RADOJLE RADETI
PREKIDAKA
NAPAJANJA
BOR, 2006
PREKIDAKA NAPAJANJA
Mr Radojle Radeti, dipl. in.
Recenzent: Dr arko Janda, Institut Nikola Tesla, Beograd
Izdava: IP Nauka Beograd
Za izdavaa: Nikola Donev, direktor i glavni odgovorni urednik
Kompjuterska obrada teksta: Milo i arko Radeti
Tira, 300 primeraka
tampa: Grafomed, Bor
CIP - Katalogizacija u publikaciji
Narodna biblioteka Srbije, Beograd
621.314.5:621.382.3
RADETI], Radojle
Prekidaka napajanja / Radojle Radeti. - Beograd : Nauka,
2005 (Bor : Grafomed). 157 str. : graf. prikazi ; 24 cm
Tira 300. - Na kor. autorova slika i beleka o njemu. -
Bibliografija: str. 155 -157.
ISBN 86-7621-137-X
a) Tranzistorski pretvarai
COBISS.SR-ID 127889420
Vane napomene
0. Autor se trudio da sva materija u ovoj knjizi bude izloena na taan i jasan
nain. Meutim zbog moguih greaka, autor ne snosi nikakvu odgovornost u
sluaju eventualnih teta nasalih zbog toga.
1. Praktian rad sa pretvaraima, koji su predmet razmatranja ove knjige, moe biti
opasan po ivot. Zato je neophodno pri radu, pridravati se odgovarajuih mera
zatite propisanih za rad sa elektrinim ureajima.
2. Autor zadrava sva prava eventualnih izmena, bez obaveze prethodnog
obavetenja.
3. Bilo kakvo umnoavanje, pretampavanje i kopiranje celine ili pojedinih delova
ove knjige, nije dozvoljeno bez prethodne dozvole autora.
PREDGOVOR
Energetska elektronika i njena oblast energetski pretvarai veoma se intenzivno
razvijaju. Taj razvoj ide u vie pravaca kao to su: pronalaenje i usavravanje ve
postojeih komponenata (kako energetskih tako i upravljakih), novih topologija
pretvaraa, poveanje snage postojeih vrsta pretvaraa, proirenje oblasti njihove
primene itd.
Jedno posebno interesantno podruje su ureaji snaga od nekoliko desetina, do
nekoliko stotina wati (pa i do par kilovata). To su napajanja koja se prikljuiju na
jednu fazu napojne mree a na izlazu daju odgovarajui jednosmerni napon (jedan ili
vie). Ovakve napojne jedinice imaju iroku primenu kod TV aparata, personalnih
raunara, raznih audio i video ureaja, osvetljenja itd. Meutim sve je ea njihova
primena u industijskim pogonima i radionicama gde slue za punjenje stacionarnih
akumulatorskih baterija, elektoluno zavarivanje, regulaciju brzine DC motora
manjih snaga, kao rezervna napajanja itd.
Ova knjiga ima za cilj da itaocima prikae najinteresantnija pitanja i neka
savremena reenja iz ove oblasti, kao i da ukae na mogue trendove razvoja. Ova
materija je delimino obraena i u knjizi Tranzistorski pretvarai snage, meutim
zbog interesantnosti i aktuelnosti materije, autor je smatrao da ima smisla da se ona
jo detalnije obradi i da izae u obliku posebne knjige.
Knjige sa ovom temom na naem jeziku nema, i ovom autoru je zapala i ta
nezahvalna uloga da od poetka definie njenu koncepciju, sadraj i obim. Ponekad je
najvei problem autora da odredi pravu meru do koje dubine ui u neku materiju.
Postoji obilje pratee tehnike literature proizvoaa ovih ureaja i komponenata,
strunih i naunih radova i slino, veoma lako dostupne zahvaljujui internetu.
Veoma je teko ovu materiju lepo sistematizovati, sloiti i na pristupaan nain je
izloiti itaocu. Ovo je jedan pokuaj, i lino sagledavanje problema. Neka ono bude
ohrabrenje i podsticaj i drugim autorima da uine slino.
Ovako koncipirana knjiga namenjena je svima koji se bave tom vrstom napojnih
ureaja. Mogu je koristiti tehniari, inenjeri elektro struke ali i svi drugi koji se bave
pretvaraima. Za razumevanje izloene materije neophodno je osnovno poznavanje
elektronike, karakteristika tranzistora snage, MOSFETova, IGBT, ali i nekih oblasti
energetike. Nadam se da e ova knjiga posebno biti korisna onima koji se i praktino
bave napojnim ureajima (konstruktori, proizvoai, serviseri itd.) ali i onima koji to
rade iz hobija, studentima i mnogim drugima.
Na kraju elim da se zahvalim svim svojim kolegama koji su mi tokom pisanja
pomogli svojim savetima i sugestijama, kao i svima ostalima koji su na bilo koji
nain doprineli da ova knjiga bude izdata. U tom smislu, posebnu zahvalnost
dugujem svojoj firmi JP EMS.
UVOD ........................................................................................................................... 9
1. JEDNOIMPULSNI DIREKTNI PRETVARAI .......................................... 13
1.1. PRETVARA TIPA BUCK (SPUTA NAPONA) ................................ 13
1.1.1. Princip rada.......................................................................................... 13
1.1.2. Prednosti i mane buck pretvaraa ....................................................... 15
1.1.3. Primeri buck pretvaraa ...................................................................... 16
1.2. PRETVARA TIPA BOOST (PODIZA NAPONA) .............................. 20
1.2.1. Princip rada.......................................................................................... 20
1.2.2. Prednosti i mane boost pretvaraa....................................................... 21
1.2.3. Primeri boost pretvaraa...................................................................... 22
1.3. PRETVARA TIPA BUCK-BOOST......................................................... 23
1.3.1. Princip rada.......................................................................................... 23
1.3.2. Prednosti i mane buck-boost pretvaraa ............................................. 25
1.3.3. Primer buck-boost pretvaraa ............................................................. 25
1.4. PRETVARA TIPA UK.......................................................................... 26
1.4.1. Prednosti i mane ovog pretvaraa ....................................................... 27
1.5. PRETVARA TIPA SEPIC ....................................................................... 28
1.6. REVERZNI JEDNOIMPULSNI DIREKTNI PRETVARAI .................. 29
1.7. REGULACIJA BRZINE ELEKTROMOTORA ........................................ 31
1.7.1. Regulacija brzine DC motora - operi................................................ 32
1.7.1.1. operi klase A ................................................................................. 35
1.7.1.2. operi klase B ................................................................................. 38
1.7.1.3. operi klase C ................................................................................. 41
1.7.1.4. operi klase D................................................................................. 43
1.7.1.5. operi klase E ................................................................................. 46
2. JEDNOIMPULSNI INDIREKTNI PRETVARAI...................................... 49
2.1. PRETVARA TIPA FORWARD .............................................................. 50
2.1.1. Princip rada.......................................................................................... 51
2.1.2. Izbor transformatora............................................................................ 54
2.1.3. Primeri forward pretvaraa.................................................................. 56
2.1.4. Prednosti i mane forward pretvaraa................................................... 58
2.1.5. Neke tehnike koje se danas koriste kod pretvaraa............................. 58
2.2. PRETVARA TIPA FLYBACK ............................................................... 63
2.2.1. Osnovna konfiguracija ........................................................................ 64
2.2.2. Flyback pretvarai bez vraanja energije............................................ 67
2.2.2.1. Rad pretvaraa sa kontinualnom strujom....................................... 70
2.2.2.2. Rad pretvaraa sa diskontinualnom strujom .................................. 74
2.2.2.3. Uporeenje snaga ........................................................................... 77
5
2.2.3. Prednosti i mane forward pretvaraa................................................... 77
2.2.4. Primeri pretvaraa ............................................................................... 78
2.3. PRETVARA TIPA UK SA TRANSFORMATOROM......................... 81
2.3.1. Princip rada.......................................................................................... 81
2.3.2. Prednosti i mane .................................................................................. 82
3. DVOIMPULSNI PRETVARAI .................................................................... 83
3.1. PU-PUL (PUSH-PULL) PRETVARA................................................... 83
3.1.1. Princip rada.......................................................................................... 83
3.1.2. Elementi prorauna transformatora..................................................... 86
3.1.3. Prednosti i mane push-pull pretvaraa ................................................ 89
3.1.4. Primer pretvaraa ................................................................................ 89
3.2. POLUMOSTNI PRETVARA .................................................................. 90
3.2.1. Princip rada.......................................................................................... 90
3.2.2. Transformator sa predmagneenjem (neizbalansiran) ........................ 92
3.2.3. Elementi prorauna transformatora..................................................... 92
3.2.4. Prednosti i mane polumostnih pretvaraa ........................................... 93
3.3. MOSTNI PRETVARA............................................................................. 94
3.3.1. Princip rada.......................................................................................... 94
3.3.2. Elementi prorauna transformatora..................................................... 97
3.3.3. Prednosti i mane mostnih pretvaraa .................................................. 98
3.3.4. Sinhrono ispravljanje Kod dvoimpulsnih pretvaraa.......................... 99
3.3.5. ZVT tehnika kod dvoimpulsnih pretvaraa ...................................... 100
3.3.6. Rezonantni rad pretvaraa................................................................. 101
3.3.7. Udvostruiva struje.......................................................................... 102
3.3.8. Primer mostnog pretvaraa................................................................ 103
4. UPRAVLJANJE PRETVARAIMA ........................................................... 105
4.1. UPRAVLJANJE BIPOLARNIM TRANZISTORIMA............................ 105
4.2. UPRAVLJANJE TRANZISTORIMA TIPA MOSFET ........................... 105
4.3. DRAJVERSKA KOLA............................................................................. 106
4.3.1. Opti principi..................................................................................... 106
4.3.2. Drajverska kola serije IR 21xx.......................................................... 108
4.4. NAINI UPRAVLJANJA PRETVARAIMA ....................................... 113
4.4.1. Regulacija po naponu ........................................................................ 113
4.4.2. Regulacija po struji............................................................................ 114
4.4.3. Histerezisna regulacija ...................................................................... 114
4.4.4. Integrisana kola za upravljanje pretvaraima.................................... 115
4.4.4.1. Kolo CD4047................................................................................. 115
4.4.4.2. Kolo TL494.................................................................................... 117
4.4.4.3. Kolo MC3420 ................................................................................ 119
4.4.4.4. Kola familije SG1525 .................................................................... 119
4.4.4.5. Kola familije UC1875 ................................................................... 119
6
5. DODATAK....................................................................................................... 123
5.1. PRORAUN FERITNIH TRANSFORMATORA .................................. 123
5.2. PRIGUNICE ........................................................................................... 131
5.3. REZONANTNI RAD PRETVARAA.................................................... 134
5.3.1. Rezonantni rad kod jednoimpulsnih pretvaraa................................ 134
5.3.2. Rezonantni rad kod invertora ............................................................ 136
5.4. DUALIZAM ELEKTRINIH KOLA...................................................... 139
5.5. KARAKTERISTIKE NEKIH TRANZISTORA ...................................... 140
5.6. PRIMERI NAPOJNIH JEDINICA ........................................................... 142
5.7. SVETSKI AUTORITETI ENERGETSKE ELEKTRONIKE POREKLOM
IZ SRBIJE ............................................................................................................. 153
LITERATURA ........................................................................................................ 157
7
Radojle Radeti, Prekidaka napajanja, Uvod
UVOD
I pored uobiajenog napajanja iz naizmenine napojne mree, za rad velikog broja
ureaja potreban je jednosmerni napon. Takvi su na primer: razni elektronski ureaji,
akumulatorske baterije, DC motori, itd. Visine ovih napona kreu se u opsegu od oko
3 do 300 V. Standardno napajanje domainstava, zanatskih radionica pa i industrije je
gradska mrea (220 Vac). Pored ovoga ponekad je na raspolaganju i baterijski napon.
Baterijsko napajanje se obino koristi kod prenosnih ureaja ili kao sigurnosno
napajanje stacionarnog tipa za ureaje koji zahtevaju veliku pouzdanost napajanja.
Ali opet i za punjenje i dopunjavanje ovih baterija potrebne su odgovarajue napojne
jedinice. Zato e pod napojnim jedinicama biti podrazumevani ureaji (pretvarai)
tipa AC/DC i DC/DC direktnog ili indirektnog tipa. U irem smislu to mogu biti i sve
druge vrste pretvaraa koji napajaju neki ureaj ili grupu ureaja (na primer invertori
islino).
U prvom sluaju (napajanje iz AC mree), dobijanje izlaznog jednosmernog
napona zahtevanih karakteristika je neto sloenije. Naravno u tom procesu dobijanja
DC napona potrebno je prethodno ispravljanje ovog napona i zatim njegova dalja
obrada. Stariji tipovi ureaja su ovde koristili mrene transformatore kojima je napon
prethodno sniavan na potrebnu vrednost, zatim ispravljan, filtriran i stabilisan.
Prve verzije ovih napajanja koristile su linearne stabilizatore. Zbog njihovog malog
stepena iskorienja, gubici su pretstavljali veliki deo ulazne snage tako da su
zahtevali velike hladnjake, to je same napojne jedinice ovog tipa inilo gabaritno
velikim, tekim i skupim.
U kasnijim reenjima veih snaga zadran je transformator a linerni stabilizator je
zamenjen prekidakim. Ovde je i dalje ostajao veliki i teak ulazni transformator,
veliki elektrolitni kondenzatori itd. Za ove primene razvijeno je vie vrsta pretvaraa
uglavnom jednoimpulsnih i direktnog tipa (buck, bost, itd). Ovi pretvarai nali su u
iroku primenu i kod ureaja sa baterijskim napajanjem (baterijski runi alati,
elektromobil itd.).
Danas se kod napojnih jedinica sniavanje visokog ulaznog napona vri sa
prekidakim pretvaraem sa visokom radnom frekvencijom, kod koga je glomazni
mreni transformator zamenjen feritnim, neuporedivo manjih dimenzija. Na ovaj
nain dobijeni su i napojni ureaji veoma malih gabarita.
