Download as pdf
Download as pdf
You are on page 1of 12
Paper Code-13 20575 BHARAT SANCHAR NIGAM LIMITED Limited Departmental Competitive Examination for promotion to the grade of Sub- nal Engineer (Telecom) under 33% quota Paper-II Advanced Technical Paper Special (Objective Type) (Only for the candidates who have opted for CDOT Digital Switching System(MAX)) Time : 3 Hours Maximum Marks : 100 General Instructions for Candidates: 1. Candidate should read and strictly observe the instructions printed in the Question Booklet as well as the instruction printed on the OMR Answer Sheet. 2. Candidate should not write anything except as directed in the OMR Answer Sheet. 3. In case of any doubt, discrepaney and ambiguity in the Hindi version, the English version should be treated as final 4, The Question Paper has 100 questions. Each question carries one mark. There are four choices for each question. The candidate is required to choose the most appropriate answer from the choices given and darken the relevant bubble against the question number in the OMR Answer Sheet accordingly 5. Candidates are advised not to resort to arbitrary marking of answers as there is negative marking and for each wrong answer 25% marks of that question will be deducted 6. Use of only simple ‘scientific caloulator(non-programmable) is permitted. Va Fs -13 Tea Wr artat soa va feats (dafeaa var) (for sefzant 3 dtete fetrect Rafein res (ees) a faemeT fear t) wa: 3 ae afte 3% ; 100 wdenfttat & feng arara Fez 1. aemell wea after os situsare aon gfinar 8 afta et at ag dea ae ata SUE Rt 2. ede siteror at yferar a Fa TE RET sftfies go 4 fd 3. 8G wane Haig Sey, faa wa fast #9 tists ah set ae TET dare? loom ra 3m wi seam Wee ay Pars 2) hare ary frett # 2 ofa gen a3 at aeqaR aH see gear He & thet at sth 5, Hertel at ae sore fone 25% am ae Fa TT 6. Sarg erry aeits Repay at sails Gas Te RH att SDET2DI0;C_13 t aaa S141 TRYHO—13—1 PAPER-I — Advanced Technical Paper (Special) (Objective type) Section A(I-5) and A(7) - CDOT SWITHING ‘Max. Marks: 100 Time: 3 Hr. candidate: ‘Choose one right answer out of four multiple choice answers. All questions carry equal marks. For each wrong answer 25% of the marks of that question will be deducted under Negative Marking, Al | 1) Inall IN intelligent Network) services all calls must be first routed through PSTN to the nearest: j a) STP | b) SCP ©) SSP* o PF 2) Whatis the SCP code for IN Platform located at Hyderabad: a 345 b) 44 425 d) 233 3) Service charging for a service provider is determined by: wf a) SCE he b) SRF aol? oct! ©) SMAF ae a CCF 4) _IN Service access code for televoting (one unit) is 4 a) 1601xx # ~ b) 1904424 } ©) 1903424 { 1902424 / 5) _ IN Service access code for FPH service is: te a) 1600xxx 4 & b) 160 1x«x ©) 160200 Lodtt 4) 1604xx« bY 6) Service code ‘0902xxx’ is used for the following IN service: —— a) Universal Numbers Local (UNL) / f b) Universal Personal Number : ©) ACC Service a S d) None of the above 7) Fora VCC Call the card used by the customer of BSNL is: 8) Data card b) EVDO Card / ©) India Telephone Card.“ 4) NICCard 8) In Premjum Rate service, the calls made to Premium Rate number a) Not charged to the calling party b) Charged at higher rate than the normal call ©) Charged at normal rate but premium is taken in advance 4) None of the above SoETz010"rC13. * 10) AZ i) 12) 13) 14) 15) 16) 172) SoET2010:°C.13, Within the SDCA b) Within the Circle ) All India 4) Allofabove Which of the following is not an IN service. a) Virtual Private Network b) Account Calling Card ©) Number Portability 4) Calling line Identification. ae Inthe case of Multi frequency Push Button dialling; eh a) —_twossets of eight voice frequency is used 4 pos b) two sets of eight ultrasonic frequency is used ©) _ two sets of four voice frequency is used. ~ 4) two sets of sixteen ultrasonic frequency is used. In subscriber line signaling, Answer Back signal is: a) After the called subscriber lifts his handset a battery reversal is transmitted b) _Afer the called subscriber lifts his handset the line impedance goes high x ©) After the called subscriber lifts his handset, the line impedance