In the era of global telecommunication,we come to rely For Various purpose and conditions, the optical fiber
on light again as communication media. Optical fiber cables and designed fr buried in the ground and duct,
cable which opto-electronic is applied is a means of hung in air and laid down in the ocean.
transmitting in optical communication system.

This tinny thun glass fiber of approximately 10 mm in


Product Quality is Our Concern
diameter could carry more information across longer PT Voksel Electric Tbk commited product quality to be
distance than well-known metallic copper cable. For the primary manner of its all facets of the company,
special purpose, a very long distance could be covered Optical parameter is tested fr all optical fiber cables
with optical fibers without any repeater. covering incoming material, intermediate inspection
The glass fiber consists of core and jacket which are and final inspection by applying a high quality testing
made from very high grade pure silicon dioxide. Subject equipment and operated by well-trained operators
to this benefit, he fiber tensile strength s string and the in order t meet costumers requirement and our
liht iwl be dopped to provide specific internal refreactive commitment to ISO 9000 series of Quality Management
index. System.

Optical fiber cable become more popular also in


the subscriber network due to dynamic demand of
communication. They are not applicable only for
telephone, fax, acd television but hight speed computer
data will be as well transferred over data highways
across the entire universe.

PT. Voksel Electric Tbk, headquartered in Jakarta,


is one of the indonesias premier manufacturer
of the cables used by the power generation and
telecommunication industries. Since 1975 Voksel
benefited from an early alliance formed with Showa
Electric, Wire & Cable Co.Ltd. of Japan, through which
Voksel had technical assistance, as well, as support and aluminium wire rod essential for its production
fr it wn Researh and Development effrts. For futher of cables. Voksel commited to be the leading edge of
development, since 1989, that relationship became a Technology in yhe manufacturing and design of a wide
joint venture company. variety of the cables.

To take advantage of new marketing oppurtunities In present, Voksel has developed his product range by
and to maintain its competitive edge in a fast-growing manufacturing and designing optical fiber cables.
industrial sector. Voksel has vertically intergrated its
In recognition of the quality management standards
operations.
in place of its manufacturing plants at Cakung (North
The company manufacturers enameled wire, low Jakarta) and cileungsi (West Java). PT. Voksel Electric
voltage and medium voltage power cables and Tbk, was awarded ISO 9002 certification by SGS. Yarsley
telecommunication cables. It also manufactures copper International Certification Service Ltd. In 1995.
ADVANTAGES OF OPTICAL FIBER

Small Diameter Space Efficiency

Light Weight Easy Multi fiber


Cabling

Flexible
Easy Installation

Noise Immunity
Low Cross-Talk
Long Repeater
Span
Low Loss

Large Capacity
Wide Bandwidth Transmission Line

Long Haul & Metropolitan Network Local Access Network Premise Network
Regional Network

