Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Project 3 3/12/2017

Site 1 / Building 3 / Storey 1 / Room 4 / Room summary

Bed room

Height of room: 3.500 m, Reflection factors: Ceiling 70.3%, Walls 16.3%, Floor 34.2%, Light loss factor: 0.80

Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane 4 Perpendicular illuminance [lx] 167 (200) 91.4 216 0.55 0.42
Height: 1.000 m, Wall zone: 0.000 m

No. Quantity
1 16 RZB Rudolf Zimmermann, Bamberg GmbH 105 105

551174.002.12 Mondana-E Opalglas LED 90 90

Absolute photometry
Luminaire luminous flux: 600 lm 75 75

Power: 3.0 W 60
80
60

Luminous efficacy: 200.0 lm/W 120

Colorimetric data 45 160 45

1xLED Modul 837 3W: CCT 3991 K, CRI 80


240

30 15 0 15 30

cd 600 lm
C0 - C180 C90 - C270

Total lamp luminous flux: 9600 lm, Total luminaire luminous flux: 9600 lm, Total Load: 48.0 W, Luminous efficacy: 200.0 lm/W

Lighting power density: 2.16 W/m = 1.30 W/m/100 lx (Ground area 22.24 m)

Consumption: 130 kWh/a of maximum 800 kWh/a

Page 3
Project 3 3/12/2017

Site 1 / Building 3 / Storey 1 / Room 4 / Luminaire layout plan

Room 4

RZB Rudolf Zimmermann, Bamberg GmbH 551174.002.12 Mondana-E Opalglas LED

No. X [m] Y [m] Mounting height [m]


1 3.500 0.695 3.400
2 3.500 2.085 3.400
3 3.500 3.475 3.400
4 3.500 4.865 3.400
5 2.500 0.695 3.400
6 2.500 2.085 3.400
7 0.500 4.865 3.400
8 0.500 3.475 3.400
9 0.500 2.085 3.400
10 0.500 0.695 3.400
11 1.500 4.865 3.400
12 1.500 3.475 3.400
13 1.500 2.085 3.400
14 1.500 0.695 3.400
15 2.500 4.865 3.400
16 2.500 3.475 3.400