goes low ~ 4) Oncompletion of call, the line gets disconnected, For inter exchange signaling the signal transmitted using the same frequency as of speech signal is called: a) Out-of-band signaling ») Voice frequency signaling e ©) Inband signaling - 4) None of the above In E&M signaling between exchanges: a) signaling takes place on the voice channels. b) _Nossignaling takes place between exchanges ¢) The signaling is between calling subscriber and called exchange 4) _ Anaadditional pair of circuit, reserved for signaling, is employed CCITT standardized R2 signating system uses: ) Combination using two out of six frequencies for forward and two out of other six frequencies for backward signaling 'b) Combination two out of 9 frequencies for forward and backward both , ©) frequency same as DTMF 4) Separate frequency set out of speech frequency range In R2 signaling forward signal are used: a) for sending dialed digits only b) for sending address information of called subs and category and wp address information of calling subscriber ~ ©) for demanding callers category 4) None of the above Tn chennel associated signaling: a) Signaling information is sent in time slot 0" of each PCM frame b) Signaling information is sent in time slot “31” of each PCM frame ©) Signaling information is sent in time slot 16” of each PCM frame 4) Signaling information is sent within each time slot, 19) 20) AB 21) 22) 23) 24) 25) 26) 2) speT2010/°C_13, In channel associated signaling, multi frame synchronization information is: a) carried in TS16 of Frame ‘0’. ~ b) carried in TS'0" of Frame ‘0° ©) carried in TSO" of Frame ‘16° ve e 4) carried in TS ‘16° of Frame ‘16" Signaling link in CCSA7 signaling consists of: a) Time slot O and time slot 16 of a PCM link: b) Time slot 16 of Frame “0” of PCM link ©) Signaling data link and its transfer control function 4) __STPandtwo exchanges In CCS#7, user neutral means of transport for messages between user is represented by: a) MIP b) — ISDN-UP °) TUP a sccP In an OSI model, the mains funetion of transport layer is: a) Node to node delivery b) _endto end message delivery - ©) synchronization @) updating and maintenance of routing tables. In ISDN Basic Rate Access the channel available to the customer are: a) One basic channel of 64 kbps & and one data channel of 16 Kops b) Two Basic channels of 64 kbps & two data channels of 16 kbps. ©) Two Basic channels of 64 Kbps and one data channel of 16 kbps “ 4) Thirty Basie channels of 64 kbps and one data channel of 64 kbps. Terminal Adapter (TA) is used: a) Toconvert information received in non-ISDN format into ISDN format “ b) —_Toconnect an ISDN equipment to ISDN line ©) _ Inall ISDN connection at customer premises 4) Toconnect a digital Video conferencing equipment Which of the following is not ISDN customer premises equipment: a) NT b) TA ©) Digital Facsimile @ “rv. ‘Maximum number of terminals that can be supported in ISDN BRI an 4 °c) Be d) Any number ‘The interface between ISDN exchange and NT is called a) R interface b) — Siinterface ©) Tinterface ) — Uinterface The feature of ISDN when a terminal can be carried from place to place and connected to different sockets is known 2s: a) Portability b) Adaptability ©) Multipoint 4) Malti service 29) 30) Ad 31) 32) 33) 34) 39) 36) SpET20701°C.13 Signaling information is not carried by the following channel: a) Dchannel b) ‘B’&‘H’ channel ~ ©) B&D channel 4) D&H channel PRI in BSNL carries: a) 30 B channel + one 16 Kbps D channel b) 23 B channel + one 16 kbps D channel ©) 23 B channel + one 64 kbps D channel 4) 30 B channel + one 64 kbps D channel ~ Ifa digital PABX is to be connected then: a) ISDN BRI is required b) ISDN PRIis required si @ ©) Both ISDN PRI & BRI are required 4) ISDN can not serve the purpose. ‘As per national numbering plan, in Basie telephone network: a) All India based 10 digit numbering scheme is followed ~ b) Long distance charging area (LDCA) based 10 digit numbering has been followed ©) Short distance charging area (SDCA) based 10 digit numbering scheme has been followed 8) Nonof the above {As per numbering plan subscriber number for basic