Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Water 2015, 7, 5115-5133; doi:10.

3390/w7095115
OPEN ACCESS

water
ISSN 2073-4441
www.mdpi.com/journal/water
Article

Hydraulic Jump and Energy Dissipation with Sluice Gate


Youngkyu Kim 1, Gyewoon Choi 2, Hyoseon Park 2 and Seongjoon Byeon 3,*

1
DOHWA Engineering Co. Ltd., 438, Samseong-ro, Gangnam-gu, Seoul 06178, Korea;
E-Mail: youngkyu@dohwa.co.kr
2
Department of Civil and Environmental Engineering, Incheon National University,
119, Academy-ro, Yeonsu-gu, Incheon 22012, Korea; E-Mails: gyewoon@incheon.ac.kr (G.C.);
kokomanara84@naver.com (H.P.)
3
International Center for Urban Water Hydroinformatics Research & Innovation, 169, Gaetbeol-ro,
Yeonsu-gu, Incheon 21999, Korea

* Author to whom correspondence should be addressed; E-Mail: seongjune@paran.com;


Tel.: +82-32-835-4760; Fax: +82-32-851-5730.

Academic Editor: Andreas Angelakis

Received: 14 April 2015 / Accepted: 11 September 2015 / Published: 22 September 2015

Abstract: Movable weirs have been developed to address the weaknesses of conventional
fixed weirs. However, the structures for riverbed protection downstream of movable weirs
are designed using the criteria of fixed weirs in most cases, and these applications cause
problems, such as scour and deformation of structures, due to misunderstanding the
difference between different types of structures. In this study, a hydraulic experiment was
conducted to examine weir type-specific hydraulic phenomena, compare hydraulic jumps
and downstream flow characteristics according to different weir types, and analyze hydraulic
characteristics, such as changes in water levels, velocities and energy. Additionally, to
control the flow generated by a sluice gate, energy dissipators were examined herein for their
effectiveness in relation to different installation locations and heights. As a result,
it was found that although sluice gates generated hydraulic jumps similar to those of fixed
weirs, their downstream supercritical flow increased to eventually elongate the overall
hydraulic jumps. In energy dissipator installation, installation heights were found to be
sensitive to energy dissipation. The most effective energy dissipator height was 10% of the
downstream free surface water depth in this experiment. Based on these findings, it seems
desirable to use energy dissipators to reduce energy, as such dissipators were found to be
effective in reducing hydraulic jumps and protecting the riverbed under sluice gates.
Water 2015, 7 5116

Keywords: weir; sluice gate; energy dissipator; hydraulic jump

1. Introduction

Weirs are structures installed across rivers in order to raise water levels and prevent backward water
flow for efficient water intake and waterway use. Previously, the concrete gravity dam (CGD) was a
frequently utilied weir type for water overflow weirs. The CGD slows water inflow from upstream before
reaching a weir and allows it to flow over the weir. Thus, the flow velocity falls and inflowing silt is
deposited. In this manner, the water storage capacity decreases and weirs lose their initial effectiveness.
Therefore, efforts have been made to develop various movable weirs to reduce such sedimentation
processes and fulfil their original purposes for the long term. Concerning movable weirs, there is a
turning gate-type movable weir, which turns a weir to discharge silt sedimentation, and a sluice
gate-type weir, which lifts a weir to do so [13].
With weirs in place, upstream water levels move up to ease water intake and waterway use. However,
the hydraulic jumps caused by weirs increase in terms of their head drop and velocity, thus causing bed
scour and other damage to hydraulic structures. As methods to prevent such scour, aprons and bed
protection have been installed in the lower parts of weirs as energy dissipators for hydraulic
jump control.
In order to protect hydraulic structures and rivers from the energy generated by hydraulic structures,
the United States Department of the Interior Bureau of Reclamation (USBR) established the Engineering
Monograph No. 25 in 1964 for the energy dissipators of hydraulic structures and energy reduction.
In the monograph, the hydraulic jump phenomenon was divided into four forms dependent upon
Froude numbers. Based on various other hydraulic experiment findings, it suggested 10 different types
of stilling basins and energy dissipators appropriate for each discharge type and spillway type.
The monograph has continuously upgraded its improvement measures since then [4].
Concerning broad-crested weirs and flows with Froude numbers between 2.5 and 4.5, which
accompany huge hydraulic changes, Bhowmik (1971) combined energy dissipators (baffle blocks and
end stills), presented 11 types of energy dissipators and examined each of their energy dissipation
performances [5]. Rajaratnam and MacDougall (1983) reported that partially submerged orifice flow
showed approximately a 50% reduction in scour depth compared with completely submerged orifice
flow, whereas its scour length increased by 25%50% [6]. Yoon et al. (1995) analyzed the scour hole
characteristics in a free-falling jet generated by drop structure dependent upon the existence of mound
in their weir experiment. They found that if a density Froude number increased, not only the equilibrium
scour depth, but also the mound heights moved up [7]. Hoffmans and Verheij (1997) utilized the ratio
of flow velocity at the weir discharge jump to the post-hydraulic jump velocity to suggest the maximum
scour depth. The researchers proposed that the maximum scour depth appeared at a distance amounting
to two times as far as the maximum scour depth from the scour start. They also suggested that
scour-caused riverbed variation could be observed up to 57 times longer than the maximum scour
length and 34 times wider than the maximum scour depth [8]. Concerning weir flow, Fahlbusch (2003)
presented an equation to calculate scour depths according to the different velocities and drop angles of
Water 2015, 7 5117

