Conduit Legend: Sydney Light Rail

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

1 2 3 4 5 6 7 8 9 10 11 12

CONDUIT LEGEND
TOWN HALL RAWSON PLACE FOOTPATHS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED
AT 250mm BELOW PAVING
A ROADS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED AT A
400mm BELOW PAVING.

FOOTHPATHS: 3x80 HD uPVC ORANGE POWER CONDUIT BURRIED AT


600mm BELOW PAVING.
ROADS: 3 X 80 HD uPVC ORANGE POWER CONDUIT BURRIED AT
750mm BELOW PAVING.

NOTE: REFER TO CoS GENERAL CONDUITS IN FOOTWAY AND


CARRIAGEWAY DWG No: 5.1.1 FOR TYPICAL TRENCH DETAIL.

CoS APPROVED ELECTRICAL CONDUIT JUNCTION PIT REFER TO CoS


GENERAL LIGHTING PIT ARRANGEMENT DWG No: 5.1.6

PITS WITHIN FOOTPATH (MINIMUM CLASS C LID)


B L 715 B

WILMOT
W 580 *NOTE PIT WIDTH INCREASED TO SUIT CONDUITS.

JOINS DRG SLR-DJV-D40-ELE-DWG-042202


D 800
BATHURST

3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT

STREET
3x80 HD uPVC ORANGE POWER CONDUIT
PITS WITHIN ROAD OR ROAD CROSSINGS (MINIMUM CLASS D LID)

STREET
L 1395
W 580

CENTRAL
D 1000
STREET

ELECTRICAL LEGEND
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT 3x80 HD uPVC ORANGE POWER CONDUIT CoS STREETLIGHTING DISTRIBUTION BOARD
REFER TO CoS DRAWING 5.13 REV C.
7.0 m
CIRCUIT DESIGNATION CoS-MSB-XX-XX-X
C ASSET NUMBERS
C
11km600

11km700
AUSGRID ASSET MUMBER SY-xxxxx
CoS ASSET NUMBER SP-xxxxx
8.9 m

620

640
SLR PROPOSED ASSET NUMBER SLR-ZCS-SPxxx

660
9.2 m

680
CoS ELECTRICAL PIT. REFER TO CoS DRAWINGS 5.1.5 REV C.
AND 5.1.6 REV C. FOR DETAILS.

720
14.4 m RMS TRAFFIC CONTROLLER CABINET
21.9 m
19.1 m
11.1 m
CIVIL LEGEND
(SOUTH)
C (NORTH)

21.7 m
15.9 m
6.4 m

22.8 m

GEORGE STREET SOUTHBOUND GENERAL


PROJECT SITE BOUNDARY
E C
E

D D
N

SURVEY
N
O
O
Z
Z

TRACK
S
S
K
K

PROPOSED LIGHT RAIL ALIGNMENT


R
R

LIMIT OF WO

REFER TO DESIGN PACKAGE DP05.2


LIMIT OF WO

GEORGE STREET NORTHBOUND PROPOSED CSELR STOP


REFER TO DESIGN PACKAGE DP01.2
20.7 m 19.2 m
14.2 m
10km000 LIGHT RAIL MAJOR KILOMETERAGE (CHAINAGE)
10.8 m 2.2 m
5.9 m
OCS REFER TO DESIGN PACKAGE DP23 FOR FINAL DESIGN

2.6
13.2 m

m
4.6 m
21.7 m
640

2.9 m
620

TRAFFIC SIGNALS - REFERENCE ONLY

660

680

11km700
11km600

8.4 m

720
10.5 m TRAFFIC CONTROL SIGNAL WITH OVERHANG
5.6 m

TRAFFIC CONTROL SIGNAL


E 11.4 m E
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT
REFERENCE DRAWINGS
BATHURST S

