ERA METAL BUILDING SYSTEMLTD

PROJECT:- FIELD FRESH

DESIGN CALCULATON FOR BASE PLATE DETAIL A

LOADING : - REFER COMPUTER OUTPUT FOR FORCES


LOADS
FORCE(KN) MOMENT(KN-m)
DL+LL+COL= 245.0 540.0
DL+WL = 71.0 241.0
PROVIDE BASE PLATE
LENGTH ( L ) 1000 mm Permissible Bending Stress= 250 Mpa
BREATH ( B ) 700 mm
MAX. CANTILIVER DIST. 90 mm
MIN. CANTILIVER DIST. 75 mm

Case 1 DL + LL+COL

BEARING PRESSURE UNDER BASE PLATE


= (P / A) +( 6 x M ) / ( BxL^2)
= 245 x 10^3 + 6 x 540 x 10^6
1000 X 700 700 X 1000^2
= 4.97 N/mm2 < 5 N/mm2 [SAFE]
Thickness required
= (4.97x3)(90^2-(75^2/4)
250
= 19.98 mm
Provide 20 mm thick base plate

CASE 2 DL + WL

BEARING PRESSURE UNDER BASE PLATE


= (P / A) +( 6 x M ) / ( BxL^2)
= 71 x 10^3 + 6 x 241 x 10^6
1000 X 700 700 X 1000^2
= 2.16 N/mm2 < 5 N/mm2 [SAFE]
Thickness required
= (2.16x3)(90^2-(75^2/4)
250
= 13.17 mm
Provide 20 mm thick base plate

Provide Base Plate 1000 x 700 x 20 mm