DE TRANSFORMADOR

DE SERVICIOS AUXILIARES REFERENCES/STANDADS


400/230 CA (T-100) DE GENERADOR DIESEL MODIFICACION CANAL ALFALFAL T-110 -CODE -DESCRIPTION
OBRA SUPERFICIAL LAS LAJAS DIAGRAMA
400/230V CA (T-100) DISTRIBUTION BOARD ALTERN CURRENT
MODIFIF CHANNEL ALFALFAL DESCARGA ALFALFAL
630-SC-PLA-080
LOW VOLTAGE SINGLE-LINE DIAGRAM FOR MODIFY
FROM TRANSFORMER CHANNEL ALFALFAL

OF AUXILIARY SERVICES FROM DIESEL GENERATOR TRANSFORMADOR Y GRUPO ELECTROGENO


6305-EL-PLA-7010 GENERATOR AND TRANSFORMER
400/230 AC (T-100) 400 / 230V AC (T-100)
DIAGRAMA UNIFILAR DE SERVICIOS AUXILIARES
6305-EL-PLA-7010) 6305-EL-PLA-7010) 6305-EL-PLA-7012 CORRIENTE CONTINUA
DIRECT CURRENT SINGLE-LINE DIAGRAM FOR AUXILLIARY
SERVICES
/ SYMBOLS
T-110
NOTAS - NOTES
CARGA DE 15 KW
CHARGE OF 15 KW 1. EL CONTRATISTA FABRICARA Y PROBARA LOS
TABLEROS COMPLETOS,ESTOS DEBEN SER A PRUEBA DE POLVO,
CHORRO DE AGUA Y NIEVE TIPO IP65 CONFORME A LA NORMA DIN
40050 O NEMA 4.
2. EL CONEXIONADO INTERIOR DE CADA TABLERO SER EN
1 DE 2 CERRADO CABLE THHN CON UNA MINIMA DE 14 AWG Y
INTERRUPTOR QUE LO PROTEGE.
3. TODOS LOS CONDICTORES LLEVAR
1 OF 2 CLOSED
MEDIANTE MARCAS ADHESIVAS Y SE POR MEDIO DE
AUTOMATIC SWITCHING
4. TODOS LOS INTERRUPTORES DE LOS TABLEROS CON
TERMOMAGNETICA DE LOS CALIBRES INDICADOS Y
CAPACIDADES DE RUPTURA DE 16 KA, PARA 400(V),
PROTECCION DE MINIMA TENSION NORMAS IEC 157-1 (P1) 6 UL 489.
5. LOS CONTACTORES QUE EL CONTRATISTA
UNDER VOLTAGE PROTECTION
CON BOBINA DE 24 DC PARA LOS CALIBRES INDICADOS, PARA
SERVICIOS AC-3.
6. EL GABINETE SE DE TAL FORMA QUE LOS EQUIPOS
TENGAN UNA RECOMENDADA POR EL
FABRICANTE.PARA PERMITIR UNA ADECUADA Y

VOLTIMETRIC SELECTOR
7. TODOS LOS EQUIPOS DE COMANDO Y SE
CON TAPA CUBRE EQUIPOS Y TODAS LAS BARRAS
EXPUESTAS DEBEN SER PROTEGIDAS CONTRA CONTACTOS
ACCIDENTALES, DE ACRILICO CON UNA DE
PELIGRO.
POINT PROTECTION TEST 8.
9. SE CONSIDERAR ESPACIO NECESARIO PARA BORNES DE