9
Radojle Radeti, Prekidaka napajanja, Uvod
10
Radojle Radeti, Prekidaka napajanja, Uvod
11
Radojle Radeti, Prekidaka napajanja, Uvod
12
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
13
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
Kada se tranzistor iskljui (tOFF), struja prigunice se zatvara preko diode i deo
akumulisane energije se predaje optereenju. Struja se smanjuje. Kada se dostigne
stacionarno stanje, smanjenje struje u ovom intervalu jednako je poveanju u
prethodnom. U stacionarnom reimu proces se dalje ponavlja na isti nain, a struja
varira izmeu IMIN i IMAX.
Pri malom optereenju struja IMIN, moe da padne i na nulu, tako da struja postaje
diskontinualna.
Zanemarujui omsku otpornost prigunice i pad napona na diodi, srednja vrednost
inverznog napona na diodi jednaka je srednjoj vrednosti izlaznog napona.
Na sl.1-2 su prikazani karakteristini oblici
napona i struja, ovog pretvaraa. Napon na
prigunici prikazan je oseneno. Njegova
srednja vrednost jednaka je nuli, tako da ove
dve povrine moraju biti jednake. Za ovaj tip
pretvaraa, pri kontinualnoj struji, srednja
vrednost izlaznog napona je:
tON t
UO = U I = U I ON = U I a
tON + tOFF T
Koeficijent ispune je pozitivan i manji (ili
jednak) jedinici (a=0 ... 1), to znai da je i
izlazni napon pozitivan i uvek manji od ulaznog.
Tranzistor se bira prema maksimalnoj
vrednosti amplitude stuje i maksimalnom
naponu.
1
I C ,MAX > I O ,MAX + I L , U CE 0 > U I
2
Srednja vrednost struje prigunice jednaka je
izlaznoj:
sl. 1-2.
I L ,SR = I O
Pri malom optereenju struja postaje diskontinualna.
To se dogaa kada je srednja vrednost struje prigunice
manja od polovine porasta struje u intervalu vremena tON.
Granica diskontinualne struje je:
U O (1 a )
I O ,DISC =
2L f
Struja diode je:
tOFF
I D = IO = I O (1 a )
T
sl. 1-3.
14
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
15
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
16
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-6.
Dovoenjm pozitivnog potencijala na noicu 4, gornja granica se smanjuje. Unutar
kola se nalaze i dva pojaavaa greke koja se mogu upotrebiti za stabilizaciju,
podeavanje ili izlaznog napona ili struje pretvaraa. Referentni napon je na noici 5 i
iznosi 5 V.
Na izlazu kola se nalazi tranzistor sa odspojenim emiterom i kolektorom tako da se
po elji moe birati njegov spoj. Njegova maksimalna kolektorska struja je 200 mA.
Na sl. sl. 1-6, prikazan je pretvara tipa buck, sa mekim startom i regulacijom
napona i struje. Pretvara radi na sledei nain:
Neposredno po ukljuenju, noica 4 je spojena na referentni napon 5 V (noica 12)
preko kondenzatora 10 F koji se dalje puni preko otpora 390 poveavajui
granicu maksimalne ispune sa 1 % postepeno, do oko 80 %. Na taj nain obezbeen
je meki start pretvaraa.
Podeavanje napona vri se potenciometrom U, kojim se zadaje eljena vrednost
i ona komparira sa stvarnim naponom na izlazu razdelnika, a razlika pojaava
pojaavaem 1 (noice 1 i 2). Struja se zadaje potenciometrom I i komparira sa
stvarnom preko pada napona na entu 0,1 a signal greke pojaava pojaavaem 2
(noice 12 i 13). Vii od ova dva napona se pojavljuje na izlazu 3 za povratnu spregu
odravajui jednu od veliina (napon ili struju) na zadatoj vrednosti. Otpornik 47 K i
kondenzator 1 nF (noice 6 i 5) definiu frekvencu prekidanja, koja je ovde oko 25
kHz.
Na narednim sl. 1-7, prikazana je unutranja blok ema i izvedba ovog pretvaraa
sa integrisanim kolom MC34063. Po unutranjoj strukturi identina su i kola
MC33063 i MC35063, a razlika je samo u temperaturnom opsegu primenljivosti.
17
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-7.
Kolo se radi u plastinom i keramikom pakovanju kao osmopinsko. Najvanije
njegove karakteristike su:
- Ulazni napon je 2,5 do 40 V
- Strujni limit
- Maksimalna struja 1,5 A
- Podeavanje izlaznog napona od 1,25 do 40 V
- Radna frekvenca 100 Hz do 100 kHz.
- Mala sopstvena potronja struje
Poveanje izlazne struje moe se postii dodatnim spoljnim tranzistorima.
Sledei primer je kolo A78S40. Njegova blok ema i primena prikazana je na sl.
1-8. Pretvara je tipa buck. Najvanije njegove karakteristike su:
- Ulazni napon je 2,5 do 40 V
- Strujni limit
- Maksimalna struja 1,5 A
- Podeavanje izlaznog napona od 1,3 do 40 V
- Mala sopstvena potronja struje
18
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-8.
19
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
20
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
21
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-11.
sl. 1-12.
22
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
23
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
24
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-17.
25
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
26
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
27
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
Nedostatci:
- Velika kolektorska struja kod velikih odnosa izlaznog i ulaznog napona
- Dioda i kondenzator su izloeni jakim strujnim impulsima pri malim a
- Zahteva se tranzistor visoke naponske i strujne klase
- Ograniena izlazna snaga i td.
0.5. PRETVARA TIPA SEPIC
Zamenom mesta prigunice (L2) i diode (D) u ukovom pretvarau, dobija se
pretvara pod nazivom SEPIC (Single Ended Primary Inductance Converter). Njegov
izlazni napon moe biti manji, jednak ili vei od ulaznog. Dobijeni napon je istog
polariteta kao ulazni. Osnovna ema ovog pretvaraa prikazana je na sl.1-20 a
karakteristini talasni oblici napona i struja na sl. 1-21.
Pretvara radi na sledei nain. U toku prelaznog procesa kondenzatori C i CO se
pune do svojih stacionarnih napona. U
stacionarnom stanju napon na sprenom
kondenzatoru C jednak je ulaznom, a na CO
izlaznom. Kada je tranzistor ukljuen, obe
prigunice se nalaze pod ulaznim naponom.
Kroz tranzistor se zatvara njihova zbirna
struja. Struje prigunica rastu i u njima se
sl. 1-20. poveava akumulisana energija.
Kad se tranzistor iskljui struje obe
prigunice se zatvaraju kroz diodu i predaju
kondenzatoru. Srednja struja diode jednaka je
struji optereenja.
Za referentne smerove prema sl. 1-20, u
kontinualnom reimu, odnos napona i struja je:
U O I L1 I L1 tON a
= = = =
U I I L 2 I O tOFF 1 a
Tranzistor se bira prema maksimalnim
vrednostima napona i struje:
T U
U CE 0 > U I + U O = UI = I
T tON 1 a
IO 1
I T ,MAX > I L1,MAX + I L 2,MAX = + I L
1 a 2
Valovitost struje je:
L1 + L2
I L = I L1 + I L 2 = U I tON
L1 L2
sl. 1-21.
Maksilalni inverzni napon diode je:
28
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
UI
U DRM = U CE 0 > U I + U O =
1 a
Srednja vrednost struje diode jednaka je struji optereenja.
I D = IO
Pri malom optereenju na izlazu, struja diode postaje diskontinualna i ta granica je
pri izlaznoj struji:
I L 2 U I tON U a
I O ,DISC = = = I
2 2 L2 2 L2 f
Pogodno je pri izradi uzeti da prigunice budu jednake.
Kao i kod ukovog pretvaraa, postoje varjante i ovog pretvaraa sa spregnutim
induktivnostima L1 i L2.
Velika slinost ovog pretvaraa sa ukovim pretvaraem podrazumeva i sline
njegove dobre i loe osobine.
0.0. REVERZNI JEDNOIMPULSNI DIREKTNI PRETVARAI
Dosadanji pretvarai su mogli da prenose energiju samo u jednom smeru, od
izvora prema optereenju. Moe se pokazati da oni pretstavljaju samo deo sloenijih
dvosmernih (reverznih) pretvaraa. Bez ulaenje u detaljnu analizu, dalje e samo biti
prikazane topologije ovih pretvaraa. Prenoenje energije kod ovih pretvaraa vezano
je za tano odreeni nain upravljanja i naznaene smerove napona na obe strane. S
obzirom da samo struja moe da menja smer a polariteti napona ostaju nepromenjeni,
radi se o dvokvadrantnim pretvaraima (I i IV kvadrant). Na sl. 1-22, prikazani su
parovi ovih pretvaraa.
Vidi se da pretvarai tipa buck i boost pretstavljaju samo dve polovine jednog istog
pretvaraa (polumost). Pri tome napon sa strane prigunice mora biti manji od napona
sa strane prekidaa. Sa dva ovakva prekidaa u opoziciji (mostna veza), iz ulaznog
napona pozitivnog polariteta moe se dobiti na izlazu napon sa oba polariteta i
veliine manje od ulaznog. Takav pretvara je u stanju da prenosi energiju u oba
smera (etvorokvadrantni). Ovakve topologije koriste se kod invertora.
Kod ostalih dvosmernih pretvaraa ne postoji ogranienje u pogledu veliine dva
napona ve samo u njihovom polaritetu.
Daljnje uoptenje pretvaraa vodi ka etvorokvadrantnim pretvaraima.
Jednostavnija varjanta odnosi se na pretvarae sa transformacijom tipa DC/AC. Tako
se dobija mostni pretvara, koji se ee koristi kod invertora.
Sledei korak je potpuno uoptenje pretvaraa i transformacija AC/AC.
O nekim od ovih pretvaraa bie vie govora u narednim poglavljima.
29
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
sl. 1-22.
30
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
31
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
32
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
U a = E + Ra I a + U
Kada se motor optereti i pogon doe u stacionarno stanje, mehaniki moment je
izjednaen sa momentom koji se razvija u maini, i iznosi:
M e = c Ia
Oblik mehanike karakteristike je sada:
U a Ra I a U U a U Ra
n= = M e = n0 n
k k k c
U ovim izrazima su:
- Ra Otpor rotorskog kola
- U Pad napona na etkicama (oko 1V)
- k, c Konstante maine
- n Brzina obrtanja (obrtaja/min)
- n0 Brzina idealnog praznog hoda (obrtaja/min)
- Brzina obrtanja (rad/sec)
- p Broj pari polova
- Na Broj provodnika u ljebovima rotora
- a Broj paralelnih grana
Kao to se vidi, mehanike
karakteristike n=f(M) su prave
linije i njihov oblik je prikazan na
sl. 1-23.
Ako se zanemari pad napona na
etkicama vai i relacija:
n E
=
n0 U a
Ova relacija daje mogunost da
se umesto relativne vrednosti
brzine posmatra relativna vrednost
EMS. Ovo e biti iskorieno pri
crtanju karakteristika DC motora
napajanog iz opera razliitih
klasa. Kod maina iz opsega snaga
od 1 do 100 kW pad napona u
rotorskom kolu pri nominalnoj
struji (RaIa,n) je u granicama od
3% (velike maine) do 8 % (male
maine). I pad brzine je u tim
sl.1-23. granicama. Kod brzih promena
33
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
34
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
35
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
36
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
E n tON a 2U I T 1
= = = =
U I n0 tON + t2 a 2U I T + 2 La I a ,sr ,disk . 2L I I
1 + 2 a n a ,sr ,disk .
a U IT In
Do bijene relacije pokazuju da u reimu diskontinualne struje, mehanike
karakteristike imaju oblik hiperbole koja see ordinatu u taki koja odgovara ulaznom
naponu UI (n0). Vertikalna asimptota ove hiperbole je u drugom kvadrantu osim pri
a=0 kada se poklapa sa osom.
Da bi se dobila granica izmeu ova dva reima treba poi od jednaina:
Im Im I
U i E = La ; E = La ; I a ,sr , gr . = m
tON T tON 2
Njihovim reenjem dobija se:
TE (U I E ) TU I E E 2 TU n n 2
I a ,sr ,gr . = = = I
2 LaU I 2 La U I U I 2 La no no
Granina linija ima oblik kvadratne parabole ije je teme:
TU I E
I a ,sr ,gr ,max = ; = 0,5
8La UI
Maksimala vrednost diskontinualne struje (i momenta) ima se pri E=0,5UI. Ova
vrednost je direktno proporcionalna ulaznom naponu, a obrnuto prekidakoj
frekvenci i induktivnosti rotorskog kola. Brzina praznog hoda kod DC motora sa
nezavisnom pobudom ili sa permanentnim magnetima, je proporcionalna sa EMS, a
moment struji. Zbog toga mehanike karakteristike n=f(M), imaju isti oblik kao i
karakteristike E=f(Ia). Na sl. 1-26, prikazani su oblici ovih karakteristika,
normalizovani na nominalnu struju (Ia,n) i ulazni napon (UI). U reimu kontinualne
struje karakteristike su paralelne i blago nagnute. Ovaj nagib nastaje zbog pada
napona na rotorskom otporu (Ra). Pri malim faktorima ispune, mehanike
karakteristike mogu da se nau i u etvrtom kvadrantu. Ovo je oblast dinamikog
koenja. EMS je promenila smer ali srednja vrednost napona nije, pa je pretvara jo
uvek u prvom kvadrantu.
U krajnjem sluaju pri a=0, srednja vrednost napona je nula (-UD). Drugi krajnji
sluaj rada je pri a=1, kada je tranzistor ukljuen sve vreme. Ako se rotor obre
nekim drugim motorom iznad brzine praznog hoda (n>n0), struja pada na nulu, pa se
radna taka nalazi na vertikalnoj osi (E/UI).
Za razliku od maine, oper radi samo u prvom kvadrantu, i to u oblasti izlaznih
napona od Ua=0 (pri a=0), do Ua=UI (pri a=1). Prevezivanjem krajeva rotora ili
pobude, dobija se suprotan smer obrtanja i rad u treem kvadrantu.
