siemens.

com/energy/transformers

Hear the difference


Siemens Low Noise Transformers

Fit for the future Siemens turns down the volume with high power low noise
In every power supply network,
transformers:
transformers are strategic nodes.
At their location, acoustic environ- Siemens low noise transformer history Low noise transformers
mental protection has now, more Since 2004, Siemens has successfully Made in Austria
than ever, become crucially impor-
designed, produced and tested low noise Siemens Transformers is a central figure
tant. Limited space in cities and
strict noise control regulations
transformers. In terms of their range and with its special skills in low noise issues.
require extra efforts, when build- variety, no other transformer manufac- Here, Siemens designed and produced
ing power transformers. turer can compete with Siemens. These more low noise transformers then
Siemens has answered this chal- Siemens transformers comply with one anywhere else:
lenge for over half a decade and ofthe hardest to reach noise and load 2005: 4 units 2006: 6 units
achieved the best results in reduc- noise requirements: the New York City 2007: 9 units 2008: 8 units
ing transformer noise emission.
M1-R Noise Performance Requirements: 2009: 7 units 2010: 8 units
2011: 7 units 2012: 10 units
Areas of use Passing the New York City M1-R Noise
2013: 18 units.
In acoustically sensitive urban Performance Requirements
locations, particular noise control (20042005) and the new, even stricter The constant advancements and dynamic
regulations apply. Siemens low requirements (from 2007): performance of Siemens Transformers
noise transformers are suitable
2004: 65 MVA transformer keeps its leading position in an ever-
forinstallation:
In urban, metropolitan and other
fromSiemens Nuremberg changing transformer market.
areas of high population density 2004: 65 MVA transformer All aforementioned noise requirements
In sound sensitive areas fromSiemens Linz were reached, even up to 420 MVA, and
In places where stringent noise 2005: 420 MVA autotransformer Siemens is ready to meet any future
regulations apply fromSiemens Weiz specifications.
For Siemens, the reduction of 2007: 234 MVA phase shifting
The leader in compact low noise
acoustic pollution is also a matter transformer from Siemens Weiz
transformer design
ofprinciple. 2007: 234 MVA autotransformer
Since noise reduction is always a matter
fromSiemens Weiz
of space, Siemens low noise transformers
2008: 93 MVA transformer
feature the worlds most compact design.
fromSiemens Linz
While other manufacturers build enormous
2009: 234 MVA autotransformer
noise protection housings, Siemens low
fromWeiz & Nuremberg
noise transformers are chosen for their
2010: 420 MVA autotransformer
compact design which includes internal
fromSiemens Weiz
and external noise reducing arrange-
2010: 2 x 234 MVA autotransformers
ments that help save floor space at full
fromSiemens Weiz
low noise quality.
2013: 234 MVA autotransformers
fromSiemens Weiz
2013: 2 x 300 MVA phase shifting
transformer fromSiemens Weiz

Answers for energy.


Reducing transformer noise Lowest noise worldwide
The load noise emitted by energized Up to 700 MVA and rising, no transformer
transformers consists of no-load noise, competitor can beat the results of Siemens
load current induced noise and cooling ongoing research and development in
equipment noise. The reduction of core building transformers with the lowest
vibration, a classic noise source, is a major noise emissions worldwide. The list below
task in low noise transformer design. shows some examples from the broad
DCmagnetization must be considered variety of the successful Siemens Low
toavoid amplification of core vibration. Noise Transformers in an outstanding
The biggest challenge was the develop- MVA range, of any transformer type, and
ment of a calculation method for load over a period of more than half a decade.
current noise as the understanding of
Low noise masterpiece
load current effects is the basis for noise
The power transformer shown on the
cancellation activities. Consistent research
leftis at present Siemens low noise
in these methods as well as material
masterpiece. At a rated power of 420MVA
properties, has made Siemens low noise
this low noise autotransformer designed
transformers a great success to. Calcula-
in 2010 emits a sound pressure level of
tion models relating to magnetic forces,
merely 52.4 dB(A) at full load. A standard
magnetostriction and, in particular,
design version of this transformer emits
dynamic mechanical models, were the
76.3 dB(A). This shows that low noise
breakthrough innovation to gain the
design cuts noise emission by 23.9 dB(A)
desired noise reduction. The figures be-
which is perceived four times as quiet
low show the impressive results achieved
asa standard design transformer by the
by Siemens low noise transformers.
human ear.

Standard transformer design


vs. low noise transformer design / 420 MVA / sound pressure
Condition Standard Low noise Noise
design design reduction
[dB(A)] [dB(A)] [dB(A)]
no-load 100% Urated 65.5 46.5 19.0
load current 100% Irated 70.3 51.1 19.2
cooler fans, pumps 74.5 39.2 35.3
TOTAL 76.3 52.4 23.9

Siemens low noise transformers references


Rated Sound pressure level Transformer type Year Units
power at full load produced
MVA [dB(A)]
100% Urated + 100% Irated

183 53.7 transformer 2013 6


234 49.1 autotransformer 20072009 6
2013
234 49.8 phase shifting transformer 2007 4 Published by and copyright 2014:
2010 Siemens AG
242 51.1 transformer 2009 5 Energy Sector
2011 Freyeslebenstrasse 1
300 53.4 transformer 2005 6 91058 Erlangen, Germany
2007
Siemens AG
2009
Energy Sector
2011
Power Transmission Division
300 53.7 phase shifting transformer 2013 2 Transformers
420 52.4 autotransformer 2005 6 Katzwanger Strasse 150
2010 90461 Nuremberg, Germany
500 55.2 autotransformer 2008 2 www.siemens.com/energy
575 58.9 phase shifting transformer 2006 1
Power Transmission Division
700 50.0 phase shifting transformer 2006 1 Printed in Germany
Note: For the human ear 56 dB(A) sound pressure level is comparable with a domestic refrigerator. Dispo 19200, c4bs No. 7480
Sound intensity measurement method is 24 dB(A) below sound pressure method. TH 101-140117 XX 472581 DB 0314X.X

siemens.com/energy/transformers