10. (NA) NORMALMENTE ABIERTO


11. (NC) NORMALMENTE CERRADO
POINT INDICATION TEST

1. BOARDS WILLBE DESIGN,BUIT AND TASTED BY THE


CONTRACTOR,AND SHALL BE DUSPROOF,WATERPROOF AND
SNOWPROOF.BOARDS MUST BE IP66 TYPE ACCORDING TO DIN
THERMAL AND MAGNETIC PROTECTION
40050 OR NEMA 4 STANDARD.
2. INSIDE BOARD CONEXION SHALL BE WITH A MINIMUM 14AWG WIRE
THHN TYPE,AND WITH PROTECTION SWITCH.
3. WIRES SHALL BE IDENTIFIED WITH ADHESIVE MARKS,AND WIRING
VOLTIMETRO THROUGH PVC WIREWAYS.
VOLTMETER 4. CIRCUITS BREAKERS SHALL HAVE THERMOMAGNETIC
PROTECTION FOR SPECIFIED GAUGES,AND 16 KA BREAKING
CAPACITY FOR 400 (V), ACCORDING TO STANDARDS IEC 157-1 (P1)
6 UL 489.
5. CONTACTOR COIL SHALL BE 24 DC FOR SPECIFIED GAUGES, FOR
MOTOR AC.3 SERVICES.
6. CABINET DIMENSIONS SHALL FOLLOW MAKERS
MOTOR
RECOMMENDATIONS TO ALLOW GOOD OPERATION AND
TIERRA/GROUND 7.
VENTILATION UNDER LOCAL CLIMATE.
CONTROL AND SIGNALING EQUIPMENT SHALL BE INSTALLED WITH
(N) SELECTOR
LIDS.ALL EXPOSED BARS SHALL BE COVERED WITH ACRYLIC TO
PREVENT ACCIDENTS,AND MARKED "DANGER ".
8. THE BOARD MUST HAVE AN INTERNAL HEATER.
SELECTOR SWITCH 9. IT MUST CONSIDER ENOUGH SPACE FOR THE PLC SIGNAL
TERMINALS.
10. NORMALLY OPEN (NO)
11. NORMALLY CLOSED (NC)
TRANSFORMADOR DE CORRIENTE
CURRENT TRANSFORMER

MEDIDOR MULTIFUNCIONAL
MULTIFUNCTIONAL METER

REVISIONES- REVISIONS

LOW VOLTAGE CABLE

/ GROUND
THREE-PHASE TRANSFORMER
TRIANGLE STAR CONNECTION

A00 15-03-17 SZE MGM MOJ FUP


FIRST EMISSION
FECHA
REV PROY REV REV APR APR
DATE DESCRIPTION

CON MANDO MOTORIZADO Y MANUAL,


CON MECANISMO DE DISPARO LIBRE,

CON
HEATING CABINET OF
AUXILIARY SERVICES

ALTO MAIPO
ALFALFAL CHANNEL

BATTERY CHARGER

DISPARO REMOTO, UN CONTACTO


BATTERY CABINET
CABINET HEATING

AUXILIAR DE CIERRE Y OTRO DE


AIR EXTRACTOR -
COMMUNICATION
ELECTRIC CARIN

RADIATOR GATE

APERTURA.
TECLE MOTOR

AVAILABLE 1

AVAILABLE 2

AVAILABLE 3
GEARMOTOR

630-MOT-001

630-MOT-002

630-MOT-022

TRIPOLAR CONNECTION DEVICE, WITH


LIGHTING

MOTORIZED AND MANUAL CONTROL, WITH


ICER OF

PLUGS

FREE TRIGGER MECHANISM, THERMAL


OVERLOAD, MAXIMUM CURRENT, MANUAL
TRIGGER WITH
RETAINER, REMOTE TRIGGER, AN
AUXILIARY CLOSURE CONTACT AND
OTHER OPENING. -AREA
ARMARIO DE SERVICIOS

(UNIFILAR REPRESENTATION)
6300 SISTEMA LAS LAJAS
ARMARIO DE BATERIAS
EXTRACTOR DE AIRE -
MOTORREDUCTOR

OBRAS SUPERFICIALES LAS LAJAS-DESCARGA MAINTENES


DE COMPUERTAS
CANAL ALFALFAL

DESHIELADORES

SURFACE WORKS LAS LAJAS-MAITENES DISCHARGUE


CARGADOR DE
MOTOR TECLE

DISPONIBLE 1

DISPONIBLE 2

DISPONIBLE 3

DIAGRAMA UNIFILAR DE SERVICIOS AUXILIARES CA Y CC


RADIADORES

ALUMBRADO
630-MOT-001

630-MOT-002

630-MOT-022

AUXILIARES

AC & DC AUXILIAR POWER SUPPLY SINGLE LINE DIAGRAM


ENCHUFES

SISTEMA DE CORRIENTE ALTERNA-MODIFICACION CANAL ALFALFAL


MOTOR

AC POWER SUPPLY-MODIFY CHANNEL ALFALFAL


ESCALA-SCALE: NOMBRE-NAME FIRMA-SIGNATURE FECHA-DATE
PROY. F.MUNOZ 15-03-2017
INDICADAS REV.S. E.SULLCA 15-03-2017
AS SPECIFIED REV.M.S P.MALDONADO 15-03-2017
LIDER J.MORENO 15-03-2017
APR. P.FURRER 15-03-2017
-DRAWING NUMBER: REV.-REV.

6305-EL-PLA-7011 A00