Za upravljanje tranzistorskim operima, najee se koriste impulsi konstantne
periode (T) a promenljive irine (PWM). Drugaiji oblici impulsa, daju i druge oblike
granine linije.
37
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
38
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
U reimu kontinualne struje (sl. 1-28a), srednja vrednost napona i EMS su;
T tON
U a ,sr ,kont . = U I = U I (1 a )
T
Ea = (1 a )U I Ra I a
Posmatrajmo sada reim diskontinualne struje (sl. 1-28b). Kada je tranzistor
ukljuen, rotorsko kolo je kratko spojeno i uz zanemarenje omskog otpora (jer je
T<<La/Ra) vai:
I a ,m ,disk .
E = La
t2
Kad je tranzistor iskljuen, dok postoji struja vodi zamajna dioda i energija se
vraa u izvor napajanja pa vai relacija:
I a ,m
U I E = La
tON
Srednja vrednost struje je:
I a ,m tON + t2
I a ,sr ,disk . =
2 T
Posle sreivanja dobija se:
a 2T E 2
I a ,sr ,disk . =
2 La U I E
Da bi se dobila granica izmeu ova dva reima treba poi od jednaina:
I a ,m I I
E = La ; U I E = La a ,m ; I a ,sr , gr . = a ,m
tON T tON 2
Njihovim reenjem dobija se:
T E (U I E ) T U I E E 2 T U I n n 2
I a ,sr , gr . = = =
2 La U I 2 La U I U I 2 La no no
Granina linija ima oblik kvadratne parabole ije je teme:
TU I E
I a ,sr , gr ,max = ; = 0,5
8La UI
I ovde je faktor ispune definisan na isti nain kao ranije a=tON/T. Negativan znak
znai da se radi o struji suprotnog smera. I smer momenta je suprotan pa maina radi
u reimu rekuperativnog koenja.
39
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
40
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
41
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
42
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
43
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
I a ,sr ,disk . =
(2a 1)T U I U I E
4 La E
Granina linija ima oblik:
T U I E E
2
I a ,sr , gr . =
I I
4 La U U
44
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
I a ,sr ,disk . =
(1 2a )T E2
2 La UI + E
Granina linija ima oblik:
T U I E E
2
I a ,sr , gr . =
4 La U I U I
Ovo je parabola sa temenom:
TU I E
I a ,sr , gr ,max . = ; = 0,5
16 La UI
Ovde maina radi u etvrtom
kvadrantu. Primer ovakvog rada
je sputanje tereta kod dizalice,
pri emu je smer obrtanja rotora
suprotan od smera pri podizanju.
Moment je u oba sluaja
pozitivan. Pri radu u etvrtom
kvadrantu maina radi u
generatorskom reimu i
mehaniku energiju pretvara u
elektrinu a pretvara je
prebacuje od generatora, izvoru
napajanja. Da bi ovakav rad bio
mogu, izvor treba da ima
mogunost prihvatanja ove
energije (kao na primer
akumulatorska baterija).
Na sl. 1-35 su prikazane
mehanike karakteristike, za rad
sl. 1-35. u oba kvadranta i oba reima
struje.
45
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
46
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
47
Radojle Radeti, Prekidaka napajanja, 1. Jednoimpulsni direktni pretvarai
48
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
49
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
50
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
51
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
52
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
53
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
54
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
55
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
komplikovaniji i skuplji.
Jednotranzistorski forward pretvara se
koristi kod napojnih jedinica snaga ispod
250 W a dvotranzistorski ide i do 400 W.
U odnosu na flyback ovaj pretvara se
koristi za vea strujna optereenja.
Na kraju treba uoiti da primarno
energetsko kolo ovog pretvaraa ima isti
broj komponenata kao polumostni
sl. 2-5. pretvaraa koji omoguava veu izlaznu
snagu i bolje iskorienje transformatora.
1.1.3. PRIMERI FORWARD PRETVARAA
Na sl. 2-6. prikazano je jedno konkretno reenje pretvaraa tipa forward snage 60
W. Pretvara je klasinog tipa sa tercijarnim namotom za resetovanje jezgra. etvrti
namot slui za pobudu tranzistora. Poetna pobuda se dobija iz ulaznog napona preko
otpornika od 47k, posle ega je odrava indukovani napon pobudnog namota. Vreme
ukljuenosti tranzistora (tON) pretvaraa definie kondenzator od 4n7 na oko 15 s,
tako da je frekvencija pretvaraa oko 30 kHz. Otpornik od 0,5 preko pomonog
tranzistora (BC337) titi pretvara od preoptereenja tako to dodatno skrauje vreme
tON. Za ovaj forward, ovo je pretvara srednje snage. Ispravlja je izveden bez
prigunice i punjenje kondenzatora je samo u intervalu vremena tON.
Na sl. 2-7 prikazan je primer ovakvog pretvaraa snage 250 W, ulaznog napona
320 V. Pretvara radi na frekvenciji 40 kHz i na izlazu daje struju do 50 A pri naponu
od 5 V.
sl. 2-6.
56
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
57
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
58
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
pad napona je oko 0,4 V. Pri veoma niskim izlaznim naponima (ispod 5 V) ak i
padovi napona na otki diodama postaju preveliki. Reenje je naeno u sinhronim
ispravljaima sa MOSFET tranzistorima. Na tritu se mogu nai n kanalni
MOSFET-ovi sa RDSon reda 5 m, tako da pri struji od 20 A pad napona na njima
iznosi svega 0,1 V. Sa pet ovakvih tranzistora u paralelnoj vezi (ili IMC tehnika) se i
kod napona reda 5 V, moe postii stepen iskorienja ispravljaa od preko 95 %, pri
strujama od 100A. Nihova ulazna kapacitivnost od nekoliko nF ograiava primenu do
nekoliko stotina kHz do 1 MHz.
Najednostavniji nain upravljanja sinhronim ispravljaima je sopstvena pobuda
koja se vri naponom iz istog transformatora iji se napon ispravlja (sl. 2-9.). Za
pravilan rad ispravljaa potrebno je da napon na geitovima bude oko 10 V, tako da se
ovaj metod moe primeniti samo pri tim sekundarnim naponima transformatorima.
Na primer sa pretvaraem tipa forward, i ispunom impulsa aMAX=0,5, maksimalni
izlazni napon je oko 5 V. Pored toga, ovo suava i opseg ulaznih napona pretvaraa.
Treba uoiti da ovde
tranzistori rade u III
kvadrantu (inverzan
polarizacija). Ako se na
gejtove MOSFET-ova ne bi
dovodili upravljaki
impulsi, vodile bi samo
parazitne diode njima. Ovo
sl. 2-9. bi bio klasian forward
pretvara (padovi napona na diodama neto manji od 1 V). Meutim ako se dovode i
upravljaki impulsi, diode se premoavaju tranzistorima i pad napona na njima
postaje znatno manji. Kod pretvaraa postoji i mrtvo vreme (t3), kada nema
indukovanog napona. Tada vode samo diode i stvaraju se veliki gubici. Zbog toga,
ali i zbog slabih dinamikih karakteristika parazitne diode u MOSFET-u, paralelno se
moe dodati spoljna otki dioda. Takoe kola snabera i razni R-C lanovi deformiu
indukovani napon tako da izazivaju smetnje u uravljanju MOSFET-ovima. Izvesno
pobiljanje postignuto je aktivnim premoenjem struje magnetizacije (ACR tehnika)
umesto snaber kola, ime se dobijaju kvadratni indukovani naponi koji su blii
teorijskim oblicima. Problem sa pobudom moe se izbei posebnim drajverskim
kolom za upravljanje tranzistora sinhronog ispravljaa.
Ova tehnika ispravljanja razvijena je za potrebe napajanja savremenih
mikroprocesora koji rade pri naponima reda 3 V ali zahtevaju velike struje (desetine
ampera). Jednostavnost i niska cena ovog naina ispravljanja omoguili su primenu
sinhronih ispravljaa i na mestima o kojima se ranije nije ni razmiljalo. Tako na
primer sada je mogue napraviti punjae akumulatorskih baterija velikih kapaciteta i
to za po jedan lanak (na primer 2,4 V i 70 A). Ovakvi ispravljai pogodni su pri
ispitivanju kapaciteta baterija. Drugo mesto bi bilo na primer kod instrumenata za
merenje prelaznih otpora kontakata kod ispitivanja visokonaponske opreme (potrebna
struja od oko 100 A pri naponu od oko 3V) i td.
59
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
60
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
I 2
n
THDI = n =2
I12
61
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Veza izmeu totalnog harmonijskog izoblienja struje (THDI) i faktora snage je:
1 THDI 2
= 1
1 + THDI 2 2
Na primer kod THDI=0,25, faktor snage je oko 0,97.
Sve navedeno govori u prilog potrebe za popravljanjem faktora snage (PFC).
Tokom vremena ovaj problem je reavan na razne naine. Danas se oni mogu
podeliti na pasivne i aktivne metode PFC.
Kod pasivnih metoda teilo se da se interval struje to vie proiri i struja priblii
sinusoidi. Neki od ovih naina sastoje se u dodavanju redne prigunice ili
kondenzatora ispred diodnog mosta. Koristi se i redna prigunica izmeu mosta i
elektrolotnog kondenzatora, razni filtri itd. Svi ovi elementi rade na mrenoj
frekvenciji (50 Hz ili 60Hz), tako da su gabaritno veliki, teki i skupi.
Bolji rezultati postignuti su aktivnim metodama PFC. Jednostavniji pokuaji
sastojali su se u faznoj regulaciji ulaznog napona uz dodatak rednih prigunica. Oni
su nazvani aktivnim niskovrekventnim PFC. Meutim bolji rezultati postignuti su uz
pomo visokofrekventne aktivne PFC.
Poloaj bloka PFC, unutar jedne napojne jedinice, prikazan je na sl. 2-12. Kao to
se vidi, on je smeten izmeu diodnog mosta i kondenzatora. Blok za PFC pretstavlja
dodatni pretvara upravljan istovremeno ulaznim i izlaznom naponom tako da dovede
ulaznu struju to blie sinusnom obliku. Blok ema upravljanja blokom za PFC
prikazana je na sl. 2-13. Referentnim naponom i razdelnikom izlaznog napona
definie se njegova visina. Regulator izlaznog napona je PI tipa. Izlazni signal greke
(Y) iz ovog regulatora se modulie (mnoi) sa ispravljenim sinusnim naponom (X) i
njihov proizvod (ZY) komparira sa
padom napona na entu (strujom).
Izlazni napon ovog komparatora je
sl. 2-12. novi signal greke koji upravlja
blokom impulsno irinske modulacije
(PWM) koji konano upravlja
pretvaraem za PFC.
U principu pretvara za PFC moe
da bude bilo koji od jednoimpulsnih
pretvaraa. Zbog svojih specifinosti,
danas se ovde najvie koristi pretvara
tipa boost (sl. 2-14.). On ima
kontinualnu ulaznu struju to ga ini
veoma pogodnim za ovu primenu.
Njegov izlazni napon je vei od
ulaznog tako da se kondenzator puni
na relativno visok napon. Da bi struja
bila kontinualna izlazni napon mora
sl. 2-13. biti vei od amplitude maksimalnog
62
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
ulaznog napona. Na primer kod ureaja napajanih iz mree 220 V ovaj napon je
obino oko 380 V, to omoguava pravilan rad PFC i pri ulaznim AC naponima do
270 V. Donja granica napona je obino dovoljno niska da omoguava rad i pri
mrenom naponi od 110 V, bez ikakvog posbnog prilagoenja.
Vii harmonici ulazne struje imaju visoku frekvenciju i relativno lako se blokiraju
kondenzatorim malog kapaciteta na ulazu ili jo bolje ulaznim filterom (EMI).
Za ove primene na tritu se nudi veliki broj integrisanih upravljakih kola. U
prilogu, na kraju knjige, prikazano je nekoliko primera PFC tehnike.
sl.2-14.
1.2. PRETVARA TIPA FLYBACK
Zbog nekih svojih dobrih osobina ovaj tip pretvaraa se danas iroko primenjuje,
kod mrenih stepena u TV aparatima, napajanja raunara, napojnih jedinica opte
namene (snaga do oko 250 W) i slino. Naroito je pogodna njegova primena u
sluajevima kada je na izlazu potreban vei broj napona (vie sekundara u
transformatoru). Za razliku od pretvaraa tipa forward, flyback pretvara se koristi
dobijanje manjih izlaznih struja (ispod 10 A).
Smatra se da naziv flyback potie od nekadanje primene ovog pretvaraa za
brzo vraanje elektronskog mlaza u katodnim cevima, na poetak.
Osnovna konfiguracija ovog pretvaraa prikazana je na sl. 2-15. Za razliku od
prethodnog, ovde je sekundar transformatora vezan suprotno. To se vidi kroz poloaj
taaka za smer motanja. Druga razlika je u samoj konstrukciji transformatora. Jezgro
transformatora izvedeno je sa zazorom, tako da on ima veliku struju magneenja a
samim tim i mogunost akumulacije velike energije. Uzimanje energije (i
akumulacijau zazoru jezgra) se vri u jednom a predaja optereenju u drugom
vremenskom intervalu, tako da transformator ovde radi kao spregnuta prigunica.
Zbog toga, nije potrebna dodatna prigunica u izlaznom ispravljau.
Postoji vie varjanti flyback pretvaraa. Pored osnovne konfiguracije u kojoj
tercijar slui za vraanje energije u izvor napajanja, koriste se i eme bez tercijara.
Iz istih razloga kao i kod pretvaraa tipa forward, i ovde e biti zanemaren pad
napona na ukljuenom tranzistoru ali e se uzeti u obzir pad napona na ispravljakoj
diodi u skundarnim kolu.
Dalje e ukratko biti objanjen princip rada pretvaraa u osnovnoj konfiguraciji.
63
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
L1 (I12,MAX I12,MIN )
1
WON =
2
Ako pretvara radi u reimu diskontinualne struje, onda je porast struje ujedno i
njena amplituda (jer je I1,MIN=0).
