return the energy produced by your equipment (regenerative energy) to the power supply.

Use Energy
Effectively!

Power Regeneration: How To Save Power.


Power regeneration is the function of returning energy to the power supply.
For example, when a crane lifts a load, the motor requires energy.
However, when the crane lowers the load, the weight of the load turns the motor, generating energy.
Traditionally, the generated energy was consumed as heat by the braking resistance, but this energy
can be returned to the power supply and reused to save energy.

Previous Braking Resistor configuration Return Electricity with Power Regeneration

Hoisting (drive energy) Hoisting (drive energy)

AC drive
Lowering (regenerative energy) AC drive Lowering (regenerative energy)
Braking Energy-saving Unit
resistance
Regenerative energy Power supply
di
discarded as heat. energy for other devices Regenerative energy is effectively
returned to the power supply.
Wasteful!
Effectively use regenerative energy that
results from lowering the load without waste!

Applications Best Good N/A

Regenerative Converter Regenerative Unit Matrix Converter


D1000 R1000 Varispeed AC

Applicable items

Without AC drive (required). Without AC drive (required). With AC drive.

Use power regeneration to save energy.


Improve the power factor.
Suppress power supply harmonics.
Reduce the capacity of power equipment.
Apply for multiple drives.
Suppress the cost of introduction.
Downsize control panels.
Simplify main circuit wiring.

2
The Elite of Complete Power Savings!
Regenerative Converter

D1000
In Pursuit of Power Quality
Note: Certification pending
Achieve higher power factors and suppress harmonics for power supplies
Compliant by installing an AC drive.
Restriction of Hazardous Substances Directive

Comparison with Previous configuration

Previous configuration Power Regenerative D1000


Converter D1000

Reactor for AC reactor AC drive


Harmonic Filter Harmonic AC reactor AC drive
Filter Module
Less Wiring Work
Capacitor for and Space Savings
Harmonic Filter

Save Electricity with Power Regeneration and More

Improved Input Power Supply Current Waveform Comparison


1 Power Factor Standard Drive Standard Drive with D1000

With power factor 1 control, power Power factor:


is used without waste to enable
downsizing power equipment.
Approx. 1.0
Compliance with
No Power Supply Large power supply Small power supply
Harmonic
2 Harmonics
current distortion rate.
Power factor:
current distortion rate.
Power factor:
Suppression Guidelines

There are no power supply Approx. 0.7 Approx. 1.0


Condition: Rated load.
harmonics.
You can comply with harmonic
suppression guidelines.
AC drive

Connect
3 Multiple Units
Stable power supply is enabled
by DC links between multiple AC
drives.
D1000
Links enabled between
multiple AC drives and
motors

Application
Save Electricity with Power Regeneration Improved Power Factors and No Power Supply Harmonics
Examples Lift applications with heavy repetitive loads and Variable-speed applications in hospitals, schools,
regenerative power office buildings, etc. with strict requirements for
Equipment with multiple axes harmonic distortion

Automatic Parking
System Escalators Elevators Climbing Cranes Film Slitters Pumps Cooling Towers HVAC Compressors

3
Regenerative Unit

R1000
Compact with More Braking Power
Note: Certification pending
Change from previous braking resistor configuration to the R1000 unit to
Compliant save energy, increase braking power, and downsize equipment.
Restriction of Hazardous Substances Directive

