16th Feb/2017 experiment work

Three models named 1,2 and 3 was measured

First all models moisture level in oil was measured


FDS for the whole models
PD Measure for all model

model oil FDS PD


C DF VOLTA Q(IEC) PD level
GE time
9.46 8.6 6 NO PD 12
1 9.54 20.63 0.413 13 6 NO PD 12
10.70
9.02 5.4 54 3min 150
2 8.83 20.88 0.401 4.5 12 NO PD 18
8.33
7.57 8.6 6 NO PD 12
3 7.37 20.62 0.419 13 6 NO PD 12
7.06

PD

Un
=8.6 Kv
The voltage was applied from 0 to 3 for 5min and raised to 13kv=

1.5 Un/ 3

For model 1

The apparent charges Q(IEC) was 6 as show in the table above


No PD at the all applied voltage measured
Level of charge was 12pC

For model 2

PD appeared at 5.4kv with the apparent charges Q(IEC) of 54pC (PD


inception)
3min after being subjected to the 5.4kv PD appeared
At 4.5 PD disappeared (extinction)
Level of charge at 4.5kv was 18Pc

For model 3

The apparent charges Q(IEC) was 6 Pc


No PD at all applied voltages to model measured
Level of charge was 12Pc

Ingress

All models were ingress moisture using humidifier.


Moistening time for each model was 10min
Model was covered airtight after ingress