UI U a
I1,DISC = I1,MAX = tON = I
L1 L1 f
Pri konstrukciji pretvaraa, promena struje (valovitost) je jedan od polznih
podataka i iz ove relacije se onda dreuje potrebna induktivnost.
2 WON 2 PMAX 2 PMAX
L1 = = L1 =
f (I1,MAX I12,MIN )
, ili
I2
I1,MIN
1, MAX
2 2
f I12,MAX
Pri diskontinualnom radu energija akumulisana u intervalu tON je:
64
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
1
WON = L1 I12,MAX
2
Kada se tranzistor iskljui (interval tOFF), akumulisana energija u intervalu tON
prenosi se na izlaz pretvaraa ili se vraa preko tercijara u izvor napajanja.
Kada se sva akumulisana energija prenese optereenju, pretvara postie
maksimalnu snagu i ona je:
PMAX = WON f
U intervalu tOFF, naponi na pojedinim namotima su:
N1 N
U1 = (U O + U D ) , U 2 = U O + U D U 3 = (U O + U D ) 3
N2 N2
Sve dok je napon U3 nii od ulaznog, ne postoji struja tercijara i sva snaga se
prenosi na sekundar. Preslikavanje izlaznog napona na ostale namote je osobina koja
se moe iskoristiti za upravljanje pretvaraem po ovom naponu.
Pri ovoj snazi, izlazni napon i struja zavise od otpornosti potroaa.
PMAX
UO = = PMAX RO
IO
Sa smanjenjem njegove otpornosti izlazna struja raste a napon opada. Da nebi
dolo do oteenja treba da postoji strujni limit, koji dalje odrava IMAX, poveava
tOFF i time smanjuje frekvenciju. Ovo je oblast u kome je izlazni napon jako mek i ne
postoji nikakva stabilizacija.
Pri nazivnom optereenju ipak se oekuje od pretvaraa da ima bar neku vrstu
stabilisanog napona. Jednostavniji oblik stabilizacije je stabilnost prema promeni
optereenja. Kompletnija stabilizacija obuhvata i stabilnost prema promenama
ulaznog napona.
Kod osnovne verzije pretvaraa moe se postii stabilizacija prema promeni
optereenja. Ona se postie tako to pretvara radi sa snagom manjom od
maksimalne, a ostatak energije se preko tercijara vraa izvoru napajanja.
Vraanje energije u izvor napajanja postie se kada napon tercijara postane jednak
ulaznom. Tada je na izlazu napon maksimalan i vai relacija:
N3
U 3 = U I = (U O ,MAX + U D )
N2
Odavde se dobija visina izlaznog napona:
N2
U O ,MAX = U I UD
N3
Izlazni napon vie ne zavisi od optereenja tako da je postignuta ova vrsta
stabilizacije. Meutim pri promenama ulaznog, menja se i izlazni napon.
65
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
66
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Pri ukljuenom tranzistoru transformator prenosi energiju na izlaz preko dioda D3,
D4 i prigunice. Ujedno se vri akumulacija energije u zazoru jezgra. Pri iskljuenom
tranzistoru i ovaj deo energije se prenosi na izlaz preko dioda D1 i D2. Na ovaj nain
postie se jo vea snaga, bolje iskorienje transformatora ali i usloava pretvara
dodavanjem tri nove diode i prigunice. Broj dioda se moe smanjiti uvoenjem
srednjeg izvoda na sekundaru transformatora (kao kod push-pull-a). Dodatni problem
pretstavlja ujednaavanje
sekundarnih struja pri forward i
flyback prenoenju snage.
Ovaj i slini pretvarai nisu
tipini i u njihovu detaljniju
analizu se nee ulaziti.
Sl. 2-18 prikazuje sinhroni
ispravlja kod flyback
sl. 2-18. pretvaraa.
1.2.2. FLYBACK PRETVARAI BEZ VRAANJA ENERGIJE
Osnovna verzija pretvaraa imala je nedostatke:
- Nije sva akumulisana energija mogla biti iskoriena, ve je deo vraan izvoru
- Slabije iskorienje transformatora
- Postignuta je samo stabilizacija izlaznog napona na promene optereenja
U praksi je najee potreban stabilisan izlazni napon ili stuja. Povratnim spregama
sa flyback pretvaraima je postignut rad u veoma irokom opsegu ulaznih napona (na
primer u opsegu 1:3).
Povratna sprega po naponu poredi referentni i izlazni napon, i na osnovu razlike
odreuje veliinu koeficijenta ispune ciklusa (a). Iz izvora napajanja uzima tano
onoliko energije koliko je potrebno optereenju, tako da se nita ne vraa nazad.
Zbog toga vie nije potreban tercijar i ve samo samo primar i sekundar (sl. 2-19),
to omoguava da oni zauzmu po polovinu prozora (k1=0,5), ime se poboljava
iskorienje transformatora i postie vea snaga. Dalje e biti analizirani ovakvi
pretvarai ne ulazei u nain njihovog upravljanja.
I ovde pretvara moe raditi u reimu kontinualne ili diskontinualne struje.
Na sl. 2-20 su prikazani vremenski dijagrami karakteristinih struja i napona ovog
pretvaraa, za reim rada sa kontinualnom
strujom. Na prvom dijagramu je
isprekidanom linijom naznaena gornja
granica napona tranzistora u osnovnoj
varjanti pretvaraa (sa tercijarom). Kod
pretvaraa sa povratnom spregom, ova
granica ne postoji. Visinu izlaznog napona
odreuje povratna sprega. Zbog boljih
karakteristika i ee primene, ovaj
pretvara e biti detaljnije razmatran.
sl. 2-19.
67
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Interval tON
Kada je tranzistor ukljuen (interval tON), primar je doveden pod puni ulazni
napon. Indukovani napon sekundara je negativan tako da dioda (D2) ne provodi
struju. Naponi pojedinih namota su:
N2
U1 = U I , U 2 = U I
N1
Zbog toga sva primarna struja odlazi na
magneenje jezgra i vazdunog zazora u
njemu. U ovom intervalu transformator ne
prenosi nikakvu energiju na sekundar ve
radi kao prigunica induktivnosti L1, u
primarnom kolu.
Primarna struja raste linearno i na kraju
intervala tON, njen porast je:
UI U a
I1 = I1,MAX I1,MIN = tON = I
L1 L1 f
f=1/T frekvencija
Kad postoji regulacija izlaznog napona
menja se koeficijent ispune ciklusa (a).
Maksimalni porast struje ima se pri aMAX.
U I a MAX
I1,MAX =
L1 f
sl. 2-20. Pri konstrukciji pretvaraa, promena
struje je jedan od polznih podataka i iz ove
relacije se onda dreuje njena induktivnost.
UI U I a MAX
L1 = t ON , MAX =
I 1, MAX I 1, MAX f
Pri maksimalnoj striji (I1,MAX), indukcija u jezgru je maksimalna i iznosi:
N 1 I1,MAX N I
BMAX = 0 1 1,MAX
l MAG
lMAG Duina linije magnetnog fluksa u jezgru
Zazor u jezgru transformatora
Za definisanu maksimalnu vrednost struje, indukciju (oko 0,3 T) i broj navojaka
primara, moe se odrediti zazor u jezgru.
N 1 I1,MAX
0
BMAX
68
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Dalje se moe uspostavit veza izmeu veliine zazora i dimenzija jezgra i to e biti
uraeno za konkretne sluajeve.
Maksimalna primarna struja (I1,MAX je ujedno i maksimalna kolektorska struja
tranzistora i slui za njegov izbor.
I C ,MAX > I1,MAX
Zbog iskljuenja tranzistora u trenutku kada je struja maksimalna, potreban je jak
snaber na prekidakom tranzistoru.
Interval tOFF
Kada se tranzistor iskljui, u zazoru transformatora ostaje akumulisana energija
tako da struja tei da nastavi svoj tok. Primarni menja polaritet, tako da napon
kolektora poraste iznad ulaznog napona. Istovremeno menja se polaritet i
sekundarnog namota. Sa ovim poinje novi vremenski interval, tOFF. Na sekundaru se
sada indukuje pozitivan napon i struja se zatvara kroz diodu D2 i izlazni kondenzator.
U trenutku prebacivanja struje sa primara na sekundar, zbog nesavrene magnetne
sprege, indukuje se kratak prenaponski impuls na primaru.
U intervalu tOFF, indukovani naponi pojedinih namota su:
N1
U1 = (U O + U D ) , U 2 = UO + U D
N2
Napon na tranzistoru je:
N2
U CE = U I + (U O + U D )
N1
Tranzistor se bira tako da podnese i dodatni indukovani prenapon, pri prekidanju
primarne struje.
N2
U CE ,MAX = U I + (U O ,MAX + U D ) + Indukovani prenapon
N1
Visina indukovanog prenapona ograniava se RC, (ili RCD) kolom, vezanim
paralelno sa primarom transformatora. Sve ukupno veliina kolektorskog, ide i preko
dvostruke vrednosti ulaznog napona. Na primer za pretvarae napajane ispravljenim
mrenim naponom 220 Vac (310 Vdc) kolektorski napon tranzistora treba da bude vii
od 600 V. U nekim sluajevima koriste se tranzistori sa UCE,MAX i do 1500 V
(BU508). Radi smanjenja gabarita ovih elemenata, potrebno je da rasipna
induktivnost izmeu primara i sekundara bude to manja.
U ovom intervalu, akumulisana energija se preko sekundara predaje kondenzatoru i
potroau.
Primarna struja je pala na nultu vrednost (diskontinualna), a odravanje
namagneenosti preuzima struja sekundara. Sekundarna struja poinje od maksimalne
i opada linearno do minimalne ili ak do nulte vrednosti. Ako struja padne do nulte
vrednosti, govori se o reimu sa diskontinualnom strujom. U suprotnom se ima reim
69
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
70
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
I EF =
a 2
I MAX + I MIN
2
+ I MAX I MIN =
a
(I MAX + I MIN ) 1 I MIN I MAX 2
3 3 (I MAX + I MIN )
71
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
I1,EF
a
(I MAX + I MIN ) 3 = a I MAX + I MIN = J S1,Cu
3 4 2
pa je:
I MAX + I MAX tON t
JSCu ON = JSCu a
2 T T
Uvaavajui da je:
N 1 SCu = k S PR
Namoti primara i sekundara imaju sline oblike struje, tako da zauzimau po
polovinu prostora u prozoru jezgra (k1=0,5). Sa koeficijentom ispune prozora bakrom
od kCu=0,4, dobija se k=k1 kCu=0,50,4=0,2.
Posle sreivanja dobija se snaga transformatora:
I MAX + I MAX tON 1 1
PCONT = U I = N 1B f S Fe SCu J = k f B S Fe S PR J
2 T a a
Uvaavajui za gustinu struje da je:
J = 4,5 105 ( S FE S PR ) 1/ 8 = 4,5 106 [S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
Ili
J ( A / mm 2 ) = 4,5[S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
Sada je snaga:
1
PCONT = 4,5 105 k B f ( S FE S PR ) 7 / 8
a
Posle streivanja i reenja po proizvodu povrina dobija se:
8/7 1,143
2,2 10 6 PCONT tON 2,2 10 6 PCONT
S FE S PR = = a
k f B T k f B
Ovaj proizvod odreuje se prema maksimalnoj snazi (aMAX).
Za povrine izraene u cm2 izraz postaje:
1,143
22 PCONT
S FE ( cm ) S PR ( cm ) =
2 2
a MAX
k f B
Za k=0,2 i aMAX=0,5 izraz postaje:
72
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
73
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
74
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Ili
75
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
J ( A / mm 2 ) = 4,5[S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
Sada je snaga:
1 1
PDISC = 0,866k f Bm S Fe S PR J = 3,9 105 k f Bm ( S FE S PR ) 0,875
a a
Posle streivanja i reenja po proizvodu povrina dobija se:
1,143 1,143
2,6 10 6 PDISC tON 2,6 10 6 PDISC
S FE S PR = = a
k f BMAX T k f BMAX
Za maksimalnu snagu (pri a=aMAX) i povrine izraene u cm2 izraz postaje:
1,143
26 PDISC
S FE ( cm 2 ) S PR ( cm 2 ) = a MAX
k f B MAX
Za k=0,2 i a=0,5 izraz postaje:
1,143 1,143
92 PDISC P
S FE ( cm ) S PR ( cm ) =
2 2
= 175 DISC
f B MAX f BMAX
Za BMAX=0,25T izraz postaje:
1,143 1,143
36 PDISC P
S FE ( cm ) S PR ( cm ) =
2 2
= 60 DISC
f f
Sada se za potrebnu snagu poznatu frekvenciju i BMAX izraunava vrednost SFeSPR.
Dalje se iz kataloga bira prvo vee jezgro.
Broj navojaka primara je:
U I tON ,MAX U I a MAX 5000 U I
N P ,MIN = = 10 4 =
B S FE BMAX S FE ( cm ) f
2
BMAX S FE ( cm 2 ) f
Brojevi navojaka sekundara (i drugih namota) moe se odrediti proporcionalno
svojim naponima. Sada jo treba odrediti preseke provodnika ovih namota. To se radi
na osnovu poznatih efektivnih vrednosti struja pojedinih namota i gustine struje
izraunate za veliinu odabranog jezgra.
Sada se moe izraunati i veliinu zazora u jezgru ().
N 1 I1,MAX N J S1,Cu 3 k J S PR 3
= 0 = 0 1 = 0
BMAX BMAX a BMAX a
Za k=0,2 i a=0,5 izraz postaje:
J S PR
= 6,1 10 7
BMAX
76
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
Ili u milimetrima:
J ( A / mm 2 ) S PR ( cm 2 )
( mm) = 0,061 0,2 J ( A / mm 2 ) S PR ( cm 2 )
BMAX
U poslednjem izrazu pretpostavljeno je da je amplituda indukcije BMAX=0,3 T.
Na ovaj nain je izraunat ukupan zazor koji se ponekad sastoji od dva jednaka
zazora i u tom sluaju svaki pojedinani je polovina ovako izraunatog.