service (PSTN) will be of : b) Tor 8cigits ©) 6, 7,or8digits — d)— 10digits For cellular telephony, the length of PLMN access code, MSC code and subscriber number shall be: a) .2,3,& S respectively « b) 2,4, & 4 respectively ©) 1,3, & 6 respectively 4) __ Nonof the above ASTD barred PSTN phone without using IN service can make calls to: a) PSTN numbers within LDCA and PLMN numbers within circle, b) PSTN number within SDCA and PLMN number within LSA ~ ©) PSTN numbers within the circle and PLMN number within SDCA | 4) __Allmumbers within the Circle Routing of call from a PSTN number to another PSTN number outside the Circle is a) Lev2 TAX —Lev | TAX Lev 2 TAX — Local exch, b) _BTS-BSC-MSC1- MSC-2~BSC-BTS ©) Local exchange ~ Lev 1 TAX — Lev 2 TAX ~Lev 1 TAX - Local exchange d) Local exchange - Lev 2 TAX — Lev 1 TAX - Lev 1 TAX -Lev2 TAX ~Local exchange ~~ Charging for a long distance call in PSTN decided by: a) Leading local exchange b) Leading level-2 TAX - c) Leading Level-l TAX 4) Terminating level -1 TAX 38) 39) 40) AS 41) 42) 43) 44) 49) ‘Synchronization of exchange is most important: 2) Toimprove voice quality b) So that traffic in an exchange is regulated ©) Fordata call - 4) _Else exchange will not work ‘The earthing of power plants is required: a) _ for working logic of the power plant ®) so rovide direst connection wit ah to proce aparts and to provide protection to persons — @ °) to stabilize the power plant physically ~ 4) None of the above ‘As per National Switching Plan all the Lev-1 TAXs are connected generally a) in Mesh topology — b) in Tandem ©) InaRing 4) None ofthe above Charging between two India is decided by: a) _Road/Rail distance between them b) —-X-¥ coordinates ©) Department Of Telecom as per population of cities 4) None of the above Ina SMPS based Power Plants used in telecom system the size of power plant is reduced due to: 4) Use of SCR/Thyrister control b) Use of high frequency switching - ©) —_Use of power plant modules 4) None of the above While planning a SMPS based power plant following factors are taken into consideration: 2) Present and ultimate load of the system b) Battery back up ©) Redundant capacity requirement 4) Allofabove # While choosing DG set fora station, AC requirement for the power plant and UPS system is taken: a) Same as ultimate Power Plant load s b) —1.Stimes the ultimate Power Plant load / ©) 1.25 times the ultimate Power Plant load 4) None of the above. Ifthe present equipment daily load is 192 AH and ultimate daily load is 227 AH, what shall be the best suited battery capacity if depth of discharge is permitted to 0.8 a) 2x1S0AH b) -2x200AH ©) -2x300AH” @)— 1x400AH For a power plant of ultimate capacity of 800 Amp at 54V float voltage, power plant efficiency of 85% and Power plant Power factor of 0.9 the DG set capacity required shall be about: a) TLkw b) sé kw 7 ©) 8Skw 4 dé SOkw. } SDET2010/°C_13, 6 SDET2010/°C_13, Which one ofthe following is not a correct type of Fire extinguishers in a telecom bull a) Fire hydrant # b) —CO2 type ©) Foam type d) — COtype — 47) A7.5 TR air-conditioner in BSNL will be of: a) Split type AIC b) Package type A/C ~ °° Window type A/C 4) Canbe any of the above type 48) _In float mode, voltage in a 300 A SMPS Power Plant is: a) -50V-£0.5 volt fas b) -S4V40.5V ~ es :) -#BV WS, d) +52.4V 40.2 V " 49) A Power plant should not be loaded beyond how much of its rated (ultimate) capacity: a) 100% b) 15% °) 85% © @) 90% 50) The following type of fire extinguishers is not used: 2) Soda type Aa >) Foam type a °) CO2 type d) None of the above. Section A(7) Si. InaCDOT exchange the processor architecture is characterized by: a) ‘Centralized control, token ring based communication b) Centralized control, message based communication c) Distributed control, message based communication ~ 4) Distributed control, token ring based communication/ 52. For inter processor communication: a) HDLC link is used ~ b) El link is used °) TI link is used d) ‘None of the above 53. ‘Due to its redundant architecture, failure of any one security block will effect: t a) Upto 32 subscribers » b) Upto 16 subscribers ©) Upto 8 