4 Design of triangulated securing frame (ISMC 150)

Total weight of the girder = 20 Tonnes

Length of the girder = 35.441 m

Width of bottom flange = 0.75 m

Depth of the Girder = 1.85 m

Wind load = 240 Kg/m2

Total wind load= 35.441* 1.85* 240/1000 = 15.736 Tonnes

Total wind load at each


15.736/2 = 7.87 Tonnes
end=

Load resisted by self


.75/2* 20/2 = 3.75 Tonnes
weight of girder=

Stability moment due to a frame

Using ismc 150 as Digonal support

Area = 21.3 cm2

Moment of inertia = 788 cm4

Radius of gayration = 2.2 cm

Max length of prop = 250 cm

Slenderness ratio = 113.636

Safe compressive stress as per is 800 table 5.1 = 690 Kg/cm2

safe load bearing capacity = 14.697 MT

Total combine capacity = 18.447 MT

Ratio of stablizing = 2.345


> 2

safe