DATA DAN PENGAMATAN AWAL

Q (inc) D (inc) L HL Q(GPH)


60 1.375
1 34 0.75
26 0.25
60 5.375
5 0.75 34 2.75 300
26 1
60 11.75
0.5 34 6.125
26 5.5
60 0.875
1 34 0.625
26 0.5
60 2.5
2.265 0.75 34 1.625 220
26 1.25
60 9.125
0.5 34 5.25
26 4.25
60 0.625
1 34 0.5
26 0.125
60 3
1.125 0.75 34 1.5 160
26 0.875
60 7
0.5 34 4.25
26 3
TABULASI HEAD LOSS TERHADAP DEBIT TIAP PANJANG PIPA
hL (in)
Q (GPH)
D1 = 1 in D2 = 0,75 in D3 = 0,5 in
1.375 5.375 11.75 300 L=60 in
0.875 2.5 9.125 220
0.625 3 7 160

head loss terhadap debit pada L=60 inch


14
12
10
diameter 1 inch
8
diameter 0,75 inch
head loss6(inch)
diameter 0,5 inch
4
2
0
140 160 180 200 220 240 260 280 300 320

debit (GPH)

hL (in)
Q (GPH)
D1 = 1 in D2 = 0,75 in D3 = 0,5 in
0.75 2.75 6.125 300 L=34 in
0.625 1.625 5.25 220
0.5 1.5 4.25 160

head loss terhadap debit pada L=34 inch


7
6
5
diameter 1 inch
4
diameter 0,75 inch
head loss3(inch)
diameter 0,5 inch
2
1
0
140 160 180 200 220 240 260 280 300 320

debit (GPH)

hL (in)
Q (GPH)
D1 = 1 in D2 = 0,75 in D3 = 0,5 in
0.25 1 5.5 300 L=26 in
0.5 1.25 4.25 220
0.125 0.875 3 160

head loss terhadap debit pada L=26 inch


6

5
head loss terhadap debit pada L=26 inch
6

4 diameter 1 inch

head loss3(inch) diameter 0,75 inch


diameter 0,5 inch
2

0
140 160 180 200 220 240 260 280 300 320

debit (GPH)
TABULASI FAKTOR GESEK TERHADAP PANJANG PIPA TIAP DEBIT
Q1=300 GPH
Q1=0.01114005 ft3/s
Diameter (in) L (in) h L (in) V (ft/s) f favg
60 1.375 8.170 0.0009213
1 34 0.75 8.170 0.0008868 0.0007315
26 0.25 8.170 0.0003865
60 5.375 8.170 0.0054020
0.75 34 2.75 8.170 0.0048773 0.0041995
26 1 8.170 0.0023193
60 11.75 8.170 0.0157453
0.5 34 6.125 8.170 0.0144841 0.0157458
26 5.5 8.170 0.0170080

Faktor Gesekan Pipa terhadap Panjang Pipa pada Debit Q = 300 GPH
0.0180000
0.0160000
0.0140000
0.0120000
0.0100000 diameter 1 inch
f 0.0080000 diameter 0,75 inch
diameter 0,5 inch
0.0060000
0.0040000
0.0020000
0.0000000
20 25 30 35 40 45 50 55 60 65

L (in)

Q1=220 GPH
Q1=0.0081693524 ft3/s
Diameter (in) L (in) h L (in) V (ft/s) f favg
60 0.875 5.991 0.0010902
1 34 0.625 5.991 0.0013742 0.0013006
26 0.5 5.991 0.0014376
60 2.5 5.991 0.0046721
0.75 34 1.625 5.991 0.0053592 0.0051407
26 1.25 5.991 0.0053909
60 9.125 5.991 0.0227377
0.5 34 5.25 5.991 0.0230858 0.0234207
26 4.25 5.991 0.0244388

Faktor Gesekan Pipa terhadap Panjang Pipa pada Debit Q = 220 GPH
0.0300000

0.0250000

0.0200000
diameter 1 inch
f 0.0150000 diameter 0,75 inch
Faktor Gesekan Pipa terhadap Panjang Pipa pada Debit Q = 220 GPH
0.0300000

0.0250000

0.0200000
diameter 1 inch
f 0.0150000 diameter 0,75 inch
diameter 0,5 inch
0.0100000

0.0050000

0.0000000
20 25 30 35 40 45 50 55 60 65

L (in)

Q1=160 GPH
Q1=0.0059412095ft3/s
Diameter (in) L (in) h L (in) V (ft/s) f favg
60 0.625 4.357 0.0014723
1 34 0.5 4.357 0.0020785 0.0014101
26 0.125 4.357 0.0006795
60 3 4.357 0.0106004
0.75 34 1.5 4.357 0.0093533 0.0090295
26 0.875 4.357 0.0071349
60 7 4.357 0.0329789
0.5 34 4.25 4.357 0.0353346 0.0336433
26 3 4.357 0.0326165

Faktor Gesekan Pipa terhadap Panjang Pipa pada Debit Q =160GPH


0.0400000
0.0350000
0.0300000
0.0250000
diameter 1 inch
f 0.0200000 diameter 0,75 inch
0.0150000 diameter 0,5 inch
0.0100000
0.0050000
0.0000000
20 25 30 35 40 45 50 55 60 65

L (in)
Q (inc) D (inc) L HL Q(GPH)
60 1.375
1 34 0.75
26 0.25
60 5.375
5 0.75 34 2.75 300
26 1
60 11.75
0.5 34 6.125
26 5.5
60 0.875
1 34 0.625
26 0.5
60 2.5
2.265 0.75 34 1.625 220
26 1.25
60 9.125
0.5 34 5.25
26 4.25
60 0.625
1 34 0.5
26 0.125
60 3
1.125 0.75 34 1.5 160
26 0.875
60 7
0.5 34 4.25
26 3

You might also like