subscribers qd) No subscribers, 54. ‘Module contro! unit is built around a a) 8 bit Microprocessor b) 16 bit Microprocessor + co) 32 bit Microprocessor 4d) 128 bit Microprocessor 55. All processor complexes in a CDOT DSSMAX switch employs. a) ‘Load sharing’ techniques b) ‘Hot standby’ technique - ©) ‘Cold standby” technique 4) Allof the above "The function using resources whose requirement is diretly linked with number of lines and trunks is a) Terminal interfacing b) Circuit switching ©) Call processing 4d) Alloftheabove / Resource allocation in a CDOT exchange is done by= a) Administrative module ~ ) Central Module ©) Base module d) __ None of the above ‘Trunk and cirouits are interfaced in: 2) Admin module b) Central module ©) Base Module ~ d) None of the above In line circuit card, to form a digital stream: a) 8 bit digital output of 4 LCC are multiplexed a b) 16 bit digital output of 2 LCC are multiplexed. ©) 8 bit digital output of 2 LCC are multiplesed 4) 16bit digital output of 2 LOC are multiplexed ‘The output ofa terminal interface controller card is: ‘a) Duplicated 2 mbps links b) 16 mbps links c) 128 mbps link 4) Duplicated 8 Mbps links « ‘The function of origination detection, digit reception & transmission etc is performed by: ‘) line circuit card b) Signalling Processor Card ©) Terminal interface controller card < 6) Special circuit card NF card provides upto: ight three party conferencing “ Eight four party conferencing” ten four party conferencing Four eight party conferencing [Base message switch is implemented as: 3) a duplicated unit consisting of 16 bit microprocessor and memory and supports Wo MSD cards b) a duplicated unit consisting of 8 bit microprocessor and memory & supports 4 MSD cards ©) anon duplicated unit consisting of 8 bit microprocessor and memory & supports 2 MSD cards 4) anon duplicated unit consisting of 16 bit Microprocessor & memory & supports 4 MSD cards. Each MSD card provide: 4) 4 HDLC channels for communication with other unit 1) BHDLC channels for communication with other units ©) 16 HDLC channels for communication with other units 4) 32 HDLC channels for communication with other units soeT20101°6, 13, ‘Time Switch of a Base Module receives PCM from: a) TIC and BIC = b Ticascic7 7 1 <) TSC&BIC d) SCIC & TSC 66. The cards control Processing unit (CPU) Bus interface device (BID) and Memory Unit (MU) are parts, of a) Central Module (CM) b) Digital Terminal Unit (TU) ©) Time Switch Unit (TSU) ) Base Processor Unit (BPU) ~ 67. Space Switch and space switch controller are parts of: a) Central Processing Unit (CPU) b) Administrative Module (AM) ©) Base Module (BM) 4) Central Module (CM). 68. Space switch is implemented on + a) One MUX card and one SSC card ontX b) Two MUX and two SSC card ©) Two MUX and two SSS cands ¢) Two MUX cards and one SSS card ~ 69. ‘ASIO" card in a CDOT MAX exchange is used for: a) Serial Ports, ~ b) _Interfacing peripheral devices ©) Memory ¢) Communication link 70. _Allthe hardware units of IOP Hardware architecture communication on: a) SCSIBUS 6) CDOT Bus ©) HDLC link — 4) 2 MBPS PCM Tink Ti. The peripherals Disks, Floppy drive, cartridge tape are connected on: a) SCSIBus ~ 6) CDOT Bus ©) HDLC tink ¢) 2 MBPS PCM link 72. _ Below the ‘gnd’ busbar on Power distribution Panel, two more bus bars are placed for: a) termination of AC phase & neutral b) termination of DC + 48 V . ¢) termination of cables from chassis and logie ‘gnd” ~ 4) _ redundancy purpose 73. Twisted pair flat cable with 7x2 module connector one one side and 25 pink D-type connector on other is used for: a) HDLC link between IOP b) Terminal IOP to Serial printer £ ©) APU Frame to JOP~ 4) APU Frame to ADP (MM2) 74. The software sub system responsible for Process management, Process synchronization, inter-process communication, time interrupt & resource management are the function of: a) Call Processing subsystem ¢ b) IOP subsystem ©) CDOT Real time operating system (CDOS) — 4) Administration subsystem Sperz010/°C_13 9 sit TRYNO—13-2 ‘Which subsystem generates on exhaustive Call Event Record (CER) on every call: a) Call Processing ~ b) Peripheral