This document provides data on a gas corrosion inhibitor storage tank including operating parameters, design specifications, materials of construction, and construction details. Some key specifications include: the tank will store gas corrosion inhibitor at ambient temperature and atmospheric pressure; it will be constructed of SA 240 Gr.316L stainless steel; the total volume and max liquid volume will be provided by the vendor; it will be located offshore in Mumbai, India; and construction will meet API 12F standards.
This document provides data on a gas corrosion inhibitor storage tank including operating parameters, design specifications, materials of construction, and construction details. Some key specifications include: the tank will store gas corrosion inhibitor at ambient temperature and atmospheric pressure; it will be constructed of SA 240 Gr.316L stainless steel; the total volume and max liquid volume will be provided by the vendor; it will be located offshore in Mumbai, India; and construction will meet API 12F standards.
This document provides data on a gas corrosion inhibitor storage tank including operating parameters, design specifications, materials of construction, and construction details. Some key specifications include: the tank will store gas corrosion inhibitor at ambient temperature and atmospheric pressure; it will be constructed of SA 240 Gr.316L stainless steel; the total volume and max liquid volume will be provided by the vendor; it will be located offshore in Mumbai, India; and construction will meet API 12F standards.
This document provides data on a gas corrosion inhibitor storage tank including operating parameters, design specifications, materials of construction, and construction details. Some key specifications include: the tank will store gas corrosion inhibitor at ambient temperature and atmospheric pressure; it will be constructed of SA 240 Gr.316L stainless steel; the total volume and max liquid volume will be provided by the vendor; it will be located offshore in Mumbai, India; and construction will meet API 12F standards.
CLIENT: ONGC TAG NO. : S - 907 CONTRACTOR : SAVAIR ENERGY LIMITED. SHEET NO. : 1 OF 4 DATA SHEET OF GCI STORAGE TANK 1 OPERATING/MECHANICAL DATA 2 DESCRIPTION GCI STORAGE TANK Units 3 CONTENTS GAS CORROSION INHIBITOR 4 WORKING TEMPERATURE, NORMAL AMBIENT 0 C 5 WORKING PRESSURE, NORMAL ATM kg/cm2g 6 NOR/MIN. VAC. COND. - kg/cm2g 7 DESIGN TEMPERATURE, UPPER/LOWER 60/ - oC 8 DESIGN PRESSURE , INTERNAL/EXTERNAL (FULL WATER + 150mm WC) / 50mm WC VACUUM kg/cm2g 9 TEST PRESSURE , HYDROSTATIC/PNEUMATIC AS PER CODE kg/cm2g 10 OPERATING CONDITIONS , FLOW - m3/hr 11 DENSITY AT WORKG. TEMP. - kg/m3 12 DENSITY AT 15oC - kg/m3 13 VISCOSITY - cP 14 LENGTH OF TANK 1000 mm 15 WIDTH OF TANK 1500 mm 16 HEIGHT OF TANK 3500 mm 17 JOINT EFFICIENCY, SHELL/HEAD 1.0/1.0 18 CORROSION ALLOWANCE, TOP COVER N/A mm 19 SIDE WALLS N/A mm 20 BOTTOM PLATE N/A mm 21 SURFACE PREPARATION/PAINTING AS PER FS 2005 22 PLATE THICKNESS, OTTOM / STRUCTURE * mm 23 PLATE JOINTS, SHELL / ROOF * mm 24 25 BOTTOM * 26 FOUNDATION * 27 CONE ROOF NO 28 TOP ANGLE N/A 29 30 31 TOTAL VOLUME * m3 32 MAX LIQUID VOLUME * m3 33 WIND PRESSURE (NOTE-1) 34 EARTH QUAKE FACTOR (NOTE-2) 35 GENERAL NOTES: 36 " * " INDICATE VENDOR TO ADVICE. 