Cell
Site

CATV
OPTICAL FIBER CABLE THE CHARACTERISTIC OF OPTICAL FIBER CABLE

The number of fiber in a cable varies from 4 to 264 (more number of fibers are provided upon request). Optical fiber cables
will generally undergo 4 processes of production line such as Coloring Line, secondary Coating Line, SZ- stranding Line and Optical Fiber No. Color of Fiber Tube No. Color of Tube
Sheathing Line.
1 Blue 1 Blue
2 Orange 2 Orange
3 Green 3 Green
Coloring Production Line: SZ- Stranding Production line:
4 Brown 4 Brown
Fiber Coloring Process is carried out to mark the Stranding process which is around polyethelene
5 Grey 5 Grey
fiber. For easy identification of individual fiber inside coated central strength member applies SZ-
6 White 6 White
the tubes, they are color coded. The colors have no Stranding Method. The stranding is filled with jelly as
7 Red 7 Red
influence on the optical properties of the fibers. The Flooding Compound to fill any space of the cable to
8 Black 8 Black
fiber are colored using UV ink which are chosen as block the flow of water into the cable.
9 Yellow 9 Yellow
industry standard, easily in stripping, jointing and
Sheathing Production Line: 10 Violet 10 Violet
stability of optical loss under various stress.
Sheathing line is an unit which its process protects 11 Pink 11 Pink
Secondary Coating Production Line: the optical cable core from mechanical, thermal 12 Turquoise 12 Turquoise
This process uses Polybutylene Terepthalate (PBTP) and chemical effects, associated with storage,
as tube material which extremely has goos thermal, installation and operation. The core covering is Table 1. Color Scheme of Optical Fibers Table 2. Color Scheme of PBTP Tubes
hydrolysis and mechanical properties. The tubes covered with laminated Aluminium Polyethelene
contain fibers and are filled with special typical (LAP) sheath containing carbon black, to provide an
Table 3. Optical Characteristic of G.652D, G655C, G657A
gel. Secondary coating or tubing process is used electrical ground and moisture barrier. Sheathing also
to protect the optical fibers during cabling and uses one corrugated steel tape between inner and
Characteristic Value Unit
installation process. outer sheath to provide a mechanical protectin. The
Fiber Type Single Mode -
sheath is usually over printed t identify the type of
Mode Field Dia. At 1310 nm 9 to 10 10% m
cable of a particular point.
Mode Field Concentricity Error <1 m
Cladding Diameter 125 2 m
Cladding non Circularity <2 %
OPTICAL FIBER BASIC CABLE Coating Diameter 250 15 m

DESIGN DESIGN Maximum Attenuation at 1310 nm 0.4 dB/km


Maximum Attenuation at 1550 nm 0.3 dB/km
Core
Cladding (SiO2 + GeO2) 1 Maximum Chromatic dispersion at 1310 nm 3.5 Ps/(nm.Km)
(Acrylate) 2 Maximum Chromatic dispersion at 1550 nm 18 Ps/(nm.Km)
Cladding
3
(SiO2) Min. Bending Radius at full Tensile Strength 20 x cable OD -
4 Fibers per Tube 6 Fibers per Tube Maximum Cut Off Wavelength at 1310 nm (cc) 1260 nm
Zero Dispersion Wavelength (o) 1300 1324 nm
1. PBTP Tube
Zero Dispersion Slope (So) 0.095 Ps/(nm2.Km)
0.008-0.010 mm 2. Filling Gel
3. Colored Fiber
0.125 mm
12 Fibers per Tube 1 Fiber per Tube
0.250 mm Table 4. Environment condition

Each fiber is made of high purity Silica The cable core consists of stranded - six Now, There is cable core consists of
Item Value Unit
(SiO2) Glass doped with Germanium or eight thermal plastic elements with stranded - twelve thermal plastic
(GeO2) and fuse (SiO2) depressed a central strength member . Elements elements with a central strength Operating Temperature 10 - 50 C
cladding design for excellent geometrical could be either tubes, filler rods. member . Elements could be either Operating Relative Humidity 20 - 100 %
properties for splicing and micro bending tubes , filler rods, and Polybutylene Storage Tempertature 10 70 C
The coloured Polybutylene Teprepthalate
resistance. This fiber core is protected by Teprepthalate (PBTP) tube contains 1
(PBTP) tube contains 4,6, or 12 coloured Storage Relative Humidity 20-95 %
two layers of UV-cured acrylate coating fibers.
fibers with its configuration (table 1
which is strong and durable enough to
and 2) and water blocking compound to
stand up to the challenge such as; micro
prevent moisture/water penetration and
bending losses, abrasion resistance, etc
axial migration.
but remain easy to strip and splice.
OPTICAL FIBER CABLE TYPICAL SPECIFICATION
ADSS TYPE
Number of Fiber
Item
4 - 16 6 - 36 24 - 72 60 96
Loose Tube Number 6 6 6 8
This is optical cable ADSS type (All Fiber Type G652 A ~ D
Fiber Number per Lose Tube 4 6 12 12
Dielectric Self Supporting) with Aramid G653 A & B
Max.Tube OD (mm) 2.2 2.5 3.5 3.5
Yarn for peripheral strength member. G654 A ~ C
This cable must have non-metalic and G655 A ~ E Max.Cable outer Diameter (mm) 13.6 14.5 17.5 19.5

high tensile strength. They are used


as Aerial Application, anti rodent, anti Cable Size 4 ~ 264 Cores
Loose Tube Number
ballistic, anti termite cable whenever Fiber Count
1 2 3 4 5 6
mechanical strength, anti electrical Standard ITU-T G Series
induction and lighting effect. IEC 60793/IEC 60794 4 4 Filler Filler Filler Filler Filler

