Professional Documents
Culture Documents
FRP Structural Shapes Catalog
FRP Structural Shapes Catalog
Corrosion Resistance
For Demanding Environments
www.endurocomposites.com
Tuff Span FRP Structural Shapes
Corrosion Resistant Long Span Non-Conductive
Tuff Span 8F6 beams and roofing panels at galvanizing Tuff Span 8F6 and 18F17 beams at EMI Test Facility
plant. Tuff Span building products provide outstanding under construction. Tuff Span FRP building products
corrosion protection and substantial, life-cycle cost are non-conductive and RF transparent.
savings.
Table of Contents
Tuff Span FRP Structurals Pg 1
8F6 Purlin/Girt:Details/Specifications Pg 2
Span Table Notes Pg 3 16602 Central Green Blvd
Shape Availability/Properties Pg 3 Houston, TX 77032
Load/Span Tables Pg 48 713.358.4000 _ 800.231.7271
www.endurocomposites.com
Details: Tuff Span 8F6 FRP Purlin/Girt System
Design parameters used for the tables on the following pages are based on material testing and theoretical analysis. Allowable uniform loads,
shown in lbs/ft, are limited by bending moment with applied factor of safety (FOS) and deflection (L/D) expressed as the ratio between span
length and the allowable limit. This information should be used as a guide only with usage verified by a registered Professional Engineer.
Nomenclature
W = Weight per lineal foot, lb/ft Ixx = Moment of Inertia,centroidal x-x axis, in4 Fb = Flexural Stress (psi)
2
A = Cross-sectional area, in Iyy = Moment of Inertia, centroidal y-y axis, in4 R = Radius of Gyration (in)
E = Apparent flexural modulus, psi Bf/Bt = Flange width/Flange thickness ratio Aw = Area of web (in2)
G = Apparent modulus of rigidity, psi K = Effective column length factor Sxx = Section Modulus, X-Axes (in3)
M = Bending moment capacity, lb.-in.
3
16602 Central Green Blvd.
Tuff Span FRP Structurals Houston, TX 77032
4
16602 Central Green Blvd.
Tuff Span FRP Structurals Houston, TX 77032
5
16602 Central Green Blvd.
Tuff Span FRP Structurals Houston, TX 77032
1 5/8 x 1 5/8 x 1/8 Square Tube Allowable Uniform Load Column Load
W= 0.56 lb/ft Span Stress L/D= 120 L/D= 180 L/D= 240 Lth Axial
A= 0.74 in2 (Ft.) Fb_Fv 1 2 1 2 1 2 (Ft.) (Lbs.)
Ixx = 0.28 in4 1 1020 1020 1020 1020 1020 834 1020 1 4530
Iyy = 0.28 in4 2 415 328 415 219 415 164 311 2 4530
E= 2,600,000 psi 3 184 109 184 72 154 54 115 3 4157
G= 425,000 psi 4 104 48 104 32 71 24 53 4 2860
Fb = 7,346 psi 5 66 25 57 17 38 12 29 5 2140
r= 0.61 in 6 46 15 34 10 23 7 17 6 1688
Aw = 0.34 in2 7 34 9 22 6 14 5 11 7 1382
Sxx = 0.339 in3 8 26 6 15 4 10 3 7 8 1161
Bf/Bt = 13 9 20 4 10 3 7 2 5 9 997
K= 1 Shear FOS = 3 Bending FOS = 2.5 Col. FOS = 3
6
16602 Central Green Blvd.
Tuff Span FRP Structurals Houston, TX 77032
7
16602 Central Green Blvd.
Tuff Span FRP Structurals Houston, TX 77032
Column Load
6 x 6 x 3/8 Angle
Length (Ft.) Axial (Lbs.)
W= 2.2 lb/ft 3 17955
A= 2.74 in2 4 17955
Imin = 3.5 in4 5 17658
E= 2,600,000 psi 6 13932
r= 1.13 in 7 11402
Bf/Bt = 12 8 9585
K= 1 9 8224
10 7172 Column FOS = 3
Column Load
4 x 4 x 3/8 Angle
Length (Ft.) Axial (Lbs.)
W= 2.22 lb/ft 3 5248
A= 2.81 in2 4 4480
E= 2,600,000 psi 5 3962
r= 0.77 in 6 3584
Bf/Bt = 10.67 7 3293
K= 1 8 3060
9 2868
10 2706 Column FOS = 3
Column Load
3 x 3 x 3/8 Angle
Length (Ft.) Axial (Lbs.)
W= 1.63 lb/ft 3 3261
A= 2.06 in2 4 2783
E= 2,600,000 psi 5 2462
r= 0.57 in 6 2227
Bf/Bt = 12 7 2046
K= 1 8 1901
9 1782
10 1682 Column FOS = 3
8