Professional Documents
Culture Documents
Rainwater Tank Solutions
Rainwater Tank Solutions
Rainwater Tank Solutions
Taylex Tanks
Manufacturing Tanks Since 1969
Rainwater
Tank Solutions
Cool, clean water
in concrete or plastic
www.taylex.com.au
TAY L EX
Pre-Cast Concrete
Tanks
TM
Taylex Tanks
Rainwater Tanks
Wastewater & Rainwater Specialists Since 1969
1300 660 225 Australia Wide
www.taylex.com.au
Concrete Construction
Non Return
Valve
Maximum Water Level
Overflow
Tapered Taylex Tanks contain more concrete that most other brands
Wall and are therefore heavier and stronger.
5000 Litre
available on request.
* 2.5 Tonne Point Load Limit
2400mm Diameter
150mm Riser & Lid
150mm Tank Lid
Remember your tank needs to
Approximately 1000 gallons INLET 100mm OUTLET 100mm be able to withstand ground
movement and pressure as well
Installation
Above Ground as the weight of the water.
1900mm
1600mm
In Ground
hold
Underground Weight with Lid
A 22,000Lt Tank can !!
5 TONNES
22 Tonne of Water
nk!
+ the Weight of the Ta
Comes complete with Light Trafficable Lid and Riser
1L = approx 1kg.
* 2.52750mm
Tonne Point Load Limit
10000 Litre
Diameter
150mm Riser & Lid
150mm Tank Lid
INLET 100mm OUTLET 100mm Concrete won’t...
Approximately 2000 gallons
Burn, bend or buckle!
Installation
Above Ground
2390mm
2690mm
Tanks Tanks
15 Year
Warranty
On concrete vessels
150mm Riser & Lid
150mm Tank Lid
* 2 Tonne Point Load Limit
Optional Light Trafficable Lid and Riser
15000 Litre
3450mm Diameter
100mm
Non-Trafficable Lid
2000mm
Light Trafficable or Non-Trafficable Lid 10.2 TONNES
In Ground
Use multiple tanks where a high water Weight with Non-Trafficable Lid
table creates an installation problem Underground
9.1 TONNES
Only with Light Trafficable Lid
Ou r M o st Pop u la r
150mm Riser & Lid
150mm Tank Lid
3450mm Diameter
Underground Tank Non-Trafficable Lid
100mm
22000 Litre
Weight with Trafficable Lid
Approximately 5000 gallons 11.1 TONNES
Optional: Installation
2750mm
Light Trafficable or Non-Trafficable Lid Above Ground Weight with Non-Trafficable Lid
10 TONNES
Our most popular underground tank In Ground
Ideal for trickle feed and mains Underground
assisted household water storage Only with Light Trafficable Lid
Ou r M o st Pop u la r
3450mm Diameter
Non-Trafficable Lid
100mm
In Ground Tank
2000mm
Tanks
TM
Taylex Tanks
Poly Rainwater Tanks
Wastewater & Rainwater Specialists Since 1969
1300 660 225 Australia Wide
The Taylex Difference
www.taylex.com.au
Urban Range
Capacity Weight Diameter Overall Height Height to Inlet Height To Overflow
5000Lt
• Stronger than industry standards
• Full range of colours
• Easy Do It Yourself install
• Or call a plumber for install
• Delivered to your door
• Fitted with brass inlet/outlet
• Overflow and Strainer supplied ur
See o nge
• Plastic Ball Valve supplied l R a
Rura e for
Pag and
rs
Colou ation
Install s
Tip
10000Lt
PLEASE NOTE: Some products may not be available
in all areas. Please check with your consultant.
Tanks
TM
Taylex Tanks
Poly Rainwater Tanks
Taylex are an authorised distributor of Camel Tanks
Wastewater & Rainwater Specialists Since 1969
1300 660 225 Australia Wide
www.taylex.com.au Look at these Features
No centre pole - Extra thick base
Rural Camel Range Unique ribbed roof for extra strength
Food Grade Polyethylene - 25% Stronger
Roof mounted overflow for extra storage & mozzie gauze
420mm inlet gauze (confined space strainer available)
24000 Lt Standard Quality brass outlet fitting 25-50mm
Heavy Duty Stainless Steel Ball Valve 25-50mm
400mm Strainer and cover
Tank Flex Hose 25-50mm
Installation Tips
Weight
• Site needs to be level and on stable, compacted
500Kg ground that is capable of bearing the weight of your
new tank.