IEC 60304 6 6 Filler Filler Filler Filler Filler


For Aerial Installation, IEC 60587 12 4 4 Filler Filler 4 Filler
Dry Core Technology Telecordia GR-20 12 6 Filler Filler 6 Filler Filler
(All Dielectric Self Supporting)
16 4 4 Filler 4 4 Filler
18 6 6 Filler Filler 6 Filler
24 6 6 Filler 6 6 Filler
24 12 Filler Filler 12 Filler Filler
36 6 6 6 6 6 6
36 12 12 Filler Filler 12 Filler
48 12 12 Filler 12 12 Filler
60 12 12 12 12 12 Filler
72 12 12 12 12 12 12

Loose Tube Number


Fiber Count
1 2 3 4 5 6 7 8

1
2
3
4
1. HDPE Anti Tracking sheath
5 2. Water Blocking Tape
Number of Fiber
3. Peripheral strength member (Aramid Yarn) Property Unit
1 - 16 18 - 36 48 60 - 72 84-96
4. Filler Rod
5. Non Metalic Central Strength Member Tensile Strength > 12.000 > 12.000 > 12.000 > 12.000 > 12.000 N
(GRP + PE coated) Crush Resistance 2 2 2 2 2 KN/100mm
6
6. Ripcord Max. Weight 172 235 240 292 298 Kg/km
7. Water Blocking Yarn Min. Bending mm
8. Single mode color code optical fiber Proof Test > 0.5 % Filler 4 4 Filler
9. Gel filed PBTP color coded tube
Additional Loss < 0.1 dB Filler Filler 6 Filler
Radius 30 mm Filler 6 6 Filler
Number of Turn 100 - Filler 12 Filler Filler
7
8
9 Property Value Unit

Proof Test > 0.5 %


Additional Loss < 0.1 dB
Radius 30 mm
Number of Turn 100 -
OPTICAL FIBER CABLE TYPICAL SPECIFICATION
FOR AERIAL INSTALLATION

Number of Fiber
Non Metallic This is optical fiber cable intregated Item
Central Strength 4 - 16 6 - 36 24 - 72 60 96
Member
with a messenger wire for aerial
Loose Tubes Number 6 6 6 8
installation. This cable is loose tube
Central Strength Fiber Number per Loose Tube 4 6 12 12
Member Jacket
core. If armouring is necessary to
Optical Fiber
prevent damage by rodents, insects, Max.Tube OD (mm) 2.2 2.5 3.5 3.5
Filler Rod
and shot guns, a peripheral high Max. Cable Outer Diameter (mm) 13.5 17.5 17.5 17.5
Loose Tube
strength yarn can applied.

Loose Tube Number


Fiber Count
Aramid Yarn for Binder
Fiber Type G652 A ~ D 1 2 3 4 5 6

Water Blocking Tape


G653 A & B 4 4 Filler Filler Filler Filler Filler
G654 A ~ C 6 6 Filler Filler Filler Filler Filler
G655 A ~ E
Aluminium Tape 8 4 Filler Filler 4 Filler Filler

Aramid Yarn 12 4 4 Filler Filler 4 Filler


for Ripcord
Cable Size 4 ~ 264 Cores
Messenger Wire 12 6 Filler Filler 6 Filler Filler
16 4 4 Filler 4 4 Filler
Standard ITU-T G Series
IEC 60793/IEC 60794 18 6 6 Filler Filler 6 Filler

IEC 60304 24 6 6 Filler 6 6 Filler


STEL K-017-2008 ver. 2.0 24 12 Filler Filler 12 Filler Filler
36 6 6 6 6 6 6
36 12 12 Filler Filler 12 Filler
Outer Sheath 48 12 12 Filler 12 12 Filler
60 12 12 12 12 12 Filler
72 12 12 12 12 12 12

