Dialux Calculation (Scheme-3 Villa)
Dialux Calculation (Scheme-3 Villa)
(SCHEME-3 VILLA)
VILLA - SCHEME 3
Date: 06 / 12 / 2014
Operator: FAEC+CBT
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
4 Pieces NARDEEN LIGHTING CO. SMP 240W SMP See our luminaire
2/40W RS HPF (Type 1) catalog for an image of
Article No.: SMP 240W the luminaire.
Luminous flux (Luminaire): 3493 lm
Luminous flux (Lamps): 5200 lm
Luminaire Wattage: 80.0 W
Luminaire classification according to CIE: 78
CIE flux code: 48 77 91 78 67
Fitting: 1 x User defined (Correction Factor
1.000).
18 Pieces NARDEEN LIGHTING CO. SMP 240W SMP See our luminaire
2/40W RS HPF catalog for an image of
Article No.: SMP 240W the luminaire.
Luminous flux (Luminaire): 3761 lm
Luminous flux (Lamps): 5600 lm
Luminaire Wattage: 80.0 W
Luminaire classification according to CIE: 78
CIE flux code: 48 77 91 78 67
Fitting: 2 x T38 40W CW 2800 LUMEN
(Correction Factor 1.000).
3 Pieces NARDEEN LIGHTING CO. SMP 240W SMP See our luminaire
2/40W RS HPF (Type 2) catalog for an image of
Article No.: SMP 240W the luminaire.
Luminous flux (Luminaire): 4433 lm
Luminous flux (Lamps): 6600 lm
Luminaire Wattage: 80.0 W
Luminaire classification according to CIE: 78
CIE flux code: 48 77 91 78 67
Fitting: 1 x User defined (Correction Factor
1.000).
2 Pieces NARDEEN LIGHTING CO. SMP 240W SMP See our luminaire
2/40W RS HPF (Type 3) catalog for an image of
Article No.: SMP 240W the luminaire.
Luminous flux (Luminaire): 3896 lm
Luminous flux (Lamps): 5800 lm
Luminaire Wattage: 80.0 W
Luminaire classification according to CIE: 78
CIE flux code: 48 77 91 78 67
Fitting: 1 x User defined (Correction Factor
1.000).
Page 2
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
12.80 ft
37.16
37.16 32.52
37.16
32.52 41.81 41.81
41.81
37.16
41.81 37.16
46.45 46.45
37.16 46.45
41.81 46.45
41.81
46.45 37.16
37.16 41.81
41.81 41.81
37.16
37.16
37.16 32.52
0.00
0.00 12.86 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:51
Workplane:
Height: 2.493 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.717, Ceiling / Working Plane: 0.669.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3493 5200 80.0
2/40W RS HPF (Type 1)* (1.000)
*Modified Technical Specifications Total: 13970 Total: 20800 320.0
Specific connected load: 1.95 W/sq ft = 0.51 W/sq ft/10 fc (Ground area: 164.15 sq ft)
Page 3
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
9.72 ft
45.52
45.52 39.02
39.02 45.52
52.02 52.02
45.52
52.02 58.53 58.53 58.53
52.02 45.52
58.53 58.53
58.53 58.53
52.02 52.02
58.53 58.53
58.53 58.53
45.52 52.02
52.02 52.02 45.52
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:39
Workplane:
Height: 2.953 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.657, Ceiling / Working Plane: 0.655.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 3 4433 6600 80.0
2/40W RS HPF (Type 1)* (1.000)
*Modified Technical Specifications Total: 13299 Total: 19800 240.0
Specific connected load: 1.91 W/sq ft = 0.40 W/sq ft/10 fc (Ground area: 125.98 sq ft)
Page 4
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
32.52 12.30 ft
32.52
27.87 27.87
37.16 37.16
37.16
32.52
37.16 32.52
41.81
41.81 41.81
41.81
37.16 37.16
37.16 37.16
32.52 32.52
0.00
0.00 17.55 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:49
Workplane:
Height: 2.625 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.684, Ceiling / Working Plane: 0.630.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.49 W/sq ft = 0.43 W/sq ft/10 fc (Ground area: 215.32 sq ft)
Page 5
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
13.78 ft
22.30 29.73 29.73
29.73
26.01 29.73 33.44
33.44
33.44
37.16 37.16
29.73 37.16 29.73
37.16 37.16
37.16 33.44
37.16
37.16 37.16
37.16 37.16
29.73
29.73
33.44
33.44 33.44
26.01
29.73 29.73
29.73
26.01
0.00
0.00 18.04 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:54
Workplane:
Height: 2.493 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.660, Ceiling / Working Plane: 0.595.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.29 W/sq ft = 0.42 W/sq ft/10 fc (Ground area: 248.65 sq ft)
Page 6
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
14.11 ft
29.73
26.01 29.73 29.73
26.01
33.44 33.44
33.44
33.44
29.73 37.16 37.16 29.73
37.16
37.16
37.16 33.44
33.44 37.16
29.73 37.16
37.16 29.73
33.44
33.44 37.16
37.16
37.16
29.73 33.44 33.44
33.44 29.73
0.00
0.00 17.88 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:56
Workplane:
Height: 2.625 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.643, Ceiling / Working Plane: 0.590.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.27 W/sq ft = 0.40 W/sq ft/10 fc (Ground area: 252.26 sq ft)
Page 7
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
10.93 ft
29.73 29.73
26.01
33.44 33.44 26.01
37.16 29.73
29.73
37.16
33.44
33.44
33.44
37.16
29.73 29.73
33.44
26.01
0.00
0.00 9.42 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:43
Workplane:
Height: 2.625 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.700, Ceiling / Working Plane: 0.732.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 2 3896 5800 80.0
2/40W RS HPF (Type 1)* (1.000)
*Modified Technical Specifications Total: 7791 Total: 11600 160.0
Specific connected load: 1.56 W/sq ft = 0.50 W/sq ft/10 fc (Ground area: 102.87 sq ft)
Page 8
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
4.33 ft
39.02 39.02
36.23 39.02
30.66 39.02 39.02
36.23
0.00
0.00 34.93 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:77
Workplane:
Height: 2.493 ft
Grid: 64 x 8 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.917, Ceiling / Working Plane: 1.008.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 5 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 18806 Total: 28000 400.0
Specific connected load: 2.68 W/sq ft = 0.74 W/sq ft/10 fc (Ground area: 149.33 sq ft)
Page 9
VILLA - SCHEME 3
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
4.82 ft
24.15
22.30
24.15
20.44 22.30
24.15 26.01
26.01 24.15 22.30
26.01
26.01 26.01
22.30
24.15
26.01 26.01
24.15
22.30
26.01 26.01
22.30 24.15
20.44
24.15
22.30
20.44
0.00
0.00 7.87 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:19
Workplane:
Height: 2.493 ft
Grid: 16 x 16 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.973, Ceiling / Working Plane: 1.224.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 1 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 3761 Total: 5600 80.0
Specific connected load: 2.11 W/sq ft = 0.92 W/sq ft/10 fc (Ground area: 37.97 sq ft)
Page 10