water-overflowing weirs. He reported that scour depths decreased as downstream water levels
increased [9].
Noshi (1999) measured velocity changes at the river bottom to assess the energy dissipation of end
sills in spillway flow. The researcher analyzed downstream hydraulic jump lengths and suggested they
were approximately 2.3 times as long as the downstream water level [10]. Verma and Goel (2003)
performed a hydraulic experiment and proposed a new shape of energy dissipator (wedge-shaped block)
as a way to reduce the jet flow discharged through culverts. The researchers also stated that tooth-formed
energy dissipators were more useful than the conventional rectangular dissipators in energy
dissipation [11]. Jeong (2011), in his hydraulic model experiment, proposed a method to calculate apron
length dependent upon upstream/downstream water levels with movable weirs and weirs fixed in
place [12].
Many studies have focused on measuring hydraulic jump lengths and the energy differences between
the upstream and downstream of weirs in order to determine the length of aprons or shorten hydraulic
jumps through energy dissipation. However, an insufficient amount of studies on movable weirs have
been developed more recently compared with studies on fixed weirs. Therefore, structures for river-bed
protection, which are applied in several river maintenance projects, have occasionally been determined
through the estimation of weighted values without factoring in the characteristics of different movable
weir types. Additionally, this study discusses the energy dissipator in particular as one of major
structures for riverbed protection. Therefore, this study examined the hydraulic phenomena generated
by the installation of a sluice gate-type movable weir and performed a hydraulic experiment to review
and propose an effective energy dissipation method. Through the experimental study and analysis,
hydraulic characteristics, such as the length of the hydraulic jump and the installation of an energy
dissipator, have been formulated for applications. In addition, this study sought to describe the design
criteria of energy dissipators for riverbed protection in movable weirs, which were inadequately reflected
in the present design standards.

2. Methodology and Experiment

To control hydraulic jump and enhance hydraulic jump efficiency, sills such as sharp-crested weirs,
broad-crested weirs or end sills at the bottoms of waterways are frequently used. The force acting upon
such a sill in the hydraulic jump rapidly decreases to the minimum as the end point of roller at
downstream of the hydraulic jump moves upward at a point where it almost overflows a sill. This impact
of sills can make the length of the scour risk zone shorter than a normal hydraulic jump phenomenon.
Then, as the hydraulic jump becomes shorter and moves further upstream, the force upon a sill gradually
increases to reach a certain level. Since such a rapidly varying flow is characterized as having an uneven
velocity distribution, the changes in force upon a sill seem to be because of the changes in velocity
distribution occurring between the starting points of the hydraulic jump to its end point. Consequently,
in a cross-section with unequal velocities, the momentum surges greatly. Theoretically, hydraulic jump
controlled by sills can be interpreted using the momentum theory. However, in the absence of a precise
theory of velocity distribution, an accurate quantification can hardly be made by just relying on theoretic
interpretation. An experiment for simulating the behavior of a sluice gate and an associated hydraulic
jump experiment have been carried out in different conditions to enable an investigation of the
Water 2015, 7 5118

characteristics of hydraulic jump, and to analyze energy dissipation, the physical experiment collects
data that are afterwards used to define relations, which are used as guidelines for design operations.

2.1. Experiment Equipment and Method

The open-channel system used in this experiment is a channel installed in a hydraulic experiment lab
of Incheon University, Korea.
The straight-line channel is 11.0 m in total length, 0.7 m in width, and 0.8 m in height and has
reinforced glass walls for flow observation. It has three distribution plates at the inlet to induce
steady-state inflow. Although inflow passes through the distribution plates to become steady, in order to
minimize the inlet contraction effect, a fixed weir and sluice gate weir were installed at points 2.0 m
away from the inlet. Vertical grooves were made on the left and right sides of the channel to install weirs
at the same height and adjust movable weir heights. Since it is occasionally hard to measure the variation
of flow surface created by the hydraulic jump, besides using a velocimetry and a point gauge,
piezometers were installed on the bottom of the channel to monitor water pressure to estimate hydraulic
characteristics. The installed piezometers were attached to the walls for the purpose of observation.
In order to install and adjust the weirs and piezometers, an acrylic-plate channel was made by
distancing each 0.10 m inward from the left side, right side and bottom. Figure 1 shows the channel cross
section. The piezometers were installed in three rows at 0.08 m intervals toward the channel center on
the left side from a point approximately 0.20 m away from the weir installation. The installation intervals
were 10 cm long, and a total of 60 piezometers were installed. The maximum water supply of the
installed pump was 0.056 m3/s. However, given the channel size and to ensure constant flow
maintenance, 0.026 m3/s was supplied as the maximum. The variation of the pressure head caused by
the installation of the weir could be observed through the piezometers. In order to measure detailed
hydraulic characteristics, the 2-D velocity meter (VP1200, KENEK Corp., Tokyo, Japan), which uses
very thin sensor needle, was used to minimize flow interference.

