Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142 Paper received: 19.11.

2009
UDC 621.785 Paper accepted: 19.01.2010

Vegetable Oil Quenchants: Calculation and Comparison of


The Cooling Properties of a Series of Vegetable Oils
Nikolai Ivanovich Kobasko1 - Ester Carvalho de Souza2 -
Lauralice de Compos Franceschini Canale2,*- George Edward Totten3
1
Intensive Quenching Technologies, USA
2
Universidade de So Paulo, Escola de Engenharia de So Carlos, Brazil
3
Portland State University, Department of Mechanical and Materials Engineering, USA

The compositions of canola, soybean, corn, cottonseed and sunflower oils suggest that they exhibit
substantially different propensity for oxidation following the order of: Canola < corn < cottonseed <
sunflower soybean.
These data suggest that any of the vegetable oils evaluated could be blended with minimal impact
on viscosity although compositional differences would surely affect oxidative stability. Cooling curve
analysis showed that similar cooling profiles were obtained for different vegetable oils. Interestingly, no
film boiling or transition nucleate boiling was observed with any of the vegetable oils and heat transfer
occurs only by pure nucleate boiling and convection. High-temperature cooling properties of vegetable
oils are considerable faster than those observed for petroleum oil-based quenchants.
2010 Journal of Mechanical Engineering. All rights reserved.
Keywords: quenchant, heat transfer, vegetable oil, cooling curve, oxidation, cooling curves

0 INTRODUCTION significantly faster for castor oil (1.8 seconds)


than for soybean oil (1.42 seconds) using a JIS K
There have been various investigations on 2242 silver probe test which utilizes a 10 mm dia
the use of vegetable oils and (animal oils) as x 30 mm cylindrical silver probe with a surface
quenchants. One of the earliest studies involving thermocouple [3].
cooling curve and heat transfer analysis of Fujimura and Sato followed this work in
quenching properties was conducted by Rose in 1963 by examining the quenching performance of
1940 with rapeseed oil [1]. The cooling curve the vegetable oils reported by Tagaya and Tamura
results obtained showed that the heat transfer and also added castor oil to their study in addition
coefficients for rapeseed oil were 1744 to 2092 to ethyl esters of oleic, palmitic and stearic acid
W/m2K in the transition nucleate boiling region, versus different petroleum oil quenchants and
2906 to 3486 W/m2K in the nucleate boiling concluded that the performance of soybean and
region and 464 to 697 W/m2K in the convective rapeseed oil were essentially equivalent [4].
cooling region versus 697 to 1394 W/m2K for Cooling curve analysis was performed according
film boiling, 2325 to 3486 W/m2K nucleate to JIS K 2242 [3]. Quenching performance of the
boiling and 233 to 580 W/m2K for convective ethyl esters were also equivalent to each other and
cooling for a so-called petroleum heavy oil. exhibited greater quench severity than the
The higher cooling rates for rapeseed oil were vegetable oils. Castor oil, however, was found to
attributed to the relatively poor stability of the be thermally unstable. The quenching
vapor blanket formed by the rapeseed oil [1]. performance of castor oil was also studied by
In 1953, Tagaya and Tamura compared Farah, et. al. [5] and the thermal instability of this
the quench severity of different vegetable oils oil was subsequently confirmed [6].
including soybean, rapeseed and castor oils with Currently, the most commonly cited
mineral oils and fish/animal oils with respect to vegetable oil basestocks used for quenchant
fluid source, viscosity and oxidative stability for formulation in the USA are based on canola oil
various naturally derived fluids [2]. These data [7] and [8], and soybean oil [9]. Recently, a
showed that although the Grossmann quench crambe oil based fluid has been reported as a
severity factors were comparable for both castor potential quenchant [10]. Przylecka and Gestwa
oil (H = 0.199) and soybean oil (H = 0.2), the
cooling times from 700 to 300C were

*
Corr. Author's Address: Universidade de So Paulo, Escola de Engenharia de So Carlos,
131
So Carlos, Brazil, lfcanale@sc.usp.br
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

