This document is a checklist in Spanish for monitoring various systems in a data center over the course of a night shift from 10 PM to 6 AM. It includes checking levels for UPS systems, generators, temperature and humidity for various computer rooms, and temperature readings for chillers. The checklist is signed by the operator Christopher Rivera for the 3 PM to 6 AM shift.
This document is a checklist in Spanish for monitoring various systems in a data center over the course of a night shift from 10 PM to 6 AM. It includes checking levels for UPS systems, generators, temperature and humidity for various computer rooms, and temperature readings for chillers. The checklist is signed by the operator Christopher Rivera for the 3 PM to 6 AM shift.
This document is a checklist in Spanish for monitoring various systems in a data center over the course of a night shift from 10 PM to 6 AM. It includes checking levels for UPS systems, generators, temperature and humidity for various computer rooms, and temperature readings for chillers. The checklist is signed by the operator Christopher Rivera for the 3 PM to 6 AM shift.
This document is a checklist in Spanish for monitoring various systems in a data center over the course of a night shift from 10 PM to 6 AM. It includes checking levels for UPS systems, generators, temperature and humidity for various computer rooms, and temperature readings for chillers. The checklist is signed by the operator Christopher Rivera for the 3 PM to 6 AM shift.
Cdigo DSN-PR-001-OD-003 Versin 2.2 Desarrollado por: Mesa de Servicio Especializados - Direccin de Operaciones Revisado por: NOC Manager ADC - Direccin de Operaciones Fecha ltima actualizacin: 20 de Octubre 2015
Check List Mesa de Servicio Especializados
Fecha: 2/19/2017
Operadores: Christopher Rivera
Turno 3 (9p.m. - 6 a.m.)
Valor de Referencia 10:00 PM 11:00 PM 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM Observaciones UPS UPS A UPS B UPS A UPS B UPS A UPS B UPS A UPS B UPS A UPS B UPS A UPS B UPS A UPS B UPS A UPS B L1 Capacity Output L2 Capacity Output < 80% L3 Capacity Output Output KW < 200 KW Generadores GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B GEN-A GEN-B Modo (Automatico) Automatico Nivel de combustible(%) > 40% AAPs Servidores AAP-2 AAP 1 AAP-4 AAP-6 AAP-3 AAP-8 AAP-5 AAP-10 Temperatura > 18 < 30 Humedad > 45 < 75 AAPs Servidores AAP-7 AAP-12 AAP-9 AAP-14 AAP-11 AAP-16 AAP-13 AAP-15 Temperatura > 18 < 30 Humedad > 45 < 75 AAPs Telecom AAP-19 AAP-20 AAP-19 AAP-20 AAP-19 AAP-20 AAP-19 AAP-20 Temperatura > 18 < 30 Humedad > 45 < 75 AAPs cto Electrico AAP-17 AAP-18 AAP-17 AAP-18 AAP-17 AAP-18 AAP-17 AAP-18 Temperatura > 18 < 24 Humedad > 45 < 75 AAP-22 AAP-22 AAP-22 AAP-22 AAP-22 AAP-22 AAP-22 AAP-22 AAP-22 Temperatura > 18 < 24 Humedad > 45 < 75 AAP-23 AAP-23 AAP-23 AAP-23 AAP-23 AAP-23 AAP-23 AAP-23 AAP-23 Temperatura > 18 < 24 Humedad > 45 < 75 AAP-24 AAP-24 AAP-24 AAP-24 AAP-24 AAP-24 AAP-24 AAP-24 AAP-24 Temperatura > 18 < 24 Humedad > 45 < 75 CHILLER Chiller A Chiller A Chiller A Chiller A Chiller A Chiller A Chiller A Chiller A Temperatura Evaporator Return > 11 < 16 Supply Fluid > 9 < 14