Loose Tube Number


Fiber Count
1 2 3 4 5 6 7 8
1
60 12 12 Filler Filler 12 12 12 Filler
2
72 12 12 12 Filler 12 12 12 Filler

84 12 12 12 12 12 12 12 Filler
1. HDPE sheath 96 12 12 12 12 12 12 12 12
2. Steel wire messenger
3
3. Laminated Aluminum Polyethylene type Mechanical Characteristic
4
4. Water Blocking Tape
Number of Fiber
5 5. Peripheral strength member (Aramid Yarn). Property Unit
6. Non Metalic Central Strength Member 1 - 16 18 - 36 48 60 - 72 84-96

(GRP + PE coated) Tensile Strength > 2700 > 2700 > 2700 > 2700 > 2700 N
6
7. Ripcord Crush Resistance 2 2 2 2 2 KN/100mm
8. Filler Rod Max. Weight 228 228 228 228 228 Kg/Km
9. Single mode color code optical fiber Min. Bending 225 270 300 300 300 mm
7 10. Gel filed PBTP color coded tube
8
Characteristic Value Unit
9
Proof Test 1 %
10
Additional Loss < 0.1 dB
Radius 30 mm
Number of Turn 100 -
OPTICAL FIBER FOR TYPICAL SPECIFICATION
DIRECT BURIED INSTALLATION

Number of Fiber
This is optical fiber cable a corrugated Fiber Type G652 A ~ D Item
4 - 16 6 - 36 24 - 72 60 96
steel tape or steel wire armoring for G653 A & B
Loose Tubes Number 6 6 6 8
protection. They are used as direct G654 A ~ C
buried, anti ballistic, anti rodent, anti G655 A ~ E Fiber Number per Loose Tube 4 6 12 12

termite cables whenever mechanical Max.Tube OD (mm) 2.2 2.5 3.5 3.5
strength is required. This cable is loose Cable Size 4 ~ 264 Cores Max. Cable Outer Diameter (mm) 18.2 22.2 22.2 22.2
tube core.
Standard ITU-T G Series
For Direct Buried Installation Loose Tube Number
IEC 60793/IEC 60794 Fiber Count
IEC 60304 1 2 3 4 5 6
STEL K-016-2008 ver. 2.0 4 4 Filler Filler Filler Filler Filler
6 6 Filler Filler Filler Filler Filler

12 4 4 Filler Filler 4 Filler


12 6 Filler Filler 6 Filler Filler
16 4 4 Filler 4 4 Filler
18 6 6 Filler Filler 6 Filler
24 6 6 Filler 6 6 Filler
24 12 Filler Filler 12 Filler Filler
36 6 6 6 6 6 6
36 12 12 Filler Filler 12 Filler
48 12 12 Filler 12 12 Filler
60 12 12 12 12 12 Filler
72 12 12 12 12 12 12
72 12 12 12 12 12 12

Loose Tube Number


Fiber Count
1 1 2 3 4 5 6 7 8
2 60 12 12 Filler Filler 12 12 12 Filler
3
72 12 12 12 Filler 12 12 12 Filler
4 1. HDPE sheath
84 12 12 12 12 12 12 12 Filler
2. Corrugated Steel Tape Armor
5 96 12 12 12 12 12 12 12 12
3. MDPE inner sheath
4. Laminated Aluminum Polyethylene type
Mechanical Characteristic
5. Non metalic central strength member (GRP+PE coated)
6 Number of Fiber
6. Water Blocking Tape
7 Property Unit
7. Ripcord 1 - 16 18 - 36 48 60 - 72 84-96
8 8. Peripheral strength member (Aramid Yarn). Tensile Strength > 2700 > 2700 > 2700 > 2700 > 2700 N
9. Filler Rod Crush Resistance 4.5 4.5 4.5 4.5 4.5 KN/100mm
10. Gel filed PBTP color coded tube
Max. Weight 326 446 467 471 473 Kg/Km
9 11. Single mode color code optical fiber
Min. Bending 250 270 300 300 300 mm