4000mm
Tank White 057 Off White 073 Birch Grey 838 Bush Grey 886 Merino Beige 918 Beige 916 Gull Grey 887 Armour Grey 890 Smooth Cream 947 Wheat 930 Beach 948 Pale Terracotta 406 Tuscan Red 574
Heritage Red 45 Clay Brown 413 Spinning Gum 285 Mist Green 206 Rivergum 234 Dark Green 2081 Bronze Olive 210 Torres Blue 387 Storm Blue 3014 Bluestone 3012 Mountain Blue 392 Slate Grey89 Black 70,718
PLEASE NOTE: All colours are as close as modern printing processes allow
Taylex Tanks
How to Save Money
Tanks
Pumps & Accessories Taylex has a large range of pumps, mains water
controllers, water switches, trickle feed setups
and quality fittings.
The finishing touches Only name brands are used including, Davey,
Onga and DAB.
TAY L EX
Warranties TM
Tanks Warranty
The future is safe
Manufacturing Tanks Since 1969
Every Taylex Tank is covered by a full
manufacturer’s warranty.
10 Year Warranty on Urban Plastic Tanks
Taylex Tanks
Things You Should Know
Wastewater & Rainwater Specialists Since 1969 About Concrete
Concrete is the most used, man-made product in the world,
produced using naturally occuring sands and gravels with cement
Risers & Lids which, through a process called “hydration” solidifies to a rock
hard product that is perfect for the construction of water storage
All Trafficable lids are supplied with a 150mm concrete lid and tanks.
a 150mm tall manhole access point. Extra 150mm Risers are
available if a tank is to be buried more than 150mm deep (see
underground installation diagram to left). It is a construction strength product capable of withstanding fire,
heat, ground movement... and bullets! It is a natural insulator able
Cast Iron Manhole Covers to keep the stored water at a relatively constant, cool temperature
in a dark environment which controls any algae growth.
A steel lid or manhole cover (Gatic) is designed to be placed
above the tank riser in a concrete slab or driveway. Using this
product you can then have access to a tank placed under a
driveway, paving or concrete slab. Types of Installations: - Concrete Tanks
Manhole Access
Riser & Lid -
Preventing Tank Floatation Underground:
Tank Lid
Underground concrete or
cast iron
As tanks empty they may float if the groundwater level rises.
This installation allows a tank
Please make sure your tanks are filled with water to prevent Max 300mm
to be buried underground with
the tank from floating. Only after full installation is complete i.e
only an inspection hole visible
stormwater drains and overflows are connected properly to the
at ground level. It is only
tank, should the tank be allowed to empty.
suitable for tanks with
Light-Trafficable Lids (2 tonne
Concrete Anti-Floatation Collars point load limited - not trucks).
If your property has a high water table, it may be necessary to A maximum overburden (soil)
install multiples of shorter tanks so that your tank can be of 300mm is safe for this tank
installed on top of the watertable and not in it. If a tank needs to installation. If you require to
be placed in a high water table area we may need to install a build or place a driveway over
concrete collar that sits at the base of the tank to prevent these tanks, please make sure
Heavy Duty Lids:
flotation. Your Taylex consultant will advise you if this is that your slab is engineered
necessary. and constructed to give extra In some cases we can
strength to assist your 2 tonne organise lids that may be
point load limit on the lid buried to a greater depth.
Engineered Light Trafficable Lids (please enquire regarding
design. You will require a cast
iron Access Cover for this type costs for engineer designs).
* Nominated Point Load Limits on of installation.
Light Trafficable Lids is the
In Ground
MAXIMUM Weight Permitted In-ground:
on these tanks Including Soil. This installation allows a tank
(For safety reasons, weight in excess of the engineer’s to be placed in the ground with
specifications should not be allowed on these lids) approximately 300mm –
500mm or more of the top of
Installation of 2 part tanks (31500Lt) the tank above the ground
In-ground installations are best for these tanks. Soil levels level. It is suitable for tanks with
should be the same on all sides of the tanks to prevent leaking a Light-Trafficable Lid or a
or movement of the tank. Also where possible, the middle join more cost effective Non-
should be placed underground. Trafficable Lid.
Above Ground
Best Practice Installation Original Above-ground:
Ground
for 2 Piece Tanks Level This installation allows a tank
New to be placed on a min 100mm
Ground boxed or sunken pad of
Level
5-7mm gravel . It is suitable for
tanks with both Non-Trafficable
and Light-Trafficable lids.
Ensure that ground water and
overflow pipes cannot wash
away the Base and ground
area around tank.
Wa t
s te w en R ainw s
Tanks ater Treat m ater Tan k
Darwin
Cairns
Townsville
Bowen
Mackay
Rockhampton
Biloela
Roma Bundaberg
Nanango
Hervey Bay
Toowoomba
Sunshine Coast
Laidley
Gold Coast
Warwick
Tweed Heads
Tamworth
Ballina
Coffs Harbour
Orange Port Macquarrie
Mildura
Canberra Port Stevens
Perth Deniliquin MacMasters Beach
Kyabram Sydney
Albury
Shepparton Mossy Point
Adelaide Bendigo Seymour Bega
cl e
www.taylex.com.au © Copyright Taylex Industries Pty Ltd 2010 - Issued February 2010