3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT


3x80 HD uPVC ORANGE POWER CONDUIT 1. FOR PROPOSED SMARTPOLE SCHEDULE REFER TO DRAWING
SLR-DJV-D40-ELE-DWG-042233 & 042234.
2. FOR CoS STREET LV LIGHTING CIRCUITS REFER TO DRAWING
SLR-DJV-D40-ELE-DWG-042235.
TREET

3. REFER TO POLE MANUFACTURERS DETAILS ABOUT POLE


3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT TERMINATION FOR EACH SPECIFIC SERVICE.
3x80 HD uPVC ORANGE POWER CONDUIT 4. FOR SLR EQUIPMENT REFER TO SMARTPOLE EQUIPMENT SCHEDULE
SLR-DJV-D40-OCS-DWG-062231
F 5. FOUNDATION PLANS F
SLR-DJV-D40-OCS-DWG-062201 TO 062208
NOTES 6. CONDUIT DETAILS
SLR-DJV-D40-OCS-DWG-062706
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH THE CoS SYDNEY STREETS

CAMPBELL STREET
GOULBURN STREET

HAY STREET
LIVERPOOL STREET
TECHNICAL SPECIFICATION B8. STREET LIGHTING AND DP04.2 ROAD WORKS TOWN HALL RAWSON PLACE

CENTRAL STREET
ET

VE
DRAWINGS AND ZONE CS DESIGN REPORT SLR-DJV-D40-ROD-REP-042001.

BATHURST ST

CITY TUNNEL
WILMOT STRE

YA
2. DESIGN BASED ON SURVEY MODEL CORR-SLR-AIA-MIO-000-CORR-004941-

EDD
PITT STREET

CROSS
20160822a_TOPO_Survey.12da.
3. THESE DRAWINGS DO NOT SHOW THE EXISTING AUSGRID LV STREET LIGHTING
SUPPLY RETICULATION. REFER TO DESIGN PACKAGE DP17 FOR LEVEL 3 DESIGN GEORGE
AND WILL BE MANAGED DURING CONSTRUCTION WITH AUSGRID AND ASP 1 GEORGE STREET
CONTRACTOR. STREET

4. REFER TO STRUCTURAL DESIGN DRAWINGS FOR SMARTPOLE FOUNDATION AND

ALBION PLACE

ULTIMO ROAD
G CONDUIT COORDINATION.
5. UPVC NEW DUCTS ARE TO BE INSTALLED AS SHOWN ON THE DRAWINGS ONCE
G
THE COS HAVE GIVEN APPROVAL. KEY PLAN
6. CONDUITS SHALL BE LAID ALONG THE ROUTE IN THE POSITIONS AND AT THE
DEPTHS DOCUMENTED BY THE CoS SPECIFICATION AND ON THE DRAWINGS. THE
FINAL POSITION AND DEPTH OF THE DUCTS MAY BE CHANGED ON SITE WITH THE Issued for Construction
STREET LIGHTING PLAN APPROVAL OF THE CoS TO AVOID OBSTRUCTIONS.
Sydtrac CCB ref:
SCALE 1 : 250
DRAWING COLOUR CODED - PRINT ALL COPIES IN COLOUR SLR-D&C-D10-000-CCB-000146
SYDNEY LIGHT RAIL
This drawing and the information contained thereon have been created solely for a particular purpose and client.
CONSTRUCTOR DESIGNER CLIENT Transport for NSW and it's Consultants provide no warranty and accept no liability, arising from the use of this drawing
and the information shown thereon for any other purpose. This is protected by copyright. You may not reproduce any
of it in any form without the written permission of Transport for NSW. If you do, you may have to pay damages to
Transport for NSW or you may be prosecuted.