10
Characteristic Value Unit
11
Proof Test 0.5 %
Additional Loss < 0.1 dB
Radius 30 mm
Number of Turn 100 -
OPTICAL FIBER CABLE FOR TYPICAL SPECIFICATION
DROP WIRE INSTALLATION

Type Specification Drop Aerial Cable


Number of Fiber
Item
Drop cable being made to accommodate FTTH system telecommunication 1 2 4
industry as for wiring from terrestrial to Ethernet system. Designed to short
Max. Cable Height (mm) 5 5.5 5 5.5 1.2
distance span with easy connection from end user to nearby fiber access
Max. Cable Width (mm) 2 - 2.5 2 - 2.5 12.5
terminal. This cable consist of 1 up to 4 fiber core with to FRP in both inside to
avoid shrieked in its cable jacketing. There are two kinds cable (Aerial and Burial)
Type Specification Single Drop Burial Cable
Number of Fiber
Item
1 2 4
Construction DROP Aerial Cable Max. Cable Height (mm) 3 - 3.5 3 - 3.5 3 - 3.5
Max. Cable Width (mm) 2 - 2.5 2 - 2.5 12.5
1
2
Mechanical Characteristic
3
Number of Fiber
Fiber Count Unit
1 2 4
Tensile Strength > 130 > 130 > 130 N

4 Crush Resistance 0.3 0.3 0.3 kg


2012 VOKSEL KABEL OPTIK/G657A /DW 2F

Max. Weight 10 10 38 Kg/Km


Min. Bending 20 X OD 20 X OD 20 X OD mm

Characteristic Value Unit


5
Proof Test 1 %
1. Steel Wire Messenger Additional Loss < 0.1 dB
2. PBT Loose Tube
Radius 15 mm
3. Optical Fiber
4. PE Sheath
5. GRP Strength Member

Construction DROP burial Cable

3
4

1
2012 VOKSEL KABEL OPTIK/G657A /DW 2F

1. PE Sheath
2. GRP Strength Member
3. PBT Loose Tube
4. Optical Fiber
OPTICAL FIBER FOR TYPICAL SPECIFICATION
DUCT INSTALLATION
Number of Fiber
Item
4 - 16 6 - 36 24 - 72 60 96

This is optical fiber cable is with loose Fiber Type G652 A ~ D Loose Tubes Number 6 6 6 8

tube core. It is quite suitable to the G653 A & B Fiber Number per Loose Tube 4 6 12 12
system requiring more optical fibers. G654 A ~ C Max.Tube OD (mm) 2.2 2.5 3.5 3.5
The fibers are accommodated in jelly G655 A ~ E Max. Cable Outer Diameter (mm) 13.5 17.5 17.5 17.5
filled tubes with an excess length.
If a flame retardant characteristic is Cable Size 4 ~ 264 Cores
Loose Tube Number
required, a special material can be Fiber Count
applied as the outer sheath. Standard ITU-T G Series 1 2 3 4 5 6
IEC 60793/IEC 60794 4 4 Filler Filler Filler Filler Filler
For Duct Installation IEC 60304 6 6 Filler Filler Filler Filler Filler
STEL K-016-2008 ver. 2.0 12 4 4 Filler Filler 4 Filler
12 6 Filler Filler 6 Filler Filler
16 4 4 Filler 4 4 Filler
18 6 6 Filler Filler 6 Filler
24 6 6 Filler 6 6 Filler
24 12 Filler Filler 12 Filler Filler
36 6 6 6 6 6 6
36 12 12 Filler Filler 12 Filler
48 12 12 Filler 12 12 Filler
60 12 12 12 12 12 Filler
72 12 12 12 12 12 12
72 12 12 12 12 12 12

Loose Tube Number


Fiber Count
1 2 3 4 5 6 7 8
60 12 12 Filler Filler 12 12 12 Filler
72 12 12 12 Filler 12 12 12 Filler