Comparison with Previous configuration

Previous configuration R1000

Braking Unit

Braking Resistor Unit Power


Coordinating
Reactor AC drive

Increased braking Fuse


Current
AC drive
power Compact Suppression
Reactor
R1000

Save Electricity with Power Regeneration and More

More Braking Power Previous configuration (Example for LKEB4045) R1000 High
1 Braking torque is increased to increase 125% (10 s) 150% torque (30 s) Torque
the braking power of the equipment
with continuous regenerative operation.
Previous configuration R1000
Machine Downsizing
2 The system configuration is much smaller
Current Suppression
Footprint
reduced
than for a braking resistor system so that Braking Reactor by approx.
R1000
you can save space in control panels. resistor Braking
unit 62%
Power Coordinating Reactor (in-house comparison)
Total Cost Reduction Example for 400 V, 45 kW
3 Power regeneration by the R1000 helps
you hold down running costs. Example for Application to a Lift
Energy Savings Speed
Lifting
0
Previous configuration 110% 90% Lowering
Torque 71%
Power consumption (drive): Reduction of approx. 0
-40% -60%
49.5 kW
8.83 kW (1 cycle) -80%
Approx. $2,100 per year
$1,140 per year 40.5 kW
32 kW
R1000
(Conditions) Power Drive Regeneration An Approx.
Rated load: 10 t 0 54% Savings in
Power consumption (drive): Rated lifting speed: 20 m/min -13 kW
-22 kW Electricity Costs
8.83 kW (1 cycle) Motor used: 45 kW, 4 poles, 1,750 min-1
-30 kW
Regenerated power:
No. of Time for Return
lifting/lowering: 25 times/h; 109,500/yr 2 15 s 2 20 2 15 s 2 20 on Investment:
4.78 kW (1 cycle) (12 h/day for 365 days) s s s s s s
Electricity costs: $10/kWh 78 s Approx. 1.5 yr
Approx. $960 per year

Application
Save Electricity with Power Regeneration Improved Power Factors and No Power Supply Harmonics
Examples Lift applications with heavy repetitive loads and Equipment with large brakes
regenerative power Equipment that requires frequent braking

Decanters,
Automatic Parking Automated Vertical Centrifugal
System Escalators Hoists, Cranes Storage System Separators Conveyors Presses Carriage

4
Matrix Converter

Varispeed AC
The Pursuit of Compact, All-in-one Perfection
With just one Matrix Converter, you can achieve an AC drive to control the motor speed,
power regeneration, improved power factor, and power supply harmonic suppression.

Comparison with Previous configuration

Previous configuration Power Regenerative Varispeed AC


Converter

Reactor for AC reactor


AC drive
Harmonic Filter

All in one
Capacitor for Matrix Converter
Harmonic Filter

Save Electricity with Power Regeneration and More


All in One
Footprint reduced
Space Savings and by approx. 45%
1 Less Wiring Work Power Regenerative AC drive
Wiring reduced
Converter by approx. 70%
The all-in-one design both reduces (20 6)
wiring and saves space. Peripheral devices
Varispeed AC Weight reduced
by approx. 62%
High Power Factor Example for 200V 22kW

2 and Power Supply Input Power Supply Current Waveform Comparison


Standard Drive Varispeed AC Power factor: More
Harmonic Suppression than approx.0.95
High power factor for control and
suppressed harmonics for power Compliance with
supplies enables you to downsize Harmonic
power equipment and comply with Suppression Guidelines
Large power supply Small power supply
harmonic suppression guidelines. current distortion rate. current distortion rate.
Note: Preferential measures can be taken applied
when extending or renovating facilities,
Power factor:
Approx. 0.7
Power factor: Approx. 0.95
because the coefficient for 6-pulse conversion Test Conditions: One transformer, rated load, input
with the Varispeed AC is very low (0.4). voltage distortion is 1% or less.
Input Power Supply Current Waveform Comparison
Greater Efficiency
3 There is less energy lost in
Previous configuration Varispeed AC
58% less power loss
comparison with previous power Total loss Example for Total loss
5% increased efficiency
regeneration systems because no
peripheral devices are used.
2,189W
(Efficiency:Approx.91%)
200V 22kW
929W
(Efficiency:Approx.96%)

Application
Save Electricity with Power Regeneration High Power Factor and Power Supply Harmonic Suppression
Examples Lift applications with heavy repetitive loads and Variable-speed applications in hospitals, schools,
regenerative power office buildings, etc. with strict requirements for
harmonic distortion

Decanters,
Automatic Parking Centrifugal
System Climbing Cranes Escalators Elevators Separators Pumps Cooling Towers HVAC

5
Yaskawa Regenerative Energy-saving Unit Series

D1000 Standard Specifications


Voltage Class 200 V Class 400 V Class
Model CIMR- *3
0005 0010 0020 0030 0050 0065 0090 0130 0005 0010 0020 0030 0040 0060 0100 0130 0185 0270 0370 0630
DA *1 A
Rated Output Capacity*2 kW 5 10 20 30 50 65 90 130 5 10 20 30 40 60 100 130 185 270 370 630
Rated Output Current (DC) A 15 30 61 91 152 197 273 394 8 15 30 45 61 91 152 197 280 409 561 955
Rating
Rated Input Current (AC) A 15 29 57 83 140 200 270 400 8 16 30 43 58 86 145 210 300 410 560 1040
Rated Output Voltage DC330 V DC660 V
Rated Voltage/Rated Frequency 200 to 240 V50/60 Hz 380 to 480 V50/60 Hz
Input Allowable Voltage Fluctuation 15 to +10%
Allowable Frequency Fluctuation 2%
Control Method Sine-wave PWM control
Control Input Power Factor Input power factor of 0.99 min. (for rated operation)
Characteristics Output Voltage Accuracy 5%
Overload Protection Unit stops after 60 s at 150% of rated output current or after 3 s at 200% of rated output current.
1 C-relay output at failures, 1 a contact output (multi-function) during operation, 2 multi-function PHC outputs selectable at
Status Output
alarms, Analog input (voltage, current) for analog inputs, 2 multi-function analog outputs selectable for analog outputs

