1. Feeder panel should be local selection; 1-20 loops should be removed.
2. Both tacho signal should be taken in signal conditioning module. Port
3. Switch should be in cal mode. 4. Total no teeth= 172 .4 nos of radium tape should be applied in equal distance= 43 teeth, . As radium cross by tacho. It blinks. 5. Speed should be minimum. 6. Mode ILC1-LC2I< 500. LC1= 10000-13000 7. Check nut should be rotated to adjust the load cell. 8. LC1 & LC2 should be properly fitted in groove. 9. Eveling rod should be applied. 10.Self check,9 no press- LC1=?, LC2=? 11.Program press, 1. Enter speed= 300 12.Tare cal- at load disengage, 41 to 49 note it in program 13.Deviation value- 0.5 t0 0.6 14.Apply engage. Self check, 9. LC1-LC2 15.Press span calibration. 16.Enter. 17.Deviation factor should be below 0.5. note down the parameter 18.Switch should be in operation mode. And remove the tacho.