Design of RCC Rectangular Columns: 300 X 600 Column With Reinf Safe Summary of Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Design of RCC Rectangular Columns

Project :
Col Id :

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
Leff /B Leff /D
mm mm m m N/mm2 N/mm2 mm
300 600 3 7.5 20 415 40 10.00 12.50 Mux1
0.115
Slender FckBD2

Reinforcement Summary of Reinforcement Spacing Muy1


0.117
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB2
Main Ties Width Depth cm2 mm mm
16 8 3 5 12 24.12 1.34 % 86.00 110.00

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
4.62 8.09
231.00 0.00 159.00
Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 639.04
Initial 0.00 159.00
Ecc 4.62 8.09 Moment Capacity
Slenderness 0.00 10.83 @ width @ depth
Final 4.62 169.83 125.93 248.74

Summary of Design Interaction Equation


1 1
300 X 600 Column with reinf 4.62 169.83 = 0.72 < 1.0
+
12 Nos 16 dia @ 1.34 % is 125.93 248.74 Safe
SAFE