DRAWN P.HELLAWELL 07.03.17 ROADWORKS


J.SAWRAS 07.03.17 TOWN HALL TO RAWSON PLACE
DESIGNED
STREETLIGHTING CONDUIT PLAN - SHEET 1
DRG CHECK D.SMITH 07.03.17 FILE No. 1 OF 8
A PSH 07.03.17 IFC RC
REV BY DATE DESCRIPTION APPD DESIGN CHECK J.YAPP 07.03.17 STATUS IFC C
DRG No. EDMS No.
A1 Original Co-ordinate System: MGA Zone 56 Height Datum: A.H.D. Scale: As indicated 19.3 m APPROVED R.CASIMIR 07.03.17 SLR-DJV-D40-ELE-DWG-042301 A

1 2 3 4 5 6 7 8 9 10 11 12
Plot Date & Time: 7/03/2017 3:36:27 PM
1 2 3 4 5 6 7 8 9 10 11 12

TOWN HALL RAWSON PLACE


CONDUIT LEGEND
FOOTPATHS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED
A AT 250mm BELOW PAVING A
ROADS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED AT
400mm BELOW PAVING.

FOOTHPATHS: 3x80 HD uPVC ORANGE POWER CONDUIT BURRIED AT


600mm BELOW PAVING.
ROADS: 3 X 80 HD uPVC ORANGE POWER CONDUIT BURRIED AT
750mm BELOW PAVING.

NOTE: REFER TO CoS GENERAL CONDUITS IN FOOTWAY AND


CARRIAGEWAY DWG No: 5.1.1 FOR TYPICAL TRENCH DETAIL.

CoS APPROVED ELECTRICAL CONDUIT JUNCTION PIT REFER TO CoS


3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
GENERAL LIGHTING PIT ARRANGEMENT DWG No: 5.1.6
3x80 HD uPVC ORANGE POWER CONDUIT

B B

JOINS DRG SLR-DJV-D40-ELE-DWG-042203


PITS WITHIN FOOTPATH (MINIMUM CLASS C LID)
L 715
NOTE 5
W 580 *NOTE PIT WIDTH INCREASED TO SUIT CONDUITS.
DWG-042201

D 800

PITS WITHIN ROAD OR ROAD CROSSINGS (MINIMUM CLASS D LID)

REET
L 1395
T
STREE

W 580
JOINS DRG SLR-DJV-D40-ELE-

D 1000

LIVERPOOL ST
CoS-MSB-5 ELECTRICAL LEGEND
RAL
CENT

CoS STREETLIGHTING DISTRIBUTION BOARD


REFER TO CoS DRAWING 5.13 REV C.

6.2 m
CIRCUIT DESIGNATION CoS-MSB-XX-XX-X
C 10.5 m
ASSET NUMBERS C

2.3 m
AUSGRID ASSET MUMBER SY-xxxxx
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT CoS ASSET NUMBER SP-xxxxx
SLR PROPOSED ASSET NUMBER SLR-ZCS-SPxxx

11km800
3x80 HD uPVC ORANGE POWER CONDUIT

m
2.6
CoS ELECTRICAL PIT. REFER TO CoS DRAWINGS 5.1.5 REV C.
AND 5.1.6 REV C. FOR DETAILS.
720

12.0 m

860
RMS TRAFFIC CONTROLLER CABINET

840
740

820
780
760

8.8 m
19.4 m 24.4 m 9.0 m
CIVIL LEGEND
6.4 m 5.8 m 15.2 m 9.0 m 6.0 m 26.2 m
13.9 m
GENERAL
PROJECT SITE BOUNDARY
D GEORGE STREET SOUTHBOUND D

6.9 m
SURVEY
TRACK
PROPOSED LIGHT RAIL ALIGNMENT
REFER TO DESIGN PACKAGE DP05.2
PROPOSED CSELR STOP
REFER TO DESIGN PACKAGE DP01.2

8.6 m
GEORGE STREET NORTHBOUND 10km000 LIGHT RAIL MAJOR KILOMETERAGE (CHAINAGE)
21.2 m 25.3 m 24.4 m
20.7 m
2.4
m 1.2 m 9.9 m
2.2 m
1.8 m
OCS REFER TO DESIGN PACKAGE DP23 FOR FINAL DESIGN
26.0 m