D1000 Dimensions mm
Regenerative Energy-saving Unit
Voltage Class 200 V Class 400 V Class
Model CIMR- *3
0005 0010 0020 0030 0050 0065 0090 0130 0005 0010 0020 0030 0040 0060 0100 0130 0185 0270 0370 0630
DA *1 A
Width (W) 275 325 450 450 500 275 275 325 325 500 500 670 670 1250
Open-Chassis
Height (H) 450 550 705 705 800 450 450 550 550 800 800 1140 1140 1380
(IP00)
Depth (D) 258 283 330 330 350 258 258 283 283 350 350 370 370 370
Width (W) 180 180 220 279 329 456 456 504 180 180 220 279 279 329 329 504 504
Open-Chassis
Height (H) 300 300 365 515 730 960 960 1168 300 300 365 515 515 730 730 1168 1168
(IP20)
Depth (D) 187 187 197 258 283 330 330 350 187 187 197 258 258 283 283 350 350

Standard Configuration Devices


Voltage Class 200 V Class 400 V Class
Model CIMR- *3
0005 0010 0020 0030 0050 0065 0090 0130 0005 0010 0020 0030 0040 0060 0100 0130 0185 0270 0370 0630
DA *1 A
Width (A) 209 209 232 260 290 290 290 350 209 209 232 260 260 290 290 350 350
Harmonic
Height (C) 176 184 265 281 348 350 387 500 176 178 265 293 293 348 385 500 500
Filter Module
Depth (B) 285 295 301 305 355 352 352 380 285 295 301 305 305 355 355 380 380
Width (A) 160 205 266 268 330 320 380 445 160 206 230 265 268 330 320 385 450 510 560 560
Input-side AC
Height (C) 133 173 251 290 334 343 382 436 133 173 200 290 285 331 366 382 424 482 549 549
Reactor 1
Depth (B) 114 106 146 161 161 211 220 240 104 101 146 161 176 161 211 235 240 300 320 320
Width (A) 330 385 452
Input-side AC
Height (C) 326 382 545
Reactor 2
Depth (B) 176 220 375
Width (A) 163 182 210
Reactor for
Height (C) 135 150 190
Harmonic Filter
Depth (B) 107 102 102
Width (A) 438 438 695
Capacitor for
Height (C) 502 602 582
Harmonic Filter
Depth (B) 128 128 128

*12:: This number indicates the voltage class (2: 200 V class, 4: 400 V class).
*3: For the 200 V class, rated output capacity is calculated with a rated output voltage of 220 V. For the 400 V class, values are given for an input voltage of 440 V.
* Available soon.
Regenerative Energy-saving Unit Harmonic Filter Module Reactor
W
A

C
H C

B
A B
D

YASKAWA ELECTRIC CORPORATION

DRIVE CENTER (INVERTER PLANT) YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.


