Professional Documents
Culture Documents
CVEN9806 Major Assignment - 2016
CVEN9806 Major Assignment - 2016
CVEN9806 Major Assignment - 2016
1. Design the prestressing using 12.7 strands and provide a structural working drawing for the hollow core
slab section.
2. Give a graphical representation of the stresses at transfer and service load through the span (every 0.5m)
showing the stress limits on the diagram.
3. Estimate the losses including the elastic shortening losses through the span (every 0.5m) and show these
on a chart.
4. Give a graphical representation of the stresses (take account of the losses estimated in section 3 above),
at both transfer and service load through the span (every 0.5m) showing the stress limits on the diagram.
5. Calculate the flexural strength capacity at transfer and under full loads (take account of the losses
estimated in section 3 above), through the span (every 0.5m) and show these on a chart along with the
design ulitmate moment due to the factored loads. Check the ductility through the span.
6. Calculate the shear strength capacity at transfer and under full loads (take account of the losses
estimated in section 3 above), through the span (every 0.5m) and show these on a chart along with the
design ulitmate shear due to the factored loads.
7. Calculate the deflection (take account of the losses estimated in section 3 above), through the span
(every 0.5m) and show these on a chart along with the design ulitmate shear due to the factored loads.
8. Calculate the transfer strength capacity (take account of the losses estimated in section 3 above), through
the span (every 0.5m) and show these on a chart along with the design ulitmate transfer loaidng due to
the factored loads.
The assessment will depend on the thoroughness, clarity, presentation and quality of the design and especially
the merit of the working drawings. The assignment should be undertaken in groups of no more than three
people.
The Final Submission is due on Tuesday 24th May Week 12.
To be Completed in Groups of 3
1
15
35 32.5
155 205
25 10
1200
Data
fp = 1870 MPa; Ap of strand=98.6 mm2; Strand dia. 12.7 mm;
Cover to Strands 35 mm
fci = 40 MPa; fc = 50 MPa;
Eci = 31975 MPa;
kcs=2.5; s 0.7; L 0.4;
Initial Estimate of Losses at Transfer approx. 8%
Initial Estimate of Service Losses approx. 10%
Live Load 3.5 kPa
SuperImposed Dead Load 0.5 kPa