have reported the use of a vegetable oil-based showed that vegetable oils exhibited faster
quenchant for hardening carburized steels [11]1. cooling rates than the mineral oil used as a
Prabhu studied the heat flux properties of reference.
palm oil [12] and extensive heat transfer and The objective of this study was to
wetting studies of coconut, sunflower, groundnut, compare the quenching performance of vegetable
palm and castor oils [12] to [15]. With the oils most commonly considered as potential
exception of palm oil, these vegetable oils are not basestocks for quenchant formulation in North
commonly considered as basestocks for and South America. Furthermore, for the first
quenchants in North and South America. time, quenching performance will be considered
Prabhus cooling curve analysis work was in conjunction with the compositional variation of
conducted using a 12 mm dia x 60 mm cylindrical the vegetable oils being studied.
Type 304 stainless steel probe. Interestingly, with
the exception of castor oil, relatively little 1 EXPERIMENTAL
difference in surface wetting properties were
obtained and quench severities comparable to a The vegetable oils used for this work were
conventional, non-accelerated mineral oil were purchased at the local market in Sao Carlos,
observed. Brazil and were characterized and used in the as-
Totten, et. al. reported the results of purchased condition. The vegetable oils that were
cooling curve, hardening performance, heat purchased included: canola oil, cottonseed oil,
transfer, and rewettability characterization studies corn oil, sunflower oil, and soybean oil
conducted with crude and partially hydrogenated (commercially designated as pure soybean oil).
and winterized soybean oils [16] provided by Quenching performance of these oils was
Honary [17]. Because of the strong influence of compared to two commercially available
the test specimen surface on the wetting behavior quenching oils: Micro Temp 157 (a conventional
(and therefore on the quenching behavior), "slow" oil) and Micro Temp 153B (an accelerated
unalloyed (Ck 45) steel probes were used. This "fast" oil).2
work provided a simultaneous examination of the Viscosity was measured at 40 and 100C
martensitic transformation with local differences, according to: ASTM D445 - 06 Standard Test.
and dependencies on the rewetting time (and The viscosity index was determined from the
dependencies on the metallurgical condition of kinematic viscosities at 40 and 100C according
the steel). to ASTM D2270 - 04.
Cooling curve analyses showed that The fatty acid ester composition of the
immersion quenching was primarily influenced vegetable oil was determined by a gas
by the sequence of the cooling phases and chromatographic analysis procedure using methyl
different heat transfer rates. Heat transfer on the ester derivatives of the different vegetable oils
specimen surface was primarily determined by prepared as described previously [18] and [19]
the rewetting conditions and depended on the using a Model CG-17-A Shimadzu gas
cooling characteristics of the quenching medium chromatograph equipped with a flame ionization
used, bath temperatures, and agitation rates. The detector (FID) set to 300C and a "split" injection
soybean oils investigated showed no significant system ratio of 1:30 at 280C. An injection
differences in cooling behavior and rewetting volume of 1 L was used. N2 was used as an
conditions on the test specimen surface and auxiliary gas and average linear H2 gas flow rate
cooling rates were similar. A comparison of the was 35 cm/s. The column used was LM-100
cooling time-temperature and cooling rate curves (100% polyethylene glycol) with dimensions 25m
x 0.25 mm i.d. x 0.25 m. The temperature of the
1
The specific product reported by Prezylecka and
Gestwa was a commercial product designated as
2
Bioquench 700 manufactured by Houghton The Micro Temp 157 and Micro Temp 153B
International. In the USA, this product is based on were obtained from Micro Quimica Ind. Com.
canola oil (see References 17 and 56). However, Ltda., Rua Projetada 225, Jardim Unio, 09970-
in Poland, this product was reportedly based on 000 Diadema - SP, Brazil: www.micro-
rapeseed oil. quimica.ind.br

132 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.


Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

Fig. 1. Schematic illustration of the probe used for cooling curve analysis in ASTM D6200

column was maintained isothermally at 190C cooling and the temperature where this occurs.
for 25 minutes. Generally, it would be desirable to maximize
The cooling curves were obtained in the CRmax and minimize TCRmax. The rates of
non-agitated condition at 60C according to cooling at temperatures such as 200 and 300C,
ASTM D6200 which utilizes a 12.5 mm dia x parameters VII and IX, are also determined
60 mm INCONEL 600 cylindrical probe with a since they are related to the potential for steel
Type K thermocouple inserted to the geometric cracking and distortion. To minimize these
center. After heating the probe in a furnace to problems, it is desirable to minimize cooling
850C, it was then manually and rapidly rates in this region. Parameters VIII and X are
immersed into 2000 mL of the oil to be tested related to region of the pearlite transformation.
which was contained in a tall-form stainless It is generally desirable to minimize these
steel beaker. The probe temperature and cooling parameters.
times are recorded at selected time intervals to
establish a cooling temperature versus time
curve. From these curves the critical parameters
are obtained, as illustrated in Fig. 2 [20], for
quenchant characterization [21].
I tA-B [sec],
II TA-B [C],
III DHmin [C/sec],
IV CR700 [C/sec],
V CRmax [C/sec],
VI TCRmax [C],
VII I CR300 [C/sec],
VIII CR200 [C/sec],
IX t300 [sec]
X t200 [sec] Fig. 2. Critical cooling curve parameters
Parameters I to III shown graphically in
Fig. 2 are related to the full-film boiling (vapor 1.1 Calculation of Effective Heat Transfer
blanket cooling) to nucleate boiling transition Coefficients
time and temperature and the cooling rate at
critical temperatures. Cooling rate at 700C, Most conventional cooling processes
parameter IV, is measured since it is usually involving vaporizable quenchants possess four
desirable to maximize this cooling rate to avoid cooling mechanisms: 1) shock boiling, 2) film
the steel pearlite transformation region. boiling, 3) nucleate boiling and 4) convection
Parameters V and VI are the maximum rate of cooling processes. Since standard probe provides