(a) (b)

Figure 1. Cont.
Water 2015, 7 5119

(c)

Figure 1. Structure diagram of channel. (a) Cross-sectional view with piezometer; (b) Floor
plan showing the piezometer hole in the channel; and (c) weir and the channel.

As the fixed weir and sluice gate-type weir have different shapes, the centers of the two different
weirs were made sure to be in the same position for installation consistency.
The fixed weir was 0.1 m in height, 0.05 m in upper width, 0.11 m in lower width and had a 1:0.7
ratio for the overflow slope. The sluice gate-type weir was 0.3 m in height and 0.01 m in thickness.
Figure 2 shows the overflow-type weir.

(a) (b)

Figure 2. Overflow-type fixed weir (a) plan of fixed weir installation; (b) photo of weir
installed in the channel.

As the sluice gate movable weir changes its openness heights, the experiment devices should be
structured to accept such changes. Therefore, after fixing the weir, grooves of 0.01 m width and
0.005 m depth were made on the left and right walls of the channel for the free height change. To prevent
possible leakage through the weir bottom when the sluice gate is completely closed, the same 0.01 m
wide and 0.005 m deep grooves were made and the back wall of the fixed weir was elongated by
0.005 m to fit in, as shown in Figure 3.
As mentioned in the introduction on the effectiveness of energy dissipators in the use of a
conventional fixed weir, it was found that tooth-formed blocks were more effective than total
cross-section installation. However, as the present study does not aim to examine certain targeted rivers,
but rather to produce experiment results based on unit width, the authors tried to install the whole widths
of the experiment channel throughout, as shown in Figure 4.
Water 2015, 7 5120

(a) (b)

Figure 3. Sluice gate-type movable weir (a) plan of sluice gate installation; (b) photo of
sluice gate installed in the channel.

(a)

(b)

Figure 4. Installation diagram of energy dissipator: (a) Horizontal plan; (b) Longitudinal plan.

The dissipators used herein were 500 mm long to fit into the whole width of the channel. The width
of the dissipators was set at 10% of the average downstream water depth measured in a preliminary
experiment. The heights of the dissipators were set at 5%, 10% and 15% of the average downstream
water depth in order to compare diverse cases, as in Table 1, which shows the height of the model.
Water 2015, 7 5121

Table 1. Height of energy dissipator.


Height of Energy Dissipator (Hb)
Mean Downstream Depth
5% 10% 15%
100 mm 5 mm 10 mm 15 mm

In this research, different flow patterns were investigated according to weir installation types and
hydraulic jump starting points and their lengths were measured. To compare the flow patterns of fixed
weir and sluice gate-type movable weirs, the constant upstream water level of the fixed weir was
measured and applied to the movable weir case, since the fixed-weir upstream water levels were constant
at each different flow rate. In order to keep the upstream water level constant in the movable weir case,
its opening rate was adjusted.
In the movable weir experiment herein, the openness height was changed to produce Froude numbers
to measure and compare the velocities and water levels at the discharge point from the gate.
The measurement points were marked on the upper part of the experiment channel to ensure the
measurement was performed at the same point. The main measurement points are shown in Figure 5.

(a) (b)

Figure 5. Measurement regions of fixed weir and movable weir (a) Measurement point of
fixed weir and (b) Measurement point of movable weir.

Figure 5 shows the following region-specific characteristics:


(1) Region 1: A supercritical flow region formed when water is discharged by the sluice gate-type
movable weir. The flow conditions in Region 1 and associated Froude number are used to
describe each experiment.
(2) Region 2: Hydraulic jumps appear in this region in the discharged water flow of the sluice
gate-type movable weir. The hydraulic jump lengths are calculated from the existing equations.
(3) Region 3: The discharged flow stabilizes after the hydraulic jumps in this region to show a similar
flow to that of the fixed weirs.
(4) Region 4: The upstream domain of the weir region.
Each region was separated based on distinguished flow characteristics. Region 1 with supercritical
flow, especially, showed different patterns from those of the fixed weir dependent upon flow rates.
To avoid the effect of the channel walls, the central part of the channel was measured in this experiment.
Water 2015, 7 5122