1 84 12 12 12 12 12 12 12 Filler
2 96 12 12 12 12 12 12 12 12
3
1. HDPE sheath
4 Mechanical Characteristic
2. Laminated Aluminum Polyethylene type
Number of Fiber
3. Water Blocking Tape Property Unit
4. Metalic/non metalic central strength member 1 - 16 18 - 36 48 60 - 72 84-96
5
5. Peripheral strength member (Aramid Yarn). Tensile strength > 2700 > 2700 > 2700 > 2700 > 2700 N
6 6. Ripcord Crush Resistance 2 2 2 2 2 KN/100mm
7. Filler Rod Max.Weight 172 273 275 278 281 Kg/Km
7
8. Flooding compound (Jelly) / non Jelly (dry cable type).
8 Min.Bending 250 270 300 300 300 mm
9. Gel filed PBTP color coded tube (No Load)
10. Single mode color code optical fiber Min.Bending 250 270 300 300 300 mm
(Under Load)

9
10
Characteristic Value Unit

Proof Test > 0.5 %


Additional Loss < 0.1 dB
Radius 30 mm
Number of Turn 100 -
OPTICAL FIBER CABLE TYPICAL SPECIFICATION
FOR AERIAL INSTALLATION
Type Specification Single Core Per Tube Aerial
Number of Fiber
Item
8 10 12 18 24
In fiber optic, Single Core Per Tube is one type of cable used to capture one or more Standard STEL QA K 036 2012
Specification (AERIAL) Loose Tubes Number 8 10 12 18 8
optical fiber for the FTTH (Fiber to The Home) Distribution cable. With design easier
to split the fiber core and connecting to termination box as well as the loose tube STEL QA K 037 2012 Fiber Number per Loose Tube 1 1 1 1 1

type is compatible in humidly temperature capacity 8 24 Core. There are two kind (DUCT) Max.Tube OD (mm) 1.2 1.2 1.2 1.2 1.2
type cable FTTH (Aerial Application Cable and Duct Application Cable) Max. Cable Outer Diameter (mm) 10.6 11.6 12.5 13.5 15

Type Specification Single Core Per Tube Duct


Construction Single Core Per Tube Aerial Cable Item
Number of Fiber

8 10 12 18 24
Loose Tubes Number 8 10 12 18 8
Non Metallic Fiber Number per Loose Tube 1 1 1 1 1
Central Strength
Member Messenger Wire Max.Tube OD (mm) 1.2 1.2 1.2 1.2 1.2
Optical Fiber
Max. Cable Outer Diameter (mm) 10.6 11.6 12.5 13.5 15
Aramid Yarn for Binder Central Strength
Loose Tube Member Jacket
Water Blocking Tape Black HDPE Sheath Jumlah Serat Optik
Filler Rod Nomor urut serat/ Tube 8 10 12 18 24
Moisture Barrier
Aluminium Tape Non Laminated Water Blocking Yarn Lapis 1 Lapis 1 Lapis 1 Lapis 1 Lapis 2 Lapis 1 Lapis 2
High Tensile Aramid Yarn 1 1 1 1 1 1 1 1
Messenger Wire Ripcord Aramid Yarn
2 1 1 1 1 1 1 1
High Tensile Aramid Yarn
Aramid Yarn Loose Tube 3 1 1 1 1 1 1 1
VOKSEL 2013 FIBER OPTIC / SM.D / A 24 / 24 T

for Ripcord 4 1 1 1 1 1 1 1
Optical Fiber
5 1 1 1 1 1 1 1
6 1 1 1 1 1 1 1
7 1 1 1 - 1 1 1
Outer Sheath
FRP with PE Coated 8 1 1 1 - 1 1 Filler
9 - 1 1 - 1 1 1
10 - - 1 - 1 - 1
11 - - 1 - 1 - 1

Construction Single Core Per Tube DUCT Cable 12 - - 1 - 1 - 1


13 - - - - - - 1
14 - - - - - - 1
15 - - - - - - 1
16 - - - - - - Filler

Mechanical Characteristic
Black HDPE Sheath
Number of Fiber
Moisture Barrier Fiber Count Unit
Non Laminated Water Blocking Yarn 8 10 12 18 24
High Tensile Aramid Yarn
Ripcord Aramid Yarn
Tensile strength > 2850 > 2850 > 2850 > 2850 > 2850 N
High Tensile Aramid Yarn Crush Resistant 2,2 2,2 2,2 2,2 2,2 KN/100mm
Loose Tube
Max. Weight 185 200 210 215 240 Kg/Km
Optical Fiber
Min. Bending 20 X OD 20 X OD 20 X OD 20 X OD 20 X OD mm
VOKSEL 2013 / FIBER OPTIC / SM.D / D 24 / 24 T