Vegetable Oil Quenchants: Calculation and Comparison of The Cooling Properties of a Series of Vegetable Oils 133
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

cooling rate and temperature vs. time at the core In regular condition Eq. (5) can be
of probe, we can only evaluate average effective rewritten as:
heat transfer coefficients which are widely used T Tm
in heat treating industry. During quenching, the = A0 U 0 exp ( mt ) . (7)
T 0 Tm
heat transfer coefficient is dependent on: surface
temperature of the steel part, mass and flow The value "m" from Eq. (7) is measured
velocity of the quenchant. The variation of the by using two points on the temperature-time
heat transfer coefficient during film boiling is curve (cooling curve) that correspond to time t1
sufficiently small to permit the use of average and time t2 i.e.:
values (FB). During nucleate boiling and T 1 Tm
convections also average effective heat transfer ln = ln( A0U 0) mt1 , (8)
T 0 Tm
coefficients can be found. In this paper the heat
transfer coefficients were calculated according T 2 Tm
ln = ln( A0U 0) mt 2 ,
to the theory of regular conditions. [22] to [24]. T 0 Tm
The calculation procedure has been discussed or:
previously in References [15] and [25] and is
ln (T 1 Tm ) ln (T 2 Tm )
outlined below. m= . (9)
The equation governing heat t 2 t1
conduction for one dimensional heat transfer, as Using the value of m, the Kondratjev
would be expected from the 12.5 mm dia x 60 number (Kn) is calculated from:
mm cylindrical standard probe illustrated in Fig. m a
Kn = , m = , (10)
1, is: m K
1 T where K is the Kondratjev form factor (shape
= div( grad T ) (1) factor). For a cylinder, K is:
a t
where T [K] is temperature at the center of the R2
K= . (11)
probe, t is time [s], a [m2/s] is the thermal 5.783
diffusivity of the metal. Since the standard probe shown in Fig. 1
The boundary and initial conditions are: is used to obtain temperature-time and cooling
T rate - time data for the cooling process, then Eq.
+ (T Tm ) r = R = 0 (2) (5) is rewritten as:
r
w = m(T Tm ) (12)
T ( r ,0) = T0 (3)
w
or m = . (13)
T T Tm
=0 (4)
r where w is the cooling rate. Eq. (9) or Eq. (13)
where [W/mK] is the heat conductivity of the may be used to determine the Kondratjev
metal, [W/m2K] is the heat transfer coefficient, number Kn from Eq. (10).
T [K] is the temperature at the center of the The generalized Biot number and further
probe, Tm [K] is the medium temperature, R [m] average effective heat transfer coefficient during
is radius. The general solution for these quenching are evaluated from the universal
equations is: correlation (14):
T Tm Biv
Kn =
T 0 Tm
= A U exp( m t )
i=0
i i i (5)
(Biv + 1.437 Biv + 1
2
)
0.5
. (14)

where: mo < m1 < m2 < (6) Assume that generalized Biot number
where: Ai is temperature amplitudes, Ui is the from the experiment is equal to value C, i.e.
functions of the coordinates, mi [s-1] is a value Biv = C
that depends on the thermal properties of a S (15)
material and cooling capacity of the quenchant, where : Biv = K
V
t [s] is cooling time.

134 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.


Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

where: S is the surface area of the probe, V is where for standard probe K = 6.7510-6 m2.
the volume of the probe, K is Kondratiev form According to Eq. (10) Kondratjev
factor. number Kn = 0.128/0.726 = 0.176. From the
The heat transfer coefficient can be correlation (14) follows that generalized Biot
evaluated as: number BiV = 0.20. Using Eq. (16), the average
C V C R heat transfer coefficient is:
= = . (16)
KS 2K
Two examples are provided which 0.20 20.7W/mK 6.25m 103 W
= 6
= 1916 2 .
illustrate the use of these equations. 2 6.75 10 m 2
mK
The average effective heat transfer
Example 1 coefficient within the temperature range 450 to
700C is equal to:
Assume that the core cooling rate of the 2278 + 1916 W
standard probe when quenching in oil (60C) at = = 2097 2 .
2 m K
700C is 90C /s. Thermal diffusivity of Inconel
600 at 700C is equal to 5.610-6 m2/s and the 3 RESULTS AND DISCUSSION
thermal conductivity is equal to 25.9 W/mK.
The average heat transfer coefficient at this 3.1 Compositional Analysis
temperature can be calculated using Eq. (16).
First, the value of m is calculated from Eq. (13), The composition of the different
i.e. vegetable oils used for the work reported here
was determined by methanolysis of the
90o C / s
m= = 0.14 s 1 . vegetable oil. The components were quantified
700 C 60 C
o o
by gas chromatographic analysis and the results
Then calculate: obtained are shown in Table 1. Substantial
a 5.6 106 m 2 / s variation in the compositions of these vegetable
m = = = 0.83 s 1 ,
K 6.75 106 m 2 oils is evident.
According to Eq. (10), the Kondratjev The stability of vegetable oils to
number Kn = 0.14/0.83 = 0.189. From the oxidation depends not only on the degree of
correlation (14) it follows that the generalized unsaturation (double bond content) but also on
Biot number BiV = 0.19. Using Eq. (16), the the degree of double bond conjugation. For
average heat transfer coefficient is calculated example, linoleic acid is especially reactive
from: relative to oleic acid and linolenic acid is more
reactive than linoleic acid. The most stable form
0.19 25.9W/mK 6.25m 10 3 W
= 6
= 2278 2 of the fatty acid components is when there are
2 6.75 10 m 2
m K no double bonds present (completely saturated)
such as stearic acid and palmitic acid. Schneider
Example 2
has reported that the relative rate of oxidation
increases as the number of double bonds in
Assume that the core cooling rate of the
conjugation with each other [26]. The
standard probe when quenching in oil (60C) at
following approximate relative oxidation rates
450C is 50C /s. Thermal diffusivity of Inconel
were reported: stearic (1) > oleic (10) > linoleic
600 at 450C is equal to 4.910-6 m2/s and heat
(100) > linolenic (200). Similar results have
conductivity is equal to 20.7 W/mK. There is
been reported by Kodali [27]. For this work, it is
need to calculate average heat transfer
assumed that the relative rate of oxidation of
coefficient using Eq. (16). As with Example 1,
stearic acid is approximately equivalent to
the value of m is calculated using Eq. (13):
palmitic acid which is reasonable since both are
50o C/s staturated (no hydrocarbon double bonds) with
m= = 0.128 s -1 .
450o C 60o C very similar molecular weights.
Then the value of m is calculated: It is also known that the overall reaction
a 4.9 106 m 2 /s rate of a process is the sum of the various
m = = = 0.726 s -1 ,
K 6.75 106 m 2

Vegetable Oil Quenchants: Calculation and Comparison of the Cooling Properties of a Series of Vegetable Oils 135
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

Table 1. Composition percentage of fatty acids present in samples of vegetable oils1


Relative Reactivity
Palmitic Stearic Oleic Linoleic Linolenic
Vegetable Oil to Oxidative
Acid Acid Acid Acid Acid
Degradation2
Corn 12.0 2.0 35.0 48.0 0.8 1.43
Soybean 10.5 2.7 20.8 58.6 5.0 1.90
Canola 4.5 2.1 65.4 20.2 5.2 1
Cottonseed 22.0 2.0 17.0 56.7 0.4 1.60
Sunflower 7.0 3.2 19.4 66.0 0.5 1.85
1. Percentages may not add up to 100% due to presence of other minor constituents not listed.
2. Calculated from the stearic acid, oleic acid, linoleic acid and linolenic acids using the reported
relative reactivity to oxidation of: 1/10/100/200 respectively.

individual reaction rates of a process. Since particular vegetable oils being evaluated would
vegetable oils possess different fatty acid exhibit the relative stability to oxidation of:
components, each with a particular and different anola > corn > cottonseed > sunflower
oxidation rate, the overall oxidation rate is soybean.
approximately equivalent to the sum of the Interestingly, while soybean oil is one of
oxidation rates of the fractional composition of the vegetable oils of greatest interest for
stearic (and palmitic), oleic, linoleic and quenchant formulation, it is almost twice the
linolenic acids. This is only approximate since potential for oxidation than canola oil, the most
there are other unidentified unsaturated fatty stable oil in this study.
acid components in very low concentrations.
This is the reason why different vegetable oils 2.2 Kinematic Viscosity Properties
exhibit different inherent properties such as
smoke and flash points, for example or why one In addition to oxidative stability, perhaps
vegetable oil may be favored for an application, the most important physical property of any
such as deep frying, relative to another. potential quenchant, including vegetable oils, is
An approximation of the relative the viscosity temperature relationship since it
propensity for oxidation of the different is perhaps the single greatest factor impacting
vegetable oils with respect to their composition overall heat transfer performance during
was determined from the fatty acid composition quenching. For vegetable oils, viscosity
data obtained by gas chromatography and the typically increases with fatty acid ester chain
relative reactivity for oxidation reported by length and decreases with the amount of
Kodali [27]. The first step in this assessment is unsaturation in the fatty acid ester alkyl chain
to determine the molar quantities of each [28]. Fasina, et. al. studied the viscosity-
component in a given quantity of the vegetable temperature behavior of 12 vegetable oils and
oil. The molar quantities of each component are found them all to exhibit an exponential
then multiplied by the relative reactivity for viscosity increase with decreasing temperature
oxidation. These component oxidation [29]. In this work, the viscosity-temperature
propensities are summed and normalized to properties were determined from kinematic
provide a total potential for oxidation ratio of viscosity measurements (ASTM D445) and
each oil shown in Table 1. These data show that calculation of the viscosity index (VI) according
soybean oil would exhibit one of the worst to ASTM D2270 and the data obtained for both
potentials for oxidative instability and canola oil the vegetable oils and the two petroleum oil
would be the best of those vegetable oils shown quenchants also being studied are shown in
here. Based on the compositions of the Table 2.
vegetable oils with respect to stearic acid, oleic The heat transfer properties of a
acid, linoleic acid and linolenic acid and the quenchant is exponentially dependent on fluid
relative oxidation rates of: 1/10/100/200 viscosity. The viscosities of the different
respectively, the data in Table 1 show that the vegetable oils used in this study were