37 1) WIND FORCE CALCULATION SHALL BE CARRIED OUT AS PER API RP 2A WSD (MAX WIND SPEED191 Km/hr). 38 2) EARTHQUAKE FACTOR SHALL BE AS PER SECTION 3.4.6.1 OF "3.4 STRUCTURAL DESIGN CRITERIA PART-I REV-3" 39 3) PAINTING SHALL BE AS PER CLIENT "SPEC.2005", REV.3 PROTECTIVE COATING FOR OFFSHORE STRUCTURES AND 40 FACILITIES. 4) REINFORCING PADS SHALL HAVE A MINIMUM WIDTH OF 50 mm OR THREE TIMES THE PAD THICK NESS, WHICHEVER 41 IS 42 GREATER. EACH PAD SHALL CONTAIN AT LEAST ONE 1/2" NPT TAPPED TELL TALEHOLE. 5) ALL RECTANGULAR REINFORCING PADS WHEN USED FOR EXTERNAL OR INTERNAL ATTACHMENTS SHALL HAVE 25 43 mm MINIMUM 44 RADIUS AT CORNERS. 45 6) THE NOZZLE ELEVATION, PROJECTION AND ORIENTATION WILL BE FINALIZED DURING DETAILED ENGINEERING. 7) NOZZLE PROJECTION SHALL BE A MINIMUM OF 200mm FOR SIZES LESS THAN OR EQUAL TO 12" AND 250 mm FOR 46 SIZES 47 GREATER THAN 12" FROM OUTER MOST LAYER OF SHELL OR INSULATION WHICHEVER IS APPLICABLE. 48 8) HATCH AND CLEANOUT OPENINNG SHALL BE PROVIDED AS PER API 12F. 9) ALL ALLOY STEEL STUD BOLTS AND NUTS SHALL BE HOT DIP GALVANIZED OR ELECTROGALVANIZED WITH MINIMUM 49 COATING 50 AS PER SPEC 2005,FS FOR PROTECTIVE COATING. 51 52 53 A 14/01/2013 ISSUED FOR ENQUITY AC MK MK REV. DATE PURPOSE PRPD BY CHKD BY APPRD BY OWNER LSTK
PROJECT: DOCUMENT NO.:
CLIENT: ONGC TAG NO. : S - 907 CONTRACTOR : SAVAIR ENERGY LIMITED. SHEET NO. : 2 OF 4 DATA SHEET OF GCI STORAGE TANK 1 MANUFACTURER * 56 SERIAL No. * No. OF: 1 2 SERVICE GAS CORROSION INHIBITO 57 CONSTRUCTION MATERIALS 3 ORIENTATION RECTANGULAR 58 PART MATERIAL SPECIFICATION 4 LOCATION OFF SHORE, MUMBAI 59 TOP / BOTTOM COVER SA 240 Gr.316L 5 DESIGN CODE API 12F 60 SIDES SA 240 Gr.316L 6 SPECIFICATIONS 5601 61 REINFORCING PAD SA 240 Gr.316L (NOTE - 4 & 5 7 CONSTRUCTION CATEGORY N/A 62 NOZZLE NECK PLATE SA 240 Gr.316L 8 QUANTITY 1 63 NOZZLE NECK PIPE SA 312 TP 316L 9 64 FORGED NOZZLES SA 182 F316L 10 65 FORGED FLANGES SA 182 F316L 11 DESIGN DATA 66 WELDING ELBOWS SA 403 Gr.316L 12 PARAMETER UNITS 67 INTERNAL COATING AS PER FS 2005 13 GROSS CAPACITY m3 * 68 NOZZLE PIPE-EXTERNAL SA 312 TP 316L 14 SPECIAL SERVICE NO 69 SUPPORT SS 316L / SA 516 Gr 70 N 15 CODE STAMP NO 70 SADDLES N/A 16 JOINT EFFICIENCY, SHELL/HEAD 1/1 71 WRAPPER PLATES N/A 17 RADIOGRAPHY 100% 72 STIFFENING RINGS N/A 18 ULTRASONIC AS PER CODE 73 BASE PLATE N/A 19 MAGNETIC PARTICLE AS PER CODE 74 EXTERNAL ATTACHMENTS SS 316L 20 DYE PENETRANT AS PER CODE 75 INTERNAL ATTACHMENTS SS 316L 21 POST WELD HEAT TREATMENT AS PER CODE 76 BOLTED INTERNALS SS 316L 22 INSULATION NO 77 EXTERNAL BOLTS ASTM A193 Gr.B7 (NOTE - 9) 23 - THICKNESS mm N/A 78 NUTS ASTM A194 Gr.2H (NOTE - 9) 24 - TYPE N/A 79 GASKETS (NOTE - 10) 25 FIRE-PROOFING mm N/A 80 INTERNAL BOLTS SS 316L (NOTE - 9) 26 PAINTING (NOTE - 3) 81 NUTS SS 316L (NOTE - 9) 27 CERTIFYING AUTHORITY CLIENT/TPI 82 MATERIAL IMPACT TEST REQUIRED AS PER CODE 28 83 CERTIFIED ELEVATED TEMP. TESTS REQDNO 29 84 CONSTRUCTION 30 85 TYPE OF HEADS N/A 31 86 PLATFORM/LADDER/PIPE CLIPS YES 32 87 INSULATION SUPPORTS N/A 33 88 HATCH & CLEANOUT YES 34 89 EARTHING BOSS YES ( 2 NO.) (NOTE - 11) 35 90 LIFTING LUGS YES (NOTE - 12) 36 91 NAME PLATE YES - SS 316 (NOTE - 13) 37 92 