2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan 151 Lorong Chuan, #04-01, New Tech Park, 556741, Singapore
Phone: 81-930-25-3844 Fax: 81-930-25-4369 Phone: 65-6282-3003 Fax: 65-6289-3003
YASKAWA AMERICA, INC. YASKAWA ELECTRIC (CHINA) CO., LTD.
2121 Norman Drive South, Waukegan, IL 60085, U.S.A. 12F, Carlton Bldg., No.21 HuangHe Road, HuangPu District, Shanghai 200003, China
Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 Phone: 86-21-5385-2200 Fax: 86-21-5385-3299
YASKAWA EUROPE GmbH YASKAWA ELECTRIC TAIWAN CORPORATION
Hauptstrasse 185, 65760 Eschborn, Germany 9F, 16, Nanking E. Rd., Sec. 3, Taipei, 104, Taiwan
Phone: 49-6196-569-300 Fax: 49-6196-569-398 Phone: 886-2-2502-5003 Fax: 886-2-2505-1280
YASKAWA ELECTRIC KOREA CORPORATION
9F, Kyobo Securities Bldg., 26-4, Yeouido-dong, Yeongdeungpo-gu, Seoul, 150-737, Korea
Phone: 82-2-784-7844 Fax: 82-2-784-8495 LITERATURE NO. CHEP C710600 15A
Published in Japan July 2013 13-7
R1000 Standard Specifications
Voltage 200 V Class 400 V Class
Model CIMR- *2 *2 *2 *2
03P5 0005 0007 0010 0014 0017 0020 0028 0035 0053 0073 0105 03P5 0005 0007 0010 0014 0017 0020 0028 0035 0043 0053 0073 0105 0150 0210 0300 0600
RA *1 A
Regeneration Capacity kW 3.5 5 7 10 14 17 20 28 35 53 73 105 3.5 5 7 10 14 17 20 28 35 43 53 73 105 150 210 300
Rating Rated Output Current (DC) A 14 20 27 41 55 68 81 112 138 207 282 413 7 11 15 22 30 36 43 58 73 89 109 149 217 320 440 629
Rated Input Current (AC) A 10 15 20 30 41 50 60 83 102 153 209 306 5 8 11 16 22 27 32 43 54 66 81 110 161 237 326 466
*2
Rated Voltage/
200 to 240 V50/60 Hz 380 to 480 V50/60 Hz
Rated Frequency
Allowable Voltage
Input 15 to 10%
Fluctuation
Allowable Frequency
2%
Fluctuation
Control Method 120excitation method
Control Input Power Factor 0.9 min. (for rated load)
Characteristics Overload Protection 30 s at approx. 150% of rated current.
Regenerative Torque 150% 30 s, 100% 25% ED 60 s, 80% continuous
1 C-relay output at failures, 1 a contact output (multi-function) during operation, 2 multi-function PHC outputs selectable at alarms,
Status Output
2 multi-function analog outputs selectable for analog outputs

R1000 Dimensions mm
Regenerative Energy-saving Unit
Voltage Class 200 V Class 400 V Class
Model CIMR- *2 *2 *2 *2
03P5 0005 0007 0010 0014 0017 0020 0028 0035 0053 0073 0105 03P5 0005 0007 0010 0014 0017 0020 0028 0035 0043 0053 0073 0105 0150 0210 0300 0600
RA *1 A
Width (W) 140 140 140 180 180 220 220 220 275 325 450 500 140 140 140 180 180 220 220 220 275 275 325 325 450 450 500 500
Open-Chassis
Height (H) 260 260 260 300 300 365 365 385 450 550 705 800 260 260 260 300 300 365 365 365 450 450 550 550 705 705 800 800
(IP00)
Depth (D) 167 167 167 187 187 197 197 197 258 283 330 350 167 167 167 187 187 197 197 197 258 258 283 283 330 330 350 350
Enclosed Width (W) 140 140 140 180 180 220 220 220 275 329 450 140 140 140 180 180 220 220 220 275 275 329 329 450 450 *2
Wall-Mounted Height (H) 260 260 260 300 300 365 365 385 450 730 705 260 260 260 300 300 365 365 365 450 450 730 730 705 705
(NEMA Type1) Depth (D) 167 167 167 187 187 197 197 197 258 283 330 167 167 167 187 187 197 197 197 258 258 283 283 330 330

