FFT test guide

FFT : Fast Fourier Transformation


From RAN13, we can do FFT test to check uplink interference with NodeB LMT.
Step 1 Run the MMLcommand LST RRU at selected NodeB and get the RRU cabinet
No, subtrack No and slot No.

Step 2 You can find FFT Frequecy Scan at Maintain Tab of NodeB LMT.

There are 3 models of FFT frequecy scan: High-resolution on-line frequency scan,
Broadband on-line frequency scan and Broadband off-line frequency scan. Mostly use
2017-3-11
High-resolution on-line frequency scan and Broadband on-line frequency scan.
High-resolution on-line frequency scan
Dont break down service.RBW should be set to 100KHz.

Broadband on-line frequency scan


Dont break down service.RBW should be set to 200KHz.

Broadband off-line frequency scan


Break down service. This will scan all uplink frequency which RRU support. First
deactivate cell. RBW should be set to 200KHz. After testing, activate cells.
Deactivate cells, Command :DEA UCELL: CellId=*;
Activate Cells, Command : ACT UCELL: CellId=*;