Ove relacije su izvedene pod pretpostavlom da je:
l Fe
>>
r
Ukoliko to nije sluaj onda dobijeni zazor treba umanjiti za vrednost lFe/r.
0.0.0.0. Uporeenje snaga
Interesantno je uporediti snage ovih transformatora (istih dimenzija) sa
standardnim transformatorom (mostni pretvara).
PCONT 4,5 105 k f B ( S FE S PR ) 0,875 2 B I
= = 0,35 = 0,35 0,31
PMOST 18 10 k f Bm ( S FE S PR )
5 0 ,875
Bm I MAX
PDISC 3,9 105 k f Bm ( S FE S PR ) 0,875 2
= = 0,31
PMOST 18 105 k f Bm ( S FE S PR ) 0,875
Meusobni odnos snaga flyback transformatora transformatora je:
1
4,5 105 k f B ( S FE S PR ) 0,875
PCONT
= a = 4,5 B = 1,15 B = 1,15 I < 1
PDISC 1 3,9 Bm BMAX I MAX
3,9 105 k f Bm ( S FE S PR ) 0,875
a
Izraz pokazuje da pri maloj promeni struje prgunice (I) transformator ima manju
snagu nego pri diskontinualnoj stuji sa IMAX.
0.0.0. PREDNOSTI I MANE FORWARD PRETVARAA
Dobre osobine ovih pretvaraa su:
- minimalni broj komponenata
- mogue postojanje vie izlaznih napona
- smanjena kolektorska struja u zavisnosti od odnosa transformacije
- galvanska odvojenost ulaza i izlaza itd.
Nedostatci:
- slab tranzijentni odziv
- velika valovitost izlaznog napona
- kritina izrada transformatora
77
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
78
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
sl. 2-23.
sl. 2-24.
sl. 2-25.
79
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
sl. 2-26.
sl. 2-27.
80
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
sl. 2-29.
81
Radojle Radeti, Prekidaka napajanja, 2. Jednoimpulsni indirektni pretvarai
2
N
C2 = C1 1 = 2 C
N2
Pri ovom odnosu, nazivni naponi sprenih kondenzatora treba da budu:
U C1 > U I , UC 2 > UO
Ovaj odnos nije neophodan.
Naponi kondenzatora C1 i C2, su UIN i UO respektivno.
I induktivnosti L1 i L2 se odnose kao kvadrati broja navojaka.
2
L1 N 1
=
L2 N 2
Izbor filterskog kondenzatora vri se na isti nain kao kod ukovog pretvaraa bez
transformatora.
U tenji za daljom minijatirizacijom pretvaraa, transformator i induktivnosti
pravljeni su i na zajednikom feritnom jezgru (oblika EE).
Originalnost reenja i odline karakteristike pretvaraa, doneli su slavu svom
pronalazau, a njegovom pretvarau omoguili primenu ak i na Space Shuttle-u.
Prema lit. 3. pretvara za Space Shuttle, iz 1982. godine je snage 2 kW sa
ulaznim naponom 200 20 Vdc, izlazni napon 32 4 Vdc i struja 60 A. Pretvara
radi na frekvenciji 100 kHz i pri tome je postignuta efikasnost od oko 92 %. Kao
prekidaki tranzistori koriena su etiri paralelna tranzistora tipa IRF450.
Transformator je prenosnog odnosa 4:1. Transformator je napravljen sa jezgrom
EI50 proizvodnje TDK sa feritom tipa H7C1. Primar ima 12 navojaka folije
dimenzija 15 x 0,13 mm. Sekundar je takoe folijski sa tri navojka od 4 x (15 x 0,13
mm).
Kondenzatori su: C1 =5 F i C2=80 F i C3=2800 F.
Induktivnosti L1 i L2 su spregnute i njihove veliine su: L1=260 H i L2=16 H.
Na slian nain na koji je izvedena verzija ovog pretvaraa sa transformatorom, to
se moe uraditi i sa pretvaraem tipa SEPIC ali to dalje neemo analizirati.
0.0.0. PREDNOSTI I MANE
Dobre osobine ovih pretvaraa su:
- kontinualne, ulazna i izlazna struja
- visoka efikasnost, mali broj prekidakih komponenata
- visoka radna frekvenca
- bazno kolo na potencijalu mase i td.
Nedostatci:
- kondenzatori C1 i C2 trpe jake strujne impulse
- kritina konstrukcija transformatora
- ograniena izlazna snaga i td.
82
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
2. DVOIMPULSNI PRETVARAI
Kod dvoimpulsnog pretvaranja DC/DC, radi se o indirektnom dvostepenom
pretvarau sastavljenom od invertora i ispravljaa (DC/AC+AC/DC). Izmeu ova dva
pretvaraa obino se nalazi i transformator iji je zadatak da obezbedi galvansku
izolovanost, izvri prilagoenje ulaznog i izlaznog napona. Kod pu-pula je
nepohodan i zbog same konfiguracije. Treba uoiti da je u osnovi dvoimpulsnih
DC/AC pretvaraa ustvari jednoimpulsni, tipa forward koji se opet dalje zasniva na
buck pretvarau. U odnosu na jednotaktne, ovi pretvarai omoguavaju postizanje
veih snaga. Razlog tome je prenoenje energije tokom itave periode. Dvoimpulsni
pretvarai omoguavaju i bolje iskorienje transformatora jer se njegovo
magneenje odvija u opsegu indukcija od -Bm do +Bm odnosno 2Bm. Detaljnije o
ovome bie reeno u poglavlju o invertorima.
Danas se koriste tri vrste invertora i to su: pu-pul, polumostni i mistni. Prema
njima e dalje biti nazvani i kompletni DC/DC pretvarai.
Drugi deo DC/DC pretvaraa ini ispravlja. Ovde postoje dve varjante
ispravljanja. Prva je sa dve diode i srednjim izvodom na transformatoru a druga sa
mostnim ispravljaem. Ispravljanje sa dve diode moe da ide sa ili bez zamajne
diode. Ove varjante sekundarnog ispravljakog kola prikazane su na sl. 3-3.
2.1. PU-PUL (PUSH-PULL) PRETVARA
2.1.1. PRINCIP RADA
Ovaj pretvara omoguava postizanje srednjih snaga. Veoma je pogodan za
primenu gde se napajanje vri niskim ulaznim naponima. Koristi ze za napojne
jedinice snaga do oko 1 kW. Njegova ema prikazana je na sl. 3-1. Pretvara se
sastoji od push-pull invertora i izlaznog ispravljaa.
Invertorski deo se sastoji od dva prekidaka tranzistora i transformatora.
Primar transformatora sastoji se od dva polunamota koji provode struju savaki u
svojoj poluperiodi. Potrebno je da magnetna sprega ova dva polunamota primara
bude to bolja.
Sekundar takoe moe biti sa dva ili tri izvoda u zavisnosti od toga dali e
ispravlja biti sa dve ili etiri diode (grec).
sl. 3-1.
83
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
84
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
N2 I O
I C ,max > IO + + I . max
N1 2
U CE 0 > 2U I + indukovani prenapon
Diode u ispravljau se biraju prema srednjoj vrednosti struje i maksimalnom
inverznom naponu.
I O ,MAX N2
I D1 = I D 2 > ; U RMD1 = U RMD 2 > 2U I
2 N1
sl. 3-3.
85
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
86
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
U I tON ,MAX UI (U O + U D )
N P/2 = = 10 4 , N S / 2 = 104
B S FE 2 B S FE ( cm ) f
2
2 B S FE ( cm ) f
2
I EF =
(I MAX + I MIN )
1
I MIN I MAX (I + I MIN )
MAX
6 (I MAX + I MIN )2
2 2
Pojedinane efektivne vrednosti struja primara i sekundara su:
I1,lEF
(I 1, MAX + I1,MIN )
=
I O ,MAX N 2
, I 2,lEF
I O ,MAX
2 2 2 N1 2
Gustina struje je:
2 4,5 6,4
J ( A / mm 2 ) = =
[S FE ( cm 2 ) S PR ( cm 2 )]
1/ 8
[S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
87
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
(U O + 2 U D ) (U + 2 U D ) 4
NS = 104 O 10
2 B S FE ( cm ) f
2
S FE ( cm 2 ) f
Ovde se samo namot primara motaj sa duplim brojem navojaka i izvodom na
sredini.
Dalje se odreuju preseci provodnika ovih namotaja. Efektivna vrednost struje je:
I EF =
(I MAX + I MIN )
1
I MIN I MAX
(I MAX + I MIN )
6 (I MAX + I MIN )2 2 2
Pojedinane efektivne vrednosti struja primara i sekundara su:
I1,EF
(I 1, MAX + I1,MIN )
=
I O ,MAX N 2 I
, I 2,EF O ,MAX
2 2 2 N1 2
Gustine struja nanota su:
2 4,5 6,4
Primara: J 1 ( A / mm 2 ) = =
[S FE ( cm 2 ) S PR ( cm 2 )]
1/ 8
[S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
4,5 4,5
Sekundara: J 2 ( A / mm 2 ) = =
[S FE ( cm 2 ) S PR ( cm 2 )]
1/ 8
[S FE ( cm 2 ) S PR ( cm 2 )]
0 ,125
88
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-4.
89
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-5.
Na srednjoj taki kondenzatora je polovina ulaznog napona. Na drugoj
(tranzistorskoj) strani primara transformatora napon ide od nule do UI. Kad je
ukljuen T1, napon na ovom prikljuku primara jednak je ulaznom a napon primara
jednak polovini ulaznog. Kada je ukljuen T2, napon ovog prikljuka je nula a napon
primara opet polovina ulaznog i suprotnog polariteta. Ako su trajanja ovih intervala
jednaka, napon primara je isto naizmenini sa, pravougaonog oblika, visine jednake
polovini ulaznog.
1
UP = UI
2
Ako se napajanje vri vrstim isfiltriranim jednosmernim
naponom, umesto dva moe se primeniti jedan kondenzator
vezan prema bilo kom polu ulaznog napona. Takva
konfiguracija invertora naziva se asimetrinom (sl. 3-6.).
Primarni napon se preko transformatora prenosi na
sekundar posle ega se vri njegovo ispravljanje i
filtriranje.
Za ispravljanje na raspolaganju stoje tri naina opisana
sl. 3-6. kod push-pull pretvaraa.
Regulacija izlaznog napona se takoe vri promenom
90
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
91
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
92
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
I1,EF
(I 1, MAX + I1,MIN )
=
I O ,MAX N 2
, I 2,EF
I O ,MAX
2 2 2 N1 2
Gustina struje u nanotima je:
4,5 4,5
J ( A / mm 2 ) = =
[S FE ( cm ) S PR ( cm ) ]
2 2 1/ 8
[S FE ( cm ) S PR ( cm ) ]
2 2 0 ,125
93
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-8.
Postoji vie naina upravljanja tranzistorima u mostu invertora. Najednostavniji
nain upravljanja je kada se naizmenino ukljuuju dijagonalni tranzistori. Ovo
pitanje postaje sloenije kada je potrebna regulacija izlaznog napona, i ona se moe
vriti na dva naina. Prvi nain je kao i ranije, skraivanjem trajanja voenja
tranzistora (promena faktora ispune a<0,5). Drugi nainregulacije dobija se
odravanjem a=0,5 i promenom vremenskog pomaka voenja tranzistora u suprotnim
granama. Prvi nain je jednostavniji i esto zadovoljava zahteve DC/DC pretvaraa.
Ova regulacija izlaznog jednosmernog napona vri se promenom trajanja
ukljuenosti tranzistora (tON) u odnosu na trajanje poluperiode. Sa upravljanjem na
ovaj nain, istovremeno vode po dva tranzistora (intervali tON), ili dve diode (intervali
tOFF). Kondenzator u primaru onemoguava prolazak jednosmerne komponente struje.
Pretvara radi na sledei nain:
Za referentni smer naznae na sl. 3-8, kada su ukljueni tranzistori T1 i T4 (interval
tON), napon na primaru je pozitivan i jednak ulaznom (UP=UI). Primarna struja se
sastoji od transformisane struje optereenja i struje magneenja. Jezgro
transformatora se pravi tako da struja magneenja bude to manja. Zbog toga e ova
struja u daljim razmatranju biti zanemarena. Na sekundaru se indukuje pozitivan
napon i snaga se preko diode D5 prenosi kondenzatoru i optereenju. Ovaj interval je
deo pozitivne poluperiode.
Pri prekidanju primarne struje pojavljuje se uticaj i rasipne induktivnosti primara.
Energija akumulisana u njoj mora da se isprazni tako da za trenutak provedu diode D2
i D3 preko kojih se ova energija vraa izvoru napajanja. Tada je na primaru negativan
94
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
95
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
N 2 tON N N
UO = U I = U I f tON 2 = U I a 2
N1 T N1 N1
Prekidaki tranzistori, biraju se prema maksimanom naponu UCE0 i kolektroskoj
struji i iznose:
U CE 0 > U I
N2 I L
I C ,MAX > IO + + I ,MAX
N1 2
Maksimalni inverzni naponi dioda zavise od naina ispravljanja.
Mostno isptavljanje:
N2
U RMD ,14 > U I = U O ,MAX
N1
Ispravljanje sa dve diode:
N2
U RMD1 = U RMD 2 > 2 U I = 2 U O ,MAX
N1
Za obe vrste ispravljanja diode se biraju
prema istoj struji:
IO
ID >
2
Na sl. 3-8 prikazan je ovaj pretvara u
varjanti sa dvofaznim sekundarom i
ispravljaem sa dve diode. Na sl. 3-9, prikazani
su vremenski dijagrami najkarakteristinijih
veliina pretvaraa sa ovim ispravljaem. Za
ostale vrste ispravljaa dijagrami su isti kao oni
prikazani kod pretvaraa tipa push-pull.
Bolji regulacija invertora postie se
odravanjem faktora ispune na maksimalnoj
vrednosti (a=0,5) i promenom vremenskog
pomaka voenja tranzistora u suprotnim
granama. Kod ovakvog upravljanja izlazni
napon pretvaraa je definisan u svakom
trenutku i nema intervala voenja samo dioda
mosta. Oblik napona pri ovakvom upravljanju
prikazan je na sl. 3-10.
sl. 3-10.
