CGT12-120X 12V 120Ah(10hr)

Gel battery shows some distinctive advantages over flooded battery or AGM battery,
such as super thermal stability, high deep discharge capability, good recovery from
deep discharge , even if the battery is left discharged for three days, it will recover
to 100% of capacity. With the above-mentioned advantages, the gel battery has
long service life, specially suitable for motive power applications, such as golf trailer,
sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with
the AGM battery.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper PVC Gelled acid

General Features Performance Characteristics


Nanometer SiO 2 and H 2 SO 4 gelled Nominal Voltage 12V
electrolyte technology for efficiency Number of cell 6
gas recombination of up to 99% and
Design Life 12 years
freedom from electrolyte maintenance
or water adding. Nominal Capacity 77oF(25oC)
Not restricted for air transport-complies
10 hour rate (12.0A, 10.8V) 120Ah
with IATA/ICAO Special Provision A67. 5 hour rate (21.4A, 10.5V) 107Ah
Can be mounted in any orientation.
1 hour rate (87.9A, 9.6V) 87.9Ah
Computer designed lead, calcium tin alloy
Internal Resistance
grid for high power density. Fully Charged battery 77oF(25oC) 5.0mOhms
Long service life, float or cyclic Self-Discharge
applications. 2% of capacity declined per month at 20oC(average)
Maintenance-free operation.
Operating Temperature Range
Low self discharge.
Discharge -20~60oC
Case and cover avaiable in both standard
Charge -10~60oC
and flame restardant ABS.
Storage -20~60oC
Max. Discharge Current 77oF(25oC) 850A(5s)
Dimensions and Weight
Charge Methods: Constant Voltage Charge 77oF(25oC)
Length(mm / inch) 552 / 21.7
Cycle use Charge Voltage: 2.40-2.45VPC
Width(mm / inch) 110 / 4.33
Maximum charging current 36A
Height(mm / inch) 288 / 11.3
Total Height(mm / inch) 295 / 11.6 Temperature compensation -30mV/ oC
Approx. Weight(Kg / lbs) 44.5 / 98.2 Standby use 2.20-2.30VPC
* Weight deviation: 3% Temperature compensation -20mV/ oC

5522 1102 Discharge Constant Current (Amperes at 77oF25oC)


End point
10min 15min 30min 1h 3h 5h 10h
volts/cell
1.60V 243 198 135 87.9 36.2 22.7 12.3
1.65V 227 187 129 85.5 35.6 22.3 12.3
2952
2882

1.70V 212 177 124 83.1 34.7 21.8 12.2


1.75V 196 166 119 80.7 33.8 21.4 12.1
1.80V 180 155 113 78.3 32.9 20.9 12.0
Discharge Constant Power (Watts per cell at 77oF25oC)
2

End point
10min 15min 30min 1h 3h 5h 10h
volts/cell
1.60V 427 360 247 165 68.7 43.6 24.7
M8
1.65V 401 341 238 161 67.4 43.0 24.4
16
1.70V 374 322 230 157 66.1 42.3 24.0
F12
1.75V 349 303 220 152 64.6 41.7 23.8
1.80V 321 284 210 148 63.3 41.0 23.3
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

page1 of 2 www.vision-batt.com
CGT12-120X 12V 120Ah

Discharge characteristic (25 C)


O
Charging characteristic for Cycle use

120 0.17 2.40


12.0
100 0.14 2.20 )Ratio

Charged Volume(%)
Battery voltage(V)

ChargeCurrent(CA)

Voltage(V)/PerCell
Discharge
80 0.11 2.00 100%(0.1CAx10H)
12A ---- 50%(0.1CAx5H)
33.8A 21.4A
60 0.08 1.80 Charge
9.6 Charge Voltage(2.45V/Cell)
240A 120A 87.9A Charge Current 0.1CA
40 0.05 1.60 o
Temperature25 C

0 20 0.02 1.40
1 2 3 5 10 20 30 60 2 3 5 10 20
min h
0 4 8 12 16 20 24
Discharge time Charging time (hours)

Relationship between Self-discharge characteristic


charging voltage and temperature
110
(V/12V)

(V/CELL)
(V/6V)
(V/8V)

(V/4V)

100

90

Capacity(%)
15.6 10.4 7.8 5.2 2.6
80
15.0 10.0 7.5 5.0 2.5

9.6
70
14.4 7.2 4.8 2.4

13.8 9.2 6.9 4.6 2.3 60

13.2 8.8 6.6 4.4 2.2 50

-10 0 10 20 30 40 50 60
40
0 3 6 9 12 15 18 21 24 27 30
Ambient temperature( oC) Storage time: months

Life characteristics of standby use Cycle service life in relation to


120 depth of discharge

100

80
Capacity(%)

60
Testing conditions: floating voltage: 2.27 to 2.30V/Cell
ambient temperature: 25oC(77 oF)
40

20

0
0 2 4 6 8 10 12
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


15

10 2.27V/Cell
Life(years)

Capacity (%)

0
10 20 30 40 50

Temperature( o C)

THE INTERNATIONAL CERTIFICATION NETWORK

MH25860 G4M19906-9202-E-16
ISO9001:2008

Shenzhen Center Power Tech. Co., Ltd. www.vision-batt.com


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)

Page 2 of 2

You might also like