WEIGHTS AND OVERALL DIMENSIONS 38 93 EMPTY WEIGHT, kg * 39 94 OPERATING WEIGHT, kg * 40 95 TEST WEIGHT, kg * 41 96 O'ALL DIMENSIONS OF TANK, mm 1000(L) x 1500(W) x 3500(H) 42 97 43 GENERAL NOTES:(CONT.) 44 10) GASKETS FOR FLANGES SHALL BE ASME B 16.21, FLAT RING,1.58mm, CNAF. 45 11) VESSEL 12) SHALL ALL VESSEL BE PROVIDED SHALL WITH WITH BE FURNISHED MINIMUM OF TWOOF A MINIMUM EARTHING BOSSES. TWO LIFTING LUGS, WHICH SHALL BE DESIGNED FOR A LOAD EQUAL 46 TO TWO 47 TIMES THE SHIPPING WEIGHT. 48 13) NAME PLATE SHALL BE IN ACCORDANCE WITH API OR FUNC. SPECIFICATION "5601-UNFIRED-PRESSURE-VESSEL", Rev. 2. 49 14) NECESSARY CONSIDERATION SHALL BE FOLLOWED TO AVOID GALVANIC CORROSION OF STUD AND NUT. 50 15) TANK SHALL BE DESIGNED FOR A DESIGN LIFE OF 25 YEARS. 51 16) WELDING AND NDT SHALL BE AS PER SPEC 2009F, "FUNCTIONAL SPECIFICATION FOR WELDING AND NDT". 52 17) "*" VENDOR TO CONFIRM 53 18) FLANGE FACE SHALL BE SETRATED FINISH TYPE. 54 19) NOZZLE SIZES TO BE CONFIRMED BY VENDOR. 55 A 16/01/2013 ISSUED FOR ENQUIRY AC MK MK REV DATE PURPOSE PRPD BY CHKD BY APPD BY OWNER LSTK
PROJECT: DOCUMENT NO.:
CLIENT: ONGC TAG NO. : S - 907 CONTRACTOR : SAVAIR ENERGY LIMITED. SHEET NO. : 3 OF 4 DATA SHEET OF GCI STORAGE TANK NOM FLANGE R.F. PAD ELEVATION & SCH / PROJECTION Sl. No MARK No.OFF SIZE O/D THK SERVICE ORIENTATIO BLIND FLANGE THK RATING TYPE FACE FROM C.L (Inches ) mm mm N 1 N1 1 1" 40S/- 150# SW RF - - GCI INLET (NOTE-6) (NOTE-7) 2 N2 1 1" 40S/- 150# SW RF - - GCI OUTLET 3 N3 1 1" 40S/- 150# SW RF - - PSV CONNECTION 4 V 1 4" 10S/- 150# WN RF * * VENT C/W GOOSE NECK 5 N4 1 2" 10S/- 150# WN RF - - DRAIN 6 N5 1 2" 10S/- 150# WN RF - - OVER FLOW CONNECTION 7 N6 1 2" 10S/- 150# WN RF - - LEVEL INDICATOR 8 LS 2 1" 40S/- 150# SW RF - - LEVEL SWITCH 9 LT 1 3" 10S/- 150# WN RF * * LEVEL TRANSMITTER 10 H 1 8" 150# WN RF * * HATCH 11 CL 1 20" 150# WN RF * * CLEANOUT OPENING 12 13 14 APPLICABLE CODES AND STANDARDS REFERENCE DOCUMENT / DRAWING LIST 15 Sl.No. DESCRIPTION SI.No. SPEC. DESCRIPTION 16 1 ASME B 16.5 FOR PIPE FLANGES 1 P&ID CHEMICAL INJECTION SYSTEM 17 2 ASME SEC V FOR NDE 18 3 ASME SEC-II MATERIAL SPECIFICATIONS 19 4 API 12F 20 21 22 23 24 APPLICABLE STANDARD SPECIFICATIONS 25 Sl.No. DESCRIPTION DOC. NO. REV 26 1 FS-UNFIRED PRESSURE VESSELS 5601 2 27 2 FS-PROTECTIVE COATING & ADDENDUM 2005 3 28 3 FS-WELDING & NDT 2009F 6 29 30 31 32 33 34 GENERAL NOTES: 20) HAZARDOUS AREA CLASSIFICATION OF THE EQUIPMENT SHALL BE MIN. CLASS I, DIV 2 / ZONE 2 OR AS PER ELECTRICAL 35 36 DESIGN CRITERIA VOL II SEC 3.5 . 37 21) REFER P&ID's LEGENDS FOR NOTES AND DETAILS. 38 22) PIPE AND PIPING COMPONENT SHALL COMPLY WITH PIPING MATERIAL SPECIFICATION, FS 2008. 39 40 41 42 43 HOLD : TANK SIZE SHALL BE CONFIRMED DURING DETAILED ENGINEERING. 44 45 46
A 16/01/2013 ISSUED FOR ENQUIRY AC MK MK
REV DATE PURPOSE PRPD BY CHKD BY APPRD BY OWNER LSTK
PROJECT: DOCUMENT NO.:
CLIENT: ONGC TAG NO. : S - 907 CONTRACTOR : SAVAIR ENERGY LIMITED. SHEET NO. : 4 OF 4 DATA SHEET OF GCI STORAGE TANK Sl. No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 NOTES 37 1) ALL NOZZLES ORIENTATION, SIZE, ELEVATION ARE 38 ONLY INDICATIVE AND UNDER HOLD 39 2) PLATE THICKNESS SHALL BE CALCULATED BY VENDOR 40 AS PER API 12F 41 42 43 44 45 46