TRAFFIC SIGNALS - REFERENCE ONLY

3.9 m
720

860
TRAFFIC CONTROL SIGNAL WITH OVERHANG
740

840
820
11km800
780
760

E TRAFFIC CONTROL SIGNAL E


3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT
REFERENCE DRAWINGS

REET
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT 3x80 HD uPVC ORANGE POWER CONDUIT 3x80 HD uPVC ORANGE POWER CONDUIT 1. FOR PROPOSED SMARTPOLE SCHEDULE REFER TO DRAWING

LIVERPOOL ST
SLR-DJV-D40-ELE-DWG-042233 & 042234.
2. FOR CoS STREET LV LIGHTING CIRCUITS REFER TO DRAWING
SLR-DJV-D40-ELE-DWG-042235.
3. REFER TO POLE MANUFACTURERS DETAILS ABOUT POLE
TERMINATION FOR EACH SPECIFIC SERVICE.
4. FOR SLR EQUIPMENT REFER TO SMARTPOLE EQUIPMENT SCHEDULE
SLR-DJV-D40-OCS-DWG-062231
F 5. FOUNDATION PLANS F
SLR-DJV-D40-OCS-DWG-062201 TO 062208
6. CONDUIT DETAILS
SLR-DJV-D40-OCS-DWG-062706

CAMPBELL STREET
GOULBURN STREET

HAY STREET
LIVERPOOL STREET
TOWN HALL RAWSON PLACE

CENTRAL STREET
ET

VE
BATHURST ST

CITY TUNNEL
WILMOT STRE

YA
EDD
PITT STREET

CROSS
GEORGE
GEORGE STREET
STREET

G G

ALBION PLACE

ULTIMO ROAD
KEY PLAN
STREET LIGHTING PLAN Issued for Construction
SCALE 1 : 250
Sydtrac CCB ref:
DRAWING COLOUR CODED - PRINT ALL COPIES IN COLOUR SLR-D&C-D10-000-CCB-000146
SYDNEY LIGHT RAIL
This drawing and the information contained thereon have been created solely for a particular purpose and client.
CONSTRUCTOR DESIGNER CLIENT Transport for NSW and it's Consultants provide no warranty and accept no liability, arising from the use of this drawing
and the information shown thereon for any other purpose. This is protected by copyright. You may not reproduce any
of it in any form without the written permission of Transport for NSW. If you do, you may have to pay damages to
Transport for NSW or you may be prosecuted.

DRAWN P.HELLAWELL 07.03.17 ROADWORKS


J.SAWRAS 07.03.17 TOWN HALL TO RAWSON PLACE
DESIGNED
STREETLIGHTING CONDUIT PLAN - SHEET 2
DRG CHECK D.SMITH 07.03.17 FILE No. 2 OF 8
A PSH 07.03.17 IFC RC
REV BY DATE DESCRIPTION APPD DESIGN CHECK J.YAPP 07.03.17 STATUS IFC C
DRG No. EDMS No.
A1 Original Co-ordinate System: MGA Zone 56 Height Datum: A.H.D. Scale: N.T.S APPROVED R.CASIMIR 07.03.17 SLR-DJV-D40-ELE-DWG-042302 A

1 2 3 4 5 6 7 8 9 10 11 12
Plot Date & Time: 7/03/2017 3:37:04 PM
1 2 3 4 5 6 7 8 9 10 11 12

CONDUIT LEGEND
TOWN HALL RAWSON PLACE
FOOTPATHS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED
A AT 250mm BELOW PAVING A
ROADS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED AT
400mm BELOW PAVING.

FOOTHPATHS: 3x80 HD uPVC ORANGE POWER CONDUIT BURRIED AT


600mm BELOW PAVING.
ROADS: 3 X 80 HD uPVC ORANGE POWER CONDUIT BURRIED AT
750mm BELOW PAVING.

NOTE: REFER TO CoS GENERAL CONDUITS IN FOOTWAY AND


CARRIAGEWAY DWG No: 5.1.1 FOR TYPICAL TRENCH DETAIL.

