Download as pdf
Download as pdf
You are on page 1of 9
ZXZ SERIES SPEED MEASURE AND CONTROL METER OPERATING MANUAL CHHC CHONGQING HUAYUAN HYDROELECTRIC TECHNICAL ENGINEERING CO., LTD ZXZ SERIES SPEED MEASURE AND CONTROL METER _ CONTENTS 1 General description ..... 2 Principle and structure... 3 Basic technical feature... 4 Operating instruction ..... 5 Explanation for backboard wiring... we =2 4 wd 18 7 6 Installation manual for impulser... 7 Explanation for type selection... oN 8 Contact Document source | Proposing department Mark | Number |Mod. Doc. No. 2XZ SERIES SPEED MEASURI | ZXZ series speed measure and control meter is a kind of device for measure speed of water turbine-generator set in hydroelectric power station and give corresponding control signal which is from machine side PT or gear disc, the speed measured can be displayed via absolute value of speed, frequency or speed percentage In ZXZ series speed measure and control meter, there are & pairs of contacts, which can be adjusted in region of operation, and even more it is able to satisfy operation condition at power station owing to wide setting range. Corresponding speed signal can output DC4 - 20mA current. The speed measure and control meter is a sort of advanced computer cycloscope, which can supply communication interface, and multifunction such as measurement, contro! and communication are centered on it 2 Principle and structure Micro controller is acted as the kernel of ZXZ series speed measure and control meter, so it has many advances such as high precision, powerful function and easy | to operate. First input frequency source and carry out filtering, reshape, isolation via hardware circuit, and then ingress micro controller through the medium of software to make calculation, compare and filter: at last drive display part to carry out display, and drive relay to make corresponding movement. Speed measure and controi meter can communicated by means of communication interface. Thereof principle block diagram as Fig.1: Fig. 1 ieee | PT Signal >| oad || oo RSS a —— =e ruses dsc gm |____,ISignal process |——»| SCM ae. | system | >| Rete ive circuit Power supply |———> +5V | | a i ee | [4-20mA Output ZXZ SERIES SPEED MEASURE AND CONTROL METER Measure and control meter can apply standardized panel-mounted instrument case. | overall dimension is 16080250mm, perforation size for panel is 152 76mm. itis digital frequency display and signal indicating lamp for front panel, and rear terminal is used for input PT signal and fluted disc impulse signal, output relay, and connecting communication interface and power supply. Schematic diagram for panel as follows: 2XZ-02. HAUSE ‘SPEED MEASURE AND CONTROL METER Com Gear PRIMA MLA ARAL I Coonga hanan sonoma emmeingco.tw | S&C | F DWZ03 HMMM ‘SPEED MEASURE AND CONTROL METER Gear : : rs Twi fo unianes eee || set | cone LA) |W | eos honing Husuon Haat Techical Engreerng CO, Lis ZXZ SERIES SPEED MEASURE AND CONTROL METER 3 Basic technical feature 3.1 Frequency measurement scope: Frequency: ~99.99Hz Speed percentage: 1~200% 3.2 Input voltage: 0.3V~120V 3.3 Accuracy of measurement: ++0.01Hz 3.4 Output signal: Only 8-way open contacts, and every point can be amended by user at setting range. 3.5 Output contact capacity: 5A/250VAC; SA/30VDC 3.6 Communication interface: RS485 3.7 Overall dimension: 160 80250mm 3.8 Perforation size: 152 76mm 3.9 Operational power supply: AC85~265V,DC110V,DC220V 3.10 Dielectric strength: All circuit can withstand impact under AC1500V, 50Hz for 1 minute. 3.11 Insulation resistance: not less than 5MQ while relative humidity is 80% and temperature is +25 °C 3.12 Work environment: temperature is within —10°C ~+50°C. humidity< 85% 3.13 Power consumption: 7.5W. 4 Operating instruction 4.4 Starting up and electrify Turn on power switch and enter into speed measuring state after electrified ‘Speed, frequency and percentage of speed can be checked through operating key. No*** Speed f**.** Frequency PE ** Percentage of speed 4.2 Handling instruction 4.2.1 Button Setting: Press the key to modifying state of parameter or confirm after amended parameter. Please contact with company to ask for amendment password of parameter to ensure that the parameter is not amended at discretion. [Switchl: Press the key to move the cursor to modified position required. “A |: Push parameter key #1. (Ly |: Push parameter key -1 4.2.2 Set RS485 communication: 4.2.2.1Set RS485 communication baud rate: Press [A or [| ¥ key. RS485 communication baud rate can be: 1 (1200), 2(2400), 3(4800), 4(9600) 4.2.2.2 Set RS485 communication cell address: No. of communication equipments is ZXZ SERIES SPEED MEASURE AND CONTROL METER _ changed from 1 to 63. a. Set number of pole-pairs: Press [A | or [ ¥ key, pole pair number for generator should be within 1-60, according to formulae n=60f/P, work out speed n (P is pole pair number and can be set) . Note: press "reset" key to make it to reset right if occur abnormal state. it'd better to not press the key if no necessity. Setting table for parameter [ Display ‘Specification Range ue Relay operation point 1, setting rangeO—180% -—-|-—»«0-90Hz_ ra Deviation for relay operation point: setting range 02% | 0 1 of 0.2Hz | [2 | Relay operation point 2. setting range 0— 180% 0-902 | £2 Deviation for relay operation point: setting range 0—2% 0.1 or 0.2Hz jus Relay operation point3, setting range 0—180% | 0-90Hz | £3 __ | Deviation for relay operation point: seting range 0—2% | 0.1 or 0.2Hz L4 Relay operation point 4, setting range 0— 180% 22 on one E4 Deviation for relay operation point: setting range 0—2% | 0.1 or 0.2Hz | 5 Relay operation point 5, setting range 0— 180 % | “0-90Hz 5 _| Deviation for relay operation point: setting range 0—2% a 0.1 or O.2Hz Le Relay operation point 6, setting range 0—180% 0-90Hz E6 Deviation for relay operation point: setting range 0—2% | 0.1 or O.2He 7 | Relay operation point 7, setting range 0—180% | 0-90Hz 7 __| Deviation for relay operation point: setting range 0—2% | 0.1 ord 2Hz | LB | Relay operation point 8, setting range 0—180% | _0-90Hz £8 __| Deviation for relay operation point: setting range 0—2% | 0.1 or 0.2Hz P| Number ofpole-pairs of generator | 60 | Input signal mode, Omainly via PT signal, 1=mainly via | fluted disc signal. _ CP | Number of teeth of fluted disc AA | Communication address 7 re T Baud rate of communication: 4(4200), 2(2400), 3(4800) and) 4 4(9600) ! ZXZ SERIES SPEED MEASURE AND CONTROL METER b. Corresponding relation for movement interval and outlet K1, K2, K3, K4 L120mm, gear height =20mm. Impulser should be mounted and perpendicular with axial line of fluted disc. and vertical distance between fluted disc should be greater than 0.5mm and less than 4mm. Installation schematic diagram is shown as in Fig. 2 Sensor wiring, hereinto brown wire is for +24V,, black for signal wire. blue for ground wire 0. Simm'

You might also like