As fixed-weir flow and movable-weir flow are slightly different, the measurement locations were
determined as shown in Figure 5 to ensure identical factors were compared.
The supercritical flow region was recognized as Region 1; the hydraulic jump region as Region 2;
and the post-hydraulic jump flow identical to that of the weir-free open channel as Region 3.
Additionally, the upstream weir section elevated by the weir installation was recognized as Region 4.
To ensure the same upstream conditions, the movable weir openness heights were adjusted to meet the
equal water depth.
This study examined the flow characteristics variation according to sluice gate-type movable weir
operation and downstream water level conditions as well as hydraulic jump, changes in their lengths and
energy variation. To examine flow changes dependent upon the openness height of the movable weir,
the movable weir openness height was changed to help generate diversified flow patterns in the channel
after passing through the sluice gate. That is, the water flow moving through the sluice gate movable
weir showed a similar pattern to the flow through the orifice. Orifice flow was also diversified dependent
upon the submerged level, including the completely submerged orifice and partially submerged orifice.
Therefore, the opening rate of the sluice gate-type movable weir was determined to show diverse patterns
in this experiment. For each flow, the minimum movable weir openness height was determined by
opening the movable weir until supercritical flow and all upstream flows appeared in the experiment
channel. The openness height of sluice gate was then determined to make a similar condition to the fixed
weir under the same flow rate, as shown in Table 2.

Table 2. Condition of flow rate and openness height of sluice gate.


Flow Rate (m3/s/m) Openness Height (m) Remarks
0.036 0.026
There are additional openness heights (m) of extended cases for
0.044 0.036
Chapter 5 (Energy dissipation) (0.036, 0.039, 0.042 and 0.045)
0.052 0.036

2.2. Changes in Energy after Weir Installation

Regarding the energy loss other than the water depth fluctuation before and after the hydraulic jump,
is the amount of pre-hydraulic jump energy, , less than the post-hydraulic jump energy, ,
+
= = + + = ( ) 1 (1)
2 2 2

where (m) is a water depth before the hydraulic jump, (m) is a water depth after the hydraulic
jump as a conjugate depth, and (m/s) are the flow velocity of the pre/post-hydraulic jump,
3
respectively, and (m /s/m) is a unit of water flow rate in the channel.
However, based on the momentum equation:
1
( + ) = (2)
2

If Equation (3) is substituted into Equation (2),


( )
= (3)
4
Water 2015, 7 5123

The hydraulic jump-caused energy loss can be calculated simply with the pre/post-hydraulic jump
water depths. The specific forces for the pre/post-hydraulic jump water depths h1 and h2 are the same.
However, the specific energy curve shows that the specific energy of h2, E2, is smaller than the specific
energy of h1, E1, by . This is the energy loss due to the hydraulic jump.
If both sides of Equation (4) are divided by h1 and expressed by the post-hydraulic jump Froude
Numbers as Fr1,

3 + 1 + 8
= (4)
16 1 + 1 + 8

Equation (5) can be expressed solely by the function of the Froude Number Fr1 regarding the
pre-hydraulic jump water level and hydraulic jump-caused energy loss.
The pre-hydraulic jump specific energy, E1, is,

= + = + (5)
2 2

If both sides of Equation (6) are divided by h1,


1
=1+ =1+ (6)
2 2

If Equation (5) is divided by Equation (7),

3 + 1 + 8
= (7)
8 1 + 1 + 8 (2 + )

The / expressed by Equation (8) is called a relative loss.


(1 + 8 ) / 4 +1
=1 = (8)
8 (2 + )

In Equation (9), the ratio of pre/post-hydraulic jump specific energies ( / ) is called the hydraulic
jump efficiency. The hydraulic jump height refers to the difference between the pre/post-hydraulic jump
water depths or = , and the following relation formula can be proven.
3 + 1 + 8
= = (9)
2+

where / , / and / are called the relative hydraulic jump heights, pre-hydraulic jump
and post-hydraulic jump relative water depth, respectively.

3. Results

3.1. Flow Changed with Overflow-Type Fixed Weir and Sluice Gate-Type Mobile Weir

The hydraulic flow of the fixed weir and the sluice gate-type movable weir installation described in
the previous sections were compared and analyzed. The fixed and movable weir flow patterns were
analyzed while maintaining the flow and water level at the same levelsthe weir upstream conditions.
Table 3 shows the upstream conditions of the experiment.
Water 2015, 7 5124

Table 3. Experiment conditions.


Flow Rate (m3/s/m) q (m3/s/m) (m/s) (m)
0.036 0.19 0.19 0.14
Fixed weir 0.044 0.20 0.22 0.16
0.052 0.21 0.25 0.19
0.036 0.19 0.19 0.14
Sluice gate 0.044 0.20 0.22 0.16
0.052 0.20 0.26 0.19

As shown in the table, the experiment flow flowed in, and then the movable weir height was adjusted
to create equal upstream water levels and upstream conditions for both types of weirs. The hydraulic
jump lengths were divided by the water depth h1 in the supercritical flow region before the hydraulic
jump phenomenon occurred to generalize the hydraulic jump lengths. Table 4 shows the hydraulic jump
length per unit flow and Froude number measured at 1, and Figure 6 shows the hydraulic jump lengths
per unit flow.