Standard Configuration Devices


Voltage Class 200 V Class 400 V Class
Model CIMR- *2 *2 *2 *2
03P5 0005 0007 0010 0014 0017 0020 0028 0035 0053 0073 0105 03P5 0005 0007 0010 0014 0017 0020 0028 0035 0043 0053 0073 0105 0150 0210 0300 0600
RA *1 A
Power Width (A) 130 130 130 160 180 180 180 210 210 190 240 265 130 130 160 160 180 180 180 210 210 240 240 270 270 285 320 320
Coordinating Height (C) 105 105 105 130 150 150 150 175 175 240 285 270 130 130 130 130 150 150 150 175 175 205 205 230 230 250 305 340
Reactor Depth (B) 88 88 98 105 100 100 100 100 115 105 105 115 88 98 90 105 100 100 95 100 115 126 126 162 162 168 158 195
Current Width (A) 105 105 105 120 120 120 120 130 130 160 160 180 105 105 105 105 120 120 120 120 130 130 160 160 180 205 205 240
Suppression Height (C) 70 70 70 90 90 90 90 105 105 130 130 155 70 70 70 70 90 90 90 90 105 105 125 125 155 170 175 215
Reactor Depth (B) 61 61 61 71 71 71 71 88 88 89 99 99 61 61 61 61 71 71 71 71 88 98 90 90 99 106 116 126
Width (A) 55 55 55 55 55 55 78 78 87 87 108 108 76.5 76.5 76.5 76.5 76.5 76.5 76.5 76.5 98 98 98 108 108 108 109 109 *2
Fuse Height (C) 18.5 18.5 18.5 18.5 18.5 18.5 25 25 31 31 51 51 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 23.5 23.5 23.5 31 51 51 74 74
Depth (B) 12 12 12 12 12 12 20 20 25 25 25 25 12 12 12 12 12 12 12 12 20 20 20 25 25 25 30 30
Width (A) 65 65 65 65 65 65 88 88 203 203 205 205 85 85 85 85 85 85 85 85 108 108 108 228 205 205 205 205
Fuse Holder Height (C) 17.8 17.8 17.8 17.8 17.8 17.8 17.8 17.8 68.5 68.5 77 77 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 68.5 77 77 77 77
Depth (B) 26 26 26 26 26 26 33 33 177 177 85 85 26 26 26 26 26 26 26 26 33 33 33 177 85 85 85 85

*12:: This number indicates the voltage class (2: 200 V class, 4: 400 V class).
* Available soon.
Note: A Power Coordinating Reactor, a Current Suppression Reactor, and a fuse must be installed for the R1000 unit.

Regenerative Energy-saving Unit Reactor Fuse Fuse Holder


W
A

C C
H C
A B
A B
B
D

D1000/R1000 Connectable Models

High performance Compact vector Compact V/f Elevator Advanced vector AC Servo Drives
vector control Drive control Drive control Drive applications control Large-Capacity
A1000 V1000 J1000 L1000A Varispeed G7 Series

7
Varispeed AC Standard Specifications
Voltage Class 200 V Class 400 V Class
Model CIMR-
25P5 2011 2022 2045 45P5 4011 4022 4045 4075 4110 4160
ACA
Max. Applicable Motor Output kW 5.5 11 22 45 5.5 11 22 45 75 110 160
Rated Input Current* A 26 47 91 174 14 26 49 92 157 228 287
Rated Output Capacity kVA 9 17 33 63 10 19 36 67 114 166 209
Output Rated Output Current A 27 49 96 183 15 27 52 97 165 240 302
Characteristics Max. Output Voltage 95% of input voltage
Max. Output Frequency Frequencies supported up to 120 Hz using parameter setting
Rated Voltage and
3-phase, 3-phase, 200/208/220 V, 50/60 Hz 3-phase, 380/400/415/440/460/480 V, 50/60 Hz
Frequency
Allowable Voltage
15 to +10%
Power Supply Fluctuation
Characteristics Allowable Frequency
3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Fluctuation
Allowable Power Voltage
Within 2%
Imbalance between Phases
Input Power Factor Sine-wave PWM [Flux vector control, open-loop vector control, V/f control (switched by parameter setting)]
Control
Control Method 0.95 or more (When the rated load is applied.)
Characteristics
Overload Capacity 150% of rated output current per minute (carrier frequency of 4 kHz)
1 C-relay output at failures, 1 a contact output (multi-function) during operation, 4 multi-function PHC outputs selectable at
Status Output
alarms, Analog input (voltage, current) for analog inputs, 2 multi-function analog outputs selectable for analog outputs

Varispeed AC Dimensions mm
Voltage Class 200 V Class 400 V Class
Model CIMR-
25P5 2011 2022 2045 45P5 4011 4022 4045 4075 4110 4160
ACA
Width (W) 300 300 360 480 300 300 360 480 480 695 695
Open-Chassis
Height (H) 530 530 560 865 530 530 560 865 865 1200 1200
(IP00)
Depth (D) 290 290 300 403 290 290 300 403 403 370 370
Enclosed Width (W) 300 300 360 480 300 300 360 480 480
Wall-Mounted Height (H) 564 564 725 1272 564 564 725 1272 1272
(NEMA Type1) Depth (D) 290 290 300 403 290 290 300 403 403

*: The
The motor capacity (kW) refers to a Yaskawa 4-pole standard motor.
rated current of the MxC output amps should be equal to or greater than the motor rated current.

Varispeed AC
W