CHANGE

PERFORMANCE FOR 7 STAGES EFFICIENCY AS


NUMBER OF FOR NUMBER

TORRENT PUMPS
POINT OF STAGE
TYPE.......8.....HNM-I.......
FOLLOWS

LOWER 4 1
R.P.M......1760............. DEEP WELL VERTICAL TURBINE PUMPS
LOWER 1 3
CURVE SHEET No...8 - 0504 O.D. BOWLS 71/2" K=7,0
80 4

NPSH(m)
3
DETRITUS WITH NO SUCTION LIFT AND TEMPERATURE NOT TO EXCEED 30C .

75 2
HYDRAULIC PERFORMANCE : IS CONTINGENT ON WELL FURNISHING PUMP


WITH CLEAR FRESH NON-AERATED OR NON-GASEOUS WATER FREE FROM

70
65
TOTAL HEAD IN METERS

60

55

GREEK CONSTRUCTION
50

45

40

35
80
30
75

Efficiency(%)
25
70
20
65
15
60
10
55

N(PS)
5 20
15
10
0

0 10 20 30 40 50 60 70 80 90 100 110 120


CUBIC METERS PER HOUR
NO COLUMN LOSSES ARE EMMANUEL N. KAZIS S.A. IMPELLER BRONZE
INCLUDED P.O Box 52835 - GR 14610 - N. ERYTHREA - ATHENS - GREECE
SEMI - OPEN
TEL: (01)8161702 - (01)8161712 - FAX: (01) 8134765 - (01) 8161018
TOLERANCES ISO-2548 CLASS C E-Mail : kazis@hol.gr
STAINLESS STEEL SHAFT