Professional Documents
Culture Documents
Folleto EVAC 3 Ascensores
Folleto EVAC 3 Ascensores
EVAC 3
Evacuation units for elevators
EVAC 3
Ev a c u a t i o n u n i t s f o r elevators
Functional description
The EVAC 3 evacuation unit monitors the power supply of the
ZETADYN 3 frequency inverter. With the drop out of one or
more phases the ZETADYN 3 will be disconnected from the
mains power supply. At the same time, the elevator control is
informed about the mains failure. The battery supply voltage
is switched in, time delayed.
General features
C an be used for both synchronous and induction motors
C an be used for ZETADYN 3 frequency inverters
11 A to 74 A
C ontrol cabinet installation (EVAC 3B) or wall installation
(EVAC 3C)
6 0 min availability (with limited number of trips)
I ntegrated mains power supply monitoring
I ntegrated charger for controlled charging of lead-acid
rechargeable batteries
O peration and configuration by the ZETAPAD operating
panel
M onitoring of the battery temperature
P erformance test by digital input
2 www.ziehl-abegg.com
EVAC 3B
The solution for control cabinet installation
Individual features
LED display for operation / malfunction
4 x relay outputs
2 x digital inputs (24 VDC)
Battery voltage 96 VDC ... 216 VDC
www.ziehl-abegg.com 3
EVAC 3C
Th e c o m p a c t s o l u t i o n
Individual features
L ED display for operation / malfunction
4 x relay outputs
4 x digital inputs (24 VDC)
B attery voltage 96 VDC ... 216 VDC
E xternal main switch; that enables installation in the ele-
vator shaft
P refabricated cables for quick installation
I ntegrated power contactors for switching from
normal to battery operation
I ntegrated inverter 230 VAC / 500 W for supplying:
Elevator control
Cabin light
Door drive
Motor brake
S D card slot for data backup
4 www.ziehl-abegg.com
EVAC 3
Te c h n i c a l D a t a
Weight [kg] 2 30 46 74
Dimensions
EVAC 3C EVAC 3B
www.ziehl-abegg.com 5
EVAC 3
Sy s t e m c o m p o n e n t s
Battery set
Both evacuation units require a battery set for the power sup-
ply of the frequency inverter and additional components.
Type designation EVAC BATT 032-120-24 EVAC BATT 050-120-24 EVAC BATT 074-120-24
Dimensions WxHxD [mm] 1180 x 194 x 130 1180 x 194 x 130 1180 x 194 x 130
Weight [kg] 2 x 50 2 x 50 2 x 50
Type designation EVAC BATT 032-180-7.2 EVAC BATT 032-180-24 EVAC BATT 050-180-24 EVAC BATT 074-180-24
Nominal voltage [VDC] 180 (84 + 96) 180 (3 x 60) 180 (3 x 60) 180 (3 x 60)
Dimensions WxHxD [mm] 908 x 167 x 116 1180 x 194 x 130 1180 x 194 x 130 1180 x 194 x 130
Weight [kg] 24 + 26 3 x 50 3 x 50 3 x 50
6 www.ziehl-abegg.com