Professional Documents
Culture Documents
Access: Sheet 1: No Parameter Description
Access: Sheet 1: No Parameter Description
No parameter description
SET USTATETIMER:
5000 10000
RBSETUPRSPTMR=15000;
MOD
40 70 UCELLRLACTTIME:CELLID=XXXXX,
MIDRATERLACTTIMEDEFOFFVAL=70;
MOD UCELLALGOSWITCH:
CellId=*****,
NBMDlCacAlgoSelSwitch=ALGORITH
ALGORITHM_FIRST ALGORITHM_THIRD
M_THIRD,
NBMLdcAlgoSwitch=UL_UU_LDR-
1&DL_UU_LDR-1&DL_UU_OLC-1;
MOD UCELLALGOSWITCH:
CellId=*****,
&DL_UU_LDR-0&DL_UU_OLC- NBMDlCacAlgoSelSwitch=ALGORITH
DL_UU_LDR-1&DL_UU_OLC-1
0 M_THIRD,
NBMLdcAlgoSwitch=UL_UU_LDR-
1&DL_UU_LDR-1&DL_UU_OLC-1;
MOD UCELLCAC: CellId=*****,
DlConvAMRThd=80 DlConvAMRThd=85
DlConvAMRThd=85,
DlConvNonAMRThd=85 DlConvNonAMRThd=85
DlConvNonAMRThd=85,
DlOtherThd=75 DlHOThd=85 DlOtherThd=80 DlHOThd=90
DlOtherThd=80, DlHOThd=90,
DlCellTotalThd=90 DlCellTotalThd=95
DlCellTotalThd=95;
VS.RRC.Rej.DLCE.Cong
CELL wise, for easing CE
VS.RAB.FailEstabCS.DLCE.Cong
congestion
VS.RAB.FailEstabPS.DLCE.Cong
Sheet 2: MOBILITY
No parameter
InterRATCSThd2DEcN0 InterRATCSThd2FEcN0
1
InterRATCSThd2DRSCP InterRATCSThd2FRSCP
InterRATCSThd2DEcN0 InterRATCSThd2FEcN0
2
InterRATCSThd2DRSCP InterRATCSThd2FRSCP
3 CIOOffset
4 InterRATNCovHOCSThd
description
For coverage-based inter-RAT handovers,Coverage-based
handovers are triggered by the event 2D or event 2F
Add Cell-Oriented coverage-based inter-RAT handover
measurement algorithm parameters.Coverage-based handovers
are triggered by the event 2D or event 2F
This parameter is used for decision making for the inter-RAT
handover. The larger the value of the parameter, the higher the
handover priority of the GSM cell. The smaller the value of the
parameter, the lower the handover priority of the GSM cell.
This parameter is used to set measurement control on the
event 3C. The event 3C is triggered when the signal quality of
the target frequency is above this threshold.
default value
InterRATCSThd2DEcN0=-14 InterRATCSThd2FEcN0=-12
InterRATCSThd2DRSCP=-100 InterRATCSThd2FRSCP=-97
InterRATCSThd2DEcN0=-14 InterRATCSThd2FEcN0=-12
InterRATCSThd2DRSCP=-100 InterRATCSThd2FRSCP=-97
21
recommend value
InterRATCSThd2DEcN0=-12 InterRATCSThd2FEcN0=-10
InterRATCSThd2DRSCP=-98 InterRATCSThd2FRSCP=-95
InterRATCSThd2DEcN0=-12 InterRATCSThd2FEcN0=-10
InterRATCSThd2DRSCP=-98 InterRATCSThd2FRSCP=-95
-3
16
MML command
SET UINTERRATHOCOV: InterRATCSThd2DEcN0=-12,
InterRATCSThd2FEcN0=-10, InterRATCSThd2DRSCP=-98,
InterRATCSThd2FRSCP=-95;
MOD UCELLINTERRATHOCOV: CellId=*****,
InterRATCSThd2DEcN0=-12, InterRATCSThd2FEcN0=-10,
InterRATCSThd2DRSCP=-98, InterRATCSThd2FRSCP=-95;
VS.IRATHO.AttRelocPrepOutCS.GCell
VS.IRATHO.SuccRelocPrepOutCS.GCell
VS.IRATHO.AttOutCS.GCell VS.IRATHO.SuccOutCS.GCell
VS.IRATHO.AttRelocPrepOutCS.Service
VS.IRATHO.SuccRelocPrepOutCS.Service
VS.IRATHO.SuccOutCS.Service
Sheet 3: Call Drop
MOD UCELLRLPWR:
CNDomainId=CS_DOMAIN,
30 MaxBitRate=12200, CELL wise
RlMaxDlPwr=30, RlMinDlPwr=-
120;
MOD UCELLRLPWR:
CNDomainId=CS_DOMAIN,
-120 MaxBitRate=12200, CELL wise
RlMaxDlPwr=30, RlMinDlPwr=-
120;
relative KPI/cluonter monitor
after implement
VS.CS.AMR.Call.Drop.Cell.Rate
VS.RAB.AbnormRel.CS.RF
VS.CS.AMR.Call.Drop.Cell.Rate
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF.ULSync
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF.ULSync
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF.ULSync
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF.UuNoRe
ply
VS.RAB.AbnormRel.CS.RF
VS.RAB.AbnormRel.CS.RF.UuNoRe
ply