Table 4. Hydraulic jump lengths and Froude number at each type of weir.
Fixed Weir Sluice Gate
Q (m3/s/m) / 1
(m) / Fr / Fr
0.036 0.02 55.30 3.36 0.02 90.55 3.16 35.25 (64%)
0.044 0.02 78.26 3.56 0.03 105.26 3.43 27.00 (35%)
0.052 0.03 91.25 3.89 0.03 112.32 3.74 21.07 (23%)

Figure 6. Hydraulic jump lengths occurring per unit flow rate.

The dimensionless value of the hydraulic jump ( / ) of the fixed weir at a flow of 0.036 m3/s/m
was 55.30, and that of the movable weir was 90.55. When the flow was 0.044 m3/s/m, the dimensionless
value of the fixed weir was 78.26 and that of the movable weir was 105.26. When the flow was
0.052 m3/s/m, the dimensionless value of the fixed weir was 91.25, and that of the sluice gate-type
movable weir was 112.32. The lower the flow, the more the gap between the two values increased, and
Water 2015, 7 5125

the maximum increase of 64% was recorded when the flow was 0.036 m3/s/m under the sluice gate-type
movable weir.
The differences in hydraulic jump lengths represented by the dimensionless expression as ( / )
were found to be 35.2, 27.0 and 21.1 for each flow, showing that the lower the flow, the longer the
difference of hydraulic jump lengths of fixed weir and movable weir. Compared with the fixed weir,
in the movable weir, the hydraulic jump length increase rate ranged from 64% to 23% in each case.
Figure 7 shows hydraulic jump length as the distance when the flow is stabilized according to the
Froude numbers of the discharge point.
Both the fixed weir and movable weir were found to have longer distances of hydraulic jump as the
Froude numbers became higher. When the Froude number was 3.7, the movable weir / was 112.32,
approximately two times larger than the fixed weir / , 55. The sluice gate-type movable weir was
found to have a longer hydraulic jump length than that of the fixed weir because the fixed weir diverted
flow to dissipate the energy at the bottom. Thus, sluice gate-type movable weirs may need a flow energy
dissipation facility in a place where the fixed weirs do not need one.

Figure 7. Hydraulic jump lengths occurring according to Froude numbers.

3.2. Flow Changes According to Different Openness Heights

In order to examine flow changes according to different openness heights of the sluice gate-type
movable weir, the openness height of the sluice gate-type movable weir was changed to generate diverse
flow patterns after passing through the sluice gate. That is, the post-sluice gate flow showed a similar
pattern to that of the flow through orifice. Additionally, the orifice flow was further divided into the
completely submerged orifice and partially submerged orifice. Therefore, the opening rate of the sluice
gate of the movable weir was set to observe diverse flow patterns herein.
The minimum movable weir openness height was determined by opening the movable weir until
supercritical flow and all of the upstream flows were observed in the experiment channel. The openness
height was then increased by 3 mm each time to analyze the flow changes.
In the movable weir, the discharged flow showed a high velocity and low water depth to create
supercritical flow with Froude numbers exceeding 1.0. However, as the movable weir height increased
and the discharged cross-sectional area of flow grew larger, the velocity decreased despite the same
Water 2015, 7 5126

amount of inflow. As the movable weir openness height moved up, the Froude numbers became smaller
at the discharge point, and the supercritical flow and hydraulic jump lengths were reduced.
If the flow increased, the post-hydraulic jump water levels moved up. Such water levels were found
to be higher at 0.044 m3/s/m than at 0.036 m3/s/m by 20 mm or more. Higher water levels affected the
upstream flow, thus reducing hydraulic jump sizes as well as hydraulic jump lengths to a considerable
extent. In particular, if a movable weir was high, the hydraulic jump was shortened. In this case,
the water level of the outlet area grew higher, the velocity decreased and hydraulic jump did not occur.
Figure 8 shows the conjugate water depths according to the Froude numbers of the outlet area.
Conjugate depth refers to the ratio of the water depth of the supercritical flow region to the water depth
of the post-hydraulic jump stabilization section. Depending on the sluice gate openness height, conjugate
water depth values vary.

Figure 8. Conjugate water depth according to experiment flow rates and Froude number.

As shown in Figure 8, the Froude numbers of the outlet area show a proportional relation with
conjugate depth. That is, due to the same amount of flow inflows, the post-hydraulic jump water depth
(h3) is the same. However, the discharge water depth reduction in the case of discharge results in
conjugate depth elevation and Froude number increases. Therefore, the conjugate depth and Froude
numbers have a proportional relation. However, if water is discharged while keeping the Froude number
the same, the flow rate increases to also increase the post-hydraulic water level as well as the
corresponding conjugate depth, as shown in Figure 8.

4. Hydraulic Jump Length Calculation Equation

The existing formula for hydraulic jump length presents the relationship between hydraulic jump
length and supercritical flow water depth according to Froude numbers. In this study, to compare the
existing formula regarding the net hydraulic jump length ( ) with the measurement results, Figure 9
was provided. The hydraulic jump length ( ) was separately reviewed herein.
Water 2015, 7 5127

Figure 9. Measurements and comparison with previous studies.