136 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.


Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

determined and while they are somewhat comparison; Micro Temp 157, a conventional,
different from each other, they are comparable unaccelerated petroleum oil, and Micro Temp
and reasonably similar to the two petroleum oil 153B, an accelerated petroleum oil.
quenchants used for comparative evaluation in During the course of these investigations,
this work and included a conventional quench it was readily apparent that vegetable oils do not
oil (Micro Temp 157) and an accelerated boil under atmospheric conditions and the
quench oil (Micro Temp 153B). interfacial temperatures encountered during
The rate at which the viscosity of an oil quenching. This is important because there is no
will change as the temperature is increased or full-film boiling or nucleate boiling involved.
decreased is defined as the viscosity index (VI) Although vegetable-oil based quenchants have
and determined by measuring the viscosities of been reported before, the fact that they only
an oil at 40 and 100C and using the tables or exhibit convective heat transfer and no full-film
equations provided in ASTM D2270. The boiling or nucleate boiling is not well-known.
sensitivity of the change in viscosity with This performance should be compared to
respect to temperature decreases as the VI value petroleum derived quenchants since, as a class,
increases. In all cases, the VI values shown for since they do exhibit full-film boiling and
the vegetable oils in Table 2 were nucleate boiling in addition to convective heat
approximately double those values obtained for transfer. These differences are apparent when
the petroleum oil quenchants. Which means that viewing the cooling curves obtained for the
the viscosity of the petroleum oil is much more vegetable oils in this study with the
sensitive to variations in temperature than any conventional oil Microtemp 157 and accelerated
of the vegetable oils used in this study. (Both of quench oil, Microtemp 153B shown in Fig. 3.
the petroleum oil quenchants used in this study Petroleum oil quenchants are also often
were formulated from a paraffinic basestock and typified by exhibiting relatively little difference
the higher viscosity exhibited by Micro Temp in cooling behavior with temperature change.
153B relative to Micro Temp 157 is due to the This is usually explained by the smaller
presence of cooling rate accelerating additive(s) difference in T between the metal surface and
in the quench oil.) the bulk temperature of the oil which is
approximately counterbalanced by the lower
2.3 Quenching Performance fluid viscosity at the higher bulk fluid
temperature.
Quenching performance of each of the The data in Table 3 shows that the
vegetable oils was evaluated by cooling curve maximum cooling rate CRmax and the
analysis according to ASTM D6200 which is temperature where this occurs TCRmax does not
conducted under unagitated conditions. Since vary significantly between different vegetable
the objective is to use a vegetable oil as a oils. This conclusion is based on the reported
replacement for a petroleum oil, two different Precision and Bias for ASTM D6200 where the
petroleum oil quenchants were used for

Table 2. Summary of viscosity properties determined for vegetable oils and petroleum oil based
quenchants used in this work.
Viscosity and Vegetable Oil Petroleum Oil
Viscosity Quenchant
Index Slow Fast
Micro
Canola Corn Cottonseed Soybean Sunflower 157 153 B
Viscosity
(cSt at 40C) 34.92 33.51 33.86 31.49 33.21 29.0 40.0
Viscosity
(cSt at 100C 7.91 7.70 7.75 7.51 7.78 5.0 6.65
Viscosity
Index 209 211 211 220 218 96 121

Vegetable Oil Quenchants: Calculation and Comparison of the Cooling Properties of a Series of Vegetable Oils 137
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

