1. Sudhakar Dasari, a chartered engineer, certified that machinery mentioned in Invoice No. QB/EXP/09/2016-17 was inspected and found to meet technical specifications.
2. The machinery, a Qucon horizontal three pass fully wet back husk fired boiler, was certified to be brand new, having an evaporation capacity of 4000 kgs/hour at 10.5 cm sq (150 psi) with a feed and air temperature of 100 degrees C.
3. The certificate was being issued as an independent opinion to certify that the value of goods was correct as per the relevant proforma invoice, L/C authorization form, H
1. Sudhakar Dasari, a chartered engineer, certified that machinery mentioned in Invoice No. QB/EXP/09/2016-17 was inspected and found to meet technical specifications.
2. The machinery, a Qucon horizontal three pass fully wet back husk fired boiler, was certified to be brand new, having an evaporation capacity of 4000 kgs/hour at 10.5 cm sq (150 psi) with a feed and air temperature of 100 degrees C.
3. The certificate was being issued as an independent opinion to certify that the value of goods was correct as per the relevant proforma invoice, L/C authorization form, H
1. Sudhakar Dasari, a chartered engineer, certified that machinery mentioned in Invoice No. QB/EXP/09/2016-17 was inspected and found to meet technical specifications.
2. The machinery, a Qucon horizontal three pass fully wet back husk fired boiler, was certified to be brand new, having an evaporation capacity of 4000 kgs/hour at 10.5 cm sq (150 psi) with a feed and air temperature of 100 degrees C.
3. The certificate was being issued as an independent opinion to certify that the value of goods was correct as per the relevant proforma invoice, L/C authorization form, H
The undersigned, Sudhakar Dasari, an approved chartered engineer from
the Institution of Engineers (India), registration No. M 132329-O hereby certify that the machinery mentioned as per Invoice No. QB / EXP / 09 / 2016-17, Dt. 16.03.2017 of QUCON BOILERS PVT. LTD., PLOT 1/5B, I.D.A. NACHARAM, HYDERABAD, INDIA, in favour of EYE CONE INTERNATIONAL, 87, NEW ESKATON ROAD, HOMETOWN COMPLEX (SUITE 5B, 5TH FLOOR), DHAKA-1000, BANGLADESH, was inspected on 13.03.2017 and found in line with the technical specifications of the Proforma Invoice dated 12.03.2017, & the value of goods is correct as per L/C AUTHORISATION FORM No. JBL-53005, H.S. Code No. as per Proforma Invoice No. QB/EXP/EC/03/17, dated 12.03.2017 and Documentary Credit No. 3056- 17-01-0028, date 13.03.2017, Amendment dated 15.03.2017, and are HS CODE: 8402.12.00, BRAND NEW MACHINERY FOR AGRO BASED INDUSTRY - QUCON HORIZONTAL THREE PASS FULLY WET BACK HUSK FIRED BOILER, HAVING EVOPORATION CAPACITY OF 4000 KGS / HOUR 10.5 CM. SQ (150 PSI) F&A 100 DEG C ALONG WITH SUITABLE MOUNTINGS & FITTINGS AS PER OFFER MODEL : QBP-TFH-400 WITH COMPLETE SET.
This certificate is being issued as an independent opinion and without