CoS APPROVED ELECTRICAL CONDUIT JUNCTION PIT REFER TO CoS


GENERAL LIGHTING PIT ARRANGEMENT DWG No: 5.1.6

ELE-DWG-042204
B PITS WITHIN FOOTPATH (MINIMUM CLASS C LID) B
L 715
W 580 *NOTE PIT WIDTH INCREASED TO SUIT CONDUITS.
202

D 800
JOINS DRG SLR-DJV-D40-ELE-DWG-042

3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT


3x80 HD uPVC ORANGE POWER CONDUIT PITS WITHIN ROAD OR ROAD CROSSINGS (MINIMUM CLASS D LID)
L 1395

JOINS DRG SLR-DJV-D40-


W 580

GOULBURN ST
D 1000

ELECTRICAL LEGEND
CoS STREETLIGHTING DISTRIBUTION BOARD
REFER TO CoS DRAWING 5.13 REV C.

REET
CIRCUIT DESIGNATION CoS-MSB-XX-XX-X
C 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT C
3x80 HD uPVC ORANGE POWER CONDUIT 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 1.7 m
ASSET NUMBERS
3x80 HD uPVC ORANGE POWER CONDUIT AUSGRID ASSET MUMBER SY-xxxxx
14.5 m
CoS ASSET NUMBER SP-xxxxx

12km000
SLR PROPOSED ASSET NUMBER SLR-ZCS-SPxxx

11km900
CoS ELECTRICAL PIT. REFER TO CoS DRAWINGS 5.1.5 REV C.
AND 5.1.6 REV C. FOR DETAILS.
860

RMS TRAFFIC CONTROLLER CABINET


880

980

13.1 m
920

940

960

12.1 m
CIVIL LEGEND
13.7 m 13.3 m 25.7 m
26.8 m 5.4 m
GENERAL
26.1 m
10.0 m
PROJECT SITE BOUNDARY

D GEORGE STREET SOUTHBOUND D


SURVEY
TRACK
PROPOSED LIGHT RAIL ALIGNMENT
REFER TO DESIGN PACKAGE DP05.2
PROPOSED CSELR STOP
REFER TO DESIGN PACKAGE DP01.2
10km000 LIGHT RAIL MAJOR KILOMETERAGE (CHAINAGE)
GEORGE STREET NORTHBOUND
OCS REFER TO DESIGN PACKAGE DP23 FOR FINAL DESIGN
23.6 m
25.6 m
9.4 m 15.9 m TRAFFIC SIGNALS - REFERENCE ONLY
4.0 24.6 m
m
TRAFFIC CONTROL SIGNAL WITH OVERHANG
860

880

2.2 m
11km900

13.9 m
920

12km000
980
2.2 m

940
11.8 m

960

8.5 m
E TRAFFIC CONTROL SIGNAL
E

7.3 m
9.0 m

REFERENCE DRAWINGS

GOULBURN STREE
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 1. FOR PROPOSED SMARTPOLE SCHEDULE REFER TO DRAWING
3x80 HD uPVC ORANGE POWER CONDUIT SLR-DJV-D40-ELE-DWG-042233 & 042234.
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
2. FOR CoS STREET LV LIGHTING CIRCUITS REFER TO DRAWING
3x80 HD uPVC ORANGE POWER CONDUIT
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT SLR-DJV-D40-ELE-DWG-042235.
3x80 HD uPVC ORANGE POWER CONDUIT 3. REFER TO POLE MANUFACTURERS DETAILS ABOUT POLE
TERMINATION FOR EACH SPECIFIC SERVICE.
4. FOR SLR EQUIPMENT REFER TO SMARTPOLE EQUIPMENT SCHEDULE