maximum cooling rate variation obtained for a transfer at 700C than those obtained for the
reference oil in a round-robin study was 47 to vegetable oils but the heat transfer properties
53C/s and the temperature at the maximum cooling were comparable at the lower temperature of
rate varied in this study between 490 to 530C. 450C. On average, the heat transfer coefficients
Overall, the cooling properties of the were somewhat lower for the petroleum oil-based
vegetable oils were comparable to each other and quenchants as were the Grossman quench severity
it is notable that only convective cooling was values confirming that they exhibit lower quench
obtained with no extended vapor blanket cooling severity than would be expected for a vegetable
(film-boiling). This cooling profile shows that oil.
vegetable oils would not require a cooling rate In his study of vegetable oil quenchants
accelerator and would be acceptable even for Rose observed that the cooling process was very
difficult to harden, crack-sensitive carbon steels. fast initially but it was not recognized that the
The cooling rates, however, were somewhat cooling occurred by convection without film
faster, especially in the critical martensitic boiling or nucleate boiling [1]. Tamura studied
temperature transition range (300C) than the different vegetable and animal oils (triglycerides)
petroleum oil quenchants evaluated suggesting and showed that the quench severity was
that they may not be as desirable for higher alloy, somewhat greater for triglycerides in general than
crack sensitive steels. However, this must be for petroleum oil quenchants. For example,
confirmed experimentally. Tamura obtained Grossman H-values of 0.2,
The Micro Temp 157 and 153B did 0.199, 0.2 and 0.199 for soybean, fin whate,
behave as expected. The fast oil, Micro Temp sperm skin and rapeseed oils respectively and
153B exhibited shorter film-boiling times and 0.142 and 0.136 for conventional petroleum oils
both oils exhibited similar lower temperature designated as "A" and "B" respectively [2].
cooling rates, although the Micro Temp 153B was Prabhu, et. al. studied the quenching properties of
somewhat slower which was probably due to the a number of vegetable oils including: sunflower,
higher bulk fluid viscosity. coconut, palm, and groundnut (peanut) oils and
The comparison of the heat transfer compared the quench severities obtained with a
coefficients and Grossman quench severity values petroleum oil. They reported that the quench
for the vegetable oils evaluated also shows that all severities of these oils followed a decreasing
of the vegetable oils exhibited comparable heat order [15]:
transfer performance in the hardening
temperature range of 700 to 450C. Interestingly, Sunflower oil > Coconut oil > Palm oil >
both the unaccelerated and accelerated petroleum Petroleum oil > Groundnut oil.
oils evaluated exhibited substantially lower heat

Fig. 3. Cooling curves data at 60C bath temperature. a) time - temperature, b) cooling rate -
temperature

138 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.


Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

Table 3. Tabulation of cooling parameters obtained by ASTM D6200 at a quench bath temperature of
60C and with no agitation
Petroleum Oil
Vegetable Oil Quenchant
Cooling Slow Fast Oil
Parameters at Oil
60C Canola Corn Cottonseed Soybean Sunflower Micro Micro
Temp Temp
157 153 B
tA-B [s] 3.8 3.3 3.3 3.8 3.8 11.0 8.5
TA-B[C] 830.0 837.7 835.0 826.5 830 652.3 703.4
CRDH min [C/s] 19.4 14.6 20.0 20.6 16.3 20.7 29.2
CRmax [C/s] 90.9 81.7 79.5 81.2 87.6 71.7 97.3
TCRmax [C] 686.0 668.4 648.9 673.6 677.2 550.8 598.8
CR700 [C/s] 86.0 77.0 75.0 75.0 86.0 25.0 29.0
CR300 [C/s] 11.4 12.4 14.0 11.4 11.4 4.9 6.0
CR200 [C/s] 2.7 2.7 2.1 2.7 2.2 2.4 1.2
t300C [s] 15.3 15.0 15.5 15.8 15.3 29.3 24.0
t200C [s] 34.0 32.3 34.0 35.8 33.5 52.0 48.8

Heat transfer properties


Heat transfer
coefficient 2455 2160 2190 2040 2455 587 705
[W/m2K) at
700 C

Heat transfer
coefficient 1810 1815 1970 1810 1980 1790 2060
[W/m2K) at
450 C

Average value 2132 1842 2080 1920 2212 1188 1382


[W/m2K)

Grossman H- 0.198 0.171 0.193 0.178 0.205 0.111 0.124


value

With the exception of groundnut oil, the were nearly identical to those reported by
other vegetable oils shown here exhibited Tamura.
greater quench severities than the petroleum oil
reference evaluated. The relatively low quench 4 CONCLUSIONS
severity of groundnut oil compared to the other
oils shown was at least partially attributable to Five vegetable oils were obtained from a
low activation energies for spreading (poor commercial source and their compositions were
wetting) [12]. determined by gas chromatography. Based on
Although the series of vegetable oils the compositions of the vegetable oils with
used for this work are different than those of respect to stearic acid, oleic acid, linoleic acid
other studies reported earlier, the quenching and linolenic acid the particular vegetable oils
properties are consistent with those reported being evaluated would exhibit the relative
earlier. In fact, the Grossmann quench severities stability to oxidation of:

Vegetable Oil Quenchants: Calculation and Comparison of the Cooling Properties of a Series of Vegetable Oils 139
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