96
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
97
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
I P ,EF
(I 1, MAX + I1,MIN )
=
I O ,MAX N 2
, I S ,EF
I O ,MAX
2 2 2 N1 2
Gustina struje u nanotima je:
4,5 4,5
J ( A / mm 2 ) = =
[S FE ( cm ) S PR ( cm )]
2 2 1/ 8
[S FE ( cm ) S PR ( cm 2 )]
2 0 ,125
98
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
99
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-13.
100
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
a drugi definie trajanje njenog napona. Tranzistori drugog mosta ne prekidaju struju
ve nju prirodno preuzimaju C2//C4 i odgovarajue diode (aktivan u pasivan prelaz,
A-P). U oba sluaja, uspostavljanje i prekidanje struje vri pri nultim naponima tako
da su komutacioni gubici u tranzistorima mali, zbog ega je mogu rad na viim
frekvencijama (i vie stotima kHz). Ovakav rad naziva se i kvazi-rezonantnim. Pod
odreenim uslovima moe se postii i
rezonantni rad.
Pri malim optereenjima (mala struja i1)
dogaa se da nema dovoljno energije
akumulisane u LC, da se izvri cela
poluoscolacija za P-A prelaz pa se
poveavaju komutacioni gubici na
tranzistorima T1 i T3. Tranzistori T2 i T4
vre A-P prelaz i on se vri sa nultim
naponom pri svim optereenjima.
Pri dovoljno visokoj radnoj frekvenciji
izlazni kapaciteti prekidanih tranzistora i
dioda mosta, moraju se uzeti u obzir. Pri
vrlo vosokom frekvencijama realni
kondenzatori se mogu izostaviti a umesto
sl. 3-14. njih koristiti samo ovi parazitni kapaciteti
prekidakih tranzostora.
0.0.0. REZONANTNI RAD PRETVARAA
Stalno traenje naina za smanjenjem dinamikih gubitaka tranzistora doveli su do
rezonantnog rada pretvaraa.
Prvi korak u smanjenju gubitaka postignut je primenom snabera sa D-R-C
elementima. Sa njima je malo usporeno iskljuenje tranzistora ali je postignuto
njegovo iskljuenje pri manjoj struji. Dalji proces iskljuenja zavisio je od elemenata
snabera. Gubici u aktivnim otpornostima snabera doveli su do pronalaenja
bezdisipativnih snabera sastavljenih od D-L-C elemenata. Zatim se uvidelo da sa L-C
elementima moe da se postigne iskljuenje pri nultom naponu (ZVT) ili nultoj struji
(ZCT). Dobri rezultati u smanjenju dinamikih gubitaka na ovaj nain omoguili su
rad na jo viim frekvencijama. Sa odgovarajuim vrednostima L, C i postojeeg
optereenja, na odreenoj frekvenciji postie se rezonansa. Ona je omoguila rad na
jo viim frekvencijama. Danas pretvarai u rezonantnom radu rade na frekvencijama
od vie stotina kHz pa i nekoliko MHz. To je dalje povealo snagu i smanjilo
dimenzije pretvaraa.
Induktovnosti i kapacitivnosti zajedno sa optereenjem formiraju u optem sluaju
prigueno oscilatorno kolo. Konfiguracije ovog kola mogu biti raznovrsne. Osnovne
konfiguracije sastoje se od redne i paralelne veze ali mogue su i njihove
kombinacije.
O rezonantnom radu kod dvoimpulsnih pretvaraa (invertora) vie u dodatku (5.3).
101
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-16.
102
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
sl. 3-17.
103
Radojle Radeti, Prekidaka napajanja, 3. Dvoimpulsni pretvarai
signal greke utie na PWM. Poto ne mogu istovremeno oba signala greke da vre
upravljanje sa PWM, onda to ini onaj koji je trenutno vei. Ovako dobijeni irinski
modulisani impulsi (PWM) pojaavaju se preko pu-pul invertora i preko njegovog
transformatora raspodeljuju bazama izlaznih prekidakih tranzistora u mostu. Izlazni
napon invertora se transformie na eljeni nivo, galvanski odvaja i ispravlja diodama
D9 i D10 i na kraju filtrira prigunicom L i kondenzatorom C10.
104
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
3. UPRAVLJANJE PRETVARAIMA
Da bi se prekidaki tranzistor pravilno ukljuio i iskljuio potrebno je precizno
definisanje upravljakih impulsa kako u pogledu trajanja tako i u pogledu njegove
veliine (napon struja, snaga). Upravljaka kola se zato mogu podeliti na ona koja
generiu upravljake impulse i druga koja ove impulse pojaavaju uobliavaju i
upravljaju tranzistorima. U zavisnosti od vrste tranzistora razlikuju se i upravljaki
naponi i satuje.
3.1. UPRAVLJANJE BIPOLARNIM TRANZISTORIMA
Za pobudu bipolarnih tranzistora potrebna je odgovarajua bazna struja. Optimalno
upravljanje zahteva usklaenost ove struje sa kolektorskom. Oblik bazne struje pri
ukljuenju i iskljuenju tranzistora prikazano je na sl. 4-1. U zavisnosti od veliine
tranzistora, bazna struja moe biti i do 2 A. Jedno kolo koje obezbeuje ovakav oblik
bazne struje prikazano je na sl. 4-2. (Baker clamp). Za dobijanje negativne bazne
struje pri iskljuenju potreban je negativan polaritet ulaznog napona. Kolo na sl. 4-3,
obezbeuje negativnu baznu stuju i be promene polariteta ulaznog napona.
105
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
106
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
sl. 4-5.
107
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
108
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
109
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
Drajversko kolo IR2110 nema mogunost ogranienja struje. Kolom IR2121 istog
proizvoaa (sl. 4-9.) otklonjen je ovaj nedostatak. IR2121 je drajver samo za jedan
tranzistor. Noica broj 6 (CS current sense) meri napon prema VS (noica 5) i kada
ovaj napon pree nivo od oko 230 mV, iskljuuje tranzistor.
Ostale statike i dinamike karakteristike sline u kolu ID2110. Izvod CS postoji i
kod drajvera IR2127 (sl.4-10.) i IR2125 (sl.4-11.).
Kod kola na sl. 4-10. prati se pad napona na otpornosti RDS,ON izlaznog MOSFET-a
preko razdelnika koji ine otpornici R2 i R3.
Na sl. 4-11. je prikazano praenje struja preko otpornika u kolu sorsa (RS1 i RS2).
110
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
111
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
112
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
113
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
114
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
115
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
besprekidno napajanje. Njegova elektrina ema je prikazana na sl. 4-16. Ureaj radi
na sledei nain.
Dok postoji mreni napon RE1 je ukljuen i ovaj napon se vodi na izlaz. Za to
vreme diode unutar tranzistora T1 i T2 ispravljaju sekundarni napon transformatora i
akumulatorska baterija se puni. Pri punjenju, napon baterije prati operacioni
pojaava IC2. Trimer RV2 treba podesiti da se rele RE2 iskljui pri naponu od 14,4 V
(2,4 V/eliji). Tada prestaje punjenje i baterija je zatiena od prepunjavanja
(sulfatizacije). Prisustvo ulaznog napona signalizira tinjalica S1, a izlaznog S2.
Pri nestanku mrenog napona, rele RE1 se iskljuuje, a preko mirnog kontakta 8-11
operacioni pojaava IC1 i kolo IC3 dobijaju napon i invertor se startuje. Startovanje
je nezavisno od poloaja preklopnika START/STOP. Beznaponska pauza u izlaznom
naponu je oko 20 do 40 ms. Kao znak napajanja iz akumulatora svetli LE dioda
(uta). Operacioni pojaava IC1 (komparator) prati napon baterije pri pranjenu i
svojim izlaznim naponom napaja IC3. Potenciometar RV1 treba podesiti tako da se
invertor iskljui pri naponu od 10,8 V (1,8 V/eliji). Komparator IC1 se moe
resetovati i preklopnikom START/STOP i time iskljuiti invertorski rad. Ovim je
sl. 4-16.
116
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
117
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
sl. 4-17.
118
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
119
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
120
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
121
Radojle Radeti, Prekidaka napajanja, 4. Upravljanje pretvaraima
122
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
4. DODATAK
4.1. PRORAUN FERITNIH TRANSFORMATORA
Proraunom transformatora treba da se doe do elemenata za njegovu izradu ili
izbor. Kao polazni podaci, obino su poznati ulazni i izlazni naponi, izlazna snaga ili
struja (jednog ili vie sekundarnih namota). Dalje je poznata vrsta pretvaraa za koji
e biti primenjen. Pored ovoga na pojedine detalje mogu da utiu i trenutno
raspoloivi materijali i delovi (jezgra, ica za
namote, izolacija itd.).
Osnovni elementi za izbor ili izradu
transformatora su veliina i tip jezgra, brojevi
navojaka pojedinih namotaja i preseci njihovih
provodnika, smerovi motanja itd. Kada se odrede
ovi elementi a pre same izrade, reba proveriti
smetaj namota (moda sve ne moe da stane u
raspoloivi prostor).
Na sl. 5-2, prikazani su oblici nekih najee
sl. 5-1 korienih jezgara.
sl. 5-2.
U daljem tekstu bie rikazan pojednostavljen proraun feritnih transformatora za
primenu kod pretvaraa. Proraun e biti prikazan na primeru dvonamotnog
transformatora ali e na kraju biti pokazano kako se on primenjuje kod ostalih vrsta
pretvaraa.
Posmatrajmo dvonamotni transformator sa povrinom jezgra SFe i prozora SPR, (sl.
5-1). Njegova snaga se moe izraziri kao proizvod sekundarnih veliina struje i
napona. Osim kod najmanjih transformatora, za praksu je sasvim dobra aproksimacija
ako se uzme da isto vai i za primar tako da u daljoj analizi to nee naglaavati.
123
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
P =U I
Indukovani napon je:
U = 4 ko f N Bm S Fe
Struja se moe izraziti preko gustine struje J i preseka provodnika SCu kao:
I = J SCu
Sada je snaga transformatora:
P = 4 ko f N Bm S Fe J SCu
Uvedimo:
N SCu = k1 kCu S PR i S Fe = k Fe S Fe
Sada je snaga transformatora:
P = 4 k1 k 0 kCu k Fe f Bm J S Fe S PR
Odnosno:
P = 4 k f Bm J S Fe S PR
Znaenje pojedinih faktora je sledee:
P - prividna snaga transformatora (VA)
k0 - koeficijent oblika napona
k0=1,11 - za sinusni oblik
k0=1 - za pravougaoni oblik napona sa ispunom a=0,5
1
k0 = - za pravougaoni oblik napona sa ispunom a<0,5
2a
k1 - udeo u povrini prozora, namota koji prenosi celu snagu
kCu - koeficijent ispune povrine prozora bakrom kCu=0,25..0,5
kFe - koeficijent ispune povrine preseka jezgra gvoem (za feritna jezgra kFe=1)
k - rezultantni koeficijent (k=k0k1kCukFe)
f - frekvenca (Hz)
Bm - amplituda promene indukcije (T)
J - gustina struje u namotu (A/m2)
SFe - geometrijska povrina preseka jezgra (m2)
SPR - geometrijska povrina prozora (m2)
Ovaj izraz je sasvim opti i u obzir uzima, bilo direktno, bilo indirektno, razliite
faktore. Prema ovom izrazu snaga transformatora srazmerna je etvrtom stepenu
linearnih dimenzija.
Nedostatak dobijenog izraza za snagu transformatora je u tome to direktno ne
sadri temperaturu namota, koja je u stvari limitirajui faktor snage. Ipak indirektno,
temperatura je prisutna kroz J i Bm.
Pri konstrukciji transformatora ove dve veliine se biraju tako da temperatura
124
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
J ( A / mm 2 ) = 0,45[S Fe ( m 2 ) S PR ( m 2 )]
1 / 8
J ( A / m 2 ) = 4,5 105 [S Fe ( m 2 ) S PR ( m 2 )]
1 / 8
P = 0,18 k f Bm [S Fe ( cm 2 ) S PR ( cm 2 )]
7/8
125
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
8/7
11 10 7 P
S Fe ( m ) S PR ( m ) =
2 2
k f Bm
ili
8/7
11 P
S Fe ( cm ) S PR ( cm ) =
2 2
k f Bm
Pri simetrinom magneenju jezgra ova
promena indukcije jednaka je B=2BM, to
kod feritnih jezgara iznosi priblino 0,5T.
Na primer za dvonamotni transformator, pri
k0,2, BM=0,25T (B=2BM=0,5T), dobija
se:
sl. 5-3. 1,143
P
S Fe ( cm ) S PR ( cm ) = 215
2 2
f
Iz ovako izraunatog proizvoda (SFeSPR)
iz kataloga se bira prvo vee jezgro. Prema
izabranom jezgru, izraunavaju se brojevi
navojaka pojedinih namotaja.
Broj navojaka primara odreuje se prema
ulaznom naponu i iznosi:
U I tON ,MAX U I a MAX
N P ,MIN = = 104
B S FE B S FE ( cm ) f
2
126
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Pg
( 0 C ) = 840
S ( cm 2 )
Pri proraunu transformatora za druge vrste pretvaraa moraju se uzeti u obzir
njihove specifinosti. One se u prvom redu ogledaju u nainu magnetisanja jezgra
(B), broju namotaja i obliku struje u njima (obuhvaeno kroz k i J).
Transformatori mostnog i polumostnog pretvaraa razvijaju najveu snagu. U
tabeli 5-1. su prikazani odnosi snaga transformatora za pojedine vrste pretvaraa, u
odnosu na mostni. U njoj su prikazane i vrednosti koeficijenta k1 za ove tipove
transformatora. Tabela ukazuje na mogunost iskoriavanja pojedinih vrsta
transformatora u pogledu snage. Zbog malog iskorienja gabarita forvard, fly-back
praktino dolaze u obzir samo na frekvencijama reda desetine kHz i jezgrima od
ferita.