T
SLR-DJV-D40-OCS-DWG-062231
F NOTES 5. FOUNDATION PLANS F
SLR-DJV-D40-OCS-DWG-062201 TO 062208
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH THE CoS SYDNEY STREETS 6. CONDUIT DETAILS
TECHNICAL SPECIFICATION B8. STREET LIGHTING AND DP04.2 ROAD WORKS SLR-DJV-D40-OCS-DWG-062706
DRAWINGS AND ZONE CS DESIGN REPORT SLR-DJV-D40-ROD-REP-042001.
2. DESIGN BASED ON SURVEY MODEL CORR-SLR-AIA-MIO-000-CORR-004941- 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT

CAMPBELL STREET
GOULBURN STREET

HAY STREET
LIVERPOOL STREET
3x80 HD uPVC ORANGE POWER CONDUIT TOWN HALL RAWSON PLACE

CENTRAL STREET
20160822a_TOPO_Survey.12da.

ET

VE
BATHURST ST

CITY TUNNEL
WILMOT STRE
3. THESE DRAWINGS DO NOT SHOW THE EXISTING AUSGRID LV STREET LIGHTING

YA
EDD
SUPPLY RETICULATION. REFER TO DESIGN PACKAGE DP17 FOR LEVEL 3 DESIGN PITT STREET

CROSS
AND WILL BE MANAGED DURING CONSTRUCTION WITH AUSGRID AND ASP 1
CONTRACTOR.
4. REFER TO STRUCTURAL DESIGN DRAWINGS FOR SMARTPOLE FOUNDATION AND GEORGE
GEORGE STREET
CONDUIT COORDINATION. STREET
5. UPVC NEW DUCTS ARE TO BE INSTALLED AS SHOWN ON THE DRAWINGS ONCE
G G

ALBION PLACE

ULTIMO ROAD
THE COS HAVE GIVEN APPROVAL.
6. CONDUITS SHALL BE LAID ALONG THE ROUTE IN THE POSITIONS AND AT THE
DEPTHS DOCUMENTED BY THE CoS SPECIFICATION AND ON THE DRAWINGS. THE
FINAL POSITION AND DEPTH OF THE DUCTS MAY BE CHANGED ON SITE WITH THE
KEY PLAN
APPROVAL OF THE CoS TO AVOID OBSTRUCTIONS.
STREET LIGHTING PLAN Issued for Construction
SCALE 1 : 250 Sydtrac CCB ref:
DRAWING COLOUR CODED - PRINT ALL COPIES IN COLOUR SLR-D&C-D10-000-CCB-000146
SYDNEY LIGHT RAIL
This drawing and the information contained thereon have been created solely for a particular purpose and client.
CONSTRUCTOR DESIGNER CLIENT Transport for NSW and it's Consultants provide no warranty and accept no liability, arising from the use of this drawing
and the information shown thereon for any other purpose. This is protected by copyright. You may not reproduce any
of it in any form without the written permission of Transport for NSW. If you do, you may have to pay damages to
Transport for NSW or you may be prosecuted.

DRAWN P.HELLAWELL 07.03.17 ROADWORKS


J.SAWRAS 07.03.17 TOWN HALL TO RAWSON PLACE
DESIGNED
STREETLIGHTING CONDUIT PLAN - SHEET 3
DRG CHECK D.SMITH 07.03.17 FILE No. 3 OF 8
A PSH 07.03.17 IFC RC
REV BY DATE DESCRIPTION APPD DESIGN CHECK J.YAPP 07.03.17 STATUS C
DRG No. EDMS No.
A1 Original Co-ordinate System: MGA Zone 56 Height Datum: A.H.D. Scale: As indicated APPROVED R.CASIMIR 07.03.17 SLR-DJV-D40-ELE-DWG-042303 A

1 2 3 4 5 6 7 8 9 10 11 12
Plot Date & Time: 7/03/2017 3:37:40 PM
1 2 3 4 5 6 7 8 9 10 11 12

CONDUIT LEGEND
FOOTPATHS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED
TOWN HALL RAWSON PLACE AT 250mm BELOW PAVING
ROADS: 3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT BURRIED AT
A 400mm BELOW PAVING. A
FOOTHPATHS: 3x80 HD uPVC ORANGE POWER CONDUIT BURRIED AT
600mm BELOW PAVING.
ROADS: 3 X 80 HD uPVC ORANGE POWER CONDUIT BURRIED AT
750mm BELOW PAVING.

