11 Overall Utility Plan

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

HMAC

OVERALL ANAQUA SPRINGS


PL PL
LEGEND

RANCH BOUNDARY
50'
UNIT BOUNDARY
14.5' 21' PAVING 14.5' 600
EXISTING 5' CONTOUR
EXISTING 4' 10.5' 10.5' 18" 4'
18" EXISTING 1' CONTOUR 599
GROUND
3:1 MAX 1/4":1' MIN SCALE: 1"=50'
1":1' MAX 1/4":1' MIN PUBLIC UTILITY EASEMENT P.U.E.
2%
1":1' MAX W
3:1 MA PROPOSED WATER LINE 0 25' 50' 75' 100'
X

W W W
PROPOSED DUAL WATER SERVICE
SUBGRADE 2.0'
PROPOSED SINGLE WATER SERVICE
CRUSHED LIMESTONE BASE
CRUSHED LIMESTONE BASE PROPOSED WATER LINE 1410 PROPOSED FIRE HYDRANT

EXISTING WATER LINE Wx


TYPICAL STREET SECTION
(VARIABLE WIDTH) EXISTING FIRE HYDRANT
N.T.S.

NOTES:

1.129 AC 1. SEWAGE FACILITIES SHALL BE PROVIDED BY AN ON-SITE SEWAGE FACILITY


LOT 12 CONSTRUCTED ON EACH LOT BY THE OWNER THEREOF DESIGNED BY A
JAMES M MIDDLETON REVISIONS:
REGISTERED SANITARIAN OR A REGISTERED ENGINEER AND APPROVED UNDER
CB 4671A LOT 41 BLOCK 2
THE RULES OF BEXAR COUNTY AND TCEQ.
1400 VOL. 11362 PG. 793
B.C.O.P.R.
1.207 AC SEWER SERVICE PROVIDED BY: INDIVIDUAL OSSF SYSTEMS
0.208 AC
LOT 10 WATER SERVICE PROVIDED BY: SAN ANTONIO WATER SYSTEMS - CCN # 10640
LOT11

ND ARY 2. ELECTRIC SERVICE STUBS TO BE CHARGED TO THE ANNUAL ORDER FOR


ELECTRIC SERVICES (0210587 9020).
BOU
TY
PER
PRO

FUTURE ROW 2" BLOWOFF ASSEMBLY (PERM)


BLOCK 2 12" X 2" THR DI. ECCENTRIC REDUCER, M.J. (PERM)
SEE SAWS STD, DWG DD-844-02 30'
LIMITS OF
CONSTRUCTION
50'
PINSON INTERESTS LTD LLP 1.004 AC PROPOSED STUB OUT

13
VOL. 9639 PG. 138 LOT 9 FOR FUTURE EXPANSION SAWS JOB

90
B.C.O.P.R. LOT 998 NUMBER: 04-1301

55 LF OF 12" WATER MAIN

1400
W LOT 2 ANAQUA SPRINGS RANCH UNIT 2
1.001 AC W Wx
BLOCK 1 PLAT # 040466
VOL. 9643 PG. 2349
Wx

LOT 8 W
B.C.R.P.R.
W

4* CONNECT TO
0 4*
143
0 141 W EXISTING STUBOUT 10' ELEC, GAS, TELE, C.A. TV,
WATER, INGRESS/EAGRESS
238 LF OF 12" WATER MAIN

43*
EASEMENT (VOL. 9583, PG. 169)
43* EXISTING
43* FIRE HYDRANT
10' ELEC., GAS, TELE, 1~ 12" 1/32 BEND
T)
W
CA. TV., WATER AND EE
E STR .)
INGRESS/EGRESS T
IVA O.W
W
94 LF OF 12" WATER MAIN
EASEMENT W (PR (50' R.
W

4* PROPOSED DRAIN "A"


4*
S W 170 LF OF 12" WATER MAIN 1 ~ 12" X 12" TEE, M.J. FRANKY L HAMILTON
1.188 AC G
RIN 2 ~ 12" GATE VALVE, M.J. W/BOX
W
CB 4671A BLOCK 7 LOT 16
LOT 7 S P VOL. 16232 PG. 643
T 1~ 12" 1/32 BEND
W CA W
2.120 AC B.C.O.P.R.
LOT 1
1~12"X6" ANCHOR TEE, M.J.
1~6" X 1/4 BEND, M.J.
1~6" GATE VALVE, M.J.
1~6" VALVE BOX,COMPLETE
* 1~STD. FIRE HYDRANT VARIABLE WIDTH
1~12"X6" ANCHOR TEE, M.J. 18* 18 167 LF OF 12" WATER MAIN
1~6" D.I. PIPE, CUT AS REQUIRED DRAINAGE EASEMENT
1~6" X 1/4 BEND, M.J. EXISTING TREE TO REMAIN SEE
SEE SAWS STD. DWG DD-834-01
1410 1380
W

1~6" GATE VALVE, M.J. TREE PROTECTION DETAILS

ANAQUA SPRINGS RANCH UNIT 7


1~6" VALVE BOX,COMPLETE 1~ 12" 1/8 BEND
1~STD. FIRE HYDRANT
W VARIABLE WIDTH
1~6" D.I. PIPE, CUT AS REQUIRED 1.219 AC DRAINAGE EASEMENT
2.226 AC SEE SAWS STD. DWG DD-834-01 79LF OF 12" WATER MAIN LOT 2
LOT 6

OVERALL UTILITY PLAN


1.344 AC

BEXAR COUNTY, TEXAS


LOT 3

1400
1.473 AC
0
LOT 4 137

FOR
0.181 AC Y
LOT 5 VARIABLE WIDTH UN DAR
DRAINAGE EASEMENT 1360 UN IT BO
VARIABLE WIDTH
DRAINAGE EASEMENT (VOL. 9583, PG. 169)
1380

VARIABLE WIDTH
DRAINAGE EASEMENT

PATRICIA WALLACE
138 CB 4672 P-1K
0 ABS 156

0
138
OVER ANCH BOU

PATRICIA WALLACE 70
R

13
ALL A

CB 4672 P-1K
1390 ABS 156
NAQU DARY
N
A SPR

CU101
INGS

JOB NO. SCHOOL


DESIGNED BY: XV
DRAWN BY: XV
G:\21 - Anaqua Springs Unit 7\C\13 OVERALL UTILITY PLAN.dwg CHECKED BY: AA
Date: Apr 24, 2017, 7:27pm User ID: xvasquez SHEET # 11 OF 13

You might also like