Many researchers have suggested formulas for hydraulic jump length, such as that presented by
Silvester [13]. Rajaratnams Equation and Bretzs Equation suggest that hydraulic jump length has a
linear relationship with Froude numbers. Silvesters Equation is presented in an exponential function,
although it is similar to Rajaratnam and Bretzs Equations [14]. Hager (1992) used a trigonometrical
function to structure a relation function along with a conversion formula [15]. In the present study,
Froude numbers within the range of 1.54.0 are considered, and they represent the lowest hydraulic
jump length calculated by Rajaratnams Equation, while representing the highest value calculated by
Hagers equation, similar to the present research results. Based on the research results,
a regression equation was structured and presented in Equation (13) as follows:

= 8.15 0.70 (13)


The root mean square error ( ) from the regression equation was calculated as 0.67. It seemed that
this was because the hydraulic jump lengths were changed by the effects of the left and right walls.
Many other studies have empirical formulas designed through experiments on fixed weirs. Compared
with the research results, all of the outcomes tend to be proportional to Froude numbers, showing the
similarity of the presented results. The difference between the Equation (13) and measurement is thought
to be because of subjective aspects of the experiment, such as changes in the experimental conditions
and errors. Therefore it is possible to estimate there is no huge difference in hydraulic jump lengths
between the movable weir and fixed weir in terms of using the dependent variable of Froude numbers
in supercritical condition, and the result is in direct proportion to the Froude numbers. However,
the hydraulic jump flow of the fixed weir and movable weir shows a huge gap due to the supercritical
flow length. In the same flow and upstream conditions, the fixed weir and movable weir show a
remarkable difference in hydraulic jump. However, concerning the hydraulic jump phenomenon
generated by the difference between pre/post-hydraulic jump energy, since the fixed weir and movable
weir have the same amount of energy dissipated by the hydraulic jump though their discharge types
Water 2015, 7 5128

being different, their hydraulic jump lengths are deemed similar. However, as shown in the experiment
results, there was a big difference in the distance from the weir to the end of hydraulic jump. Therefore,
the supercritical flow length excluding the hydraulic jump length is separately reviewed herein.
The distance to the hydraulic jump start point ( ) was reviewed by the ratio of the distance from the
movable weir to the post-hydraulic jump flow stabilized as the open-channel flow (L). By comparing it
with Froude numbers, the relationship between the two factors was expressed in a diagram, as shown in
Figure 10.
A linear regression equation was produced as in Equation (14):

= 0.25 0.18 (14)

The ratio of hydraulic jump length (Ls/L) was found to be proportional to the Froude numbers, and
the deviation (R2) was 0.86, representing a close relationship with the proposed regression equation.
As the distance from the movable weir to the hydraulic jump end point can be expressed as the sum
of the distance to the hydraulic jump start and hydraulic jump length, the Equation (15) is presented
as follows:
1
+1= (15)
0.25 0.18

The distance to the hydraulic jump starting point ( ) can be expressed by a relation equation between
a Froude number and hydraulic jump length ( ). In Equation (16), is expressed as an equation
regarding , as follows:
1
= 1 (16)
1.18 0.25

The equation described above can be used to estimate hydraulic jump lengths in hydraulic jump
phenomena frequently occurring in the conventional fixed weirs of a dam spillway as well as sluice
gate-type movable weir for designing aprons and bed protections.

Figure 10. Compared with Froude numbers, relationship between Ls and L.


Water 2015, 7 5129

5. Energy Reduction in Energy Dissipator

5.1. Energy Reduction According to Dissipator Installation Heights

In this study, energy dissipators were installed at heights of 5%, 10% and 15% of downstream water
depth to examine energy dissipation dependent upon installation heights with a flow rate specified as
0.052 m3/s/m. If the energy dissipators were not installed, the movable weir openness height was lowered
to create supercritical flow. In this case, a 0.53.9 m flow stabilization distance was found to be required.
However, with the energy dissipators in place, hydraulic jump occurred in the movable weir
downstream, shortening the flow stabilization distance to 0.40.8 m, approximately a 1/3 reduction from
the non-installation case. Additionally, with the energy dissipator in place, the higher the movable weir
openness heights were, the shorter the flow stabilization distance was.
If the movable weir openness heights were the same, the flow stabilization distances at 5% and 15%
dissipator heights ranged from 0.4 to 1.9 m, which were similar to each other. However, the 15%
installation height was found to have slightly higher numbers. The 10% dissipator installation height
showed similar results to those of the 5% and 15% cases if the movable weir openness heights were at
least 42 mm. However, if the movable weir openness heights were 39 mm or under, it showed smaller
values by a maximum of 50% compared with the 5% and 15% height cases. The flow stabilization
distance dependent upon energy dissipator installation heights was compared with the flow of the
movable weir discharge. Figure 11 shows the flow stabilization distances after discharge according to
Froude numbers.

Figure 11. Length of flow stabilization after discharge from movable weir and Froude numbers.