Pu-pul, polumost i most dolaze u obzir na svim frekvencama, s tim to mostni
omoguava i najbolje iskorienje prekidakih elemenata (tranzistora) pa se sa njim
mogu postii najvee snage.
Na sl. 5-3 prikazane su tipine krive magneenja feritnih jezgara za nekoliko
temperatura, a na sl. 5-4 gubici u njima u zavisnosti od frekvencije i indukcije.
Za detaljnije informacije o konkretnim jezgrima treba konsultovati kataloki
materijali, aplikacione note, prirunike, uputstva i drige publikacije proizvoaa.
Poznati proizvoa feritnih jezgara Siemens Matsushita Components (S+M) nudi
za pretvarae jezgra prikazana u tabeli tabeli 5-2. U tabeli 5-3 prikazane su neke
karakteristike ovih materijala.
Pretvara k1 k P/Pmost
1. Mostni 0,50 0,20 1
2. Polumostni 0,50 0,20 1
Push-pull/standardni 0,41 0,17 0,83
3.
Push-pull/push-pull 0,50 0,20 0,71
Forvard dvotranzistorski 0,50 0,20 0,35
4. Forvard jednotranzistorski, sa vraanjem energije 0,45 0,18 0,32
Forvard sa R-C-D kolom 0,50 0,20 0,35
Fly-back dvotranzistorski, sa vraanjem energije 0,41 0,17 0,25
Fly-back jednotranzistorski, sa vraanjem energije 0,33 0,13 0,20
5.
Fly-back diskontinualni, bez vraanja energije 0,50 0,20 0,31
Fly-back kontinualni, bez vraanja energije 0,50 0,20 <0,3
Tab. 5-1.
127
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
128
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
129
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
130
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
4.2. PRIGUNICE
Prigunice su induktivni elementi koji akumuliraju energiju u obliku magnetnog
polja. Prigunice mogu biti sa ili bez jezgra. Pri istoj induktivnosti i struji, prigunice
sa jezgom su manjih gabarita.
Kod pretvaraa, prigunice se najee primenjuju u filterskim kolima. To moe da
bude u jednosmernim kolima gde treba potisnuti naizmeninu komponentu, ili u
naizmeninim kolima. Kod prigunica za jednosmerna kola, glavna struja je
jednosmerna, a naizmenina komponenta je manjeg intenziteta. Zbog toga se u
jednosmernim i kolima mrene frekvence mogu koristiti prigunice sa jezgrom od
trafo lima. U kolima sa viom frekvencom, jezgo je feritno.
Osnovni parametri prigunice su induktivnost i omska otpornost, a za vie
frekvence vana je i parazitna kapacitivnost. Omski otpor pri jednosmernoj struji se
izraunava na osnovu specifine otpornosti, preseka i duine provodnika. Kod
naizmenine struje, zbog skin efekta, omski otpor se poveava. Zbog toga se namoti
za vie frekvence motaju provodnicima u obliku snopa sastavljenog od tankih
izolovanih ica.
Induktivnost je vaan parametar namotaja i definie se kao odnos obuhvaenog
magnetnog fluksa (), i struje u njemu. Poto svaki navojak obuhvata isti fluks,
ukupan fluksni obuhvat je N puta vei od stvarnog fluksa (). Sa ovim induktivnost
posmatranog namotaja sa N zavojaka je:
N
L= =
I I
Induktivnost moe da akumulira i energiju u obliku magnetnog polja. Pri
magnetnom fluksu () i strtuji (I), akumulisana energija u induktivnosti je:
I L I 2 B S Fe I
EM = = =
2 2 2
Induktivnost kalema zavisi od njegove geometrije i mogu se uspostaviti pribline
matematike relacije za razliite oblike.
Induktivnost prigunice bez jezgra zavisi od broja navojaka i geometrije jezgra. Ne
postoji opti izraz za njeno izraunavanje pa se u zavisnosti od konkretnog oblika
koriste razliite formule.
Za okrugli cilindrini namot sa brojem navojaka N, odnosom prenika (d) i visine
(h) u opsegu 0,5 do 2, se moe koristiti sledei izraz:
0 , 67
7 d d
L = 6,8 10 N d
2
, za 0,5 < <2
h h
Za primenu kod pretvaraa koriste se prigunice sa jezgrom. Samo jezgro ima
veliku permeabilnost, tako da maksimalnu indukciju postie pri vrlo maloj struji.
Zbog toga je mogunost akumulacije energije veoma mala. Ovde se onda radi o
velikoj induktivnosti ali za veoma malu struju. Da bi se poveala struja, u jezgro se
131
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
uvodi zazor (). Sada se jezgro ponaa kao nehomogeni provodnok magnetnog polja.
U optem sluaju nehomogenog jezgra induktivnost je:
0 0 S Fe
L = N2 N2
l l
R S Fe R
132
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
L
'
S Fe = Im
Bm J kCu k j
Na osnovu ove vrednosti bira se standardno jezgro iji je stvarni presek SFe. Prema
ovako odabranom jezgru izraunava broj navojaka i zazor.
N Im L Im
' = 0 i N'=
Bm Bm S Fe k Fe
Ovo su raunske vrednosti i na osnovu njih se biraju:
N Pogodan broj navojaka
Pogodan vazduni zazor
Ponekad se ukupan zazor sastoji iz dva dela (na primer razmaknuta EE jezgra), pa
je onda ovako izraunat zazor ukupan.
Presek provodnika se odreuje iz relacije:
Im
SCu =
J
Zavisnost gustine struje od dimenzija jezgra odreena je u delu o proraunu
feritnih transformatora.
Za feritna jezgra proizvoai daju takozvani faktor induktivnosti (AL). To je
induktivnost posmatranog jezgra pri jedininom broju navojaka (N=1).
Faktor induktivnosti definisan je na sledei nain:
L 0 0 S Fe
AL = =
N2 l l
R S Fe R
133
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
134
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
U CR = U IN [1 cos R (t t1 )] , I CR = U IN
CR
sin R (t t1 )
LR
Amplituda napona rezonantnog kondenzatora dvostruko je vea od ulaznog (2UIN).
1
Rezonantna frekvencija je priblino: R
2 LR C R
Struja rezonantne prigunice (i prekidaa) je:
CR
iLR = iSW = I O + U IN sin R (t t1 )
LR
Prekidaki tranzistor se bira prema amplitudi ove struje i ona je:
CR
iSW ,MAX = I O + U IN
LR
Od t2 i napon kondenzatora i struja prigunice opadaju. Kada struja rezonantne
prigunice padne na nulu (trenutak t3) prekida ve moe da se iskljui. Napon
kondenzatora u trenutku t3 je:
I
2
U C ,t3 = U IN 1 + 1 O
I C ,MAX
Zbog diode na red sa prekidaem, struja ne moe da promeni smer i do trenutka t5
ostaje na nuli. Ovo je interval vremena u kome se prekida iskljuuje pri nultoj struji
(ZCT). Trajanje intervala vremena od t3 do t5 je:
2
1 1
2
2C U IN
t5 t3 = 2C U IN =
I C2 ,MAX I O2
I O I C ,MAX I O I C ,MAX
Trajanje ovog intervala zavisi od struje optereenja. Pri malim strujama
optereenja kondenzator ne stie da se isprazni, tako da je potrebno produavanje
vremena tOFF (interval od t3 do t6) i omogueno krae tON.
135
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
U praznom hodu (IO=0), trajanje tON moe biti minimalno i jednako je polovini
periode rezonantne oscilacije. Da bi se prelazak vrio pri nultoj struji potrebno je da
se iskljuenje izvri u toku druge poluperiode. Trajanje tOFF bi trebalo da bude veoma
dugo, jer bi se u protivnom izlazni kondenzator permanentno dopunjavao a njegov
napon stalno rastao.
Sa poveanjem struje optereenja interval vremena u kome se iskljuenje
prekidaa vri pri nultoj struji se skrauje. Da bi
bilo mogue iskljuenje pri nultoj struji potrebno
je da amplituda struje rezonantnog kondenzatora
bude vea od struje optereenja (IC,MAX>IO). Pri
veim strujama optereenja ne moe se postii
iskljuenje prekidaa pri nultoj struji.
U intervalu vremena od t4 do t5 kondenzator se
prazni izlaznom strujom, tako da njegov napon
opada linearno do nulte vrednosti (trenutak t5).
U intervalu od t3 do t6 kondenzator se prazni
konstantnom strujom tako da njegov napon opada
linearno:
I O ( t t3 )
U C = U Ct3
CR
Posle trenutka t6 kondenzator je ispranjen i ako
se prekida ukljui ciklus se ponavlja na isti nain.
Rezonantni rad se moe postii kod svih vrsta
prekidaa. Na sl. 5-8. prikazane su rezonantne
konfiguracije kod jednoimpulsnih pretvaraa.
Rezonantni elememtni vezani su redno a uzimanje
snage iz rezonantnog kola vri se paralelnom
vezom optereenja i kondenzatora.
Kod pretvaraa sa transformatorom rezonantni
sl. 5-8. elementi (LR i CR) mogu biti smeteni u primaru,
sekundaru ili na obe strane.
0.0.0. REZONANTNI RAD KOD INVERTORA
Kod invertora, primarna struja transformatora je naizmenina. Rezonantno kolo
moe biti smeteno izmeu pretvaraa i transformatora. U rezonantnom kolu se moe
akumulisati velika energija. Njeno odvoenje priguuje oscilacije i ograniava struje i
napone u njemu. Iznoenje energije iz ovog kola prema optereenju moe biti tako
to se ono vee u kolo na red, paralelno sa LR ili CR ili nekom drugom kombinacijom.
136
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
sl. 5-9.
sl. 5-11.
137
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Na sl. 5-9 prikazan je invertor i redno rezonantno kolo. Sam invertor je generator
pravougaonog naizmeninog napona. Ostali deo kola se moe pretstaviti kao
ekvivalentna otpornost redno vezana u rezonanrtnom kolu. Za redno kolo oblici struje
i napona kondenzatora, za razliite sluajeve, prikazani su na sl. 5-10. U matematiku
analizu ovih oblika se nee ulaziti.
Kod ovog kola struja jako zavisi od frekvencije. Na rezonantnoj frekvenciji L-C
kolo pretstavlja kratak spoj za osnovni harmonik. Struja je ograniena samo aktivnom
otpornou (RO) preslikanom na primarnu stranu transformatora. Pri kratkom spoju
na izlazu struja postaje jako velika. Struju prate i naponi na LR i CR, tako da moe
doi do njihovog oteenja.
Ako je optereenje vezano paralelno rezonantnom kondenzatoru (sl. 5-11.)
ponaanje invertora je drugaije. U odnosu na redno kolo sa sl. 5-10, ovde je
otpornost optereenja znatno vea. U suprotnom rezonantno kolo je jako prigueno.
Na rezonantnoj frekvenciji izlaz ne sme ostati nepotereen jer dolazi do pojave
velikih struja u kolu i napona na LR i CR. Ova situacija jednaka je kratkom spoju kod
rednog rezonantnog kola. Za paralelno kolo oblik struje i napona kondenzatora, za
razliite sluajeve, prikazani
su na sl. 5-12.
Pored ove dve osnovne
konfiguracije istrauju se i
razne kombinacije ovih
elemenata. Jedna takva veza
prikazana je na sl. 5-13. Ona
je navedena samo ilustracije
radi i nee se ulaziti u njenu
sl. 5-13. dalju analizu.
138
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
sl. 5-14.
139
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Tab. 5-5. Najvanije karakteristike nekih esto korienih tranzistora tipa MOSFET
140
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
141
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
142
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
143
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
144
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
145
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
146
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
147
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
148
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Polumostni pretvara za napajanje fluo cevi snage 55 W sa kolom sa PFC (lit. 15)
149
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
150
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
151
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
152
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Slobodan uk
Nesumnjivo jedan od najveih autoriteta u oblasti
energetske elektronike Srpskog porekla, je profesor Slobodan
uk. Dr uk je profesor na poznatom amerikom Caltek
univerzitetu i nosilac je vise vrednih amerikih i
medjunarodnih priznanja za pronalazastvo, kao i oredena
Nikole Tesle dobijenog od strane Republike Srbije. Pretvarai
u svetu poznati pod njegovim imenom, primenjuju se i na
satelitima a napajaju i neke od najbrih raunara na svetu.
Autor je velikog broja radova iz oblasti energetske elektronike.
Sa R.D. Mildebrook-om autor je knjiga Advances in Switched-mode Power
Conversion (Volume I, II i III). Slobodan uk je osniva i vlasnik kompanije
TESLAco, specijalizovanom za konstrukciju prekidakih napajanja visokih
performansi za komercijalne i vojne primene. (http://www.teslaco.com/teslaco.html)
Vojislav Stefanovi
Vojislav Stefanovi je roen 1940 u Beogradu. Diplomirao
je 1964 na Elektrotehnikom Fakultetu u Beogradu, a
magistrirao i doktorirao 1969 i 1975 na McGill Univerzitetu u
Montrealu, Kanada. Radio je kao profesor u Montrealu do
1979, a zatim kao redovni profesor na University of Misouri,
SAD. 1981. je preao, u GE i bavio se servo pogonima i
robotikom. Godine 1985 prelazi u Electro-Craft, u
Minneapolis-u, kao generalni direktor dela za servo sisteme, a
1986. u Emerson Electric, kao tehniki direktor odeljenja za
elektro-motorne pogone. Od 1989 radi kao tehiki direktor u SIEI Peterlongo, u
severnoj Italiji. Od 1991. je direktor dve Italijanske fabrike Amerikog preduzea
Vickers. Krajem 1993 se vraa za Ameriku, gde i dalje radi kao konsultant u oblasti
elektro-motornih pogona i energetske elektronike. Vojislav Stefanovi je publikovao
veliki broj radova i dao je znaajan doprinos energetskoj elektronici u ranijoj fazi
njenog razvoja (1975-1985).
