Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Engine Serial Number: 0 Software Phase: 02060502

Unit Number: Image Date: 03/05/2017


ECM Code: P10106.06 Customer Name:
System Type: QSK19G/38G/60G, QSV81/91 - CM700/CM2358
Fault Snapshot

Total ECM Time :361:35:33


Total Engine Hours : 276:00:25

Fault Code :1434


Fault Code description:Operator Interface Mode Transition to Emergency Stop (Due to Remote E-Stop) - Condition Exists

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :1457


Fault Code description:Generator Synchronizing to Electric Bus Failed - Condition Exists

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi


Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :1459


Fault Code description:Generator is absorbing Power from the Electric Bus - Data Valid But Below Normal Operating Range -
Most Severe Level

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :2228


Fault Code description:Fuel Delivery Pressure 1 - Data Valid But Above Normal Operating Range - Most Severe Level

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :2455


Fault Code description:External Governor Speed or Frequency Bias - Current Below Normal or Open Circuit

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :2458


Fault Code description:Exhaust Gas Temperature Cylinder 2 (B1) - Data Valid But Below Normal Operating Range - Moderately
Severe Level

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :2475


Fault Code description:Exhaust Gas Temperature Cylinder 9 (A5) - Data Valid But Below Normal Operating Range - Moderately
Severe Level

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :2483


Fault Code description:Engine Starter Mode Engagement - Mechanical System Not Responding or Out of Adjustment

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40


Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Analog Speed Bias 0 0 Percent
Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

Fault Code :9113


Fault Code description:Engine ECM to Power Command Controller (PCC) Communication - Data Erratic, Intermittent, or Incorrect

Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault
ECM Run Time 0:03:39 190:10:27 HH:MM:SS 361:31:54 171:25:06
Engine Run Time 0:00:00 9324:19:05 HH:MM:SS 276:00:25 -9048:18:40
Engine Speed 0 575 RPM
Low Temperature
0.00 10.58 psig
Coolant Pressure
ECM Supply
0.00 5.00 V
Voltage C
Battery Voltage 0.0 26.5 V
Commanded Power
Command
50.43 50.43 Percent Duty Cycle
Supervisor Speed
Bias
Sensed Kilowatt
0 0 kW
Load
Engine Start
0 0 counts
Attempts
High Temperature
0.00 23.27 InHg
Coolant Pressure
Low Temperature
Coolant 24.4 106.9 F
Temperature
Oil Temperature 42.7 131.0 F
Oil Outlet Pressure 0.00 42.84 psi

Oil Inlet Pressure 0.0 495.1 psi

Free End Air Filter


0.00 0.00 inH2O
Differential Pressure
Desired Engine
900 900 RPM
Speed
Isolated Battery
0.0 26.6 V
Voltage
Parameter First Occurrence Last Occurrence Unit Time since First FaultTime since Last Fault

Analog Speed Bias 0 0 Percent


Desired Engine
100 100 Percent
Torque
High Temperature
Coolant 10.7 158.5 F
Temperature
Emergency Emergency
Engine State
Shutdown Shutdown
ECM Supply
0.00 5.01 V
Voltage A
ECM Supply
0.00 5.01 V
Voltage B
Emergency Stop Emergency Stop
Shutdown Cause
Switch Switch
Internal ECM
0.0 101.8 F
Temperature
Cylinder A1 Exhaust
0 52414 F
Port Temperature

Cylinder A2 Exhaust
0 49354 F
Port Temperature

Cylinder A3 Exhaust
0 52414 F
Port Temperature

Cylinder A4 Exhaust
0 49348 F
Port Temperature

Cylinder A5 Exhaust
0 50884 F
Port Temperature

Cylinder A6 Exhaust
0 50884 F
Port Temperature

Cylinder A7 Exhaust
0 50908 F
Port Temperature

Cylinder A8 Exhaust
0 57040 F
Port Temperature

Cylinder A9 Exhaust
0 53980 F
Port Temperature

Cylinder B1 Exhaust
0 56992 F
Port Temperature

Cylinder B2 Exhaust
0 41656 F
Port Temperature

Cylinder B3 Exhaust
0 47824 F
Port Temperature

Cylinder B4 Exhaust
0 53992 F
Port Temperature

Cylinder B5 Exhaust
0 60136 F
Port Temperature

Cylinder B6 Exhaust
0 202 F
Port Temperature

Cylinder B7 Exhaust
0 52942 F
Port Temperature

Cylinder B8 Exhaust
0 53966 F
Port Temperature

Cylinder B9 Exhaust
0 52766 F
Port Temperature
System Switch
Key Switch Key Switch
Status
System Switch Switch 16 Switch 16
Status "Undefined" "Undefined"
System Driver
Lamp_1_Feedback Lamp_1_Feedback
Status
System Driver
Undefined Undefined
Command

You might also like