If the energy dissipators were not installed, the Froude numbers of movable weir-discharged flow
ranged from 1.342 to 3.437. The relation between the depth of supercritical flow and the length of flow
stabilization ( / ) were from 30 to 137. With the dissipators in place, in a flow with a similar Froude
number to that of the non-dissipator case, the dimensionless value of the length of flow stabilization
divided by the depth of supercritical flow ( / ) was found to have a similar pattern according to Froude
number. However, if the dissipators were installed, the dimensionless value of the length of flow
stabilization ( / ) ranged from 4.68 to 65.52, showing approximately a 50% reduction.
Water 2015, 7 5130

If analyzed according to the energy dissipator installation heights, when the Froude numbers were
2.0 or under, the 5% height showed slightly more significant results than the other heights, but the energy
dissipator heights were still not found to have a huge effect. However, if the Froude numbers exceeded
2.0, the 10% height showed that the dimensionless value of the length of flow stabilization ( / ) was
shorter, and these gaps grew larger with Froude number increases. To examine energy dissipation
according to energy dissipator installation, the energy at the discharge point in the movable weir ( )
was compared with the energy in the stabilized flow after discharge ( ).
Concerning the energy dissipation per unit length (( / ) according to dissipator heights, the 5%
dissipator height showed per-length energy dissipation of 0.082 for every 1.0 Froude increase. The 10%
height showed 0.126 and the 15% height showed 0.068, indicating the 5% and 15% heights had similar
energy dissipation effectiveness. However, the 10% height was found to have at least 1.5 times greater
energy reduction, as shown in Figure 12.
Regarding relative lossthe ratio of specific energy at the discharge point ( ) and the specific
energy reduced by the hydraulic jump ( )its calculation equation shown in Equation (4) and
measurement results were reviewed. Table 5 expressed the relative energy loss measured by the
experiment and calculated by theoretical principles as Equation (8) above. The relative energy loss in
both the measured values and calculated values was found to tend to decrease as the Froude numbers
decreased. This is because the weir upstream and downstream energy difference narrowed as the
movable weir openness heights increased. In the present study, the measured values in the experiment
were smaller than the theoretic values by 5%10%, representing the gap between the experiment
and theories.

Figure 12. Energy dissipation per unit length according to dissipation block heights.

The energy after the end of hydraulic jump phenomenon was similar in most of the cases, as the
downstream water level was fixed. However, at the same movable weir openness heights, the energy at
the discharge point ( ) was 135.44, 127.73 and 129.52 mm in the weir downstream at 5%, 10% and
15% heights, respectively, showing reduction. This is because the installed energy dissipators disturbed
the flow discharged by the movable weir and reduced the cross-sectional area of flow to slow it down.
Water 2015, 7 5131

Table 5. Relative energy loss (q = 0.052 m3/s/m).


Height of Openness Loss
Fr E1 E3 E
Dissipator Height (m) Observed Calculated
0.036 3.43 153.60 118.93 34.67 23% 32%
No issipator 0.039 3.16 144.24 115.06 29.18 20% 28%
0.042 3.14 144.94 117.29 27.65 19% 28%
0.036 3.07 136.81 113.46 23.35 17% 27%
5% of water
0.039 2.99 139.77 115.58 24.19 17% 26%
depth
0.042 2.59 129.74 113.11 16.63 13% 19%
0.036 2.81 131.91 111.72 20.20 15% 23%
10% of water
0.039 2.17 123.36 113.49 9.87 8% 12%
depth
0.042 2.51 127.92 112.80 15.12 12% 18%
0.036 2.75 129.97 109.07 20.90 16% 22%
15% of water
0.039 2.58 130.16 110.13 20.03 15% 19%
depth
0.042 2.43 128.45 112.76 15.69 12% 16%

5.2. Energy Dissipation according to Energy Dissipator Installation Location

For energy dissipation, how to install energy dissipators was reviewed in this research. Two methods
were reviewed regarding energy dissipator installation location and height. For each height,
the installation locations were differentiated to examine the resulting changes. In the previous section
on the changes in energy dissipator installation heights, three different heights were examined. For each
of these heights, the dissipators were moved in four different locations 50%, 60%, 70% and 100% of
downstream subcritical flow water depth (10 cm of this study) away from the movable weir. Figure 13
shows the increasing gaps in flow stabilization distances only according to Froude numbers both with
and without energy dissipator installation cases and no significant change dependent upon dissipator
installation locations.