Canola < corn < cottonseed < sunflower of the different vegetable oils was observed.
soybean. When the cooling curve data of the different
Interestingly, while soybean oil is one of vegetable oils is compared to the petroleum
the vegetable oils of greatest interest for derived Microtemp 157 and Microtemp 153B, it
quenchant formulation, it has almost twice the is evident that all of the vegetable oils do not
potential for oxidation than canola oil, the most exhibit film boiling or transition nucleate
stable oil in this study. It is recognized that this boiling. In fact, although Microtemp 153B, the
can only provide a rough estimate of vegetable accelerated quench oil exhibited significantly
oil stability since other factors not included in reduced film-boiling stability relative to
this simplified computation also affect oxidative Microtemp 157, the conventional quench oil,
stability of vegetables oils such as: peroxide its high-temperature cooling performance was
content, presence of free acids and water, metal not as "fast" as the vegetable oils. These data are
contamination and other affects. Nevertheless, reasonable since vegetable oils do not boil due
this calculation does show the dependence of to their extraordinarily high boiling point.
the oxidative stability of vegetable oils on Instead, they would degrade before boiling
compositional structure and furthermore, these under atmospheric conditions. The cooling
results are comparable to results using properties obtained suggest that vegetable oils
pressurized differential scanning calorimetry would be especially suitable for quenching low-
[30]. hardenability steels such as carbon steels.
Viscosities at 40 and 100C by ASTM
D445 and the viscosity index by ASTM D2270 5 ACKNOWLEDGEMENTS
were determined for the vegetable oils and two
petroleum oil quenchants: Microtemp 157 [a The authors acknowledge their
conventional slow oil) and Microtemp 153B [an appreciation to CAPES [Coordenao de
accelerated or fast oil). Although the kinematic Aperfeioamento de Pessoal de Nvel Superior)
viscosities of different vegetable and petroleum for the financial support of this work and to
oils at 40C were not identical, they were MSc Renata Leal for performing the physical
similar. However, the VI values for different property analysis reported here.
vegetable oils were very close and varied
between 209 to 220 and were all much higher 6 REFERENCES
than the VI values obtained for Microtemp 157
[96) and Microtemp 153B [121). These data [1] Rose, A. (1940) The cooling capacity of the
indicate that the viscosity variation of these quenchants, Archiv. fr das
vegetable oils are substantially less sensitive to Eisenhttenwesen, vol. 13, no. 8, p. 345-
temperature variation than the parrafinic oil 354.
based Microtemp 157 and Microtemp 153B. [2] Tagaya, M., Tamura, I. (1954) Studies on
Although these data suggest that any of the the quenching media 3rd report, The cooling
vegetable oils evaluated could be blended with ability of oils, Technology Report, Osaka
minimal impact on viscosity, the oxidative University, vol. 4, p. 305-319.
stability would surely be substantially impacted. [3] JIS K 2242:1980, Japanese Industrial
Cooling curve analysis was performed on Standard Heat Treating Oil.
these vegetable oils at 60C under non-agitated [4] Fujimura, Y., Sato, T. (1963) The
conditions according to ASTM D6200. These composition of quenching oil and
results were compared with cooling curves quenching effects, The Iron and Steel
obtained for Microtemp 157, a conventional, Institute of Japan (ISIJ), vol. 49, p. 1008-
unaccelerated petroleum oil, and Microtemp 1015.
153B, an accelerated petroleum oil under the [5] Farah, A.F., Crnkovic, O.R., Canale,
same conditions. The results showed that the L.C.F. (1999) Castor oil: Studies for heat
high-temperature cooling profiles were very treatment applications, 19th Heat Treating
similar for the different vegetable oils and at Society Conference Proceedings, ASM
lower probe temperatures and a somewhat International, Materials Park, OH, p. 251-
greater discrimination of the cooling properties 254.

140 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.


Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

[6] Canale, L.C.F., Fernandes, M.R., [16] Totten, G.E., Tensi, H.M., Lanier, K.
Agustinho, S.C.M., Totten, G.E., Farah, (1999) Performance of vegetable oils as a
A.F. (2005) Oxidation of vegetable oils and cooling medium in comparison to a
its impact on quenching performance, Int. J. standard mineral oil, J. Mat. Eng. and Perf.,
Materials and Product Technology, vol. 24, vol. 8, no. 4, p. 409-416.
no. 1-4, p. 101-125. [17] Honary, L.A.T. (1999) Soybean based
[7] Brennan, R.J., Faulkner, C.H., Massuda, D. hydraulic fluid, U.S. Patent 5,972,855.
(1997) A quenchant based on canola oil, [18] Christie, W.W. (1989) Gas
Advanced Materials & Processes, vol. 152, Chromatography and lipids: a practical
no. 2, p. 32S 32U. guide, The Oily Press, Bridgwater, p. 11-
[8] Brennan, R.J., Faulkner, C.H. (1996) A 27, 69.
new quenching alternative, Conf. Proceed. [19] Neto, P.R. (2000) Biofuel production
2nd International Conference on Quenching alternative to diesel oil obtained by the
and Control of Distortion., ASM transesterification of the soybean oils used
International, Materials, p. 423-428. to food, Qumica Nova, So Paulo, vol. 23,
[9] Honary, L.A.T. (1996) Performance of no. 4, p. 531-537. (in Portuguese)
vegetable oils as a heat treat quenchant, [20] Liscic, B., Tensi, H.M., Totten, G.E.,
Conf. Proceed. 2nd International Webster, G.M. (2003) Non-lubricating
Conference on Quenching and Control of process fluids: Steel quenching technology,
Distortion, ASM International, Materials Fuels and Lubricants Handbook
OH, p. 595-605. Technology,Properties, Performance and
[10] Lazerri, L., De Mattei, F. Bucelli, F., Testing, ASTM International, West
Palmieri, S. (1999) Crambe oil: A Conshocken, PA., p. 587-634.
potentially new hydraulic oil and [21] Tensi, H.M., Steffen, E. (1985) Measuring
quenchant, Ind. Lubr. Tribol., vol. 49, no. 2, of the quenching effect of liquid hardening
p. 71-77. agents on the basis of synthetics, Steel
[11] Przylecka, M., Gestwa, W. (2007) The Research, vol. 56, p. 489-496.
influence of Bio-Quench 700EU: [22] Kobasko, N.I., Totten, G.E. (2004) Design
Conditions on hardness of carburized of the industrial quenching processes,
components, Inynieria Materiaowa, vol. Transactions of Materials and Heat
XXVIII, no. 3-4, p. 715-719. Treatment, vol. 25, no 5, p. 527-530.
[12] Prabhu, K.N., Fernandes, P. (2007) [23] Aronov, M.A., Kobasko, N.I., Powell, J.A.,
Determination of wetting behavior, spread Hernandez-Morales, J.B. (2008)
activation energy, and quench severity of Correlation between Grossmann H Factor
bioquenchants, Metallurgical and Materials and generalized biot number BiV , Proc. of
Transactions B, vol. 38, no. 4, p. 631-640. the 5th WSEAS Int. Conf. on Heat and
[13] Prabhu, K.N., Prasad, A. (2003) Mass Transfer (HMT'08).
Metal/quenchant interfacial heat flux [24] Kobasko, N. (2008) Hardness and structure
transients during quenching in conventional prediction at the core of any steel part using
quench media and vegetable oils, J. Mat. Jominy standard test, Proc. of the 5th
Eng. and Perf., v. 12, no. 1, p. 48-55. WSEAS Int. Conf. on Heat and Mass
[14] Prabhu, K.N., Fernandes, P. (2007) Effect Transfer (HMT'08).
of surface roughness on metal/quenchant [25] Canale, L.C.F., Kobasko, N.I., Totten, G.E.
interfacial heat transfer and evolution of (2007) Intensive Quenching: Part 1 What
microstructure, Materials and Design, vol. is it?, International Heat Treatment and
28, p. 544-550. Surface Engineering, vol. 1, no. 1, p. 30-33.
[15] Fernandes, P., Prabhu, K.N. (2008) [26] Schneider, M. (2002) Government Industry
Comparative study of heat transfer and Forum on Non-food Uses of Crops
wetting behaviour of conventional and [GIFNFG 7/7) Case Study Plant Oil
bioquenchants for industrial heat treatment, Based Lubricants in Total Loss and
International Journal of Heat and Mass Potential Loss Applications, Final Report,
Transfer, vol. 51, no. 3-4, p. 526-538. University of York, England.

Vegetable Oil Quenchants: Calculation and Comparison of the Cooling Properties of a Series of Vegetable Oils 141
Strojniki vestnik - Journal of Mechanical Engineering 56(2010)2, 131-142

[27] Kodali, D.R. (2002) High Performance vegetable oils from fatty acid composition,
Ester Lubricants from Natural Oils, J. Am. Oil Chem.Soc., vol. 83, no. 10, p.
Industrial Lubrication and Tribology, vol. 899-903.
54, no. 4, p. 165 - 170. [30] Adhvaryu, A., Erhan, S.Z., Liu, Z.S., Perez,
[28] Santos, J.C.O., Santos, I.M.G., Souza, A.G. J.M. (2000) Oxidation kinetic studies of
(2005) Effect of heating and cooling on oils derived from unmodified and
rheological parameters of edible vegetable genetically modified vegetables using
oils, J. of Food Engineering, vol. 67, p. pressurized differential scanning
401-405. calorimetry and nuclear magnetic resonance
[29] Fasina, O.O., Hallman, H., Craig-Schmidt, spectroscopy, Thermochimica Acta, , vol.
M., Clements, C. (2006) Predicting 364, p. 87-97.
temperature-dependence viscosity of

142 Kobasko, N. I. - Carvalho de Souza, E. - Canale, L. C. F. - Totten, G. E.

You might also like