153
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Aleksandar Stankovi
Roen 1960. godine u Velikom Bekereku. Diplomirao
1983. godine. Radio je u Institutu Mihailo Pupin i na
Elektrotehnikom Fakultetu u Beogradu do 1987. godine. Od
1988. do 1992. godine radi na univerzitetu u Kembidu. Danas
je profesor na Northeastern University, Boston, USA. Bavi se
energetskom elektronikom, teorijom upravljanja,
elektromotornim pogonima itd. (http://www.ece.neu.edu/)
Ana Stankovi
Ana Stankovi je studirala na Elektrotehnikom Fakultetu u
Beogradu, gde je diplomirala 1982. a magistrilara 1989. godine.
U periodu od 1983. do 1990. godine radila u Institutu Nikola
Tesla u Beogradu. Doktorsku disertaciju odbranila je 1998.
godine na University of Wisconsin-Madison. Danas radi kao
profesor na Cleveland State University, Department of
Electrical Engineering. Bavi se pitanjima iz oblasti elektrinih
maina i energetske elektronike. Autor je knjiga: The Power
Electronics Handbook i Hndbook of Automotive Power Electronics and Motor
Drives. (http://academic.csuohio.edu/stankovica/)
Dragan Maksimovi
Dragan Maksimovi je roen 1961. godine u Beogradu.
Diplomirao 1984. i magistrirao 1986. godine na ETF u
Beogradu. Doktorirao na California Institute of Technology,
Pasadena 1989. godine. Dragan Maksimovi je danas profesor
na Electrical and Computer Engineering Department of the
University of Colorado. Bavi se malim sistemima sa
baterijskim napajanjem, ispravljaima sa malim harmonicima,
analizom i simulacijama visokofrekventnih prekidakih pretvaraa snage itd.
(http://ece-www.colorado.edu/~maksimov/)
Armen Baronijan
Armen Baronijan je rodjen u Beogradu 1962. godine.
Diplomirao je na Elektrotehnickom Fakultetu u Beogradu 1988.
godine. U periodu od 1989. do 1992. godine je radio u Institutu
Nikola Tesla u Beogradu. Magistrirao je 1994. a doktorirao
1997. godine na Univerzitetu u Torontu, u Kanadi. Danas radi
na Univerzitetu u Torontu u Centru za primenjenu Energetsku
Elektroniku kao vodeci istrazivac. Bavi se razvojem pretvaraca
srednje i velike snage koji se upotrebljavaju u laboratorijama za
ubrzavanje cestica, nuklearnim elektranama i vetrenjacama.
(http://www.ele.utoronto.ca/~cape/)
154
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Duan Borojevi
Roen je 1952. u Zagrebu. Diplomirao je 1976. na
Elektrotehnikom fakultetu u Beogradu, magistrirao 1982. na
Fakultetu tehnikih nauka u Novom Sadu i doktorirao 1986. na
Virdinijskom dravnom univerzitetu i politehnikom institutu
(Virginia Tech) u SAD. Od 1976. do 1982. godine radio je kao
asistent na Instituitu za Energetiku i Elektroniku FTN
Univerziteta u Novom Sadu, a od 1986. do 1990. kao docent.
Od 1990. godine je profesor na Virginia Tech i kodirektor
Centra za sisteme energetske elektronike (CPES), jedne od
najveih istraivakih grupa za energetsku elektroniku. Najvie
se bavio modelovanjem, analizom i upravljanjem viefaznih i vienivovskih,
visokofrekventno-prekidakih, energetskih pretvaraa i pretvarakih sistema za
srednje i vee snage. (http://www.ece.vt.edu/faculty/boroyevich.html)
Milan M. Jovanovi
Milan M. Jovanovi, rodjen u Beogradu, diplomirao na
elektrotehnikom Fakultetu u Beogradu, magistrirao na
Fakultetu Tehnikih Nauka u Novom Sadu i doktorirao na
Virdjinijskom Dravnom Univerzitetu i Politehnikom Institutu
(Virginia Tech). Od 1976. do 1983. godine radio je na Instituitu
za Energetiku i Elektroniku Fakulteta Tehnikih Nauka u
Novom Sadu, U periodu od 1983. do 1991. godine bio je
istraziva u Centru za Energetsku Elektroniku pri Virginia
Tech. Od 1991. godine zaposlen je u Delti (Delta Electroinics,
Inc.), jednoj od najveih kompanija za razvoj i proizvodnju
izvora za napajanje za komjutersku i telekomunikacionu
opremu, gde je trenutno zaduen za razvoj i istraivanje sledee generacije izvora za
napajanje. Autor je velikog broja radova iz oblasti savremenih prekidaih izvora
napajanja. Jedan broj ovih radova je dostupan na sajtu http://www.deltartp.com.
Laslo Huber
Laslo Huber je roen u Novom Sadu 1953. godine.
Diplomirao je na FTN Univerzitetu u Novom Sadu 1977. i
radio kao asistent do 1992. godine. Magistrirao je na
Univerzitetu u Niu 1983. godine, a doktorirao na Fakultetu
Tehnikih Nauka u Novom Sadu, 1992 godine. Od 1992. do
1994. godine radio je kao istraiva u Centru za Energetsku
Elektroniku pri Virginia Tech, Blacksburg, Virginia. Od 1994.
godine radi kao istraiva u kompaniji Delta Products
Corporation, Research Triangle Park, North Carolina. U svom
dugogodinjem radu bavio se analizom, modelovanjem, simulacijom i konstrukcijom
savremenih tranzistorskih pretvaraa snage. (http://www.deltartp.com/dpel/dpel.asp)
155
Radojle Radeti, Prekidaka napajanja, 5. Dodatak
Emil Levi
Roen je 1958. godine u Zrenjaninu, Jugoslavija. Diplomirao
je na FTN Univerziteta u Novom Sadu 1982. Magistrirao 1986.
i doktorirao 1990. na ETF Univerziteta u Beogradu. Od 1982.
do 1991 godine radio je na FTN Univerzitetu u Novom Sadu
kao asistent i docent. Od 1992 godine je na Liverpool John
Moores University, gde danas radi kao profesor u oblasti
Elektrinih maina i Elektromotornih pogona. Oblasti njegovog
istraivakog rada su modelovanje i simulacija elektrinih
maina, upravljanje pogonima i pretvaraima energetske elektronike. Objavio je
preko 200 radova, od toga preko 50 u vodeim meunarodnim asopisima.
(http://www.eng.livjm.ac.uk/research/groups/emad/home.html)
Silva Hiti
Roena je 1963. u Novom Sadu. Diplomirala je 1987. na
FTN Univerziteta u Novom Sadu, magistrirala 1990. na
Fakultetu tehnikih nauka u Mariboru i doktorirala 1996. na
Virdinijskom dravnom univerzitetu i politehnikom institutu
(Virginia Tech) u SAD. Od 1995. radi u Centralnom Razvoju
najvee amerike automobilske kompanije, General Motors, na
razvoju elektrinih pogona i energetskih pretvaraa za primene
u elektrinim i hibridnim automobilima. Publikovala je radove
iz oblasti kontrole energetskih pretvaraa i elekrinih masina. Pronalaza je na
mnogim General Motors patentima iz ovih oblasti.
P.S.
Autor je uloio dosta truda da pronae potrebne podatake o ovim linostima.
Sigurno da ima jo imena koja bi trebalo da se nau na ovom mestu. Ogranieno
vreme, raspoloivi podaci i realni uslovi, nisu dozvolili da se uradi vie.
Svakako da postoje i ljudi koji ive i rade u Srbiji, a dali su svoj doprinos
energetskoj elektronici. To su profesori i asistenti na fakultetima, koji se pored
istraivakog rada bave i obrazovanjem kadrova iz ove oblasti. Vaan doprinos daju i
istraivai u institutima i inenjeri u firmama koji se bave konstrukcojom i
proizvodnjom ovih ureaja. Okviri ove knjige su mali da bi svi oni bili obuhvaeni.
Svima koji su izostavljeni ili nisu u dovoljnoj meri pomenuti, autor ove knjige
upuuje duboko izvinjenje.
156
Radojle Radeti, Prekidaka napajanja, Literatura
LITERATURA
Knjige:
1. T. Brodi: Energetska elektronika; Svjetlost, Sarajevo 1986.
2. S. uk: Advances in switchsd-mode power conversion, volume I & II,
TESLAco, Pasadena, California 1983.
3. S. uk: Advances in switchsd-mode power conversion, volume III, TESLAco,
Pasadena, California 1983.
4. B. Doki: Impulsni DC/DC pretvarai; Elektrotehniki fakultet - Nauka, Banja
Luka - Beograd, 1995.
5. R. Radeti: Tranzistorski pretvarai snage; II Izdanje, Nauka Beograd 2002.
6. R. Radeti: Tiristorski pretvarai; Nauka Beograd 2004
7. D. Rajakovi, . Janda: Sistemi za besprekidno napajanje elektrinom
energijom, Agencija Spiridonovi, Beograd, 1999.
8. B. D. Bedford: Principles of inverter circuits; John Wiley and sons, inc. 1964.
9. B. K. Bose: Power electronics and drives; Prentice-Hall, 1986.
10. F. Csaki: Power electronics; Budapest 1975.
11. S. B. Dewan: Power semiconductor drives; John Wiley and sons, inc. 1984.
12. S. B. Dewan: Power semiconductor circuits; John Wiley and sons, inc. 1975.
13. F. Mazda: Thyristor Control; John Wily and Sons 1973.
14. K. Thorborg: Power electronics, 1988 Prentice Hall International (UK) Ltd.
Internet:
15. Switchmode Power Supplies, Reference Manual and Design Guide, ON
Semiconductor, Rev. 3, July2002, Website: http://onsemi.com
16. Fairchild Semiconductor Corporation, HVIC/IGBT Half-Bridge
ConverterEvaluation Circuit, AN-7508.
17. Design Review: Bill Andreycak, 500 W, 40W/in3 Phase Shifted ZVT Converter,
Texas Instruments Inc, 2001.
18. Dennis L Feutcht, Halh bridge circuit behavior
19. Jaber A. Abu-Qahouq, HongMao, and Issa Batarseh, Alternated duty cycle
control method for half-bridge DC-DC converter, 2005 Holon Academic
Institute of Technology.
20. H. Visairo, E. Rodrguez, P. Alou (3) and J. A. Cobos, Multi-Output Half-
Bridge Converter with Single-Winding Self-Driven Synchronous Rectification,
2003 IEEE.
21. By Ernest H. Wittenbreder Jr., Power Converter Synthesis, Part 3: Near Zero
Emissions, www.powerelectronics.com
22. Steve Mappus, Control Driven Synchronous Rectifiers In Phase Shifted Full
Bridge Converters, Texas Instruments, SLUA287 March 2003.
23. Kaiwei Yao, Yu Meng and Fred C. Lee, A Novel Winding Coupled-Buck
Converter for High-Frequency, High Step-Down DC/DC Conversion.
157
Radojle Radeti, Prekidaka napajanja, Literatura
24. Yuri Panov and Milan M. Jovanovic, Design Considerations for 12-V/1.5-V, 50-
A Voltage Regulator Modules. 2000 IEEE
0. National Semiconductor, Application Note 1197, Sanjaya Maniktala, July 2002,
Selecting Inductors for Buck Converters.
0. TOPSwitch Flyback Power Supply Efficiency, Application Note AN-19, Power
Integrations Inc. June 1996.
0. Dhaval Dalal, A Unique Four Quadrant Flyback Converter, Texas Instruments
Incorporated, 2001.
0. AN9011, High Input Voltage, Off-line Flyback Switching Power Supply using
FSC IGBT (SGL5N150UF) By JunBae Lee, July, 2000
0. Brian T. Irving and Milan M. Jovanovi, Analysis and Design of Self-
Oscillating Flyback Converter, 2002 IEEE
0. Application Note AN4140, Transformer Design Consideration for off-line
Flyback Converters using Fairchild Power Switch, www.fairchildsemi.com
0. Lioyd H. Dixon, Jr, Design Flyback transformers and Filter Inductors, 2001,
Texas Instruments Incorporated.
0. TOPSwitch Flyback Transformer Construction Guide, Application Note AN-18.
Power Integrations Inc. Juny 1996.
0. Very Wide Input Voltage Range, Off-Line Flyback Switching Power Supply,
Prepared by: Marty Brown, November, 2002 - Rev. 1, AN1327/D,
http://onsemi.com
0. Wim Bosboom, Kees Schetters, Application Note, AN10268_1, A 75W Quasi
Resonant TEA1506 based flyback Converter for TV Applications,
0. Wim Bosboom, Kees Schetters, Wim Bosboom, Kees Schetters.
0. A180W, 100KHz Forward Converter Using QFET, Application Note 9015 by
I.S. Yang, July, 2000, Fairchild Semiconductor International, Rev. B, July 2000.
0. Raoji Patel, 250 W Off-Line Forward Converter design review. Unitrode
Corporation.
0. 300W Secondary Controlled Two-Switch, Forward Converter With L5991A,
AN 621 Application Note. 2004 STMicroelectronics.
0. Active Clamp and Reset Technique nhances Forward Converter Performance,
Bill Andreycak, 2001, Texas Instruments Incorporated.
0. Qiong Li, Fred C. Lee and Milan M. Jovanovi, Design Considerations of
Transformer DC Bias of Forward Converter with ctive-Clamp Reset, 1999 IEEE
0. Application Note AN4134, Design Guidelines for Off-line Forward Converters
Using Fairchild Power Switch, Fairchild Semiconductor Corporation
www.fairchildsemi.com
0. Marty Brown, AND8039/D, The One-Transistor Forward Converter,
Semiconductor Components Industries, LLC, 2000, http://onsemi.com,
0. Laszlo Huber, Milan M. Jovanovi, Forward-Flyback Converter with Current-
Doubler Rectifier: Analysis, Design, and Evaluation Results, 1999 IEEE.
0. Designing a 2 Transistor Forward Converter Using a CoreMaster E2000Q Core,
Colonel Wm. T. McLyman, AN107, www.coremaster.com
158
Radojle Radeti, Prekidaka napajanja, Literatura
159