Processor c) Administration 4) Data Base ‘The subsystem responsible for system integrity human interface and initialization a) Maintenance subsystem b) Peripheral processor subsystem ick ©) CDOS ) Administration subsystem ‘What is used by input Output processor sub system as basie operating system a) MS WINDOWS b) — MSDOS. ©) UNIX” 4d) CDOs The feature that is not available in CDOT exchange is a) Direct dialing in (DDI) to a PBX extension A b) Service quality observation for incoming and outgoing calls both“ ) Multi party conferencing service 4) None ofthe above With respect to common channel signaling (CCS#7) in CDOT DSS MAX exchange, which statement i true: ‘The exchange can function as Signaling End point & not signaling transfer point ) The exchange can function both as signaling end point and a signaling transfer point “ ) The exchange can function as signaling transfer point & not as signaling end point 4) The exchange can neither function as signaling end point nor as signaling transfer point. ‘The maximum number of digits that an exchange can receive from a subscriber line is: a 16 b 32 2) 404 do 8 ‘When a subscriber (A) books an alarm call and has activated call diversion to another number (B) then alarm call will : ) goto subscriber (A)only . ) goto subscriber (B) only ~ ©) goto subscriber (A) & (B) both dail Charge meter are dumped to disk at fixed intervals. At any point of time the number of such dumps available on disk for each BM eet Opgeaey: cee a) 4 ‘The charging calendar has provision for: a) 365 days + b) 366 days & ©) 367 days 6) 368 days SDETz010/°C.13 85. 88. 31. 93. Tn case of fault in the individual circuit of Terminal equipment number: a) TEN can be changed with same directory number ~ b) —_Annew directory number is to be given to new TEN ©) TEN cannot be changed 4) None ofthe above In trunk group data management the same set of MML commands can modify: 8) Prefix digits, minimum digits for seize forwards, rank of digit and type of signaling b) Prefix digit, minimum digit for seize forward, type of signaling type of destination exchenge ¢ ©) Prefix digit, minimum digit for seize forward, rank of digit, group priority 4) _ Prefix digit, group priority status (incoming, outgoing both way) rank of digit. , When a subscriber lifts hand set the card that forms the origination message is : aE Tic, ») Tc °) scic 4) BP Digit analysis is done by the card: 5) a b) TSC eee LCC «BP Meter count updation of calling subscribers is done by: a) source AP b) Source BP b ©) destination AP d) destination BP Originating traffic measurement is NOT made for: a) Incomplete dialing b) Transit call attempt ©) —_Unavailability of system resources 6) Nodialing For each newly generated alarm a unique alarm sequence number is assigned. Maximum number of ASN system can allot are: > a) 1024 : & b) 2048 ¢ q 4 ) 4096 d) 81927 In case of severe fault condition where many subscribers are affected, the alarm generated is: a) Urgent alarm b) Severe alarm ©) Critical alarm. 4) Emergency alarm The possiblity of diagnosing a fault to a single PCB level is: a) 50% 65% 85% 4) 95% ‘The memory check does not involve: a) Compare with duplicate memory 7 b) Disk tomemory compare : ©) Active and standby disk compare 4) None of the above SpET2010/°C.13 : W Minimum distance between two suites of CDOT exchange SaowlS Be: a) 600mm 7 ») 900mm 1 ©) 120mm 4) 1500 mm Datum line is a fine: a) Drawn through points located at 600 mm froma wall switch room z >) From which first rack is installed Z ©) From which suites starts « 41500 mm away from the last suite of the switels Call handling capacity of each Base Module is: ¢ a). 2000BHCA ~ et b) 4000 BHCA. ey ©) 8000 BHCA 4) 16000 BHCA Number of Power supply unit (PSU I} in a duplicated base processor unit ae: a) oie Hea et dj. le ‘The following is not a Time Switch Unit card: a) TSS. b) MSC )- Sc d) a ani Single Nelredundancy 7 4) __ None of the above For a total of ‘A’ subscribers, BHCA per BM of “B" and BHCA per line of ‘C” and the value of B/C is less than 750, number of base modiles shal be” — a) A BIC b) A480 A750 é) Single BM, SDET2010:"C_13

You might also like