Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

PROJECT UK

CLIENT

CONSULTANT
JOB TITLE

Notional Load

As per AISC Code Notional load is 0.2% of total factored gravity load.

Notional Load (N) =

Total factored load =

Factored Load (Y) =

Notional Load (N) =


=

This Load is applied from each side and evaluated seperatly

From STAAD report maximum deflection at worst case

As per AISC Code of std practice Tolerance for allowable Column deflections

The actual deflection is < allowable deflection, hence Safe

Wt Area/ln KN
Self Weight 35.958
Dead Load Floor mtl m2 1 114 114
Dead Load on mem lm 1.5 50 75
Dead Load on Stair lm 5 1.603 8.015
Dead Load due to LCD lm 3 4.62 13.86
Dead Load due to accessories 50 % m2 3 114 342
Live Load m2 5 114 570
Total
0.002 x total factored load (Y)

Liveload + Componenets Load + Load due to wall above deck + LCD load + Self weight of deck etc.

100,000 Kgs (approx.)

0.002 x 100000
200 Kgs

= 2.18mm

= L/500
where as, height of Deck (L) = 3200
= 3200 / 500
= 6.7mm

Kg Factor
3666 101.9523
11623 101.9523 1596
7646 101.9523 5262
817 101.9523
1413 101.9523
17434 101.9523
58113 101.9523
100712
weight of deck etc.