SPECIFICATIONS SHEET

BYTEGRID
TRANSPARENT STAR

AURORA, IL
R

WHITE

BYTEGRID
R

CHI1 is a purpose built, ultra secure, multi-tenant data center, that is concurrently
maintainable. Flexible space and power infrastructure solutions can be configured to
meet a wide variety of tenant space, power and redundancy requirements.
7693 C 376 C
100.75.31.14 50.0.100.0
8.73.117 141.198.63
#084975 #8DC63F

PROPERTY DATACENTER AREA DESCRIPTION


Location: Aurora, IL Slab to Slab: 24 ft

County: Dupage County County Number of Computer Rooms: One (1)

Land Parcel: 5.25 acres Raised Floor Area: 33,513 ft2

Building Size: 70,000 ft2 Raised Floor Height: 36 in.

Transportation: 38 miles from MDW airport, Raised Floor to Ceiling Height: 11 ft


32 miles from OHare International
Walk to Metra Station, Easy Access to I88
NETWORK

BUILDING DESCRIPTION Network Carriers:

Building Name: CHI1 AT&T, Comcast, Sprint, Verizon, Level3, Telx, OnLight
Aurora, Wide Open West (WOW), NTT, Direct Connect to
Utility Power Feeds: Capacity 4.5mW 350 E Cermac Rd - One of the largest carrier hotel housing
Parking: 121 spaces over 70 network carriers

Number of Stories: One (1)

Loading Docks: One (1) FIRE PROTECTION


Description: Dual Interlocking
COMPUTER ROOM SPECIFICATIONS Pre-Action System, FE-25, VESDA

Computer Room: 33,513 sq.ft.


POWER DISTRIBUTION

TECHNICAL OFFICE SPACE PDU Description: 225kVA PDU, N+1 classification

Staging: One (1) Common Burn and Test Room

Shared: 6,000 sq.ft.

Flex Work area, disaster recovery /


business continuity offices
and workstations

Two (2) conference rooms

Kitchen

Shower facilities

www.ByteGrid.com 855.495.0098
GENERATORS ON-SITE FUEL CAPACITY
Description: Three (3) 2MW generators Storage Tanks: Two (2) 15,000 gallon tanks provide
total 6MW (expandable)
72 hr run time at full load
Redundancy: N+1

HVAC SYSTEMS
UPS SYSTEMS
Description: Primary chilled water;
Description: Four (4) 750 KVA Liebert secondary DX cooling combination
UPS Systems(expandable)
Configuration: Chilled water primary
Redundancy: 2N, N+1 source, redundant
source DX cooling, 2N design

SECURITY Chillers: 500 tons expandable to 1,500 tons

Property Line Physical Setback: 70 ft from the front,


10 ft to the back REGULATORY CERTIFICATIONS & ALIGNMENTS
25 ft to the side
Description: SOC 2 Type II, PCI DSS, FISMA,
Security Guards: Staffed 24/7/365 ISO 27001, ISO 9001, EHNAC accredited,
GxP & HIPAA Qualified
Access Controls: Card key, security check-in
at reception

CRITICAL POWER
Total Megawatts: 2.7 MW expandable

Redundancy: Configured as 2N, N+1

BYTEGRID
R

www.ByteGrid.com | 1.855.495.0098