NOTE: REFER TO CoS GENERAL CONDUITS IN FOOTWAY AND

G-042205
CARRIAGEWAY DWG No: 5.1.1 FOR TYPICAL TRENCH DETAIL.

CoS APPROVED ELECTRICAL CONDUIT JUNCTION PIT REFER TO CoS


GENERAL LIGHTING PIT ARRANGEMENT DWG No: 5.1.6

JV-D40-ELE-DW
PITS WITHIN FOOTPATH (MINIMUM CLASS C LID)
203

L 715
B W 580 *NOTE PIT WIDTH INCREASED TO SUIT CONDUITS. B
JOINS DRG SLR-DJV-D40-ELE-DWG-042

D 800

PITS WITHIN ROAD OR ROAD CROSSINGS (MINIMUM CLASS D LID)

JOINS DRG SLR-D


L 1395
NOTE 5 W 580
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT
GOULBURN STREET

D 1000

TREET
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 3x80 HD uPVC ORANGE POWER CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT
ELECTRICAL LEGEND

CAMPBELL S
CoS STREETLIGHTING DISTRIBUTION BOARD
REFER TO CoS DRAWING 5.13 REV C.
CIRCUIT DESIGNATION CoS-MSB-XX-XX-X
C ASSET NUMBERS
AUSGRID ASSET MUMBER SY-xxxxx
C
CoS ASSET NUMBER SP-xxxxx

12km100
SLR PROPOSED ASSET NUMBER SLR-ZCS-SPxxx
12km000

CoS ELECTRICAL PIT. REFER TO CoS DRAWINGS 5.1.5 REV C.


AND 5.1.6 REV C. FOR DETAILS.
RMS TRAFFIC CONTROLLER CABINET

120
080
060

140
040
020

3.8 m
8.9 m
5.2 m

28.9 m
24.2 m 13.8 m 18.6 m
6.8 m
CIVIL LEGEND
2.3 m
25.9 m
GENERAL
PROJECT SITE BOUNDARY
D D
SURVEY
TRACK
CHINATOWN STOP PROPOSED LIGHT RAIL ALIGNMENT
REFER TO DESIGN PACKAGE DP05.2
PROPOSED CSELR STOP
REFER TO DESIGN PACKAGE DP01.2
10km000 LIGHT RAIL MAJOR KILOMETERAGE (CHAINAGE)

24.2 m
24.2 m OCS REFER TO DESIGN PACKAGE DP23 FOR FINAL DESIGN
18.9 m 31.2 m
7.8 m 9.3
m

m 14.6 m
TRAFFIC SIGNALS - REFERENCE ONLY
1.2 m 2.8
3.1 m
12km000

TRAFFIC CONTROL SIGNAL WITH OVERHANG


E E
020

140
120
12km100
TRAFFIC CONTROL SIGNAL

080
060
040

REFERENCE DRAWINGS
1. FOR PROPOSED SMARTPOLE SCHEDULE REFER TO DRAWING
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT SLR-DJV-D40-ELE-DWG-042233 & 042234.
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 2. FOR CoS STREET LV LIGHTING CIRCUITS REFER TO DRAWING
3x80 HD uPVC WHITE COMMUNICATIONS CONDUIT 3x80 HD uPVC ORANGE POWER CONDUIT
3x80 HD uPVC ORANGE POWER CONDUIT SLR-DJV-D40-ELE-DWG-042235.
3x80 HD uPVC ORANGE POWER CONDUIT
3. REFER TO POLE MANUFACTURERS DETAILS ABOUT POLE
TERMINATION FOR EACH SPECIFIC SERVICE.
F NOTES 4. FOR SLR EQUIPMENT REFER TO SMARTPOLE EQUIPMENT SCHEDULE F
SLR-DJV-D40-OCS-DWG-062231
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH THE CoS SYDNEY STREETS 5. FOUNDATION PLANS
TECHNICAL SPECIFICATION B8. STREET LIGHTING AND DP04.2 ROAD WORKS SLR-DJV-D40-OCS-DWG-062201 TO 062208
DRAWINGS AND ZONE CS DESIGN REPORT SLR-DJV-D40-ROD-REP-042001. 6. CONDUIT DETAILS
2. DESIGN BASED ON SURVEY MODEL CORR-SLR-AIA-MIO-000-CORR-004941- SLR-DJV-D40-OCS-DWG-062706
20160822a_TOPO_Survey.12da.