Figure 13. Changes in water level and velocity according to dissipation block heights.
Water 2015, 7 5132

6. Conclusion and Summary

In this study, a hydraulic experiment was performed by using a channel with a fixed weir and sluice
gate-type movable weir installation to examine the resulting hydraulic jump and differences of each weir
type. In the experiment, energy dissipator installation was considered to protect the bed under the
movable weir. The following results were found:
Energy dissipators for energy reduction at the sluice gate were found to dissipate energy by more than
50% per unit length compared with the non-dissipator installation status if installed at a 10% height of
the average river water depth in a location as far as approximately 70% of the average river water depth.
Although the sluice gate-type movable weir showed similar hydraulic jump lengths to those of the
fixed weir, its supercritical flow length increased, so its length to the hydraulic jump start point rose
considerably. For this reason, it is deemed that aprons for bed protection from scouring need to be
24 times sufficiently longer by considering the Froude numbers upon discharge.
Regarding hydraulic jump or the energy dissipation issues of sluice gate-type movable weirs, when
movable-weir downstream water level differences grow larger or the discharge flow increases, their
openness height should be elevated (Fr < 2.5) to protect the downstream area.
While fixed weirs involve drop head and flow diversion in dissipating energy, sluice gate-type
movable weirs have no factor to help them dissipate energy other than the frictional force under the same
upstream conditions and in the same discharge flow. Therefore, such movable weirs require apron
installation of a sufficient length for frictional force-led energy dissipation.
In this study, a hydraulic experiment and numerical experiment were performed in a channel installed
with a sluice gate-type movable weir to review hydraulic jump distances and hydraulic jump size
changes. Thus, not only the hydraulic jump distances, but also the distances until hydraulic jump
occurrence were researched. As sluice gate-type movable weirs create a supercritical flow region, they
could cause hydraulic problems, including scouring in the bed due to flow velocity. In this case, it seems
necessary to install energy dissipators.
To overcome the limitations of this hydraulic experiment, future hydraulic and numerical experiments
are expected to involve more diverse conditions to propose a dissipation design for energy reduction and
bed protection in the downstream of sluice gate-type movable weirs.

Acknowledgments

This research was supported by a grant (12-TI-C01) from the Advanced Water Management Research
Program funded by the Ministry of Land, Infrastructure and Transport of the Korean Government.

Author Contributions

Youngkyu Kim led the work performance; and Gyewoon Choi coordinated the research and
contribution to writing the article; Hyoseon Park collected data through the experiment and review of
papers; Seongjoon Byeon generated the result and wrote the manuscript.
Water 2015, 7 5133

Conflicts of Interest

The authors declare no conflict of interest.

References

1. Kim, Y.J. Energy Dissipation Effect of the Downstream at Under Flow Movable Weir.
Ph.D. Thesis, Incheon National University, Incheon, Korea, 2013.
2. Sadati, S.K.; Speelman, S.; Sabouhi, M.; Gitizadeh, M.; Ghahraman, B. Optimal irrigation water
allocation using a genetic algorithm under various weather conditions. Water 2014, 6, 30683084.
3. Michalec, B. The use of modified Annandales method in the estimation of the sediment distribution
in small reservoirsA case study. Water 2014, 6, 29933011.
4. Peterka, A.J. Hydraulic Design of Stilling Basins and Energy Dissipators; A Water Resources
Technical Publication Engineering Monography No. 25; United States Department of the Interior
Bureau of Reclamation (USBR): Washington, DC, USA, 1964.
5. Bhowmik, G.N. Hydraulic Jump Type Stilling Basins for Froude Number 2.5 to 4.5; Report of
Investigation 67; Illinois State Water Survey: Champaign-Urbana, IL, USA, 1971.
6. Rajaratnam, N.; MacDougall, R.K. Erosion by plane wall jets with minimum tailwater. J. Hydraul.
Eng. ASCE 1983, 109, 10611064.
7. Yoon, S.; Lee, J.; Son, K.; Kim, J. Experiment study on downstream local scour of free-falling jet,
J. Korea Water Resour. Assoc. 1995, 28, 147154. (In Korean)
8. Hoffmans, G.J.C.M.; Verheij, H.J. Scour Manual; A.A. Balkema: Rotterdam, The Netherlands,
1997; pp. 6887.
9. Fahlbusch, F.E. Scour of rock due to the impact of plunging high velocity jets part I: A state-of-the-art
review. J. Hydraul. Res. 2003, 46, 853858.
10. Noshi, H.M. Energy dissipation near the bed downstream end sill. In Proceedings of of the 28th
IAHR Congress, Graz, Austria, 2227 August 1999; IAHR: Madrid, Spain; pp. 18.
11. Verma, D.; Goel, A. Development of efficient stilling basins for pipe outlets. J. Irrig. Drain.
Eng. Div. 2003, 126, 179185.
12. Jung, J. Estimation of Apron Length Considering Weir Installation. Ph.D. Thesis, Incheon National
University, Incheon, Korea, 2011.
13. Silvester, R. Hydraulic jump in all shapes of horizontal channels. J. Hydraul. Div. ASCE 1964, 90,
2355.
14. Rajaratnam, N.; Subramanya, K. Profile of the hydraulic jump. J. Hydraul. Div. ASCE 1968, 94,
663673.
15. Hager, W.H.; Bretz, N.V. Hydraulic jumps at positive and negative steps. J. Hydraul. Res. 1987,
24, 237253.

2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article
distributed under the terms and conditions of the Creative Commons Attribution license
(http://creativecommons.org/licenses/by/4.0/).

You might also like