FRP with PE Coated Characteristic Value Unit

Proof Test 1 %
Additional Loss < 0.1 dB
Radius 30 mm
Number of Turn 100 -
JUMPER DROP
WIRE WIRE

Poly Vinyl Chloride insulated Jumper Jumper Wire Dimensions Aerial Drop wires are designed for Drop Wire Dimensions
Wires are designed for cross connecting installations, from distribution cables
Conductor mm 0.6 Conductor mm 0.6 0.8
of jumping usage, on MDF,IDF, and to subcribers or for installations on
Diameter Diameter
other connecting circuit in cable house. external wall of buildings or houses
Cable Size Pair 1
Cable Size Pair 1 1
PVC Insulations mm 0.3
Type of Product Jumper Wire Thickness Type of Product Drop Wire PE Insulation mm 1.0 1.0
Cable Size 2 x 1 x 0.6 Cable Size 2 x 1 x 0.6 Thickness
External mm 2.4
2 x 1 x 0.5 Diameter 2 x 1 x 0.8 Cable Width mm 5.9 5.9
Ref. Standard STEEL K-006 Cable Weight kg/km 8 Ref. Standard STEEL K-004
Suspension mm 1/1.2 1/1.2
SII 0616-82 Standard Packing m 500 SII 064-82 Strand
SNI 04-2068-1990 Length SNI 04-2066-1990
Cable Weight kg/km 31 36
Cable R-V Drum Volume m3 - Cable U - ES
Designation Drum Type Coil Designation Standard m 500 500
Packing Length

Drum Volume m3 - -

DESCRIPTION UNIT SPECIFICATION Drum Type Coil Coil

ELECTRICAL AND MECHANICAL DATA :


Conductor resistance at 20 1C DESCRIPTION UNIT SPECIFICATION
Maximum Individual Ohm/km 65.00
Min. Insulation resistance at 5000 V DC M Ohm.km/minute 100 ELECTRICAL AND MECHANICAL DATA :
Conductor resistance at 20 1C
MECHANICAL CHARACTERISTICS : Maximum Individual Ohm/km 65.00
Min. Elongation of copper conductor % 18 Min. Insulation resistance at 5000 V DC M Ohm.km/minute 10,000
Min. Tensile Strength of PVC insulation N/mm 12.5
Min.Elongation of PVC insulation % 12.5
MECHANICAL CHARACTERISTICS :
Min. Elongation of copper conductor % 18
Min. Tensile Strength of PVC insulation N/mm 1255
Cable Construction Min.Elongation of PVC insulation % 300

PVC Insulation

Copper Conductor Galvanised Steel Wire


(GSW)
PVC Insulation
Single Core Steel Wire
(Copper) (1 x 1.2 mm)
Installation Colour
PE Sheath
Colour of Insulation (Black)
Pair Number
A Wire B Wire Black PE
1 White Blue Sheath

2 White Red
Single Core
(Copper) Copper Conductor
3 White Black Cable
Marking (2 x 0.6 mm)
4 Blue Red
PT. VOKSEL ELECTRIC Tbk.

EXECUTIVE OFFICE Menara Karya 3rd Fl. Suite D Jl. HR. Rasuna Said Block X-5 Kav 1-2 Jakarta 12950 Indonesia
Ph. +62 21 5794 4622 Fx. +62 21 5794 4649

FACTORY &  Jl. Raya Narogong Km 16 Cileungsi Bogor 16820 Indonesia


OPERATIONAL Ph. +62 21 823 0525 +62 21 8249 1720 +62 21 8249 1712 Fx. +62 21 823 0526 +62 21 8249 1701
OFFICE Hotline: + 62 21 8249 3329 E-mail: ve@voksel.co.id sales@voksel.co.id

You might also like