CAMPBELL STREET
GOULBURN STREET

HAY STREET
LIVERPOOL STREET
TOWN HALL RAWSON PLACE

CENTRAL STREET
3. THESE DRAWINGS DO NOT SHOW THE EXISTING AUSGRID LV STREET LIGHTING

ET

VE
BATHURST ST

CITY TUNNEL
WILMOT STRE
SUPPLY RETICULATION. REFER TO DESIGN PACKAGE DP17 FOR LEVEL 3 DESIGN

YA
EDD
AND WILL BE MANAGED DURING CONSTRUCTION WITH AUSGRID AND ASP 1 PITT STREET

CROSS
CONTRACTOR.
4. REFER TO STRUCTURAL DESIGN DRAWINGS FOR SMARTPOLE FOUNDATION AND
CONDUIT COORDINATION. GEORGE
GEORGE STREET
5. UPVC NEW DUCTS ARE TO BE INSTALLED AS SHOWN ON THE DRAWINGS ONCE STREET
THE COS HAVE GIVEN APPROVAL.
G G

ALBION PLACE

ULTIMO ROAD
6. CONDUITS SHALL BE LAID ALONG THE ROUTE IN THE POSITIONS AND AT THE
DEPTHS DOCUMENTED BY THE CoS SPECIFICATION AND ON THE DRAWINGS. THE
FINAL POSITION AND DEPTH OF THE DUCTS MAY BE CHANGED ON SITE WITH THE KEY PLAN
APPROVAL OF THE CoS TO AVOID OBSTRUCTIONS.

STREET LIGHTING PLAN Issued for Construction


SCALE 1 : 250 Sydtrac CCB ref:
DRAWING COLOUR CODED - PRINT ALL COPIES IN COLOUR SLR-D&C-D10-000-CCB-000146
SYDNEY LIGHT RAIL
This drawing and the information contained thereon have been created solely for a particular purpose and client.
CONSTRUCTOR DESIGNER CLIENT Transport for NSW and it's Consultants provide no warranty and accept no liability, arising from the use of this drawing
and the information shown thereon for any other purpose. This is protected by copyright. You may not reproduce any
of it in any form without the written permission of Transport for NSW. If you do, you may have to pay damages to
Transport for NSW or you may be prosecuted.

DRAWN P.HELLAWELL 07.03.17 ROADWORKS


J.SAWRAS 07.03.17 TOWN HALL TO RAWSON PLACE
DESIGNED
STREETLIGHTING CONDUIT PLAN - SHEET 4
B PSH 07.03.17 IFC RC DRG CHECK D.SMITH 07.03.17 FILE No. 4 OF 8
A DG 07.02.17 PRE-SUBMISSION DESIGN STAGE 3 RC
REV BY DATE DESCRIPTION APPD DESIGN CHECK J.YAPP 07.03.17 STATUS IFC C
DRG No. EDMS No.
A1 Original Co-ordinate System: MGA Zone 56 Height Datum: A.H.D. Scale: As indicated APPROVED R.CASIMIR 07.03.17 SLR-DJV-D40-ELE-DWG-042304 B

1 2 3 4 5 6 7 8 9 10 11 12
Plot Date & Time: 7/03/2017 3:38:16 PM

You might also like